• Title/Summary/Keyword: Inject characteristics

Search Result 62, Processing Time 0.027 seconds

A Study on the Pressure Increment of Fuel Pump for GDI Engines Considering Leakage Flows (누설특성을 고려한 GDI 엔진용 연료펌프의 고압생성 증진에 관한 연구)

  • Na, Byung-Chul;Kim, Byoung-Soo;Choi, Suk-Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.6
    • /
    • pp.785-791
    • /
    • 2000
  • GDI (Gasoline Direct Injection) engines are considered as one of the candidates for next generation engines of passenger cars, which reduce exhaust emissions and fuel consumption. In GOI engines, a high-pressure gasoline supply system is required to directly inject the fuel to combustion chambers. Because of low lubricity of gasoline fuel, the clearance between a plunger and a barrel in GDI fuel pumps is too wide to achieve smooth hydrodynamic lubrication. Thus, it is difficult to generate high-pressure condition in GDI fuel pump since large amount of leakage flow occurs between the plunger and the barrel In this study, an optimum plunger design is presented to minimize leakage in the aspect of flow control. This paper analyzes leakage flow characteristics in the clearance to improve pumping performance of GDI fuel pumps. Effects of groove in the plunger are studied according to variations of depth and width. Evaluations of pumping performance are determined by the amount of pressure drop in the leakage path assuming a constant leakage flows. Both of turbulence and incompressible models are introduced in CFD (Computational Fluid Dynamics) analysis. Design parameters have been introduced to minimize leakage in limited space, and a methodological study on geometrical optimization has been conducted. As results of CFD analysis in various geometrical cases, optimum groove depths have been found to generate maximum sealing effects on gasoline fuel between the plunger and the barrel. This procedure offers a methodological way of an enhancement of plunger design for high-pressure GDI fuel pumps.

Development of Alternative External Carbon Source from Wasting Carbonaceous Organic Resource and Full Scale Application (유기폐자원을 이용한 고도하수처리 대체탄소원 개발 및 실플랜트 적용)

  • Jung In Chul;Kim Ho Young;Kang Dong Hyo;Jung Joung Soon;Lee Sang Won;Lim Keun Taek;Kim Chang Won
    • Journal of Environmental Science International
    • /
    • v.13 no.10
    • /
    • pp.911-919
    • /
    • 2004
  • The purpose of this research was evaluated economical effect to apply alternative external carbon source. Conventional activated sludge process in municipal wastewater treatment plant was adapted and introduced to Biological nutrient removal processes to meet the newly enforced effluent quality standard for nutrient removal in Korea. Low $COD/NH_4^+-N$ ratio and higher nutrient concentration of influent characteristics force to inject external carbon source for denitrifying recycled nitrate. In the most case, methanol was used as external carbon source. But Methanol is expensive and very dangerous in handling. So we could find cheaper and safer external carbon source substituted methanol in last study. This alternative external carbon source is named RCS(recoverd carbon source) and a by-product of fine chemical product at chemical plant. When RCS was applied real municipal wastewater treatment plant, average $55\~65\%$ of T-N removal efficiency, 8.8mg/l of effluent T-N concentration, 11.3mg/l of effleunt COD concentration were obtained without effluent COD increase as against used methanol. To apply RCS in municipal wastewater treatment plant obtain approximately $\74.5%$ expenditure cost reduction in comparison with methanol dosage cost.

A Study on the Expressed Desire at Discharge of Patients to Use Home Nursing and Affecting Factors of the Desire (퇴원환자의 가정간호 이용의사와 관련 요인)

  • Lee, Ji-Hyun;Lee, Young-Eun;Lee, Myung-Hwa;Sohn, Sue-Kyung
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.2 no.2
    • /
    • pp.257-270
    • /
    • 1999
  • The purpose of this study is to investigate factors related to the intent of using home nursing of chronic disease patients who got out of a university hospital. For the purpose, the study selected 153 patients who were hospitalized and left K university hospital with diagnoses of cancer, hypertension, diabetes and cerebral vascular accident and ordered to be discharged and performed interviews with them and surveys on their medical records to obtain the following results. For this study a direct-interview survey and medical record review was conducted from June 28 to Aug. 30, 1998. The frequency and mean values were computed to find the characteristics of the study subjects, and $X^2$-test, t-test, factor analysis and multiple logistic regession analysis were applied for the analysis of the data. The following results were obtained. 1) When characteristics of the subjects were examined, men and women occupied for 58.8% and 41.2%, respectively. The subjects were 41.3 years old in aver age and had the monthly aver age earning of 0.99 million won or below, which was the most out of the total subjects at 34.6%. Among the total, 87.6% resided in cities and 12.4 in counties. The most left the hospital with diagnosis of cancer at 51.6%, followed by hyper tension at 24.2%, diabetes at 13.7% and cerebral vascular accident at 7.2%. 2) 93.5% of the selected patients had the intent of using home nursing and 6.5%, didn't. Among those patients having the intent, 85.6% had the intent of paying for home nursing and 14.4%, didn't. The subjects expected that the nursing would be paid 9,143 won in aver age and 47.7% of them preferred national authorities as the main servers. 86.3% of the subjects thought that home nursing business had the main advantage of making it possible to learn nursing methods at home and thereby contributing to improving the ability of patients and their facilities to solve health problems. 3) Relations between the intent of use and characteristics of the subjects such as demography-related social, home environment, disease and physical function characteristics did not show statistically significant differences among one another. Compared to those who had no intent of using home nursing, the group having the intent had more cases of male patients, the age of 39 or below, residence in cities, 5 family member s or more, no existence of home nursing servers, leaving the hospital from a non-hospitalized building, disease development for five months or below, hospitalization for ten days or more, non-hospitalization with in the recent one month, two times or over of hospitalization, leaving the hospital with no demand of special treatment, operation underwent, poor results of treatment, leaving the hospital with demand of rehabilitation services, physical disablement and high evaluation point of daily life. 4) Among those patients having the intent of using home nursing, 47.6% demanded technical nursing and 55.9%, supportive nursing. As technical nursing,' inject into a blood vessel ' and 'treat pustule and teach basic prevention methods occupied for 57.4%, respectively, topping the list. Among demands of supportive nursing, 'observe patients 'status and refer them to hospitals or community resources as available, if necessary' was the most with percent age point of 59.5. Regarding the intent of paying for home nursing, 39.2% of those patients wishing to use the nursing responded paying for technical services and 20.2, supportive services. In detail, 70.0% wanted to pay for a service stated as 'inject into a blood vessel', highest among the former services and 30.7%, a service referred to as 'teaching exercises needed to make the body of patients move', highest among the latter. When this was analyzed in terms of a relation between the need(the need for home nursing) and the demand(the intent of paying for home nursing), The rate of the need to the demand was found two or three times higher in technical nursing(0.82) than in supportive nursing(0.35). In aspects of tech ical nursing, muscle injection(1.26, the 1st rank) was highest in the rate while among aspects of supportive nursing, a service referred to as 'teach exercises needed for making patients move their bodies normally'(0.58, the 1st rank). 5) factors I(satisfaction with hospital services), II(recognition of disease state), III(economy) and IV(period of disease) occupied for 34.4, 13.8, 11.9 and 9.2 percents, respectively among factors related to the intent by the subjects of using home nursing, totaled 59.3%. In conclusion, most of chronic disease patients have the intent of using hospital-based home nursing and satisfaction with hospital services is a factor affecting the intent most. Thus a post-management system is needed to continue providing health management to those patients after they leave the hospital. Further, supportive services should be provided in order that those who are satisfied with hospital services return to their community and live their in dependent lives. Based on these results, the researcher would make the following recommendation. 1) Because home nursing becomes more and more needed due to a sharp increase in chronic disease patients and elderly people, related rules and regulations should be made and implemented. 2) Hospital nurses specializing in home nursing should be cultivated.

  • PDF

Interpretation of Making Techniques through Surface Characteristic Analysis and Non-destructive Diagnosis for the Gilt-bronze Seated Buddha in Dangjin Sinamsa Temple, Korea (당진 신암사 금동여래좌상의 표면특성 분석과 비파괴 정밀진단을 통한 제작기술 해석)

  • CHOI Ilkyu ;YANG Hyeri ;HAN Duru;LEE Chan Hee
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.1
    • /
    • pp.100-116
    • /
    • 2023
  • The Sinamsa Temple was built in the late Goryeo Dynasty and a gilt-bronze seated Buddha is enshrined in Geungnakjeon hall in the precinct. Various damages occurred in the gilt layer of the Buddha, such as peeling of the gilt layer and deteriorating gloss. In the study, the conservation conditions of the inside and outside on the statue were accurately investigated, and the making technique was interpreted through the material characteristics and non-destructive diagnosis of the statue. As a result, it is estimated that gold-gilding layer is pure gold, coloration pigment of black is carbon, green is malachite, atacamite and verdigris, red is red lead and cinnabar, respectively. In the deterioration evaluation, peeling, cracking, break out and exfoliation of the gilt layer are confirmed as damages, but the conservation condition is relatively wholesome. However, the gloss of the gilt layer is calculated to be wider in the poorer part than the maintenance part. The ultrasonic velocity of the statue was calculated to be 1,230 to 3,987 (mean 2,608) m/s and showed a relatively wide range. In infrared thermography, peeling was not confirmed, and no special bonding marks were found. In endoscope, some biological damage and corrosion were observed on the surface of the internal metal, and sealed artifacts were identified. Manufacturing technique based on the study, it is considered that the gilt-bronze seated Buddha was cast at once, and the mold was inverted to inject molten metal.

Hysteresis of the Suction Stress in Unsaturated Weathered Mudstone Soils (불포화 이암풍화토에서의 흡입응력 이력현상)

  • Song, Young-Suk;Choi, Jin-Su
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.3
    • /
    • pp.55-66
    • /
    • 2012
  • To investigate the hysteresis of the suction stress in unsaturated weathered mudstone soils (CL), matric suction and volumetric water content were measured in both drying and wetting processes using Automated Soil-Water Characteristics Curve Apparatus. The drying and wetting processes in unsaturated soils were reproduced in the test; the drying process means to load matric suction to spill pore water from the soils, and the wetting process means to unload matric suction to inject pore water into the soils. Based on the measured result, Soil Water Characteristic Curve(SWCC)s were estimated by van Genuchten model (1980). SWCCs have nonlinear relationship between effective degree of saturation and matric suction. The hysteresis in SWCCs between drying and wetting processes occurred. As a result of estimating Suction Stress Characteristic Curve(SSCC) using Lu and Likos model (2006), the suction stress rapidly increased in the low level of matric suction and then increased slightly. Also, the hysteresis in SSCCs between drying and wetting processes occurred. In order to design geo-structures and check its stability considering unsaturated soil mechanics, therefore, it is more reasonable that the SSCC of drying process should be applied in the condition of rainfall infiltration and the SSCC of wetting process in the condition of evaporation or drainage.

Knowledge and Attitudes of Oncology Nurses Toward Cancer Pain Managements (암 병동 간호사의 통증관리에 대한 지식과 태도)

  • Gong, Soung-Wha;Bang, Jji-Yha;Seo, Min-Sook;Hyun, Sin-Sook;Kim, Hee-Jung;Lee, Mi-Ae;Lee, Mi-Ae;You, Hyen-Hee;Her, Jae-Kyoung;Kim, Eun-Ae;Park, Kyung-Sook
    • Korean Journal of Adult Nursing
    • /
    • v.16 no.1
    • /
    • pp.5-16
    • /
    • 2004
  • Purpose: The purpose of this study is to evaluate the knowledge and attitudes of oncology ward nurses toward cancer pain management and to find ways to improve the educational program for nurses. Method: A total of 209 nurses working at the oncology ward of three hospitals in Seoul and a Gyenggi Province. The survey instrument used was the 32-item scale for evaluating nurses knowledge and attitudes originally developed by McCaffery and Ferrell'(1990), that was by Kim'(1997). Result: In terms of the nurses knowledge of pain management, the result showed that the nurses scored an average of 67.8 out of 100 for phamacokinetics of opioids, 84.8 for classification of analgesics, 60.1 for pain assessment, and 70.7 for drug administration. 18.2% of the nurses hesitate to inject the narcotic agent because of concerns regarding the drug's potential side effects. there was significant difference in the knowledge of pain management according to the general characteristics of pain in terms of the nurses age(p=.001), position (p=.016), years of experiences(p=.002), experience of cancer pain education(p=.001). Conclusion: The also showed that nurses working at cancer ward lack knowledge. It is important to provide intensive education to nurses about cancer pain management.

  • PDF

Evaluation of Water Quality Characteristics of Floor Fountains in Gwangju (광주지역 바닥분수의 수질특성 평가)

  • Kim, Jong-Min;Kim, Ha-Ram;Jang, Seo-Eun;Choi, Yeong-Seop;Kang, Yu-Mi;Jung, Sook-Kyoung;Cho, Young-Gwan;Kim, Eun-Sun
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.2
    • /
    • pp.143-156
    • /
    • 2017
  • The purpose of this study was to investigate water quality through a field survey at six floor fountain sites. The floor fountain facilities were designed and operated in such a way that tap water was stored in a water tank and recycled repeatedly. The water tank was cleaned once or twice per week in the summer. The number of facility users was low during the day due to sweltering heat, but up to 40 people, mainly children, were using them around 8 pm. Since the operation time was as short as 30 minutes, it is considered necessary to extend it for at least one hour for the number of users. As a result of the water quality test of the reservoir tank prior to operation after cleaning, it was measured to be within drinking water quality standards at the six facilities. As a result of the water quality test after use, ammonia nitrogen was measured to be 1.45 mg/L at Site IV. This exceeded the drinking water quality standard of 0.5 mg/L. In the case of turbidity, two cases exceed at 7.38 and 4.52 NTU when applying 4 NTU as the water quality standard for waterscape facilities. Twenty-eight cases exceed the standard of drinking water quality. The result of microbiological tests, at five sites excepting Site I, where disinfectant was injected, was that the maximum total colony count was 180,000 CFU/mL, total coliforms was 2,100,000 CFU/100 mL, fecal coliforms was 4,600 CFU/100 mL, Escherichia coli was 170 MPN/100 mL and Enterococcus was 100 CFU/100 mL. This exceeded the water quality standards of drinking water. Children are very likely to inhale because the water spews from below and falls from above, so it is necessary to apply water quality standards for ammonia nitrogen, turbidity and microbes. Current floor fountain facilities are highly susceptible to disease caused by microbial contamination because of water cycling and reuse, so it is necessary to change the water every day, clean the water tank, and perform chlorination. Therefore, it is necessary to inject calcium hypochlorite according to the free chlorine water quality standard of swimming pools with a different water tank capacity. In addition, facilities should be improved to prevent the reuse of water by installing the water tank at a separate location.

X-ray properties measurement of Flat panel Digital X-ray gas detector (평판형 디지털 엑스레이 가스 검출기의 엑스선 특성 측정기술에 관한 연구)

  • Yoon, Min-Seok;Cho, Sung-Ho;Oh, Kyung-Min;Jung, Suk-Hee;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • The Recently, large area matrix-addressed image detectors are investigated for X-ray imaging with medical diagnostic and other applications. In this paper, a new flat panel gas detector for diagnostic X-ray imaging is proposed, and its characteristics are investigated. The research of flat panel gas detector is not exist at all. Because of difficulty to inject gas against to atmospheric pressure. So almost gas detector made by chamber shape. We made flat panel sample by display technique. (ex: PDP, Fed, etc.) The experimental measurements, the transparent electrodes, dielectric layer, and the MgO protection layer were formed in front glass. And, the X-ray phosphor layer and address electrodes are formed in the rare glass. The dark current, the x-ray sensitivity and linearity as a function of electric field were measured to investigate the electrical properties. From the results, the stabilized dark current density and the significant x-ray sensitivity were obtained. And the good linearity as a function of exposure dose was showed in wide diagnostic energy range. These results means that the passive matrix-addressed flat panel gas detector can be used for digital x-ray imaging.

  • PDF

Fresh Water Injection Test in a Fractured Bedrock Aquifer for the Mitigation of Seawater Intrusion (해수침투 저감을 위한 균열암반 대수층 내 담수주입시험)

  • Shin, Je-Hyun;Byun, Joong-Moo
    • Economic and Environmental Geology
    • /
    • v.43 no.4
    • /
    • pp.371-379
    • /
    • 2010
  • Fresh water injection test in a fractured bedrock aquifer was applied as an efficient approach to lower saline concentrations in the saltwater-freshwater transition zone formed by seawater intrusion in a coastal area. The methodology and effectiveness of fresh water injection for hydraulically controlling seawater intrusion is overwhelmingly site dependent, and there is an urgent need to characterize the permeable fractures or unconsolidated porous formations which can allow for seawater flow and transport. Considering aquifer characteristics, injection and monitoring boreholes were optimally designed and completed to inject fresh water through sand layer and fractured bedrock, respectively. We devised and used the injection system using double packer for easy field operation and maintenance. Overall fracture distribution was systematically identified from borehole image logs, and the section of fresh water injection was decided from injection test and monitoring. With fresh water injection, the fluid electrical conductivity of the monitoring well started to be lowered by the inflow of fresh water at the specific depth. And this inflow leaded to the replacement of the fluid in the upper parts of the borehole with fresh water. Furthermore, the injection effect lasted more than several months, which means that fresh water injection may contribute to the mitigation of seawater intrusion in a coastal area.

Improvement in the Dispersion Stability of Iron Oxide (Magnetite, Fe3O4) Particles with Polymer Dispersant Inject (고분자 분산제 주입을 통한 철산화물(Magnetite, Fe3O4) 입자의 분산 안정성 향상)

  • Song, Geun Dong;Kim, Mun Hwan;Lee, Yong Taek;Maeng, Wan Young
    • Applied Chemistry for Engineering
    • /
    • v.24 no.6
    • /
    • pp.656-662
    • /
    • 2013
  • The iron oxide ($Fe_3O_4$) particles in the coolant of the secondary system of a nuclear power plant reduce the heat transfer performance or induce corrosion on the surface of the heat transfer tube. To prevent these problems, we conducted a study to improve the dispersion stability of iron oxide using polymeric dispersant injection in simulated secondary system water. The three kinds of anionic polymers containing carboxyl groups were selected. The dispersion characteristics of the iron oxide particles with the polymeric dispersants were evaluated by performing a settling test and measuring the transmission, the zeta potential, and the hydrodynamic particle size of the colloid solutions. Polymeric dispersants had a significant impact on the iron oxide dispersion stability in an aqueous solution. While the dispersant injection tended to improve the dispersion stability, the dispersion stability of iron oxide did not increase linearly with an increase in the dispersant concentration. This non-linearity is due to the agglomerations between the iron oxide particles above a critical dispersant concentration. The effect of the dispersant on the dispersion stability improvement was significant when the dispersant concentration ratio (ppm, dispersant/magnetite) was in the range of 0.1 to 0.01. This suggests that the optimization of dispersant concentration is required to maximize the iron oxide removal effect with the dispersant injection considering the applied environments, the iron oxide concentration and the concentration ratio of dispersant to iron oxide.