• 제목/요약/키워드: Initial slope

검색결과 351건 처리시간 0.042초

등척성 운동 시 요추의 각도에 따른 중앙주파수와 토크의 특성 (Characteristics of EMG Median Frequency and Torque in Relation to Low Back Angle During Isometric Back Extension Exercise)

  • 박경희;권오윤;장근;강성재;김영호
    • 한국전문물리치료학회지
    • /
    • 제8권2호
    • /
    • pp.41-54
    • /
    • 2001
  • Fatigue is the decline in force produced as a result of prolonged muscle activity. Localized muscle fatigue can be identified by a shift toward low in the frequency components of the EMG signal, typically represented by a fall in the median frequency. Previous studies show that a shortened muscle develops a higher fatigue than elongated muscles. The purpose of this study was to investigate the time-related change of median frequency and torque during maximal isometric back extension exercises at different exercise angles ($0^{\circ}$, $12^{\circ}$, $36^{\circ}$, $72^{\circ}$). Twenty healthy subjects (mean age = $24.35{\pm}2.70$) were evaluated in this study. Median frequency was extracted from the EMG signals by fast Fourier transform (FFT). Initial median frequency and the slope of median frequency change over time were computed from linear regression analysis. Pearson's product moment correlation was used to quantify the relationship between slope of median frequency and torque. The results were as follows: 1) Significant differences in y-intercepts of torque regression equation with respect to exercise angle were shown. However, there were no differences in the slopes of the median frequency and torque, and y intercept of the median frequency among exercise angles. 2) There was no significant correlation between slope of median frequency and torque. 3) But there was moderate correlation between median frequency and torque at each exercise angle. In conclusion, the exercise angle during maximal isometric back extension exercise is not a direct effect on slope of median frequency and torque. But results showed that median frequency and torque shift were highly correlated in all subjects.

  • PDF

상시 계측시스템을 이용한 붕괴 절토사면 거동 특성 분석 및 안정성 해석 (The Stability and Characteristic Analysis of Cut Slope Behavior using Real-time Monitoring System)

  • 백용;구호본;장기태;유병선;배규진
    • 지질공학
    • /
    • 제14권1호
    • /
    • pp.71-80
    • /
    • 2004
  • 토사면의 붕괴는 매년 해빙기와 여름철 집중호우기에 자주 발생한다. 본 연구는 지반의 거동에 대한 원인을 분석하고 향후 사면 붕괴의 거동을 예측하기 위하여 상시 계측시스템을 도입한 현장에서 수집된 자료를 해석한 것이다. 연구방법으로 현장조사와 계측결과를 종합적으로 검토하여 붕괴 규모 및 붕괴 메카니즘을 분석하였다. 또한, 현장에 설치된 상시 계측시스템 전송 자료 분석과 수반하여 안정성 해석을 수행하였다. 본 절토사면은 총 17개의 신축계 센서를 설치하여 계측을 실시하였으며, 그 결과, 총 3회의 지반 변위가 발생하였고 부분적으로 다수의 인장균열이 발생하였다. 사암과 세일로 구성된 본 절토사면에서 집중호우와 하부 지지력 상실에 기인하여 초기 거동이 시작되었다. 지반거동 특성의 정량적 분석을 위하여 총 5개의 측선을 구성하여 계측을 실시하였다. 계측결과를 종합하여 보면 대책공법이 기 시공된 구간에서는 매우 미미한 변이가 발생되었으나, 대책방안이 마련되지 않은 구간에서는 최대 400mm이상의 변위가 진행되고 있다. 변위 자료와 강우자료의 분석결과 지반의 거동과 강우와는 밀접한 관계가 있는 것으로 판단되었다. 지반의 포화도를 변화하면서 안정성 해석을 실시한 결과, 지반 포화도가 55%이상 일때부터 안전율이 1.0이하로 나타나는 것을 알 수 있다. 현재의 지반거동 추이는 오차 범위내에 속하는 안정한 단계로 판단되어지나, 향후 동절기의 외부온도 변화와 동반하여 지반의 변동이 우려되므로 인하여 지속적인 관찰과 자료 분석이 수행되어야 할 것으로 판단된다.

Bonding between high strength rebar and reactive powder concrete

  • Deng, Zong-Cai;Jumbe, R. Daud;Yuan, Chang-Xing
    • Computers and Concrete
    • /
    • 제13권3호
    • /
    • pp.411-421
    • /
    • 2014
  • A central pullout test was conducted to investigate the bonding properties between high strength rebar and reactive powder concrete (RPC), which covered ultimate pullout load, ultimate bonding stress, free end initial slip, free end slip at peak load, and load-slip curve characteristics. The effects of varying rebar buried length, thickness of protective layer and diameter of rebars on the bonding properties were studied, and how to determine the minimum thickness of protective layer and critical anchorage length was suggested according the test results. The results prove that: 1) Ultimate pull out load and free end initial slip load increases with increase in buried length, while ultimate bonding stress and slip corresponding to the peak load reduces. When buried length is increased from 3d to 4d(d is the diameter of rebar), after peak load, the load-slip curve descending segment declines faster, but later the load rises again exceeding the first peak load. When buried length reaches 5d, rebar pull fracture occurs. 2) As thickness of protective layer increases, the ultimate pull out load, ultimate bond stress, free end initial slip load and the slip corresponding to the peak load increase, and the descending section of the curve becomes gentle. The recommended minimum thickness of protective layer for plate type members should be the greater value between d and 10 mm, and for beams or columns the greater value between d and 15 mm. 3) Increasing the diameter of HRB500 rebars leads to a gentle slope in the descending segment of the pullout curve. 4) The bonding properties between high strength steel HRB500 and RPC is very good. The suggested buried length for test determining bonding strength between high strength rebars and RPC is 4d and a formula to calculate the critical anchorage length is established. The relationships between ultimate bonding stress and thickness of protective layer or the buried length was obtained.

오수관 설계유량 산정법이 설계유속에 미치는 영향 (Design Flow Velocity Changes According to the Design Flow Determination Methods in the Sanitary Sewer)

  • 현인환;원승현;김형준;이제인
    • 상하수도학회지
    • /
    • 제19권6호
    • /
    • pp.749-757
    • /
    • 2005
  • The present study analyzed actual cases of designed flow estimation method and designed flow rate of sewage pipe lines. In order to examine the effects of peak-hour demand factor estimation with given daily highest peak loading, we analyzed its effects on designed flow rate with changing the peak-hour demand factor from 2.0 to 10.0. The results of this study are as follows. When reviewing the recent designs, we found that 59.4% of pipe line with 250mm and 300mm diameter, which fall under minimum allowable pipeline did not meet the minimum velocity which is specified as 0.6m/sec in design standards. The pipe line that have minimal access population or have very low slope did not satisfy the minimum velocity. In estimating the designed sewage flow, the applied daily highest peak loading and hourly highest peaking loading were the load factor for the entire population of the planned area, and for the peak loading of the initial pipes connected to a very small population, we applied the same factor as that applied to the entire area and, as a result, the hourly highest flow was underestimated. Because, in case of the initial pipes, the method of applying the same peak loading to all subject areas is highly possible to produce underestimated design flow, when estimating the designed flow of the initial pipes connected to a small population need to adopt a rational flow factor according to the size of population. For this, it is considered to investigate and analyze raw data on daily and hourly variation of sewage flow.

건축물 외관의 오염방지를 위한 계획적 방안 연구 - 서울시 구청을 대상으로 - (A Study on the Planning Methods for Pollution Prevention of Building Exterior - Focused On the Public Borough Offices in Seoul -)

  • 최명환;최문규
    • 대한건축학회논문집:계획계
    • /
    • 제36권4호
    • /
    • pp.71-81
    • /
    • 2020
  • The purpose of this study is to propose the planning methods for pollution prevention in the initial design stage by identifying the pollution phenomena on the exterior of the building. It is important to catch the problem early on because exterior troubles begin with an initial design defect and causes rapid aging. The scope of this study is seoul public borough offices that should be sustainable for long as landmark located at the center of the district. Field survey was conducted three times in six months. Twenty-six borough offices were diagnosed with three levels of contamination through visual inspection and the contaminated locations, types, materials, and characteristics were checked. Fourteen common contaminated locations were identified in the first and intensively rechecked in the second. Five locations vulnerable to contamination were designated and the contamination and cleanliness situations were checked by location in the third. As a result, main polluted types and locations are sloping wall, upper wall, protruded wall, canopy, and wall under window. The key to avoiding these pollution problems is to minimize the horizontal plane on which dust can be deposited. In other words, it can be considered variously by shape and location, such as the slope of the horizontal plane, the floating of the surface, the installation of the roof surface, and the vertical louvers. And throating plans and material plans suitable for each location are presented. Various methods of the shape and location, material are expected to use as useful basic data for preventing pollutions during the initial design stage.

연속체 암반비탈면의 강도정수 산정 연구 (A Study on Estimating Shear Strength of Continuum Rock Slope)

  • 김형민;이수곤;이벽규;우재경;허익;이준기
    • 한국지반공학회논문집
    • /
    • 제35권5호
    • /
    • pp.5-19
    • /
    • 2019
  • 암반으로 구성되어 있는 급경사($65^{\circ}{\sim}85^{\circ}$)비탈면이 장기간 안정한 상태로 유지되고 있는 자연현상을 고려할 때, 설계 및 초기 시공 단계에서 위와 유사한 지반 상태로 이루어진 깎기 암반비탈면에 대해 1:0.5(발파암 경사 기준)보다 급한 경사를 적용할 수 있을 것이다. 급경사로 설계 가능한 양호한 연속체 암반비탈면의 안정성을 검토하는 과정에서, 설계실무 측면에서 범용적인 암반강도정수 산정방법이 필요하게 되었다. Hoek 등(2002)이 수정 보완하여 발표한 Hoek-Brown 파괴기준과 GSI분류는 불연속구조의 영향을 충분히 고려한 암반특성화 시스템으로 평가되었으며, 응력변화에 따라 등가 Mohr-Coulomb 강도정수(등면적법)를 산출하는 방법을 제안하였다. 비탈면에서는 등가 M-C 강도정수가 최대구속응력(${{\sigma}^{\prime}}_{3max}$ 또는 수직응력)변화에 따라 민감하게 변화하므로 실무적으로 활용하기에 어려운 점이 있다. 이 연구에서는 양호한 연속체 암반비탈면에 대해 최대구속응력 범위이내에서 범용적으로 적용할 수 있는 강도정수산정방법(등각분할법)을 H-B 파괴기준을 응용하여 제안한다. 등각분할법 강도정수(A)의 타당성 및 적용성을 평가하기 위해, 연구대상 암반비탈면을 기존 실시설계 현장 인근에 있는 급경사 비탈면에서 암석종류별(화성암, 변성암, 퇴적암)로 선정하고, Hoek이 제시한 등가 M-C 강도정수(등면적법)들과 비교 분석하였다. 등면적법 및 등각분할법 등가 M-C 강도정수는 기본적인 자료인 기존 실시설계 현장의 실내 암석 삼축압축시험과 연구대상 암반비탈면의 불연속구조의 특성조사(Face Mapping)를 통해 RocLab 프로그램(H-B 파괴기준을 기본으로 전산화된 지반정수 산정 소프트웨어)을 활용하여 산정하였다. 산정된 등면적법 등가 M-C 강도정수는 상호 연동되어 점착력과 내부마찰각이 아주 크거나($45^{\circ}$ 이상) 작게 나타났다. 등각분할법 등가 M-C 강도정수는 등면적법 등가 M-C 강도정수의 중간 정도이며, 내부마찰각은 $30^{\circ}{\sim}42^{\circ}$의 범위를 보인다. 연구대상 암반비탈면의 등각분할법 강도정수(A)와 기존 실시 설계 현장에서 연구대상 암반비탈면과 유사한 암반상태(동일 등급 RMR)에 적용한 강도정수(B)와 비교 분석하고, 이 지반정수들로 적용한 비탈면 안정해석(한계평형해석과 유한요소해석) 결과를 통해 제안한 등각분할법의 적용성을 간접적으로 평가하였다. A와 B의 강도정수 차이는 10% 정도이다. 한계평형해석 결과(우기 기준), A적용 안전율(Fs)=14.08~58.22(평균 32.9), B적용 안전율(Fs)=18.39~60.04(평균 32.2)이며, 각 동일한 암석종류에 따라 상호 유사하게 나타났다. 유한요소 해석 결과, A적용 변위=0.13~0.65mm(평균 0.27mm), B적용 변위=0.14~1.07mm(평균 0.37mm)으로 매우 유사하다. H-B 파괴기준을 응용하여 등각분할법으로 산출한 지반 정수를 실무적인 전단강도로 적용할 수 있는 적용성 평가에서 유의미한 결과를 확인할 수 있었다.

주문진 표준사의 상대밀도에 따른 불포화 투수계수함수 산정 (Estimation on Unsaturated Hydraulic Conductivity Function of Jumoonjin Sand for Various Relative Densities)

  • 송영석
    • 대한토목학회논문집
    • /
    • 제33권6호
    • /
    • pp.2369-2379
    • /
    • 2013
  • 불포화 조건에서 흙의 초기 밀도에 따라 흙-함수특성곡선이 변화시키게 되며, 이로 인하여 불포화 조건에서 투수특성도 변화하게 된다. 이에 대한 영향을 고찰하기 위하여 상대밀도 40%, 60% 및 75%의 주문진 표준사에 대한 건조 및 습윤과정에서의 흙-함수특성곡선(SWCC)과 불포화 투수계수함수를 산정하였다. van Genuchten (1980)의 방법을 이용하여 흙-함수특성곡선(SWCC)을 산정한 결과 공기유입값과 관계된 계수 ${\alpha}$는 습윤과정에서 더 큰 값을 가지며, 변곡점의 경사에 관계된 계수 n과 잔류함수비에 관계된 계수 m은 건조과정에서 더 큰 값을 갖는다. 그리고 상대밀도가 증가할수록 공기함입치는 증가하지만 수분함입치는 감소하며, 동일한 상대밀도에서 공기함입치는 수분함입치보다 크게 발생된다. 한편, 계수추정방법 가운데 하나인 van Genuchten (1980)의 방법을 적용하여 불포화 투수계수함수를 산정한 결과 불포화 투수계수는 포화시 투수계수로 일정하게 유지되다가 공기함입치 혹은 수분함입치 직전에 급격하게 감소하는 것으로 나타났다. 건조과정에서의 포화투수계수는 습윤과정에서의 포화투수계수보다 크게 나타나며, 상대밀도가 증가함에 따라 건조 및 습윤과정에서의 포화투수계수는 감소한다. 실험결과에 의하면 주문진 표준사의 초기 간극비에 따라 흙-함수특성곡선(SWCC)에서의 공기함입치(AEV)는 감소하고 포화투수계수는 증가하므로, 흙-함수특성곡선(SWCC)과 불포화 투수계수함수(HCF)는 초기 간극비에 영향을 받는 것으로 나타났다.

여성 독거노인의 우울에 관한 연구: 전기와 후기노인의 비교를 중심으로 (A Study of Depression in Female Seniors Living Alone: A Comparison Between the Young-old and the Old-old Adults)

  • 임진섭;김제선
    • 산업융합연구
    • /
    • 제22권1호
    • /
    • pp.149-162
    • /
    • 2024
  • 본 연구는 우리사회에서 가장 취약한 집단이라고 할 수 있는 여성 독거노인을 대상으로 이들의 우울이 시간의 흐름에 따라 어떠한 변화패턴을 갖는지 그리고 이러한 우울에 영향을 미치는 요인이 무엇인지를 규명하기 위한 종단연구이다. 동시에 본 연구에서는 동일한 노인일지라도 연령에 따른 차이가 크다는 점을 고려하여 여성 독거노인을 전기(the young-old)와 후기노인(the old-old)으로 구분하여 각 집단의 우울에 영향을 미치는 예측요인이 서로 어떠한 차이가 발생하는지를 확인하였다. 주요 분석결과를 살펴보면 다음과 같다. 첫째, 여성 독거노인의 우울은 시간이 지나면서 감소하는 패턴을 갖는 것으로 나타났다. 조건적 모형에서 여성 독거노인의 우울궤적의 초기수준에 영향을 미치는 요인을 살펴보면 그 외 도시보다는 대도시 지역에 사는 노인이, 주관적 건강상태가 좋을수록, 운동을 하지 않는 노인이 초기 우울값이 낮은 것으로 나타났다. 다음으로 여성 독거노인의 우울의 변화율(기울기)에 영향을 미치는 요인을 살펴본 결과, 연령이 높을수록, 대도시에 사는 노인이, 주관적 건강상태가 좋을수록, 친교활동이 적을수록, 사회활동을 많이 할수록 우울수준이 큰 폭으로 감소하는 것으로 나타났다. 마지막으로 여성 독거노인의 우울의 초기값과 기울기에 영향을 미치는 경로에 전기노인과 후기노인 사이에 일부 차이가 있는 것으로 나타났다. 구체적인 내용을 살펴보면, 후기노인의 경우 초기에 사회활동 참여정도가 높을수록 우울의 변화폭은 커지는 반면 전기노인은 유의미한 영향관계가 없었다. 전기노인이 후기노인 보다 초기 주관적 건강상태가 양호할수록 우울의 변화폭이 컸다. 후기노인에게서만 초기에 주기적으로 운동을 하는 노인이 그렇지 않은 노인에 비해 초기 우울값이 높았다. 이상의 분석결과를 바탕으로 여성 독거노인의 우울을 감소시키기 위한 제언을 제시하였다.

STELLAR CONTENTS AND GLOBULAR CLUSTER CANDIDATES IN THE SCULPTOR GROUP GALAXY NGC 300

  • KIM SANG CHUL;SUNG HWANKYUNG;LEE MYUNG GYOON
    • 천문학회지
    • /
    • 제35권1호
    • /
    • pp.9-28
    • /
    • 2002
  • We present UBVI CCD photometry of the stellar contents and globular cluster(GC) candidates in the spiral galaxy NGC 300 in the Sculptor group. Color-magnitude diagrams for 18 OB associations having more than 30 member stars are presented. The slope of the initial mass function for the bright stars in NGC 300 is estimated to be ${\Gamma}= -2.6{\pm} 0.3$. Assuming the distance to NGC 300 of (m - M)o = 26.53 $\pm$ 0.07, the mean absolute magnitude of three brightest blue stars is obtained to be < $M_v^{BSG}$ (3) > = -8.95 mag. We have performed search for GCs in NGC 300 and have found 17 GC candidates in this galaxy. Some characteristics of these GC candidates are discussed.

두 회귀직선의 평행성에 대한 로버스트 검정 (A robust test for the parallelism of two regression lines)

  • 남호수;송문섭;신봉섭
    • 응용통계연구
    • /
    • 제8권2호
    • /
    • pp.77-86
    • /
    • 1995
  • 본 논문에서는 두 회귀직선의 평행성에 대한 로버스트 검정법을 제안하고, 모의실험과 예를 통하여 기존의 방법들과 유의수준의 안정성 및 검정력의 측면에서 비교하였다. 제안된 검정법은 Song et al. (1994b)에 의하여 제안된 최소절사제곱 추정량을 초기치로 하는 일단계 GM-추정량에 기초를 두고 있다. 이 추정량은 최대붕괴점과 유계영향함수를 갖는 것으로 알려져 있다.

  • PDF