• Title/Summary/Keyword: Initial fuel

Search Result 655, Processing Time 0.033 seconds

Analysis of Hydraulic Characteristics of Two Solenoid-driven Injectors for CRDi System (2개 솔레노이드 구동방식별 CRDi용 인젝터의 유압 동특성 해석)

  • Lee, Jin-Wook;Lee, Jung-Hyup;Kim, Min-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.6
    • /
    • pp.140-147
    • /
    • 2011
  • The injection nozzle of an electro-hydraulic injector for the common rail Diesel fuel injection system is being opened and closed by movement of a injector's needle which is balanced by pressure at the nozzle seat and at the needle control chamber, at the opposite end of the needle. In this study, the slenoid actuator was considered as a prime movers in high pressure Diesel injector. Namely a solenoid-driven Diesel injector with different driving current types, as a general method driven by solenoid coil energy, has been applied with a purpose to develop the analysis model of the solenoid actuator to predict the dynamics characteristics of the hydraulic component (injector) by using the AMESim code. Aimed at simulating the hydraulic behavior of the solenoid-driven injector, the circuit model has been developed as a unified approach to mechanical modeling in this study. As this analytic results, we know the suction force and first order time lag for driving force can be endowed in solenoid-driven injector in controlling the injection rate. Also it can predict that the input current wave exerted on solenoid coil is the dominant factor which affects on the initial needle behavior of solenoid-driven injector than the hydraulic force generated by the constant injection pressure.

Performance Prediction according to Equivalence Ratio Change in Simulated-EGR Compression Ignition Engine Containing CO2 (CO2를 포함한 Simulated-EGR 압축착화엔진에서 당량비 변화에 따른 성능 예측)

  • Suh, Hyun Kyu
    • Journal of ILASS-Korea
    • /
    • v.25 no.1
    • /
    • pp.21-26
    • /
    • 2020
  • The objective of this work is to numerically reveal the effect of equivalence ratio change on the simultaneous reduction of NOX and soot emissions from the simulated-EGR compression ignition engine containing CO2. An experiment was conducted by using a single-cylinder common-rail injection system engine, an intake control system, and exhaust emissions analyzers. The numerical analysis results were validated under the same experimental conditions. To investigate the effect of equivalence ratio by simulated-EGR containing CO2, the O2, N2, and CO2 mole fraction were changed in the initial air conditions to the cylinder. The results were analyzed in terms of peak cylinder pressure, indicated mean effective pressure, indicated specific nitrogen oxide, and indicated specific soot. It was revealed that ignition delay characteristics and heat release rate (ROHR) characteristics were not significantly different according to the equivalence ratio. However, as the equivalence ratio increased from 0.68 to 0.83, the maximum combustion pressure and IMEP decreased by about 6.5% and 9.4%, respectively. In the case of ISFC, as is well known, the trend is opposite of IMEP. In the case of ISNO, as the equivalence ratio increased, less NO was generated, and as the equivalence ratio increased by 0.05, the ISSoot value of about 10% increased.

Formation of Uniform SnO2 Coating Layer on Carbon Nanofiber by Pretreatment in Atomic Layer Deposition (전처리를 이용한 탄소 나노 섬유의 균일한 SnO2 코팅막 형성)

  • Kim, Dong Ha;Riu, Doh-Hyung;Choi, Byung Joon
    • Journal of Powder Materials
    • /
    • v.25 no.1
    • /
    • pp.43-47
    • /
    • 2018
  • Carbon nanofibers (CNF) are widely used as active agents for electrodes in Li-ion secondary battery cells, supercapacitors, and fuel cells. Nanoscale coatings on CNF electrodes can increase the output and lifespan of battery devices. Atomic layer deposition (ALD) can control the coating thickness at the nanoscale regardless of the shape, suitable for coating CNFs. However, because the CNF surface comprises stable C-C bonds, initiating homogeneous nuclear formation is difficult because of the lack of initial nucleation sites. This study introduces uniform nucleation site formation on CNF surfaces to promote a uniform $SnO_2$ layer. We pretreat the CNF surface by introducing $H_2O$ or $Al_2O_3$ (trimethylaluminum + $H_2O$) before the $SnO_2$ ALD process to form active sites on the CNF surface. Transmission electron microscopy and energy-dispersive spectroscopy both identify the $SnO_2$ layer morphology on the CNF. The $Al_2O_3$-pretreated sample shows a uniform $SnO_2$ layer, while island-type $SnO_x$ layers grow sparsely on the $H_2O$-pretreated or untreated CNF.

Optimized Trim and Heeling Adjustment by Using Heuristic Algorithm (휴리스틱 알고리즘을 이용한 트림 및 힐링 각도 조절 최적화)

  • HONG CHUNG You;LEE JIN UK;PARK JE WOONG
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.62-67
    • /
    • 2004
  • Many ships in voyage experience weight and buoyancy distribution change by various reasons such as change of sea water density and waves, weather condition, and consumption of fuel, provisions, etc . The weight and buoyancy distribution change can bring the ships out of allowable trim, heeling angle. In these case, the ships should adjust trim and heeling angle by shifting of liquid cargo or ballasting, deballasting of ballast tanks for recovery of initial state or for a stable voyage. But, if the adjustment is performed incorrectly, ship's safety such as longitudinal strength, intact stability, propeller immersion, wide visibility, minimum forward draft cannot be secured correctly. So it is required that the adjustment of trim and heeling angle should be planned not by human operators but by optimization computer algorithm. To make an optimized plan to adjust trim and heeling angle guaranteeing the ship's safety and quickness of process, Uk! combined mechanical analysis and optimization algorithm. The candidate algorithms for the study were heuristic algorithm, meta-heuristic algorithm and uninformed searching algorithm. These are widely used in various kinds of optimization problems. Among them, heuristic algorithm $A^\ast$ was chosen for its optimality. The $A^\ast$ algorithm is then applied for the study. Three core elements of $A^\ast$ Algorithm consists of node, operator, evaluation function were modified and redefined. And we analyzed the $A^\ast$ algorithm by considering cooperation with loading instrument installed in most ships. Finally, the algorithm has been applied to tanker ship's various conditions such as Normal Ballast Condition, Homo Design Condition, Alternate Loading Condition, Also the test results are compared and discussed to confirm the efficiency and the usefulness of the methodology developed the system.

  • PDF

Investigation of Thermal Management Parameters of Metal Hydride Based Hydrogen Storage System (금속수소화물 기반 수소저장시스템의 열관리 인자 조사)

  • PARK, CHU SIK;KIM, JONG WON;BAE, KI KWANG;JEONG, SEONG UK;KANG, KYOUNG SOO
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.3
    • /
    • pp.251-259
    • /
    • 2018
  • Metal hydride based hydrogen storage under moderate temperature and pressure gives the safety advantage over the gas and liquid storage methods. Still solid-state hydrogen storage including metal hydride is below the DOE target level for automotive applications, but it can be adapted to stationary or miliary application reasonably. In order to develop a modular solid state hydrogen storage system that can be applied to a distributed power supply system composed of renewable energy - water electrolysis - fuel cell, the heat transfer and hydrogen storage characteristics of the metal hydride necessary for the module system design were investigated using AB5 type metal hydride, LCN2 ($La_{0.9}Ce_{0.1}Ni_5$). The planetary high energy mill (PHEM) treatment of LCN2 confirmed the initial hydrogen storage activation and hydrogen storage capacity through surface modification of LCN2 material. Expanded natural graphite (ENG) addition to LCN2, and compression molding at 500 atm improved the thermal conductivity of the solid hydrogen storage material.

CFD Simulation for Mixture Characteristic of DME-Propane Liquified Fuels (DME-Propane 액화연료의 혼합특성에 대한 CFD 시뮬레이션)

  • Kim, Cha-Hwan;Chun, Seuk-Hoon;Shin, Dong-Woo;Kim, Lae-Hyun;Lee, Hyun-Chan;Baek, Young-Soon
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.328-333
    • /
    • 2012
  • In this study, CFD simulation was performed with commercial CFD code FLUENT for the 3D mixing tank model (1 m in a diameter and 2.5 m in a height) of DME-Propane liquified fuels. Initial condition set-up with existence of DME 146 l at the upper side of mixing tank and Propane 770 l at the lower side of mixing tank. Characteristics of mixture and fluid flow were observed for 34 hours simulation. Two liquid fuel were uniformly mixed within range of 3 mol% after 24 hours, and range of 1 mol% after 34 hours. The simulation result following 4 hours was verified with KOGAS experimental data.

Production of Methanol by Resting Cells of Methylosinus trichosporium OB3b (Methylosinus trichosporium OB3b를 이용한 메탄올의 생산)

  • 박성훈;추석열
    • KSBB Journal
    • /
    • v.8 no.4
    • /
    • pp.341-350
    • /
    • 1993
  • As an effort to develop an alternative transportation fuel, the production of methanol from methane gas was studied using the resting cells of an obligatory methanotroph, Methylosinus trichosporium OB3b. The reaction was carried out in high concentration phosphate buffer solutions with the flask-grown cells containing the exclusively cytoplasmic methane monooxygenase (sMMO) activity. The methanol accumulation rate was observed to be 79nmo1/mg·min during the initial 4.5hr. Phosphate-dependent inhibition was found for both sMMO and methanol dehydrogenase (MDH) activities, and the inhibition constants were 185mM and 42mM, respectively. The inhibition mode was noncompetitive. Methanol was found to be very inhibitory to the sMMO activity and the inhibition constant (noncompetitive) was 21mM when propylene was used as substrate. The sMO activity in the resting cells was declined very fast and the rate became very high during the methanol production. These results indicate that the use of M. trichosporium OB3b as a biocatalyst for the methanol production is heavily dependent on the stable maintenance of the whole-cell SMO activity as well as the effective alleviation of product inhibition.

  • PDF

A Study on the isomerization reactions of Tricyclopentadiene Derivatives using aluminum chloride($AlCl_3$) catalyst(I) (알루미늄클로라이드 촉매를 이용한 Tricyclopentadiene 유도체의 이성화 반응 연구(I))

  • Joo, Hyun-Hye;Joo, Hyeong-Uk;Park, Chang-Sun;Han, Jeong-Sik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.800-803
    • /
    • 2010
  • Tetrahydrotricyclopentadiene(below THTCPD) isomer is a good candidate for the high performance liquid fuel component because of high density and heat of combustion value. But it has bad fluidity. The object of this study was to find out the optimal reaction condition to improve the fluidity of THTCPD because initial reactant is solid state, So we have carried out isomerization reactions using aluminum chloride catalyst under varying the reaction condition such as reaction temperature and reaction solvents. The results showed that when using aluminum chloride catalyst, isomerization reaction was more active in dichloromethane(methylene chloride: MC), 1,2-dichloroethane(ethylene chloride: EC) and chloroform than n-hexnae and toluene and was effected by reaction temperature.

  • PDF

Influence of Critical Point of Jet Injected into Near-Critical Environment on Phase Change (근임계 환경으로 분사되는 제트의 임계점이 상변화에 미치는 영향)

  • Yoon, Taekyung;Shin, Dongsoo;Son, Min;Shin, Bongchul;Koo, Jaye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.475-481
    • /
    • 2017
  • In this paper, high speed camera images were used to analyze the supercritical injection behavior of liquid hydrocarbon compounds used as main components of propellant fuel. Decane and Methylcyclohexane (MCH), which have different critical points among kerosene constituents, were selected as experimental fluid and Shadowgraphy technique was used for the analysis. The difference in the temperature variation from the initial injector state of the subcritical condition until the vaporization occurs was represented by the different behaviors of Decane and MCH. However, under the Supercritical conditions, the enthalpy of vaporization near the critical point approaches zero and the phase change to the Supercritical phase occurs instead of vaporization process. In the phase change of the Supercritical system, there was no rapid density change, so the liquid state image was observed in both the Decane and MCH.

  • PDF

Analysis of the Economic Efficiency of the District Heating and Gas Engine Co-Generation System Compared with the Central Heating System (중앙난방방식을 지역난방과 소형열병합난방 방식으로 전환 시 경제성 비교 분석)

  • Kim, Kyu Saeng
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.544-551
    • /
    • 2015
  • This study was conducted to determine the LCC of apartment complexes with district heating and a cogeneration system. For the purpose of analyzing LCC according to the size of the apartment complex, 500, 1,500, and 4,000-unit model apartments were selected. Analysis was performed on the design of the heating system and the life cycle cost including total construction cost, maintenance and operation cost for the duration of the project period (15 years). According to the calculated results, 1) The initial cost of the cogeneration system for 500, 1,500, and 4,000-unit apartments is higher than that of the district heating system by 20%, 13%, and 12%, respectively. 2) In the case of the cogeneration system, the payback period by electric generation was found to be 5.21, 4.92 and 4.47 years, and saving cost was calculated to be 29 billion won, 94 billion won and 262 billion won after the payback period for 500, 1,500, and 4,000-unit apartments, respectively. 3) The LCC values of the cogeneration system were 1.12, 1.07 and 1.06 times larger than those of the district system according to the size of the apartment complex. In this study, the district heating system was found to be more efficient than the cogeneration system in terms of LCC reduction. 4) District heating is affected by fuel bills, so energy efficiency should be improved through recovering waste heat (incineration heat, etc.). Also, district cooling should be provided according to heat use to keep the temperature high in winter and low in summer.