• Title/Summary/Keyword: Initial Response

Search Result 1,781, Processing Time 0.025 seconds

Adsorption Characterization of Cd by Activated Carbon containing Hydroxyapatite using Response Surface Methodology (RSM) (반응표면분석법을 이용한 Hydroxyapatite 첨가 활성탄에서의 Cd 흡착특성에 관한 연구)

  • An, Sang-Woo;Yoo, Ji-Young;Choi, Jae-Young;Park, Jae-Woo
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.943-950
    • /
    • 2009
  • Cadmium (Cd) adsorption onto the activated carbon containing hydroxyapatite (HAP) was investigated in batch experiments and response surface methodology (RSM) using the Box-Behnken methods were applied to the experimental results. Cd adsorption with different HAP mass ratio of from 10% to 30%. With more HAP, Cd was more adsorbed. These results suggest that the higher HAP mass causes an increase of the ion exchange potential of the HAP sorbent. Equilibrium experimental results from Cd adsorption was fitted to Langmuir and Freundlich isotherm models. Cd adsorption on HAP sorbent were found to follow the Freundlich isotherm model well in the initial adsorbate concentration range. Also, Cd adsorption was a function of the HAP mass ratio ($x_1$), initial Cd concentration ($x_2$), and initial pH ($x_3$) from the application of the RSM. Statistical results showed the order of significance of the independent variables to be initial Cd concentration > HAP mass ratio > initial pH.

Study on Effective Arrangement of Main Engine Top-Bracing (메인 엔진 탑-브레이싱의 효과적 배치에 관한 연구)

  • Choung, Joon-Mo;Min, Dug-Ki
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.4
    • /
    • pp.289-298
    • /
    • 2011
  • This paper provides procedures to effectively determine arrangement of hydraulic type top-bracings, which are popular for the main engine of the mid and large sized commercial vessels. Analyzing the operation mechanism of hydraulic top-bracing, ideal unified nonlinear stiffness curve is presented for linear frequency response analysis and nonlinear transient response analysis. Nonlinear stiffnesses of the curve are determined based on the regression analysis of test results. It is noted from linear frequency response analysis, initial setting pressure is most important among the setting values of the other stiffness intervals. From transient response analyses for two top-bracing arrangement scenarios, it is recognized that, as far as initial setting pressure is well controlled for the concerning vessels, only two top-bracings are enough to suppress H-mode excitation forces from main engine.

Rate-dependent shearing response of Toyoura sand addressing influence of initial density and confinement: A visco-plastic constitutive approach

  • Mousumi Mukherjee;Siddharth Pathaka
    • Geomechanics and Engineering
    • /
    • v.34 no.2
    • /
    • pp.197-208
    • /
    • 2023
  • Rate-dependent mechanical response of sand, subjected to loading of medium to high strain rate range, is of interest for several civilian and military applications. Such rate-dependent response can vary significantly based on the initial density state of the sand, applied confining pressure, considered strain rate range, drainage condition and sand morphology. A numerical study has been carried out employing a recently proposed visco-plastic constitutive model to explore the rate-dependent mechanical behaviour of Toyoura sand under drained triaxial loading condition. The model parameters have been calibrated using the experimental data on Toyoura sand available in published literature. Under strain rates higher than a reference strain rate, the simulation results are found to be in good agreement with the experimentally observed characteristic shearing behaviour of sand, which includes increased shear strength, pronounced post-peak softening and suppressed compression. The rate-dependent response, subjected to intermediate strain rate range, has further been assessed in terms of enhancement of peak shear strength and peak friction angle over varying initial density and confining pressure. The simulation results indicate that the rate-induced strength increase is highest for the dense state and such strength enhancements remain nearly independent of the applied confinement level.

Toxic Concentration(T-LOC) Endpoint Distance Study for Fire Brigade Protection in Response to Chemical Accidents (화학사고 초기대응 소방대 보호를 위한 독성농도(T-LOC) 끝점거리 연구)

  • Jong Chan Yun;Chul Hee Cho;Jeong Hun Won
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.6
    • /
    • pp.60-71
    • /
    • 2023
  • The purpose of this study is to propose a quantitative toxicity endpoint distance suitable for the initial response of firefighters by comparing and analyzing the commonly applied toxic level of concern (T-LOC), specifically emergency response planning guidelines (ERPG), acute exposure guideline levels (AEGL), and immediately dangerous to life or health (IDLH). This is to protect the fire brigade, which responds to toxic chemical accidents first during the golden time. Using areal locations of hazardous atmospheres, a damage prediction program, the amount of leakage for both acidic and basic substances, along with the endpoint distance, were analyzed for alternative accident and worst-case accident scenarios. The results showed that the toxicity endpoint distance, serving as a compromise between Level-3 and Level-2 of T-LOC, was longer than ERPG-3 and shorter than ERPG-2 with IDLH, while its values were analyzed in the order of ERPG-2, AEGL-2, IDLH, AEGL-3, and ERPG-3. It is suggested that the application of IDLH in an emergency (red card) and ERPG-2 endpoint distance in a non-emergency (non-red card) can be utilized for the initial response of the fire brigade.

Gamma Knife Surgery for Brain Metastasis from Renal Cell Carcinoma : Relationship Between Radiological Characteristics and Initial Tumor Response

  • Kim, Jin-Wook;Han, Jung-Ho;Park, Chul-Kee;Chung, Hyun-Tai;Paek, Sun-Ha;Kim, Dong-Gyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.2
    • /
    • pp.92-96
    • /
    • 2007
  • Objective : The authors have speculated that metastatic brain lesions from renal cell carcinoma (RCC) show diverse radiological patterns and tumor responses after Gamma knife surgery (GKS), and have hypothesized that these can be predicted from tumor radiological characteristics. The goal of the current study was to identify the radiological characteristics of RCC brain metastases and the predictors of initial radiosurgical response after GKS. Methods : A retrospective analysis was performed on 48 lesions in 18 patients with RCC brain metastasis treated by GKS. The radiological characteristics of these lesions in magnetic resonance images (MRI) were classified into 3 categories according to enhancement patterns in T1-weighted images and signal intensity characteristics in T2-weighted images. Responses to GKS were analyzed according to these categories, and in addition, other potential predictive factors were also evaluated. Results : MRI findings in the three categories were diverse, though numbers of the lesion were comparable. At 2-month MRI follow-ups after GKS, response rate was 54% and the local tumor control rate 83%. T2 signal intensity was found to be the principal predictive factor of response to GKS, namely negative predictive factor. Other variables such as age, sex, tumor volume, dose, duration from initial diagnosis to GKS, and previous systemic therapies failed to show significant relationships with treatment response by multivariate analysis. Conclusion : Careful evaluation of the radiological characteristics of brain metastases from RCC is important prior to GKS because MRI heterogeneity has predictive value in terms of determining initial tumor response.

Blast Analysis of Single Degree of Freedom Plant Structures Considering Static Displacement (정적변위를 고려한 플랜트 구조물의 단자유도 폭발 해석)

  • Lee, Jae-Kyoon;Lee, Seung-Hoon;Kim, Han-Soo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.5
    • /
    • pp.317-324
    • /
    • 2022
  • In this paper, an analysis method that considers the initial static displacement of structural members using an equivalent single-degree-of-freedom system is presented. Newmark's dynamic analysis algorithm was improved to consider the effect of the initial static displacements of structural members. The effect of the initial static displacement on the maximum response according to the assumed duration of the blast load and natural period of the member was investigated. The effects of positive and negative static displacements on the maximum dynamic responses of structural members subjected to a positively applied blast load were also studied. Modified response charts for the shock-type and pressure-type waves are presented so that static displacements can easily be considered. Using a design example, we demonstrate the significance of the modified response chart that considers the static displacement. Based on the results of this study, the maximum response of a the structural member can be easily obtained whilst considering its initial static displacement. The modified response chart presented in this study can be used for the structural design of plants and military facilities.

A Study on the Response Technique for Toxic Chemicals Release Accidents - Hydrogen Fluoride and Ammonia - (독성 화학물질 누출사고 대응 기술연구 - 불산 및 암모니아 누출을 중심으로 -)

  • Yoon, Young Sam;Cho, Mun Sik;Kim, Ki Joon;Park, Yeon Shin;Hwang, Dong Gun;Yoon, Jun heon;Choi, Kyung Hee
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.31-37
    • /
    • 2014
  • Since the unprecedented hydrogen fluoride leak accident in 2012, there has been growing demand for customized technical information for rapid response and chemical accident management agencies including the Ministry of Environment, the National Emergency Management Agency, and the National Police Agency need more information on chemicals and accident management. In this regard, this study aims to provide reliable technical data and guidelines to initial response agencies, similar to accident management technical reports of the US and Canada. In this study, we conducted a questionnaire survey and interviews on initial response agencies like fire stations, police stations, and local governments to identify new information items for appropriate initial response and improvements of current guidelines. We also collected and reviewed the Canada's TIPS, US EPA's hydrogen fluoride documents, domestic and foreign literature on applicability tests of control chemicals, and interview data, and then produced items to be listed in the technical guidelines. In addition, to establish database of on-site technical information, we carried out applicability tests for accident control data including ① emergency shut down devide, safety guard, shut down valve, ground connection, dyke, transfer pipe, scrubber, and sensor; ② literature and field survey on distribution type and transportation/storage characteristics (container identification, valve, ground connection, etc.); ③ classification and identification of storage/transportation facilities and emergency management methodslike leak prevention, chemicals control, and cutoff or bypass of rain drainage; ④ domestic/foreign analysis methods and environmental standards including portable detection methods, test standards, and exposure limits; and ⑤ comparison/evaluation of neutralization efficiency of control chemicals on toxic substances.

Improvement of Damage Range Calculation for First Response to Chemical Accidents (화학사고의 일차 대응을 위한 피해영향범위 산정 개선 방안)

  • Lee, Deok Jae;Ahn, Jae-Hyun;Song, Chang Geun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.59-65
    • /
    • 2017
  • Calculation of the damage impact of chemical accidents is an important element in site, and the initial isolation distance and the protective action distances are significant factors in coping the chemical accident. In this study, three major cities that represent each Province were selected, and the safety distances were calculated considering regional climate conditions. The results were compared with the prescribed values in Emergency Response Guidebook. It is concluded that the regional meteorological conditions such as temperature, vapour pressure, relative humidity, wind speed, and cloud cover should be reflected in estimating the initial isolation distance and the protective action distance.

Optimizing Conditions for the Growth and Bacteriocin Production of Lactococcus sp.HY 449 Usin Response Surface Methodology (반응표면 분석에 의한 Lactococcus sp. HY 449의 성장 및 Bacteriocin 생산의 최적화)

  • Kim, Sang-Kyo;Oh, Se-Jong;Lee, Sang-Jun;Baek, Young-Jin;Park, Yun-Hee
    • Microbiology and Biotechnology Letters
    • /
    • v.22 no.5
    • /
    • pp.522-530
    • /
    • 1994
  • Bacteriocin-producing lactic acid bacteria, Lactococcus sp. HY 449, was isolated from dairy products. Using response surface methodology, the various concentrations of medium compo- nents (tryptone, glucose, yeast extract, tween 80, and initial pH) were tested to find the optimum conditions for maximum bacteriocin production and growth of Lactococcus sp. HY 449. Central composite design was used to control the concentrations of medium components in the experiment. Bacteriocin production and cell growth of Lactococcus sp. HY 449 were most affected by glucose and yeast extract. Estimated optimum growth conditions of Lactococcus sp. HY 449 were as follows; tryptone 1.08%, glucose 1.129%, yeast extract 0.674%, tween 80 0.11%, and initial pH 7.19. Also estimated optimum conditions for bacteriocin production were tryptone 0.937%, glucose 1.108%, yeast extract 0.163%, tween 80 0.09%, and initial pH 6.98.

  • PDF

Establishment of Fire-Safety System that combines BIM technology for fire safety with drones and IT convergence technologies (화재안전을 위한 BIM기술과 드론 및 IT융복합 기술을 접목시킨 소방안전시스템 구축)

  • Kim, Dae-Geon;Lee, Gi-Hwi;Hong, Il-Hyeok;Kim, Min-Sung;Lee, Dong-Oun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.175-176
    • /
    • 2018
  • While damage caused by fire increases, awareness of fire is still low. Morever, Small fires often spread into big fires as they fail to keep the golden time due to the delay in initial response. In particular, the initial response is more important in areas where many unauthorized buildings are called " Panjachon " as firefighting facilities are insufficient compared to other residential facilities. Therefore, we will combine BIM technology, drones and IT convergence technologies to develop a firefighting safety information system that can speed up initial response and help combat fires.

  • PDF