• Title/Summary/Keyword: Initial Position

Search Result 1,070, Processing Time 0.024 seconds

Algorithm for a Initial Pole Position Estimation of PMLSM (영구자석 선형동기전동기의 초기각 추정 알고리즘)

  • Lee Young-Ho;Choi Jong-Woo;Kim Heung-Geun
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.104-108
    • /
    • 2003
  • This paper explained algorithm for a initial pole position estimation of a permanent magnet linear synchronous motor(PMLSM). Generally this motor is considered initial pole position with a position sensor such as incremental encoder for the precise initial pole position estimation and high performance. But this is based on the principle that the initial pole position is accomplished by the PI controller using the maximum values of a position error generated by the new proposed two reference frames and also by using a rated force for input. the proposed algorithm does not utilize the general methods such as impedance ratio, EMF and using the magnetic saturation. In other words, this can be applied without respect to variety of the motor structure because of insensitivity to the motor parameters. In conclusion, simulation results are presented to confirm performance of initial pole position estimation method.

  • PDF

Mathematical Analysis and Simulation Based Survey on Initial Pole Position Estimation of Surface Permanent Magnet Synchronous Motor

  • Kim, Tae-Woong;Wheeler, Patrick;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.499-506
    • /
    • 2009
  • In this paper, the initial pole-position estimation of a surface (non-salient) permanent magnet synchronous motor is mathematically analyzed and surveyed on the basis of simulation analysis, and developed for accurate servo motor drive. This algorithm is well carried out under the full closed-loop position control without any pole sensors and is completely insensitive to any motor parameters. This estimation is based on the principle that the initial pole-position is simply calculated by the reverse trigonometric function using the two feedback currents in the full closed-loop position control. The proposed algorithm consists of the predefined reference position profile, the information of feedback currents, speed, and relative position, and the reverse trigonometric function for the initial-pole position estimation. Comparing with the existing researches, the mathematical analysis is introduced to get a more accurate initial pole-position of the surface permanent magnet motor under the closed-loop position control. It is found that the proposed algorithm can be easily applied in servo drive applications because it satisfies the following user's specifications; accuracy and moving distance.

The Effect of Head Posture Change on Initial Occlusal Contact in Temporomandibular Disorder Patient (측두하악 장애환자에서 두부자세 변화가 초기 교합접촉에 미치는 영향)

  • Weon-Ho Choi;Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.489-496
    • /
    • 1995
  • The purpose of this study was to evaluate an effect of change on head posture initial occlusal contacts with measuring the distances between initial occlusal contacts and maximum intercuspal position at different head posture in TMDs patient. For this study, 24 patients from age 13 to 36 were selected, they were examined health history taken, patients who have sign and symptoms of TMDs were examine before the study. For the normal group, 21 adults from age 23 to 25 were selected. They have normal or class I molar relationship, and have no other prosthetic restorations. Difference on distance between initial occlusal contact and maximum intercuspal position with mandibular kinesiograph$(MKG^R)$(K6 diagnostic system, Myo-tronic Inc, USA) in upright, supine, 45$^{\circ}$ extension, 30$^{\circ}$ flexion position of the head were measured. The Frankfort horizontal plane was used as a reference plane. The results were as follows : 1. There were significant differences between initial occlusal contacts of the normal and patient group on upright position and 30$^{\circ}$ flexion of the head(p<0.05, p<0.01) 2. The position of the initial occlusal contacts have a tendency to place anterior and inferior to maximal intercuspal position in upright position and 30( flexion of the head as well as posterior and inferior in supine position and 45$^{\circ}$ extension of the head in the normal and patient groups. 3. There were significant differences among the initial occlusal contacts between uptight and supine position; upright and 45$^{\circ}$ extension of the head(p<0.05); supine position and 30$^{\circ}$ flexion of the head, .and 30(flexion and 45$^{\circ}$ extension of the head in the patient group(p<0.01) The result have shown that after treatment on the supine position, it may be necessary to check occlusal contact on the upright position as well ass flexion of the head. It may need careful adjustment in occlusal condition on upright position of TMDs patient.

  • PDF

A Study of Initial Pole Position Estimation for Interior Permanent Magnet Motor (매입형 영구자석 전동기의 초기 극위치 추정에 관한 연구)

  • Park, Chang-Soo;Lee, Geun-Ho;Nam, Hyuk;Lee, Ji-Young;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.955-957
    • /
    • 2003
  • In this paper deal with Initial Pole Position Estimation for Interior Permanent Magnet Motor. Generally, Brushless motor is considered Initial Pole Position with absolute encoder or resolver, etc. In the motor, the flux from the magnets is large enough to saturate the stator iron, results in different inductance values along the pole position. Based upon the relationship between magnitude of inductance and the resultant magnetic filed, initial pole position is estimated at standstill without position sensors, especially, this paper provide the direction of the magnetization. Finally, analysis results are presented to confirm ability of initial pole position estimation.

  • PDF

Compensation of Initial Position Error and Torque Ripple in Vector Control of Two-phase Hybrid Stepping Motors (2상 하이브리드 스테핑 모터의 벡터 제어 시 초기 각 오차 및 토크 리플 보상)

  • Do-Hyun, Kim;Sang-Hoon, Kim
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.6
    • /
    • pp.481-488
    • /
    • 2022
  • This study proposes compensation methods for the initial position error and torque ripple in vector control of two-phase hybrid stepping motors. Stepping motors have an asymmetrical structure due to misalignment, such as the eccentricity generated by the manufacturing and assembly process. When vector control is applied using the position information measured by an incremental encoder attached to the rotor shaft of such stepping motors, the following problems occur. First, an initial position error occurs during the forced excitation process for the initial rotor position alignment. Second, torque ripple corresponding to the mechanical rotation frequency is generated. In this study, these non-ideal phenomena that occur in vector control of the stepping motor are analyzed, and compensation methods are proposed to eliminate them. The validity of the proposed initial position error and torque ripple compensation methods is verified through experiments on a two-phase hybrid stepping motor drive system.

The Effect of Prosodic Position and Word Type on the Production of Korean Plosives

  • Jang, Mi
    • Phonetics and Speech Sciences
    • /
    • v.3 no.4
    • /
    • pp.71-81
    • /
    • 2011
  • This paper investigated how prosodic position and word type affect the phonetic structure of Korean coronal stops. Initial segments of prosodic domains were known to be more strongly articulated and longer relative to prosodic domain-medial segments. However, there are few studies examining whether the properties of prosodic domain-initial segments are affected by the information content of words (real vs. nonsense words). In addition, since the scope of domain-initial effect was known to be local to the initial consonant and the effects on the following vowel have been found to be limited, it is thus worth examining whether the prosodic domain-initial effect extends into the vowel after the initial consonant in a systematic way across different prosodic domains. The acoustic properties of Korean coronal stops (lenis /t/, aspirated /$t^h$/, and tense /t'/) were compared across Intonational Phrase, Phonological Phrase and Word-initial positions both in real and nonsense words. The durational intervals such as VOT and CV duration were cumulatively lengthened for /t/ and /$t^h$/ in the higher prosodic domain-initial positions. However, tense stop /t'/ did not show any variation as a function of prosodic position and word type. The domain-initial lenis stop showed significantly longer duration in nonsense words than in real words. But the prosodic domain-initial effect was not found in the properties of F0 and [H1-H2] of the vowel after initial stops. The present study provided evidence that speakers tend to enhance speech clarity when there is less contextual information as in prosodic domain-initial position and in nonsense words.

  • PDF

Improvement of Initial Rotor Position Detection for Permanent-Magnet Synchronous Motor Using Magnetic Position Sensor (영구자석형 동기전동기에서 자기식 위치 센서를 사용한 초기 회전자 위치 검출 성능의 개선)

  • Park, Mun-Su;Yoon, Duck-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.398-404
    • /
    • 2021
  • This paper proposes a method of using a magnetic position sensor to detect accurately the rotor position required to perform vector control of a permanent-magnet synchronous motor, particularly the initial rotor position at startup. In the existing vector control systems, the initial rotor position was determined using the output signals of the Hall sensors, or the control was performed in a sensorless method without using such a sensor. On the other hand, the accuracy is degraded due to the occurrence of a position detection error, and the practicality was not satisfactory. This paper attempts to detect the initial rotor position using a magnetic position sensor to solve this problem. This method is used to solve the deteriorating starting characteristics of the motor in the vector control system. In addition, to lower the price of a low-power vector control inverter, this paper proposes a method of integrating the existing sensors and reducing the price to less than half using a magnetic position sensor for speed and position detection.

The identification of Korean vowels /o/ and /u/ by native English speakers

  • Oh, Eunhae
    • Phonetics and Speech Sciences
    • /
    • v.8 no.1
    • /
    • pp.19-24
    • /
    • 2016
  • The Korean high back vowels /o/ and /u/ have been reported to be in a state of near-merger especially among young female speakers. Along with cross-generational changes, the vowel position within a word has been reported to render different phonetic realization. The current study examines native English speakers' ability to attend to the phonetic cues that distinguish the two merging vowels and the positional effects (word-initial vs. word-final) on the identification accuracy. 28 two-syllable words containing /o/ or /u/ in either initial or final position were produced by native female Korean speakers. The CV part of each target word were excised and presented to six native English speakers. The results showed that although the identification accuracy was the lowest for /o/ in word- final position (41%), it increased up to 80% in word-initial position. The acoustic analyses of the target vowels showed that /o/ and /u/ were differentiated on the height dimension only in word-initial position, suggesting that English speakers may have perceived the distinctive F1 difference retained in the prominent position.

Interior Central Pole Search Coils for Initial Rotor Position Detection of a Toroidal SRM (토로이달 SRM의 초기 회전자 위치검출을 위한 돌극 관통 서치코일)

  • 양형열;임영철
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.7
    • /
    • pp.473-482
    • /
    • 2004
  • In this paper, a detection technique of initial rotor position at a standstill in Toroidal Switched Reluctance Motor(TSRM) with built-in interior central pole search coil is proposed. In case search coils are used as a position sensor, it has many advantages like low cost, decrease in the volume, high robust characteristics and wide applications. However, the initial rotor position detection is very difficult because the search coil's EMF is not exist at a standstill. In this paper, a new detection method of initial rotor position is suggested using interior central pole search coil. The simulation and experiment for the proposed method and their results support the validity of the proposed scheme by verifying the operation of a 6/4 TSRM using search coils.

The Effect of Head Posture Change on Initial Occlusal Contacts (두부의 자세 변화가 초기 교합접촉에 미치는 영향)

  • Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.1
    • /
    • pp.195-204
    • /
    • 1995
  • The purpose of this study was to evaluate effect of head posture change on initial occlusal contacts through measuring the distances between initial occlusal contacts and maximum intercuspal position at different head posture. Two special devices were designed and constructed. Mandibular movement replicator was used to assess reliability of the K6 diagnostic system(MKG; Myo-tronic Inc, Seatle, USA) and head posture calibrator was used to maintain the constant head posture during experiment. We measured difference of distance between initial occlusal contact and maximum intercuspal position with MKG in upright, supine, 45 degrees extension, 30 degrees flexion, 30 degrees right and left bending postion of the head. The Frankfurt horizontal plane was used as a reference plane. 21 adults aged from 23 to 25 were selected, who have normal or class I molar relationship, and have no symptoms on TMJ and masticatory muscles, and have restorations less than 3 surfaces on each tooth, and have no other prosthetic restoration. The obtained results were as follows : The mean absolute distances between initial occlusal contact and maximum intercuspal postion were 0.39(0.18mm in the upright position, 0.65(0.37mm in the supine position, 0.59(0.33mm in the 45 degree extension, 0.70(0.53mm in the 30 degrees flexion, 1.12(1.10mm in the 30 degrees right bending and 1.94(0.67mm in the 30 degrees left bending of the head. The positions of the initial occlusal contacts have a tendency to locate anterior, left and inferior to maximal intercuspal position in upright position, posterior and inferior in supine position and 45 degrees extension, anterior and inferior in 30 degrees flexion, right and inferior in 30 degrees right bending, and left and inferior in 30 degrees left bending of the head. There were significant differences among the initial occlusal contacts in each head postures(P<0.0001). Therefore, we need to check initial occlusal contacts in the altered head posture during occlusal analysis and adjustment of occlusal appliance and dental occlusion for diagnosis and treatment of temporomandibular disorder.

  • PDF