• Title/Summary/Keyword: Infrared stress analysis

Search Result 61, Processing Time 0.023 seconds

Estimation of Dynamic Stress Concentration Factor by Infrared Thermography Stress Analysis (적외선 열화상 응력측정법에 의한 동적 응력집중계수 예측)

  • Choi, Man-Yong;Kang, Ki-Soo;Park, Jeong-Hak;Ahn, Byung-Wook;Kim, Koung-Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.5
    • /
    • pp.77-81
    • /
    • 2008
  • Structural components subjected to high frequency vibrations, such as those used in vibrating parts of gas turbine engines, are usually required to avoid resonance frequencies. Generally, the operating frequency is designed at more than resonance frequencies. When a vibrating structure starts or stops, the structure has to pass through a resonance frequency, which results in large stress concentration. This paper presents the transient thermoelastic stress analysis of vibrating cantilever beam using infrared thermography and finite element method (FEM). In FEM, stress concentration factor at the 2nd resonance vibration mode is calculated by the mode superposition method of ANSYS. In experiment, stress distributions are investigated with infrared thermography and dynamic stress concentration factor is estimated. Experimental result is agreed with FEM result within 10.6%. The advantage of this technique is a better immunity to contact problem and geometric limitation in stress analysis of small or micro structures.

Stress Analysis and Fatigue limit Evaluation of Plate with Notch by Lock-In Thermography (Lock-In Thermography를 이용한 노치시험편의 응력해석 및 피로한계치 평가)

  • Kim, Won-Tae;Kang, Ki-Soo;Choi, Man-Yong;Park, Jeong-Hak;Huh, Yong-Hak
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.315-320
    • /
    • 2006
  • This paper describes stress analysis and fatigue limit evaluation of plate with V-notch and hole-notch by lock-in infrared thermography. Temperature variation of a specimen under cyclic loading is negatively proportional to the sum of principle stress change and the surface temperature measured by infrared camera is calculated to the stress of notch specimens, based on thermoelastic equation. And also, fatigue limitation can be evaluated by the change of intrinsic energy dissipation. Fatigue limitation of two notch specimens is evaluated as 164 MPa and 185 MPa, respectively and the stress measured by Lock-in infrared Thermography show good agreement within 10% error.

ANALYSIS OF EFFECTIVE NUGGET SIZE BY INFRARED THERMOGRAPHY IN SPOT WELDMENT

  • Song, J.H.;Noh, H.G.;Akira, S.M.;Yu, H.S.;Kang, H.Y.;Yang, S.M.
    • International Journal of Automotive Technology
    • /
    • v.5 no.1
    • /
    • pp.55-59
    • /
    • 2004
  • Spot welding is a very important and useful technology in fabrication of thin sheet structures such as the parts in an automobile. However, because the fatigue strength of the spot welding point is considerably lower than that of the base metal due to stress concentration at the nugget edge, the nugget size must be estimated to evaluate a reasonable fatigue strength at a spot welded lap joint. So far, many investigators have experimentally studied the estimation of fatigue strengths of various spot weldments by using a destructive method. However, these destructive methods poses problems so testing of weldments by these methods are difficult. Furthermore, these methods cannot be applied to a real product, and are time and cost consuming, as well. Therefore, there has been a strong, continual demand for the development of a nondestructive method for estimating nugget size. In this study, the effective nugget size in spot weldments have been analyzed by using thermoelastic stress analysis adopting infrared thermography. Using the results of the temperature distribution obtained by analysis of the infared stress due to adiabatic heat expansion under sinusoidal wave stresses, the effective nugget size in spot welded specimens were estimated. To examine the evaluated effective nugget size in spot weldments, it was compared with the results of microstructure observation from a 5% Nital etching test.

Hot Spot Analysis on Brake Disc Using Infrared Camera (적외선카메라를 이용한 제동 디스크 열크랙 분석)

  • Kim, Jeong-Guk;Goo, Byeong-Choon;Kwon, Sung-Tae
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.964-968
    • /
    • 2008
  • Infrared thermography using high-speed infrared camera has been recognized as a powerful method for various potential applications, such as nondestructive inspection, failure analysis, stress analysis, and medical fields, due to non-contact, high-speed, and high spatial resolution at various temperature ranges. In this investigation, damage evolution due to generation of hot spots on railway brake disc was investigated using the infrared thermography method. A high-speed infrared camera was used to measure the surface temperature of brake disc as well as for in-situ monitoring of hot spot evolution. From the thermographic images, the observed hot spots and thermal damage of railway brake disc during braking operation were qualitatively analyzed. Moreover, in this investigation, the previous experimental and theoretical studies on hot spots phenomenon were reviewed, and the current experimental results were introduced and compared with theoretical prediction.

  • PDF

Phenotyping of Low-Temperature Stressed Pepper Seedlings Using Infrared Thermography

  • Park, Eunsoo;Hong, Suk-Ju;Lee, Ah-Yeong;Park, Jongmin;Cho, Byoung-Kwan;Kim, Ghiseok
    • Journal of Biosystems Engineering
    • /
    • v.42 no.3
    • /
    • pp.163-169
    • /
    • 2017
  • Purpose: This study was performed to evaluate the feasibility of using an infrared thermography technique for phenotype analysis of pepper seedlings exposed to a low-temperature environment. Methods: We employed an active thermography technique to evaluate the thermal response of pepper seedlings exposed to low-temperature stress. The temperatures of pepper leaves grown in low-temperature conditions ($5^{\circ}C$, relative humidity [RH] 50%) for four periods (6, 12, 24, and 48 h) were measured in the experimental setting ($23^{\circ}C$, RH 70%) as soon as pepper seedling samples were taken out from the low-temperature environment. We also assessed the visible images of pepper seedling samples that were exposed to low-temperature stress to estimate appearance changes. Results: The greatest appearance change was observed for the low-temperature stressed pepper seedlings that were exposed for 12 h, and the temperature from these pepper seedling leaves was the highest among all samples. In addition, the thermal image of low-temperature stressed pepper seedlings for 6 h exhibited the lowest temperature. Conclusions: We demonstrated that the leaf withering owing to the water deficiency that occurred under low-temperature conditions could induce an increase in temperature in plant leaves using the infrared thermography technique. These results suggested that the time-resolved and averaged thermal signals or temperatures of plants could be significantly associated with the physiological or biochemical characteristics of plants exposed to low-temperature stress.

Fatigue performance assessment of welded joints using the infrared thermography

  • Fan, J.L.;Guo, X.L.;Wu, C.W.
    • Structural Engineering and Mechanics
    • /
    • v.44 no.4
    • /
    • pp.417-429
    • /
    • 2012
  • Taking the superficial temperature increment as the major fatigue damage indicator, the infrared thermography was used to predict fatigue parameters (fatigue strength and S-N curve) of welded joints subjected to fatigue loading with a high mean stress, showing good predictions. The fatigue damage status, related to safety evaluation, was tightly correlated with the temperature field evolution of the hot-spot zone on the specimen surface. An energetic damage model, based on the energy accumulation, was developed to evaluate the residual fatigue life of the welded specimens undergoing cyclic loading, and a good agreement was presented. It is concluded that the infrared thermography can not only well predict the fatigue behavior of welded joints, but also can play an important role in health detection of structures subjected to mechanical loading.

Analysis on Thermoelastic Stress in the Cantilever Beam by Lock-in Thermography

  • Kang, K.S.;Choi, M.Y.;Park, J.H.;Kim, W.T.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.3
    • /
    • pp.273-278
    • /
    • 2008
  • In this paper, effects of thermoelastic stress by using lock-in thermography was measured in the cantilever beam. In experiment, a circular holed plate was applied to analyze variation of transient stress under the condition of repeated cyclic loading. And the finite element modal analysis as computational work was performed. According to the surface temperature obtained from infrared thermography, the stress of the nearby hole was predicted based on thermoelastic equation. As results, each stress distributions between 2nd and 3rd vibration mode were qualitatively and quantitatively investigated, respectively. Also, dynamic stress concentration factors according to the change of vibration amplitude were estimated for the resonance frequency.

A Study on Human Autonomic Nervous System Activities by Far-Infrared Ray Hyperthermia (원적외선 온열이 인체 자율신경기능에 미치는 영향에 관한 연구)

  • Park Chan-Ouk;Jang Yun-Ho;Min Se-Dong;Kang Se-Gu;Lee Chung-Keun;Lee Myoungho
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.623-628
    • /
    • 2004
  • This paper describes autonomic nervous system activities caused by hyperthermia of far-infrared ray on human body. Designed protocol and analysis algorithm were evaluated by experiments on 20 subjects to analyze the characteristic of heart rate variability(HRV) signals which could be analyzed by FFT power spectrum and time-frequency analysis. Using Poincare' plot analysis, LF and HF were compared with SD1 and SD2. During the experiment, subject was exposed to hyperthermic effects of far-infrared radiation. We could confirm that far-infrared ray, which was known to improve the blood circulation, stress state and enhancing thermal effect into human body, had an effect on human nervous system. As the hyperthermic temperature of far-infrared ray increased, the activity of cardiovascular system to sustain the homeostasis was observed by means of investigating the increase of the sympathetic activity.