• Title/Summary/Keyword: Infrared analysis

Search Result 2,249, Processing Time 0.029 seconds

Study on NDT Fault Diagnosis of the Ball Bearing under Stage of Abrasion by Infrared Thermography (마모 단계의 볼 베어링에 대한 적외선 열화상 비파괴 결함 진단 연구)

  • Seo, Jin-Ju;Hong, Dong-Pyo;Kim, Won-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.7-11
    • /
    • 2012
  • For fault detection about the abrasion stage of rotational machineries under the dynamic loading conditions unlike the traditional diagnosis method used in the past decade, the infrared thermographic method with its distinctive advantages in non-contact, non-destructive, and visible aspects is proposed. In this paper, by applying a rotating deep-grooved ball bearing, passive thermographic experiments were conducted as an alternative way to proceeding the traditional fault monitoring on spectrum analyzer. As results, the thermographic experiment was compared with the traditional vibration spectrum analysis to evaluate the efficiency of the proposed method. Based on the results obtained as NDT, the temperature characteristics and abnormal fault detections of the ball bearing according to the abrasion stage were analyzed.

Investigation of Partial Least Squares (PLS) Calibration Performance based on Different Resolutions of Near Infrared Spectra

  • Chung, Hoe-Il;Choi, Seung-Yeol;Choo, Jae-Bum;Lee, Young-Il
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.647-651
    • /
    • 2004
  • Partial Least Squares (PLS) calibration performance has been systematically investigated by changing spectral resolutions of near-infrared (NIR) spectra. For this purpose, synthetic samples simulating naphtha were prepared to examine the calibration performance in complex chemical matrix. These samples were composed of $C_6-C_9$ normal paraffin, iso-paraffin, naphthene, and aromatic hydrocarbons. NIR spectra with four different resolutions of 4, 8, 16, and 32$cm^{-1}$ were collected and then PLS regression was performed. For PLS calibration, five different group compositions (such as total paraffin content) and six different pure components (such as benzene concentration) were selected. The overall results showed that at least 8$cm^{-1}$ resolution was required to resolve the complex chemical matrix such as naphtha. It was found that the influence of resolution on the PLS calibration was varied by the spectral features of a component.

High-resolution Optical and Near-infrared Spectra of 2MASS J06593158-0405277

  • Park, Sunkyung;Lee, Jeong-Eun;Pyo, Tae-Soo;Sung, Hyun-Il;Lee, Sang-Gak;Kang, Wonseok;Yoon, Tae Seog;Park, Won-Kee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.1
    • /
    • pp.54.2-54.2
    • /
    • 2017
  • We present the results of high-resolution optical (R ~ 30,000) and near-infrared (R ~ 45,000) spectroscopic monitoring observations of a new FU Orionis-like young stellar object, 2MASS J06593158-0405277. FU Orionis objects (FUors) are well-studied examples of episodic accretion because of their outburst phenomenon. Recently, 2MASS J06593158-0405277 exhibited an outburst and was identified as an FUor. It provides an important opportunity to investigate the whole FUors phenomenon from its pre-outburst to its post-outburst phase. We observed 2MASS J06593158-0405277 with the Bohyunsan Optical Echelle Spectrograph (BOES) of the Bohyunsan Optical Astronomy Observatory (BOAO) and the Immersion GRating INfrared Spectrograph (IGRINS) of Harlan J. Smith Telescope (HJST) at the McDonald observatory since December 24, 2014. We detected a number of lines and present here our analysis for time variations of those spectral lines.

  • PDF

Defect detection of wall thinning defect in pipes using Lock-in photo-infrared thermography technique (위상잠금 광-적외선 열화상 기술을 이용한 감육결함이 있는 직관시험편의 결함 검출)

  • Kim, Kyoung-Suk;Jang, Su-Ok;Park, Jong-Hyun;Choi, Tae-Ho;Song, Jae-Geun;Jung, Hyun-Chul
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.317-321
    • /
    • 2008
  • Piping in the Nuclear Power plants (NPP) are mostly consisted of carbon steel pipe. The wall thinning defect is mainly occurred by the affect of the flow accelerated corrosion (FAC) of fluid which flows in carbon steel pipes. This type of defect becomes the cause of damage or destruction of piping. Therefore, it is very important to measure defect which is existed not only on the welding partbut also on the whole field of pipe. Over the years, Infrared thermography (IRT) has been used as a non destructive testing methods of the various kinds of materials. This technique has many merits and applied to the industrial field but has limitation to the materials. Therefore, this method was combined with lock-in technique. So IRT detection resolution has been progressively improved using lock-in technique. In this paper, the quantitative analysis results of the location and the size of wall thinning defect that is artificially processed inside the carbon steel pipe by using IRT are obtained.

  • PDF

Korean Secondary Students' Conceptions about Visible light, Ultra Violet and Infrared Ray (가시광선, 자외선과 적외선에 대한 학생들의 개념)

  • Han, Shin;Park, Tae-Yoon;Jeong, Sophia Sun Kyung
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.8 no.1
    • /
    • pp.35-44
    • /
    • 2015
  • The purpose of this paper is to identify the conceptions of middle school and high school students about visible light, Ultra violet(UV) and Infrared ray(IR). We administered questionnaire 40 people of middle school 3rd students and 43 people of high school 2nd students in Gyeonggi-do. Misconceptions about visible light, UV and Ir were observed in many students. The results of study are as follows: Firstly, Many students think that it is possible to see objects without visible light. The explanations given by students for the visiblity of objects in darkness indicates a heavy reliance on personal experiences. Secondly, we have confirmed that high school students well understand the fact that the object reflects the light. However, a significant number of students exhibited an eye-centered perspective of vision. Thirdly, students had a variety of ideas about the meaning of the term UV and IR. Analysis of questionnaire data indicates that many students believe that it is possible to see objects in the presence of UV light alone.

Stimulating Effects of Far-infrared Ray Radiation on the Release of Antioxidative Phenolics in Grape Berries

  • Eom, Seok-Hyun;Park, Hyung-Jae;Seo, Dong-Wan;Kim, Won-Woo;Cho, Dong-Ha
    • Food Science and Biotechnology
    • /
    • v.18 no.2
    • /
    • pp.362-366
    • /
    • 2009
  • This research was conducted to determine the effect of far-infrared ray (FIR) irradiation of grape berries as a potential application for manufacturing grape products with a high amount of antioxidant chemicals. Two grape cultivars, the red grape cv. Campbell Early and the white grape cv. Thompson Seedless, produced increased amounts of crude extracts, in the FIR treatments compared to a non-FIR treatment control with same temperature. However, total phenolic concentrations and antioxidant activity in a 'Campbell Early' increased in the extracts following FIR treatment, whereas those of 'Thompson Seedless' did not increase significantly. High performance liquid chromatography (HPLC) analysis indicated that functional components affecting antioxidant activity were significantly increased in the extract of 'Campbell Early' following FIR treatment. Our results indicate that application of FIR treatment in heat process of grapes increases levels of antioxidative phenolic chemicals and it may help to enhance the availability of antioxidative compounds in various grape food products.

A Study on the Tracking Aging of PMMA using Infrared Radiation Camera (적외선 방사 카메라를 이용한 PMMA 트래킹 열화에 관한 연구)

  • Lee, Hack-Hyun;Lim, Jang-Seob;So, Soon-Youl;Lee, Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.2
    • /
    • pp.188-193
    • /
    • 2007
  • Tracking and erosion of Poly Methyl Methacrylate (PMMA) and the suppression mechanism of alumina trihydrate were investigated in the present study The conventional testing as IEC-60587 is widely used in surface aging measurement of outdoor insulator those testing can carry out very short time for Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outdoor HV system. Therefore it is very useful method compare to previous conventional tracking testing method, But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-Camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this paper, SD occurred from IEC-60587 is measured with the surface temperature of weibull distribution in real time, the degradation grade of SD is analyzed through produced patterns in IEC-60587 using Infrared Radiation(IRR) camera.

Design and analysis of a signal readout integrated circuit for the bolometer type infrared detect sensors (볼로미터형 적외선 센서의 신호처리회로 설계 및 특성)

  • Kim, Jin-Su;Park, Min-Young;Noh, Ho-Seob;Lee, Seoung-Hoon;Lee, Je-Won;Moon, Sung-Wook;Song, Han-Jung
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.475-483
    • /
    • 2007
  • This paper proposes a readout integrated circuit (ROIC) for $32{\times}32$ infrared focal plane array (IRFPA) detector, which consist of reference resistor, detector resistor, reset switch, integrated capacitor and operational amplifier. Proposed ROIC is designed using $0.35{\;}{\mu}m$ 2P-4M (double poly four metal) n-well CMOS process parameters. Low noise folded cascode operational amplifier which is a key element in the ROIC showed 12.8 MHz unity-gain bandwidth and open-gain 89 dB, phase margin $67^{\circ}$, SNR 82 dB. From proposed circuit, we gained output voltage variation ${\Delta}17{\};mV/^{\circ}C$ when the detector resistor varied according to the temperature.

An Experimental Study on the Effects of a Radiation Shield on the Thermal Load of a Cryochamber (복사 차폐막이 극저온 용기의 부하에 미치는 영향에 관한 실험적 연극)

  • Kim, Young-Min;Park, Seong-Je;Kang, Byung-Ha
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.365-370
    • /
    • 2005
  • Infrared (lR) detectors are widely used for such applications as thermoelstic stress analysis, medical diagnostics and temperature measurement. Infrared detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Cryochamber considers the conduction heat transfer through a cold finger, the gases conduction and radiation heat transfer. The thermal loads of an infrared detector Cryochamber with radiation shield are investigated experimentally in present study. Since the effect of radiation heat transfer on thermal loads is significant, radiation shields is installed in the cold finger part to protect heat input through radiation. It is found that the thermal load can be substantially reduced by increasing the number of radiation shield.

  • PDF

Determination of Hydrogen Peroxide Concentration by Portable Near-Infrared (NIR) System (근적외분광분석법을 이용한 과산화수소의 농도 측정)

  • 임현량;우영아;장수현;김경미;김효진
    • YAKHAK HOEJI
    • /
    • v.46 no.5
    • /
    • pp.324-330
    • /
    • 2002
  • This experiment was carried out to determine non-destructively the hydrogen peroxide concentration of 3% antiseptic hydrogen peroxide solutions by portable near-infrared (NIR) system. Hydrogen peroxide standards were prepared ranging from 0 to 25.6 w/w% and the NIR spectra of hydrogen peroxide standard solutions were collected by using a quartz cell in 1 mm pathlength. We found the variation of absorbance band due to OH vibration of hydrogen peroxide depending on the concentration around 1400 nm in the second derivatives spectra. Partial least square regression (PLSR) and multilinear regression (MLR) were explored to develop a calibration model over the spectral range 1100-1720 nm. The model using PLSR was better than that using MLR. The calibration showed good results with a standard error of prediction (SEP) of 0.16%. In order to validate the developed calibration model, routine analyses were performed using commercial antiseptic hydrogen peroxide solutions. The hydrogen peroxide values from the NIR calibration model were compared with the values from a redox titration method. The NIR routine analyses results showed good correlation with those of the redox titration method. This study showed that the rapid and non-destructive determination of hydrogen peroxide in the antiseptic solution was successfully performed by portable NIR system without very harmful solvents.