• Title/Summary/Keyword: Infrared(IR)

Search Result 1,559, Processing Time 0.028 seconds

Combination of Infrared Light Source and Barrier Filter for Suction Bruise Photography (음압에 의해 생성된 멍 촬영을 위한 적외선 광원과 필터 조합에 관한 연구)

  • Kim, Ju-Eun;Kim, Ji-Yeon;Jeon, So-Young;Kim, Eun-A;Yu, Je-Seol
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.11
    • /
    • pp.693-698
    • /
    • 2016
  • Bruise caused by damages through physical compression and suction is one of evidences that can prove abuse or assault. It is essential for taking photography to prove a crime. Some studies about the Infrared (IR) light source have limitations that only one IR light source and one barrier filter were used. To find the best combination of filters and IR light sources, we produced suction bruise artificially and used three IR light sources and five barrier filters. Consequently, we found that the best combination is using a tungsten lamp and Kodak Wratten #18A barrier filter.

Design and Fabrication of Miniaturized Optical Chopper Operated by Electromagnetic Actuation

  • Kim, Ho Won;Min, Seong Ki;Choi, Young Chan;Kong, Seong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.165-169
    • /
    • 2014
  • An existing infrared (IR) analysis system is generally composed of infrared source, IR focusing lenses, IR detector, and optical chopper. An optical chopper is widely used in combination with lock-in amplifier to improve the signal-to-noise ratio by periodically interrupting incident light beam. During recent years, a few researches on miniaturized optical chopper have been reported to apply to micro-scaled optical systems. In this paper, a micro optical chopper operated by electromagnetic actuation is proposed and applied to a miniaturized micro-scaled optical system operating in IR spectral range. Additionally, the fabrication method of the proposed micro chopper is demonstrated. The proposed micro optical chopper is composed of the polydimethylsiloxane (PDMS) membrane, solenoid, and permanent magnet. The permanent magnet is bonded on the PDMS membrane using an ultraviolet-activated adhesive. The operation of the chopper is based on the attractive and repulsive forces between permanent magnet and solenoid induced by an electrical current flowing through the solenoid. The fabricated micro optical chopper could operate up to 200 Hz of frequency. The maximum operating distance of the chopper with 7mm diameter membrane was $750{\mu}m$ at 100 Hz of frequency.

In Orbit Radiometric Calibration Tests of COMS MI Infrared Channels

  • Jin, Kyoung-Wook;Seo, Seok-Bae
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.3
    • /
    • pp.369-377
    • /
    • 2011
  • Since well-calibrated satellite data is critical for their applications, calibration and validation of COMS science data was one of the key activities during the IOT. COMS MI radiometric calibration process was divided into two phases according to the out-gassing of the sensor: calibrations of the visible (VI) and infrared (IR) channels. Different from the VIS calibration, the calibration steps for the IR channels followed additional processes to secure their radiometric performances. Primary calibration steps of the IR were scan mirror emissivity correction, midnight effect compensation, slope averaging and 1/f noise compensation after a nominal calibration. First, the scan mirror emissivity correction was conducted to compensate the variability of the scan mirror emissivity driven by the coating material on the scan mirror. Second, the midnight effect correction was performed to remove unreasonable high spikes of the slope values caused by the excessive radiative sources during the local midnight. After these steps, the residual (difference between the previous slope and the given slope) was filtered by a smoothing routine to eliminate the remnant random noises. The 1/f noise compensation was also carried out to filter out the lower frequency noises caused from the electronics in the Imager. With through calibration processes during the entire IOT period, the calibrated IR data showed excellent performances.

The Design of an Infrared Transcutaneous Control Unit for Totally Implantable Middle Ear System (완전 이식형 인공중이를 위한 체외 및 체내 제어시스템 구현)

  • 정의성;강호경;박일용;윤영호;김민규;송병섭;원철호;조진호
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.5
    • /
    • pp.71-78
    • /
    • 2004
  • An infrared remote control-type transcutaneous control device using a $\mu$-processor is design for the totally implantable middle ear system. An infrared light transmission model for the tissue of skin was introduced and then a radiant intensity and the required current of the infrared light emitting diode(IR LED) driving circuit at transmission part were calculated for the external control device. And the transmission part generates IR signal by the system's own data protocol which prevents interferences from other infrared remote controls of the household appliances. The control part of the implanted device was designed to analyze functions of the received infrared(IR) signal that indicate the power ON/OFF and volume UP/DOWN. After the system is implemented, a data transmission experiments using 4 mm thickness of porcine skin were carried out. From the experiment, it was verified that the infrared control signal was transmitted to receiving module of the implemented system without any error.

Fourier Transform Infrared Spectroscopic Analysis of the Silylated Resist on Silicon Wafers in Semiconductor Lithographic Process (반도체 사진공정에서 실리콘 웨이퍼 위의 Silylated Resist의 Fourier 변환 적외선 분광분석)

  • Kang, Sung Chul;Kim, Su Jong;Son, Min Young;Park, Chun Geun
    • Analytical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.455-464
    • /
    • 1992
  • Using FT-IR, we determined the depth of silylated layers produced from various gas-phase-silylation conditions was proposed by using Fourier Transform Infrared (FT-IR) spectroscopic analysis. The depth of silylated layer was determined from absorbance measurments of the significant peaks (Si-O-ph, Si-C, Si-H) of FT-IR spectra with background spectrum subtraction method. And the results were compared with thickness measurments of SEM. The results were well agree with SEM. It found to be well suited for determining silylation process window.

  • PDF

A Study on Infrared Emissivity Measurement of Material Surface by Reflection Method (반사법에 의한 재료표면의 적외선 방사율 측정에 관한 연구)

  • Kang, Byung-Chul;Kim, Sang-Myoung;Choi, Joung-Yoon;Kim, Gun-Ok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.484-488
    • /
    • 2010
  • Infrared emissivity is one of the most important factors for the temperature measurement by infrared thermography. Although the infrared emissivity of an object can be measured from the ratio of blackbody and the object, at room temperature it is practically difficult to measure the value due to the background effects. Hence, quantitative reflectance of bare steel plate and the surface of coating was measured by FT-IR spectroscopy and emissivity was calculated from this. The emissivity of polished bare steel surface was from 0.06 to 0.10 and the value for the unpolished bare steel can not be achieved because optical characteristics changes of surface roughness induces erroneous results. Emissivity of transparent paint coated steel was from 0.50 to 0.84. Depends on the IR absorption regions, which is a characteristic value of the coating, emissivity changes. This study suggests surface condition of material, thickness, roughness et cetra are important factor for IR optical characteristics. Emissivity measurement by reflection method is useful technique to be applied for metal and it with coating applied on the surface. The range of experimental errors of temperature can be narrowed by the application of infrared thermography from the measured thermal emissivity.

A Study of Test Method for Position Reporting Accuracy of Airborne Camera (항공기 탑재용 카메라 위치출력오차 측정방안 연구)

  • Song, Dae-Buem;Yoon, Yong-Eun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.646-652
    • /
    • 2013
  • PRA(Position Reporting Accuracy) for EO/IR(Electro-Optic/Infrared) airborne camera is an important factor in geo-pointing accuracy. Generally, rate table is used to measure PRA of gimbal actuated camera like EO/IR. However, it is not always possible to fix an EUT(Equipment for Under Test) to rate table due to capacity limit of the table on the size and weight of the object(EUT). Our EO/IR is too big and heavy to emplace on it. Therefore, we propose a new verification method of PRA for airborne camera and assess the validity of our proposition. In this method we use collimator, angle measuring instrument, 6 dof motion simulator, optical surface plate, leveling laser, inclinometer and poster(for alignment).

Study on the MTTF of Multi Wave Lengths IR and NIR LEDs Module (다파장 IR과 NIR 모듈의 평균 수명 예측에 관한 연구)

  • Kim, Dong Pyo;Kim, Kyung Seob
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.1
    • /
    • pp.44-49
    • /
    • 2021
  • Recently, infrared (IR) and near-infrared (NIR) light-emitting diodes (LEDs) were widely used for home medical applications owing to its low output power and wide exposed area for curing. For deep penetration of the light under the skin, multiple LEDs with wavelengths of 700~10,000 nm were located on a flexible printed circuit board. When multiple wavelengths of LEDs were soldered on a circuit board, the lifetime of LED module highly depends on LEDs with a short lifetime. The mean time to failure (MTTF) was able to calculate with the experimental results under high temperature and the Arrhenius model. The results of this study could help companies to approve the warranty of LED modules and its product.

MOSAICFUSION: MERGING MODALITIES WITH PARTIAL DIFFERENTIAL EQUATION AND DISCRETE COSINE TRANSFORMATION

  • GARGI TRIVEDI;RAJESH SANGHAVI
    • Journal of Applied and Pure Mathematics
    • /
    • v.5 no.5_6
    • /
    • pp.389-406
    • /
    • 2023
  • In the pursuit of enhancing image fusion techniques, this research presents a novel approach for fusing multimodal images, specifically infrared (IR) and visible (VIS) images, utilizing a combination of partial differential equations (PDE) and discrete cosine transformation (DCT). The proposed method seeks to leverage the thermal and structural information provided by IR imaging and the fine-grained details offered by VIS imaging create composite images that are superior in quality and informativeness. Through a meticulous fusion process, which involves PDE-guided fusion, DCT component selection, and weighted combination, the methodology aims to strike a balance that optimally preserves essential features and minimizes artifacts. Rigorous evaluations, both objective and subjective, are conducted to validate the effectiveness of the approach. This research contributes to the ongoing advancement of multimodal image fusion, addressing applications in fields like medical imaging, surveillance, and remote sensing, where the marriage of IR and VIS data is of paramount importance.

The Method of Exposure Determination for Digital Infrared Photography in Forensic Field (법과학 분야에서 디지털 적외선 사진을 위한 노출 결정 방법)

  • Kim, Sang-Ki;Kim, Yoo-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.2
    • /
    • pp.181-191
    • /
    • 2014
  • In the past, making IR photography needed somewhat complicated process, so its application fields were limited. However, it has become easy to make IR photography with advanced digital technology, so it is expected that the fields of IR photography and existing limit due to difficult making process will be expanded. Therefore, in this study, it is decided that the need of IR standard chart which allows us to manage exposure and tone of IR photography for scientific purpose will increase. Two methods were used to make IR standard chart. First method is to use aluminum. When aluminum has oxide coating through anodic oxidation, it has high durability, corrosion resistance and heat resistance. Also, IR reflectance of aluminum can be controlled in some degree depending on the thickness of oxide coating. Second method is to use pigments. Yellow 10P150 pigment is used for the brightest patch. This pigment is appropriate in this study due to high heat resistance and IR reflectance. Carbon black is used for the darkest patch. Carbon black absorbs much IR, and its color is not faded by any source of light. IR reflectance is adjusted elaborately by mixing two pigments. Finally, 6 patches are selected with consideration for actual IR reflectance of patches. As a result, IR reflectance of random subjects can be known approximately and IR photographs can have appropriate contrast with the IR standard chart.