• Title/Summary/Keyword: Information Storage Device

Search Result 454, Processing Time 0.031 seconds

Digital Forensic Investigation of HBase (HBase에 대한 디지털 포렌식 조사 기법 연구)

  • Park, Aran;Jeong, Doowon;Lee, Sang Jin
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.2
    • /
    • pp.95-104
    • /
    • 2017
  • As the technology in smart device is growing and Social Network Services(SNS) are becoming more common, the data which is difficult to be processed by existing RDBMS are increasing. As a result of this, NoSQL databases are getting popular as an alternative for processing massive and unstructured data generated in real time. The demand for the technique of digital investigation of NoSQL databases is increasing as the businesses introducing NoSQL database in their system are increasing, although the technique of digital investigation of databases has been researched centered on RDMBS. New techniques of digital forensic investigation are needed as NoSQL Database has no schema to normalize and the storage method differs depending on the type of database and operation environment. Research on document-based database of NoSQL has been done but it is not applicable as itself to other types of NoSQL Database. Therefore, the way of operation and data model, grasp of operation environment, collection and analysis of artifacts and recovery technique of deleted data in HBase which is a NoSQL column-based database are presented in this paper. Also the proposed technique of digital forensic investigation to HBase is verified by an experimental scenario.

Erase Group Flash Translation Layer for Multi Block Erase of Fusion Flash Memory (퓨전 플래시 메모리의 다중 블록 삭제를 위한 Erase Croup Flash Translation Layer)

  • Lee, Dong-Hwan;Cho, Won-Hee;Kim, Deok-Hwan
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.4
    • /
    • pp.21-30
    • /
    • 2009
  • Fusion flash memory such as OneNAND$^{TM}$ is popular as a ubiquitous storage device for embedded systems because it has advantages of NAND and NOR flash memory that it can support large capacity, fast read/write performance and XIP(eXecute-In-Place). Besides, OneNAND$^{TM}$ provides not only advantages of hybrid structure but also multi-block erase function that improves slow erase performance by erasing the multiple blocks simultaneously. But traditional NAND Flash Translation Layer may not fully support it because the garbage collection of traditional FTL only considers a few block as victim block and erases them. In this paper, we propose an Erase Group Flash Translation Layer for improving multi-block erase function. EGFTL uses a superblock scheme for enhancing garbage collection performance and invalid block management to erase multiple blocks simultaneously. Also, it uses clustered hash table to improve the address translation performance of the superblock scheme. The experimental results show that the garbage collection performance of EGFTL is 30% higher than those of traditional FTLs, and the address translation performance of EGFTL is 5% higher than that of Superblock scheme.

Design of 3-bit Arbitrary Logic Circuit based on Single Layer Magnetic-Tunnel-Junction Elements (단층 입력 구조의 Magnetic-Tunnel-Junction 소자를 이용한 임의의 3비트 논리회로 구현을 위한 자기논리 회로 설계)

  • Lee, Hyun-Joo;Kim, So-Jeong;Lee, Seung-Yeon;Lee, Seung-Jun;Shin, Hyung-Soon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.12
    • /
    • pp.1-7
    • /
    • 2008
  • Magnetic Tunneling Junction (MTJ) has been used as a nonvolatile universal storage element mainly in memory technology. However, according to several recent studies, magneto-logic using MTJ elements show much potential in substitution for the transistor-based logic device. Magneto-logic based on MTJ can maintain the data during the power-off mode, since an MTJ element can store the result data in itself. Moreover, just by changing input signals, the full logic functions can be realized. Because of its programmability, it can embody the reconfigurable magneto-logic circuit in the rigid physical architecture. In this paper, we propose a novel 3-bit arbitrary magneto-logic circuit beyond the simple combinational logic or the short sequential one. We design the 3-bit magneto-logic which has the most complexity using MTJ elements and verify its functionality. The simulation results are presented with the HSPICE macro-model of MTJ that we have developed in our previous work. This novel magneto-logic based on MTJ can realize the most complex logic function. What is more, 3-bit arbitrary logic operations can be implemented by changing gate signals of the current drivel circuit.

Structure and Magnetic Properties of Ho and Ni Co-doped BiFeO3 Ceramics

  • Hwang, J.S.;Yoo, Y.J.;Park, J.S.;Kang, J.H.;Lee, K.H.;Lee, B.W.;Kim, K.W.;Lee, Y.P.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.183-183
    • /
    • 2014
  • Recently, multiferroic materials gain much attention due to their fascinating fundamental physical properties. These materials offer wide range of potential applications such as data storage, spintronic devices and sensors, where both electronic and magnetic polarizations can be coupled. Among single-phase multiferroic materials, $BiFeO_3$ is typical because of the room-temperature magnetoelectric coupling in view of long-range magnetic- and ferroelectric-ordering temperatures. However, $BiFeO_3$ is well known to have large leakage current and small spontaneous polarization due to the existence of oxygen vacancies and other defects. Furthermore the magnetic moment of pure $BiFeO_3$ is very weak owing to its antiferromagnetic nature. Recently, various attempts have been performed to improve the multiferroic properties of $BiFeO_3$ through the co-doping at the A and the B sites, by making use of the fact that the intrinsic polarization and magnetization are associated with the lone pair of $Bi^{3+}$ ions at the A sites and the partially-filled 3d orbitals of $Fe^{3+}$ ions at the B sites, respectively. In this study, $BiFeO_3$, $Bi_{0.9}Ho_{0.1}FeO_3$, $BiFe_{0.97}Ni_{0.03}O_3$ and $Bi_{0.9}Ho_{0.1}Fe_{0.97}Ni_{0.03}O_3$ bulk compounds were prepared by solid-state reaction and rapid sintering. High-purity $Bi_2O_3$, $Ho_2O_3$, $Fe_2O_3$ and $NiO_2$ powders with the stoichiometric proportions were mixed, and calcined at $500^{\circ}C$ for 24 h to produce the samples. The samples were immediately put into an oven, which was heated up to $800^{\circ}C$ and sintered in air for 1 h. The crystalline structure of samples was investigated at room temperature by using a Rigaku Miniflex powder diffractometer. The field-dependent and temperature-dependent magnetization measurements were performed with a vibrating-sample magnetometer and superconducting quantum-interference device.

  • PDF

Log-Structured B-Tree for NAND Flash Memory (NAND 플래시 메모리를 위한 로그 기반의 B-트리)

  • Kim, Bo-Kyeong;Joo, Young-Do;Lee, Dong-Ho
    • The KIPS Transactions:PartD
    • /
    • v.15D no.6
    • /
    • pp.755-766
    • /
    • 2008
  • Recently, NAND flash memory is becoming into the spotlight as a next-generation storage device because of its small size, fast speed, low power consumption, and etc. compared to the hard disk. However, due to the distinct characteristics such as erase-before-write architecture, asymmetric operation speed and unit, disk-based systems and applications may result in severe performance degradation when directly implementing them on NAND flash memory. Especially when a B-tree is implemented on NAND flash memory, intensive overwrite operations may be caused by record inserting, deleting, and reorganizing. These may result in severe performance degradation. Although ${\mu}$-tree has been proposed in order to overcome this problem, it suffers from frequent node split and rapid increment of its height. In this paper, we propose Log-Structured B-Tree(LSB-Tree) where the corresponding log node to a leaf node is allocated for update operation and then the modified data in the log node is stored at only one write operation. LSB-tree reduces additional write operations by deferring the change of parent nodes. Also, it reduces the write operation by switching a log node to a new leaf node when inserting the data sequentially by the key order. Finally, we show that LSB-tree yields a better performance on NAND flash memory by comparing it to ${\mu}$-tree through various experiments.

Design of the Flexible Buffer Node Technique to Adjust the Insertion/Search Cost in Historical Index (과거 위치 색인에서 입력/검색 비용 조정을 위한 가변 버퍼 노드 기법 설계)

  • Jung, Young-Jin;Ahn, Bu-Young;Lee, Yang-Koo;Lee, Dong-Gyu;Ryu, Keun-Ho
    • The KIPS Transactions:PartD
    • /
    • v.18D no.4
    • /
    • pp.225-236
    • /
    • 2011
  • Various applications of LBS (Location Based Services) are being developed to provide the customized service depending on user's location with progress of wireless communication technology and miniaturization of personalized device. To effectively process an amount of vehicles' location data, LBS requires the techniques such as vehicle observation, data communication, data insertion and search, and user query processing. In this paper, we propose the historical location index, GIP-FB (Group Insertion tree with Flexible Buffer Node) and the flexible buffer node technique to adjust the cost of data insertion and search. the designed GIP+ based index employs the buffer node and the projection storage to cut the cost of insertion and search. Besides, it adjusts the cost of insertion and search by changing the number of line segments of the buffer node with user defined time interval. In the experiment, the buffer node size influences the performance of GIP-FB by changing the number of non-leaf node of the index. the proposed flexible buffer node is used to adjust the performance of the historical location index depending on the applications of LBS.

Efficient Stack Smashing Attack Detection Method Using DSLR (DSLR을 이용한 효율적인 스택스매싱 공격탐지 방법)

  • Do Yeong Hwang;Dong-Young Yoo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.9
    • /
    • pp.283-290
    • /
    • 2023
  • With the recent steady development of IoT technology, it is widely used in medical systems and smart TV watches. 66% of software development is developed through language C, which is vulnerable to memory attacks, and acts as a threat to IoT devices using language C. A stack-smashing overflow attack inserts a value larger than the user-defined buffer size, overwriting the area where the return address is stored, preventing the program from operating normally. IoT devices with low memory capacity are vulnerable to stack smashing overflow attacks. In addition, if the existing vaccine program is applied as it is, the IoT device will not operate normally. In order to defend against stack smashing overflow attacks on IoT devices, we used canaries among several detection methods to set conditions with random values, checksum, and DSLR (random storage locations), respectively. Two canaries were placed within the buffer, one in front of the return address, which is the end of the buffer, and the other was stored in a random location in-buffer. This makes it difficult for an attacker to guess the location of a canary stored in a fixed location by storing the canary in a random location because it is easy for an attacker to predict its location. After executing the detection program, after a stack smashing overflow attack occurs, if each condition is satisfied, the program is terminated. The set conditions were combined to create a number of eight cases and tested. Through this, it was found that it is more efficient to use a detection method using DSLR than a detection method using multiple conditions for IoT devices.

A Design of Authentication Mechanism for Secure Communication in Smart Factory Environments (스마트 팩토리 환경에서 안전한 통신을 위한 인증 메커니즘 설계)

  • Joong-oh Park
    • Journal of Industrial Convergence
    • /
    • v.22 no.4
    • /
    • pp.1-9
    • /
    • 2024
  • Smart factories represent production facilities where cutting-edge information and communication technologies are fused with manufacturing processes, reflecting rapid advancements and changes in the global manufacturing sector. They capitalize on the integration of robotics and automation, the Internet of Things (IoT), and the convergence of artificial intelligence technologies to maximize production efficiency in various manufacturing environments. However, the smart factory environment is prone to security threats and vulnerabilities due to various attack techniques. When security threats occur in smart factories, they can lead to financial losses, damage to corporate reputation, and even human casualties, necessitating an appropriate security response. Therefore, this paper proposes a security authentication mechanism for safe communication in the smart factory environment. The components of the proposed authentication mechanism include smart devices, an internal operation management system, an authentication system, and a cloud storage server. The smart device registration process, authentication procedure, and the detailed design of anomaly detection and update procedures were meticulously developed. And the safety of the proposed authentication mechanism was analyzed, and through performance analysis with existing authentication mechanisms, we confirmed an efficiency improvement of approximately 8%. Additionally, this paper presents directions for future research on lightweight protocols and security strategies for the application of the proposed technology, aiming to enhance security.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 - (공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF