• Title/Summary/Keyword: Information Opacity

Search Result 59, Processing Time 0.024 seconds

Evaluation on usefulness of three dimensional reconstructive computed tomography images after pedicle screws fixation (척추경 나사못 고정술 시행 후 3차원 재구성CT영상의 유용성 평가)

  • Kim, Hyeon-Ju;Jang, Hyun-Chul;Cho, Jae-Hwan
    • Journal of Digital Contents Society
    • /
    • v.11 no.4
    • /
    • pp.553-559
    • /
    • 2010
  • By applying the various reformation techniques by using a circle raw data of after computed tomography image in the patient enforcing the spine screw fixation, this research tried to look into the various information including the exact location of the position of the screw spike and accuracy of an operation. In a clinical, by applying the or multi planar reformatting(MPR), that is the re-composition technique used mainly, maximum intensity projection (MIP), and volume rendering technique(VRT) and transformation removal from a register modifying VRT, video data were compared and were analyzed by the quantitative method and qualitative method. It is judged as the transformation volume rendering technique of the re-composition technique which is most useful in minimizing the artifact shadow by the exact location of the position of a screw and metal among the analysis and evaluation result computed tomography image reformation technique of the reformation image after the spine screw fixation.

RBM-based distributed representation of language (RBM을 이용한 언어의 분산 표상화)

  • You, Heejo;Nam, Kichun;Nam, Hosung
    • Korean Journal of Cognitive Science
    • /
    • v.28 no.2
    • /
    • pp.111-131
    • /
    • 2017
  • The connectionist model is one approach to studying language processing from a computational perspective. And building a representation in the connectionist model study is just as important as making the structure of the model in that it determines the level of learning and performance of the model. The connectionist model has been constructed in two different ways: localist representation and distributed representation. However, the localist representation used in the previous studies had limitations in that the unit of the output layer having a rare target activation value is inactivated, and the past distributed representation has the limitation of difficulty in confirming the result by the opacity of the displayed information. This has been a limitation of the overall connection model study. In this paper, we present a new method to induce distributed representation with local representation using abstraction of information, which is a feature of restricted Boltzmann machine, with respect to the limitation of such representation of the past. As a result, our proposed method effectively solves the problem of conventional representation by using the method of information compression and inverse transformation of distributed representation into local representation.

Renal Cell Carcinoma in a Pekingese Dog (페키니즈견에서 신장세포암종)

  • Lee Ki-chang;Jung Joo-hyun;Byeon Ye-eun;Oh Sun-kyung;Seo Eun-jung;Song Kyung-jin;Kweon Oh-kyeong;Yoon Jung-hee;Choi Min-cheol
    • Journal of Veterinary Clinics
    • /
    • v.22 no.2
    • /
    • pp.148-152
    • /
    • 2005
  • An intact female, 5-year-old, Pekingese, weighing 3.5kg with a history of a palpated abdominal mass was referred to Veterinary Medical Teaching Hospital, Seoul National University. In laboratory examination, there were no remarkable abnormalities. Radiographic findings included a left mid-abdominal mass with ill-defined margin, serosal detail loss of peritoneal space, non-uniform opacity of retroperitoneal space, and a radiopaque cystic calculus. On abdominal ultrasonography, a heterogeneous parenchymal mass with irregular contour in the left renal region was found. Computed tomographic findings showed a tumor embolus within the caudal vena cava and an invasion into mesentery, small bowel loops, spleen and pancreas around the large left renal mass. Unilateral nephroureterectomy was performed. Histopathologic examination of the resected mass confirmed the diagnosis of renal cell carcinoma. The dog died one day after surgery. Although ultrasonography could give diagnostic information about mass characteristics, computed tomography (CT) can provide key imaging features of mass characteristics.

Risk Factors Associated with Cataract by in Middle-aged and Older Korean Adults (한국인의 장년층과 노년층의 백내장 위험 요인)

  • Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.449-455
    • /
    • 2012
  • Purpose: This study was found the risk factors of cataract by gender in elder and older Korean adults. Methods: We investigated the data for 5,024 (men 2,163 people, women 2,861 people) people, aged 40-95 years, from the Korean National Health and Nutrition Examination Survey. We divided into two groups (group 1: 40-64 years, group 2: 65-94 years). We divided into two groups (group 1: 40-64 years, group 2: 65-94 years). Cataract was decided in case of at least one eye with lens opacity. We presented significant odds ratio (OR) increase of cataract according to the obesity and socioeconomic information including house income and education level after adjusting for diabetes, hypertension, high triglyceride, outside active, smoking and drinking habits in two groups with distinction of sex. Results: House income (or education) was strongly related to the prevalence of agerelated cataract in all groups. In models adjusting for all other related factors, cataract patients with lower income and education had a higher prevalence of cataract (group1: OR, 1.84[1.17-2.91], OR, 3.00[1.90-4.74], group 2: OR, 3.47[2.53-4.74], OR, 7.44[5.41-10.23] for men. In comparison, for women, cataract patients with lower income, lower education and obesity had a higher prevalence of cataract (group1: OR, 1.72[1.14-2.60], OR, 4.48[2.72-7.38], OR, 1.40[1.10-1.82], group 2: OR, 2.32[1.70-3.16], OR, 29.99[20.31-44.28], OR, 1.27[1.04-1.54]). Conclusions: Factors of low socioeconomic status were associated with age-related cataract in Korean. Obesity-cataract association was stronger in women.

A Quality Comparison of Traditional Korean Papers: Mixtures of Bast-Fiber with Straw pulp(Rice straw paper) in Different Composition Ratio (고정(藁精) 혼합비율에 따른 한지의 물성 비교)

  • Jung, Sun-Young
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.39 no.1 s.119
    • /
    • pp.48-55
    • /
    • 2007
  • The aim of this article is to review the general property of the famous traditional Korean paper, "rice straw paper"(Bast-Fiber mixed with straw pulp), and to compare the paper qualities varying with the composition ratio of straw pulp, in order to revive the traditional paper in modem Korea. The experiment was carried out by making first the two different mixture papers, i. e., one is the paper of 50% bast fiber mixed with 50% straw pulp, and the other is the paper of 75% bast fiber with 25% oats straw pulp, and finally the 100% bast fiber paper was made for the purpose of comparison. The qualitative properties of these three kinds of paper with the different mixing ratio of the straw pulp were evaluated, and the findings of the experiment can be summarized as follow: 1. As to the quality aspects of the paper strength like tensile strength, breaking length, elongation, and tear strength, the test proved the 100% bast fiber paper as best, and the 50% mixed paper as the next good one. 2. In aspect of the printing adaptability such as density, opacity, brightness, whiteness, lab colors, air permeability, and roughness, the 50% mixed paper proved to be the best, due to the short cells in the straw pulp. 3. As to the air permeability, the larger ratio of straw pulp was found to be the lesser, and 75% bast fiber with 25% straw pulp mixture paper and the 100% bast fiber one were found 1/5 degree efficient. 4. In terms of the water absorption degree, 100% bast fiber paper was the fastest, but in case of mixture paper, 50% mixed one was a little faster up to the point of 1cm, while the two kinds of mixed ones appear to be almost similar to each other beyond the point. 5. The straw pulp mixed paper, especially the 50% mixed one was evaluated as the highest by the calligraphers who had experienced using the papers in terms of movement and feeling of the caligraphy and painting. In addition, although the 25% mixed paper is judged to be good for book printing because of the strength, the 50% mixed paper can be thought to be more desirable for painting and calligraphy. In conclusion, we will be able to make the quality paper with durability, by mixing the straw pulp with the bast fiber in proper ratio, following the tradition of Korean paper making.

A case of distichiasis treatment using electroepilation in a dog (개에서 전기제모술을 이용한 첩모중생의 치료 1례)

  • Myeong-Gon, Kang;Dong-Hyun, Han;Sei-Myoung, Han;Eun-Gyeom, Jung;Gyeong-Min, Kim;Shin-Ho, Lee;Yoon-Joo, Shin;Ju-Bin, Kang;Dong-Bin, Lee;Phil-Ok, Koh;Jae-Hyeon, Cho;Chung-Kil, Won;Chung-Hui, Kim
    • Korean Journal of Veterinary Service
    • /
    • v.45 no.4
    • /
    • pp.325-330
    • /
    • 2022
  • Distichiasis is one of the diseases commonly encountered in companion animals, and these abnormal eyelashes cause corneal ulcers, continuous eye irritation, eye pain, glare, epiphora, foreign body sensation and can cause corneal opacity and vision loss in severe cases. In this study, an eyelash epilation needle for animals was developed and applied to a real case, and the results were observed. In a case of corneal ulcer caused by distichiasis of a 2-year-old Shih Tzu, a high-frequency surgical instrument for animals was converted into an electric epilation needle to attempt a procedure to destroy the eyelash hair follicles on the upper eyelid. A epilation needle was developed to have a diameter of 0.1 mm and a length of 4 mm at the end of the handle of DOCTANZ 400, an electrosurgical instrument for animals only. In the procedure, 2~3 mm of an epilation needle was inserted into the hair follicle, and 1 watt of electric power was applied to the hair follicle for about 5 sec. to carry out electrolysis until white bubbles were generated around the meibomian glands thereby destroying the hair follicle. As a result, no eyelashes grew any longer in the treated area indicating that the treatment was successful. It is hoped that the method developed in this study will be applied so that it will be widely used as a treatment method for distichiasis in companion animals that can be frequently seen hereafter.

Primary Invasive Mucinous Adenocarcinoma of the Lung: Prognostic Value of CT Imaging Features Combined with Clinical Factors

  • Tingting Wang;Yang Yang;Xinyue Liu;Jiajun Deng;Junqi Wu;Likun Hou;Chunyan Wu;Yunlang She;Xiwen Sun;Dong Xie;Chang Chen
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.652-662
    • /
    • 2021
  • Objective: To investigate the association between CT imaging features and survival outcomes in patients with primary invasive mucinous adenocarcinoma (IMA). Materials and Methods: Preoperative CT image findings were consecutively evaluated in 317 patients with resected IMA from January 2011 to December 2015. The association between CT features and long-term survival were assessed by univariate analysis. The independent prognostic factors were identified by the multivariate Cox regression analyses. The survival comparison of IMA patients was investigated using the Kaplan-Meier method and propensity scores. Furthermore, the prognostic impact of CT features was assessed based on different imaging subtypes, and the results were adjusted using the Bonferroni method. Results: The median follow-up time was 52.8 months; the 5-year disease-free survival (DFS) and overall survival rates of resected IMAs were 68.5% and 77.6%, respectively. The univariate analyses of all IMA patients demonstrated that 15 CT imaging features, in addition to the clinicopathologic characteristics, significantly correlated with the recurrence or death of IMA patients. The multivariable analysis revealed that five of them, including imaging subtype (p = 0.002), spiculation (p < 0.001), tumor density (p = 0.008), air bronchogram (p < 0.001), emphysema (p < 0.001), and location (p = 0.029) were independent prognostic factors. The subgroup analysis demonstrated that pneumonic-type IMA had a significantly worse prognosis than solitary-type IMA. Moreover, for solitary-type IMAs, the most independent CT imaging biomarkers were air bronchogram and emphysema with an adjusted p value less than 0.05; for pneumonic-type IMA, the tumors with mixed consolidation and ground-glass opacity were associated with a longer DFS (adjusted p = 0.012). Conclusion: CT imaging features characteristic of IMA may provide prognostic information and individual risk assessment in addition to the recognized clinical predictors.

Modern Paper Quality Control

  • Olavi Komppa
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.06a
    • /
    • pp.16-23
    • /
    • 2000
  • The increasing functional needs of top-quality printing papers and packaging paperboards, and especially the rapid developments in electronic printing processes and various computer printers during past few years, set new targets and requirements for modern paper quality. Most of these paper grades of today have relatively high filler content, are moderately or heavily calendered , and have many coating layers for the best appearance and performance. In practice, this means that many of the traditional quality assurance methods, mostly designed to measure papers made of pure. native pulp only, can not reliably (or at all) be used to analyze or rank the quality of modern papers. Hence, introduction of new measurement techniques is necessary to assure and further develop the paper quality today and in the future. Paper formation , i.e. small scale (millimeter scale) variation of basis weight, is the most important quality parameter of paper-making due to its influence on practically all the other quality properties of paper. The ideal paper would be completely uniform so that the basis weight of each small point (area) measured would be the same. In practice, of course, this is not possible because there always exists relatively large local variations in paper. However, these small scale basis weight variations are the major reason for many other quality problems, including calender blacking uneven coating result, uneven printing result, etc. The traditionally used visual inspection or optical measurement of the paper does not give us a reliable understanding of the material variations in the paper because in modern paper making process the optical behavior of paper is strongly affected by using e.g. fillers, dye or coating colors. Futhermore, the opacity (optical density) of the paper is changed at different process stages like wet pressing and calendering. The greatest advantage of using beta transmission method to measure paper formation is that it can be very reliably calibrated to measure true basis weight variation of all kinds of paper and board, independently on sample basis weight or paper grade. This gives us the possibility to measure, compare and judge papers made of different raw materials, different color, or even to measure heavily calendered, coated or printed papers. Scientific research of paper physics has shown that the orientation of the top layer (paper surface) fibers of the sheet paly the key role in paper curling and cockling , causing the typical practical problems (paper jam) with modern fax and copy machines, electronic printing , etc. On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard . Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and coclking tendency, and provides the necessary information to finetune, the manufacturing process for optimum quality. many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, bing beyond the measurement range of the traditional instruments or resulting invonveniently long measuring time per sample . The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, nonleaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layer of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow in well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings ! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly ass planned (having even small measurement error or malfunction ), the process control will set the machine to operate away from the optimum , resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.

COLOR DIFFERENCES BETWEEN RESIN COMPOSITES BEFORE- AND AFTER-POLYMERIZATION, AND SHADE GUIDES (복합레진의 광중합 전·후와 shade guide의 색차 비교)

  • Chon, Yi-Ju;Cho, Sung-Shik;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.299-309
    • /
    • 1999
  • The composite resin, due to its esthetic qualities, is considered the material of choice for restoration of anterior teeth. With respect to shade control, the direct-placement resin composites offer some distinct advantages over indirect restorative procedures. Visible-light-cured (VLC) composites allow dentists to match existing tooth shades or to create new shades and to evaluate them immediately at the time of restoration placement. Optimal intraoral color control can be achieved if optical changes occurring during application are minimized. An ideal VLC composite, then, would be one which is optically stable throughout the polymerization process. The shade guides of the resin composites are generally made of plastic, rather than the actual composite material, and do not accurately depict the true shade, translucency, or opacity of the resin composite after polymerization. So the numerous problems associated with these shade guides lead to varied and sometimes unpredictable results. The aim of this study was to assess the color changes of current resin composite restorative materials which occur as a result of the polymerization process and to compare the color differences between the shade guides provided with the products and the actual resin composites before- and after-polymerization. The results obtained from this investigation should provide the clinician with information which may aid in improved color match of esthetic restoration. Five light activated, resin-based materials (${\AE}$litefil, Amelogen Universal, Spectrum TPH VeridonFil-Photo, and Z100) and shade guides were used in this study. Three specimens of each material and shade combination were made. Each material was condensed inside a 1.5mm thick metal mold with 10mm diameter and pressed between glass plates. Each material was measured immediately before polymerization, and polymerized with Curing Light XL 3000 (3M Dental products, USA) visible light-activation unit for 60 seconds at each side. The specimens were then polished sequentially on wet sandpaper. Shade guides were ground with polishing stones and rubber points (Shofu) to a thickness of approximately 1.5mm. Color characteristics were performed with a spectrophotometer (CM-3500d, Minolta Co., LTD). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$ and $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E{^*}ab$) of resin composites before the polymerization process and shade guides using the post-polishing color of the composite as a control, CIE standard D65 was used as the light source. The results were as follows. 1. Each of the resin composites evaluated showed significant color changes during light-curing process. All the resin composites evaluated except all the tested shades of 2100 showed unacceptable level of color changes (${\Delta}E{^*}ab$ greater than 3.3) between pre-polymerization and post-polishing state. 2. Color differences between most of the resin composites tested and their corresponding shade guides were acceptable but those between C2 shade of ${\AE}$litefil and IE shade of Amelogen Universal and their respective shade guides exceeded what is acceptable. 3. Comparison of the mean ${\Delta}E{^*}ab$ values of materials revealed that Z100 showed the least overall color change between pre-polymerization and post-polishing state followed by ${\AE}$litefil, VeridonFil-Photo, Spectrum TPH, and Amelogen Universal in the order of increasing change and Amelogen Universal. Spectrum TPH, 2100, VeridonFil-Photo and ${\AE}$litefil for the color differences between actual resin and shade guide. 4. In the clinical environment, the shade guide is the better choice than the shade of the actual resin before polymerization when matching colors. But, it is recommended that custom shade guides be made from resin material itself for better color matching.

  • PDF