• Title/Summary/Keyword: Information Modalities

Search Result 181, Processing Time 0.041 seconds

Time is Gut. Approaching Intestinal Leiomyositis: Case Presentation and Literature Review

  • Michail Aftzoglou;Christina Heinrich;Till Sebastian Clauditz;Thomas Menter;Deborah Dorth;Konrad Reinshagen;Ingo Konigs
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.27 no.4
    • /
    • pp.197-205
    • /
    • 2024
  • T-lymphocytic intestinal leiomyositis is a rare cause of "pediatric intestinal pseudo-obstructions." Diagnosis may be difficult and requires full-thickness bowel biopsies during laparotomy or laparoscopy with possible enterostomy. Currently, immunosuppressive therapy is the only available treatment. A delay in diagnosis and therapy may negatively affect the prognosis because of ongoing fibrotic alterations; therefore, early diagnosis and consequent treatment are crucial. This review summarizes the available information on the nosology, diagnostic steps, and treatment modalities. Here, we report the youngest case of enteric leiomyositis reported in the last two decades and analyze its management by reviewing previous cases.

Outcomes of Chronic Peritoneal Dialysis by Various Modalities in Korean Children - A Single Center Study (소아 환자에서 다양한 복막투석 방법간의 결과 비교-단일기관 연구)

  • Lee, Sung-Ha;Baek, Jae-Suk;Lee, Hyun-Kyung;Han, Kyoung-Hee;Choi, Hyun-Jin;Lee, Bum-Hee;Cho, Hee-Yeon;Cheong, Hae-Il;Choi, Yong;Ha, Il-Soo
    • Childhood Kidney Diseases
    • /
    • v.11 no.2
    • /
    • pp.255-263
    • /
    • 2007
  • Purpose : A single center cross sectional retrospective study was performed to compare the outcomes of different peritoneal dialysis(PD) modalities in Korean children. Methods : Among children dialyzed with PD between the year 2004 and 2007, 35 children had reliable data on PD adequacy after 3 to 15 months of dialysis. Subjects were grouped by their modalities; 17, 13 and 5 children were on continuous ambulatory PD(CAPD), continuous cyclic PD(CCPD) and nightly intermittent PD(NIPD), respectively. Body weight and height, number of patients taking anti-hypertensives and laboratory data including biochemical and hemoglobin levels were compared. Dialysis adequacy including weekly Kt/Vurea, creatinine clearance (Ccr) and daily water removal were also compared. Patients were sub-grouped by their peritoneal permeability characteristics. Results : The percentage of patients taking anti-hypertensives, monthly change in Z-scores of body weight and height and laboratory data did not differ among the groups. Patients on CAPD and CCPD showed similar dialysis adequacies. Weekly dialytic Ccr was significantly lower in the NIPD group compared to the others. But total Ccr was not different when residual renal function was added. Weekly dialytic Ccr by CAPD was significantly higher than that of CCPD in low and low-average transporters. Conclusion : We propose that modality can be selected flexibly according to the patients' preferences. And peritoneal permeability characteristics provide valuable information for adjusting PD prescriptions in ultrafiltration failure or in inadequate dialysis. Further study of other clinical performance measures should be performed to clarify the comparable outcomes in different PD modalities.

  • PDF

An On-Line Signature Verification Algorithm Based On Neural Network (신경망 기반의 온라인 서명 검증 알고리듬)

  • Lee, Wan-Suck;Kim, Seong-Hoon
    • Journal of Intelligence and Information Systems
    • /
    • v.7 no.2
    • /
    • pp.143-151
    • /
    • 2001
  • This paper investigates the development of a neural network based system for automated signature authentication that relies on an autoregressive characterization for the segments of a signature. The primary contributions of this work are tow-fold: a) the development of the neural network architecture and the modalities of training it, b) adaptation of the dynamic time warping algorithm to fomulate a new method for enabling consistent segmentation of multiple signatures from the same writer. The performance of the signature verification system has been tested using a sizable database that includes a comprehensive set of simulated and realistic forgeries. False Acceptance and False Rejection error rates of 0.78% and 1.6% respectively were obtained in tests conducted using 1920 skilled forgeries.

  • PDF

Registration of 3D CT Data to 2D Endoscopic Image using a Gradient Mutual Information based Viewpoint Matching for Image-Guided Medialization Laryngoplasty

  • Yim, Yeny;Wakid, Mike;Kirmizibayrak, Can;Bielamowicz, Steven;Hahn, James
    • Journal of Computing Science and Engineering
    • /
    • v.4 no.4
    • /
    • pp.368-387
    • /
    • 2010
  • We propose a novel method for the registration of 3D CT scans to 2D endoscopic images during the image-guided medialization laryngoplasty. This study aims to allow the surgeon to find the precise configuration of the implant and place it into the desired location by employing accurate registration methods of the 3D CT data to intra-operative patient and interactive visualization tools for the registered images. In this study, the proposed registration methods enable the surgeon to compare the outcome of the procedure to the pre-planned shape by matching the vocal folds in the CT rendered images to the endoscopic images. The 3D image fusion provides an interactive and intuitive guidance for surgeon by visualizing a combined and correlated relationship of the multiple imaging modalities. The 3D Magic Lens helps to effectively visualize laryngeal anatomical structures by applying different transparencies and transfer functions to the region of interest. The preliminary results of the study demonstrated that the proposed method can be readily extended for image-guided surgery of real patients.

Clinical Application of $^{18}F-FDG$ PET in Ovarian Cancer (난소암에서 $^{18}F-FDG$ PET의 임상 이용)

  • Oh, So-Won;Kim, Seok-Ki
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.91-100
    • /
    • 2008
  • Ovarian cancer is often fatal since it is difficult to diagnose early and recurrence is quite frequent despite successful implementation of cytoreductive surgery and chemotherapy, thus exact diagnosis and early detection of recurrence are crucial to patient management. For pre-treatment staging, FDG PET could be helpful in a limited patient group possessing high risks of ovarian cancer. Besides, FDG PET could be recommended to patients with a high suspicion of recurrence i.e. rise of CA-125, especially in cases of conventional diagnostic imaging modalities presenting no evidence of disease because FDG PET provides critical information for treatment planning such as recurrence site or pattern. In order to expand the use of FDG PET to general population at staging or routine surveillance of ovarian cancer, more investigation is needed. The usefulness of FDG PET in evaluating treatment response and prognosis of ovarian cancer has not yet been determined, but it has been reported that FDG PET could evaluate treatment response early and show a close relationship with overall survival. PET/CT has been actively adopted in management of ovarian cancer. Not only in detecting tumor recurrence and evaluating treatment response but also in pre-treatment staging, FDG PET/CT is expected to playa role due to available anatomical information.

PHealth Service Deployment Methodology: A Case Study

  • Paggetti, Cristiano;Rugnone, Alberto;Tamburini, Elena;Nugent, Chris
    • Journal of Computing Science and Engineering
    • /
    • v.6 no.1
    • /
    • pp.60-66
    • /
    • 2012
  • It has been proved that information and communication technology (ICT) solutions for personalized health (PHealth) and ambient assisted living (AAL) can support people in their daily life activities. Several solutions have been demonstrated to empower different levels of services through seamless data acquisition and specific users' interaction modalities. Usually services usability and accessibility are handled in the design process and are validated with small users' groups. Moreover, while service design and systems development have been extensively described in literature, service deployment methodologies are not properly addressed and documented. Proper reference guidelines are also missing. The most common methodologies like unified process (UP) or ICONX can cover only the design and the development of PHealth services without a clear description on the following phases such as deployment, service provision and maintenance. These phases present several risks to be taken into account right from the beginning of the implementation of PHealth or AAL services. This paper focuses on the description of a structured methodology to deploy PHealth services and how this process can be supported by integrated software routines and adapting the UP framework in particular the "Transition phase."

The CDA-based System Design and Implementation for the Exchange of ECG Reports Between Heterogeneous Systems (이기종간 심전도 판독지 교환을 위한 CDA에 기반한 시스템 설계 및 구현)

  • 전명주;이창건;최진욱;김인영;김선일
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.415-419
    • /
    • 2004
  • As the medical environment field has been facilitated by the rapid development of the information technologies and ubiquitous healthcare service based on network, the exchange of medical information between hospitals become more and more important. However, although most electrocardiograph vendors have provided digital modalities and their ECG data management systems, these were proprietary and not compatible with each other due to multiplicity of vendor specific formats and lack of open ECG data standards. Therefore, we aim to design and develop the ECG management system for archiving, saving, searching, viewing and transferring ECG data and the diagnostic reports. And the system is based on Clinical Document Architecture (CDA) developed by HL7 and DICOM Waveform Standard for the exchange of the structured diagnostic reports and the transfer of ECG data.

Electronic Pen-based Unilateral Visual Neglect Assessment and Rehabilitation System (전자펜 기반 편측시각무시(UVN) 환자 검사 및 재활치료 시스템)

  • Kim, Joonkyo;Jee, Haemi;Park, Jaehyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.6
    • /
    • pp.647-650
    • /
    • 2014
  • Assessment and rehabilitation of patients with unilateral visual neglect has been one of the fields that require assistive technology. Paper-and-pencil tests, including the LBT (Line Bisection Test), have been one of the most commonly used visual neglect assessment methods used in a clinical setting. The key motivation of this study was to establish a computer-based real-time assessment system for the hemi-neglect patients without altering the conventional paper-and-pencil based user tools. A digital penbased assessment and rehabilitation system, the ePen System, could eliminate the manual assessment time while maintaining measurement accuracy. As a result, the proposed system may assist rehabilitation specialists to assess and diagnose patients with unilateral visual neglect. This system can be applied to a range assessment and rehabilitation modalities based on a pen and paper. It can also be applied to various patients such as those with Parkinson's disease, stroke sufferers, or those who have experienced different forms of brain lesions.

Clinical Application of Cardiac Hybrid Imaging in Coronary Artery Disease (관상동맥질환에서 심장 하이브리드 영상의 임상적 이용)

  • Gho, Ihn-Ho;Kong, Eun-Jung
    • Journal of Yeungnam Medical Science
    • /
    • v.26 no.1
    • /
    • pp.15-23
    • /
    • 2009
  • Constant technological developments in coronary artery disease have contributed to the assessment of both the presence of coronary stenosis and its hemodynamic consequences. Hence, noninvasive imaging helps guide therapeutic decisions by providing complementary information on coronary morphology and on myocardial perfusion and metabolism. This can he done using single photon emission computed tomography (SPECT) or positron emission tomography (PET) and multidetector CT (MDCT). Advances in image-processing software and the advent of SPECT/CT and PET/CT have paved the way for the combination of image datasets from different modalities, giving rise to hybrid imaging. Three dimensional cardiac hybrid imaging helped to confirm hemodynamic significance in many lesions, add new lesions such as left main coronay artery disease, exclude equivocal defects, correct the corresponding arteries to their allocated defects and identify culprit segment. Cardiac hybrid imaging avoids the mental integration of functional and morphologic images and facilitates a comprehensive interpretation of coronaty lesions and their pathophysiologic adequacy by three dimensional display of fused images, and allows the best evaluation of myocardial territories and the coronary-artery branches that serve each territory. This integration of functional and morphological information were feasible to intuitively convincing and might facilitate development of a comprehensive non-invasive assessment of coronary artery disease.

  • PDF

Discussions on Auditory-Perceptual Evaluation Performed in Patients With Voice Disorders (음성장애 환자에서 시행되는 청지각적 평가에 대한 논의)

  • Lee, Seung Jin
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.32 no.3
    • /
    • pp.109-117
    • /
    • 2021
  • The auditory-perceptual evaluation of speech-language pathologists (SLP) in patients with voice disorders is often regarded as a touchstone in the multi-dimensional voice evaluation procedures and provides important information not available in other assessment modalities. Therefore, it is necessary for the SLPs to conduct a comprehensive and in-depth evaluation of not only voice but also the overall speech production mechanism, and they often encounter various difficulties in the evaluation process. In addition, SLPs should strive to avoid bias during the evaluation process and to maintain a wide and constant spectrum of severity for each parameter of voice quality. Lastly, it is very important for the SLPs to perform a team approach by documenting and delivering important information pertaining to auditory-perceptual characteristics in an appropriate and efficient way through close communication with the laryngologists.