• Title/Summary/Keyword: Industrial cooler

Search Result 69, Processing Time 0.018 seconds

Weight Loss Prediction by Operating Conditions of CA Storage (CA저장고의 작동 환경에 따른 감모율 예측)

  • Park, Chun Wan;Park, Seok Ho;Kim, Jin Se;Choi, Dong Soo;Kim, Yong Hun;Lee, Su Jang
    • Food Engineering Progress
    • /
    • v.21 no.4
    • /
    • pp.312-317
    • /
    • 2017
  • Weight loss that influences quality and farmer incomes is affected by the storage environment of agricultural products. The interior of storage should be maintained at high humidity to prevent the weight loss of products which contain a lot of moisture. The research had constantly proceeded with change in the heat exchanger surface areas, humidity systems, and weight loss forecast to maintain high humidity within storage. Relative humidity that exerts an effect weight loss of crop is influenced by storage temperature, leak state, and volume of product. When weight loss is predicted, different conditions of these factors are derived. In case of CA storage, ways of forecasting the weight loss become easier compared to cold storage due to sealed storage with external environment during storage period. In this study, apples were stored in purge-type CA storage and weight loss has been predicted by using operating characteristics and environmental conditions. As a result, humidity variation in the storage fluctuates with the operation of the unit-cooler. Furthermore, unit-cooler operation factor is influenced by outside temperature and respiration heat. Prediction value of weight loss according to temperature and humidity has been most accurately predicted. Prediction value through defrosting water measured shows unit-cooler work quality. K-value needs verification to calculate the VPD method.

A Study on the Unidirectional Solidification of Oxygen Free Copper by the Horizontal Continuous Casting Process (수평식 연속주조법에 제조된 무산소동의 방향성 응고에 관한 연구)

  • Kim, Myung-Han;Lee, You-Jae;Jo, Hyung-Ho
    • Journal of Korea Foundry Society
    • /
    • v.14 no.6
    • /
    • pp.558-565
    • /
    • 1994
  • The horizontal continuous casting process with the heated mold was applied to obtain the unidirectionally solidified rods($4{\sim}8mm$ dia.) of pure copper with good surface quality. The results could be summarized as follows. 1. The unidirectional solidification of pure copper rods with good surface(mirror surface) quality could be obtained by placing the S/L interface inside the heated mold cavity even though the cast copper rods were covered with thin copper oxide layer. 2. The casting speed for 4mm dia. rods with mirror surfaces was affected significantly by the mold-cooler distance rather than the cooling flow rate when other casting conditions were fixed. 3. The casting speed was the main factor affecting the oxidation of copper during the continuous casting and the thickness of copper oxide layer decreased almost linearly as the casting speed increased.

  • PDF

A Study for Energy Separation of Vortex Tube using Air Supply System (I) - the effect of diameter of cold end orifice - (공기공급 시스템에 적용되는 Vortex Tube의 에너지 분리특성에 관한 연구(I) -저온출구 orifice의 직경변화에 의한 영향-)

  • 이병화;추홍록;상희선
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.9-18
    • /
    • 1998
  • The vortex tube is a simple device for separating a compressed gaseous fluid stream into two flows of high and low temperature without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air supply system. The phenomena of energy separation through the vortex tube was investigated experimentally. This study is focused on the effect of the diameter of cold end orifice diameter on the energy separation. The experiment was carried out with various cold end orifice diameter ratio from 0.22 to 0.78 for different input pressure and cold air flow ratio. The experimental results were indicated that there are an optimum diameter of cold end orifice for the best cooling performance. The maximum cold air temperature difference was appeared when the diameter ratio of the cold end orifice was 0.5. The maximum cooling capacity was obtained when the diameter ratio of the cold end orifice was 0.6 and cold air flow ratio was 0.7.

  • PDF

3-dimensional Numerical Analysis on Thermal Performance of an Oil Cooler (3차원 오일쿨러 방열성능 수치해석)

  • Park, Sang-Jun;Lee, Young-Lim
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11b
    • /
    • pp.944-946
    • /
    • 2010
  • 열교환기는 공조 및 기타 산업현장에서 많은 수요가 창출되고 있는데 본 논문에서는 3차원 수치해석을 이용하여 수송기계의 오일쿨러나 연료쿨러에 쓰이는 전형적인 열교환기에 대한 방열 성능을 해석하였다. 열교환기의 핀 타입 중 wavy 및 louver에 대하여 열교환기 성능 실험 데이터를 이용하는 3차원 열교환기 모델을 완성하고 통과 풍량에 따른 열교환량을 예측하였다. 이는 열교환기를 통과하는 풍속이 균일하지 않을 때 열교환량을 예측할 수 있어 설계 정확성 향상에 기여할 수 있다.

  • PDF

Early and Uniform Maturation in Silkworm Bombyx mori L. by Phytoecdysteroid Extracted from a Plant of Family Caryophyllaceae

  • Trivedy, Kanika;Nair, K.Sashindran;Ramesh, M.;Gopal, Nisha;Kumar, S.Nirmal
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.7 no.1
    • /
    • pp.65-68
    • /
    • 2003
  • One of the biggest problems encountered during the last phase of silkworm rearing is non-uniform maturation of the silkworms especially during cooler months. Phytoecdysteroid (20-hydroxy ecdysone) was extracted in large-scale from a plant belongs to Caryophyllaceae and fed to silkworm larvae to test the effect of phytoecdysteroid. About 80% of the silkworms were ready for mounting by 18 hrs after treatment (when the treatment is done for uniform spinning), whereas in control batch only 37% worms were ready for mounting by the same time.

Effect of Surfactant on Homogeneity of Partially Degummed Silk Fiber

  • Chung, Da Eun;Um, In Chul
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.28 no.1
    • /
    • pp.19-24
    • /
    • 2014
  • Silk has always been one of the most favored textile materials. Fully degummed silk fiber (i.e., silk fibers without sericin) shows better luster than raw silk fiber (with sericin); it is also softer. On the other hand, raw silk fiber feels cooler because of the presence of sericin, making it useful as a textile for the summer season. Recently, partially degummed silk has attracted researchers' attention because it provides better luster, feel, and dyeing properties. However, the partial degumming of silk is very difficult because it results in inhomogeneously degummed fiber. In the present study, silk yarns were degummed with surfactant aqueous solutions and the effects of each surfactant on the degumming ratio, crystallinity, and homogeneity of the degummed silk yarn were examined. The degumming ratio and crystallinity index of silk yarn varied depending on the type of surfactant. On the whole, anionic surfactants resulted in higher degumming ratios and better homogeneity than nonionic surfactants.

A Study for Energy Separation of Vortex Tube Using Air Supply System(II) - the effect of surface insulation - (공기공급 시스템에 적응되는 Vortex Tube의 에너지 분리특성에 관한 연구(II) -표면의 단열효과에 따른 영향-)

  • 방창훈;추홍록;유갑종
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.3-9
    • /
    • 1999
  • The vortex tube is a simple device which splits a compressed gas stream into a cold stream and a hot stream without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air supply system. In this study, the insulation effect of surface on the efficiency of vortex tube was performed experimentally. The experiment is carried out for nozzle area ratio of 0.194, diameter ratio of cold end orifice of 0.6 and input pressure ranging from 0.2Mpa to 0.5Mpa. The purpose of this study is focused on the effect of surface insulation of vortex tube with the variation of cold air mass flow ratio. The results indicate that the temperature difference of cold and hot air are higher about 12% and 30% than that of not insulated vortex tube respectively. Furthermore, for the insulated vortex tube, the similarity relation for the prediction of cold end temperature as the function of cold air mass flow ratio and input pressure is obtained.

  • PDF

Effects of the partial admission rate and cold flow inlet-outlet ratio on energy separation of Vortex Tube (Vortex Tube의 부분유입율과 저온 입.출구비가 에너지분리 특성에 미치는 영향)

  • 김정수;추홍록;상희선
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.3
    • /
    • pp.51-59
    • /
    • 1998
  • The vortex tube is a simple device for separating a compressed fluid stream into two flows of high and low temperature without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air conditioner for special purpose. The phenomena of energy separation through the vortex tube were investigated to see the effects of cold flow inlet-outlet ratios and partial admission rates on the energy separation experimentally. The experiment was carried out with various cold flow inlet-outlet ratios from 0.28 to 10.56 and partial admission rates from 0.176 to 0.956 by varying input pressure and cold air flow ratio. To find best use in a given cold flow inlet-outlet ratio and partial admission rate, the maximum temperature difference of cold air was presented. The experimental results were indicated that there are an optimum range of cold flow inlet-outlet ratio for each partial admission rate and available partial admission rate.

  • PDF

A Simple Thermal Model of Fuel Thermal Management System in Aircraft Engine

  • Youngjin Kim;Jeonghwan Jeon;Gonghoe Gimm
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.5
    • /
    • pp.11-18
    • /
    • 2023
  • The architecture of the Fuel Thermal Management System (FTMS) in a commercial aircraft engine was built to model and simulate the fuel system. The study shows the thermal interactions between the fuel and engine lubrication oil through the mission profile of a high bypass ratio, two-spool turbofan engine. Fuel temperature was monitored as it flowed through each sub-component of the fuel system during the mission. The heat load in the fuel system strongly depended on the fuel flow rate, and was significantly increased for the periods of cruise and descent with decrease of fuel flow rate, rather than for the periods of take-off. Due to the thermal interaction in the pump housing, the fuel temperature at the outlet of the low-pressure pump was increased (4.0, 9.2, and 30.0) % over the case without thermal interaction for take-off, cruise, and descent, respectively.

Experimental Study on Cooling Performance of Internal Heat Exchanger for CO2 Refrigerant System (이산화탄소 냉매 시스템용 내부 열교환기의 냉방성능에 관한 실험적 연구)

  • Kim, Dae-Hoon;Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.587-592
    • /
    • 2008
  • In order to investigate the performance of an internal heat exchanger for $CO_2$ refrigerant system, the experiment was performed. Four kinds of internal heat exchangers(IHX) were used. The effects on the IHX length, the number of tube, the operating condition and the type of IHX were investigated. With increasing of the IHX length, the capacity and efficiency increased. The pressure drop of the low-side was larger compared with that of the high-side. As the temperature of the gas cooler increased, the capacity and efficiency increased linearly. The operation condition of evaporator was suggested as two phase region rather than superheat region. The capacity and efficiency of the micro-channel was larger about 90% and 75% than those of the tube. But the pressure drop of the micro-channel was more larger, compared with that of the tube.