• Title/Summary/Keyword: Industrial Technology Leakage

Search Result 187, Processing Time 0.03 seconds

Application of a NDI Method Using Magneto-Optical Film for Micro-Cracks

  • Jaekyoo Lim;Lee, Hyoungno;Lee, Jinyi;Tetsuo Shoji
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.591-598
    • /
    • 2002
  • Leakage magnetic flux is occurred in the cracked area of magnetized specimens, and also it changes the magnetic domain area of the magneto-optical film positioned on the specimen. It causes the change of the optical permeability of the magnetic domain on the crack area. So crack images can be obtained easily using this principle. On the other hand, utilizing a laser in this method makes possible to perform a remote sensing by detecting the light intensity contrast between cracked area and normal area. This paper shows the application of non-destructive inspection system taking advantage of magneto-optical method for micro-cracks and presents examples applied to the several types of specimens having fatigue cracks and fabricated cracks using this method. Also the authors prove the possibility of this method as a remote sensing system under the oscillation load considering application to real fields.

Review on Sensor Technology to Detect Toxic Gases (독성가스 감지용 센서 기술 동향 리뷰)

  • Lee, Janghyeon;Lim, Si-Hyung
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.311-318
    • /
    • 2015
  • The excess use and generation of various toxic gases from many industrial complexes and plant facilities have increased the possibility of leakage or explosion accidents, which can cause fatal damage to human beings in the wide range of neighboring area. To prevent the exposure to the fatal toxic gases, it is very important to monitor the leakage of toxic gases using gas sensors in real time. Various types of gas sensors, which can be classified as semiconductor, electrochemical, optical, and catalytic combustion types according to the operating principles, have been developed. In this review, the operation principles of gas sensors are explained and the performance of those sensors is compared. The state-of-the-art gas sensor technologies developed by research institutes or companies are reviewed also.

A Study on the Activation Plan of the Support Systems for SMEs' Technology Protection (중소기업 기술보호 지원제도의 활성화 방안 연구)

  • Kim, Sung-won;Park, Hyun-ae;Lee, Hwansoo
    • Korean small business review
    • /
    • v.42 no.1
    • /
    • pp.1-17
    • /
    • 2020
  • As technology competition among companies has intensified, the importance of technology protection is increasing day by day. However, according to the status of technology leakage in Korea, the technology protection level of SMEs is weak. SMEs' technology leakage continues to occur, and the damage can be even more serious to SMEs. Thus, the government is operating various support systems for SMEs. However, despite the support system, the interest and use of SMEs is low. This study examines the current status of major support systems for SME technology protection in Korea, and empirically analyzes the recognition and expectation effects of companies on the support systems. Based on the results, this study discusses ways to improve the recognition and use of the support system. The results of this study will contribute to strengthening SMEs 'technology protection by increasing the utility and enhancing the utilization of the support systems.

A Study on the Lifetime Estimation and Leakage Test of Rubber O-ring in Contacted with Fuel at Accelerated Thermal Aging Conditions (가속노화조건 하 연료접촉 고무오링의 수명예측 및 누유시험 연구)

  • Chung, Kunwoo;Hong, Jinsook;Kim, Young-wun;Han, Jeongsik;Jeong, Byunghun;Kwon, Youngil
    • Tribology and Lubricants
    • /
    • v.35 no.4
    • /
    • pp.222-228
    • /
    • 2019
  • As rubber products such as O-rings, which are also known as packings or toric joints, come in regular, long term contact with liquid fuel, they can eventually swell, become mechanically weakened, and occasionally crack; this diminishes both their usefulness and intrinsic lifetime and could cause leaks during the steady-state flow condition of the fuel. In this study, we evaluate the lifetime of such products through compression set tests of FKM, a family of fluorocarbon elastomer materials defined by the ASTM international standard D141; these materials have great compression, sunlight, and ozone resistance as well as a low gas absorption rate. In this process, O-rings are immersed in the liquid fuel of airtight containers that can be expressed as a compression set, and the liquid fuel leakage in a flow rig tester at variable temperatures over 12 months is investigated. Using the Power Law model, our study determined a theoretical O-ring lifetime of 2,647 years, i.e. a semi-permanent lifespan, by confirming the absence of liquid fuel leakage around the O-ring assembled fittings. These results indicate that the FKM O-rings are significantly compatible for fuel tests to evaluate long-term sealing conditions.

Implementation of Film Type Sensor for Synthetic Lube Oil and High Pressure Hydraulic Fluid Leak Detection (합성 윤활유 및 고압 작동유 누출감지 필름형 센서의 구현)

  • Park, No-Jin;Yu, Dong-Kuen;Yu, Hong-Kuen
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.266-271
    • /
    • 2014
  • Chemical sensors are used in various industrial facilities such high-risk and prevent the leakage of substances, important in life and environmental protection and the safe use of industry, used for management. In particular, high-temperature environments such as power generation equipment of the rotating part due to leakage generated by the various oil, power plants Shut Down, fire, work environment (exposure to various chemical solution and gas leak) and various water, air and soil pollution causes. Thus, over the long term through various channels such as crops and groundwater contamination caused by the slow, serious adverse effect on the ecosystem. In this paper, synthetic lube oil and high pressure hydraulic fluid leakage and immediately detect a new Printed Electronic implementation of technology-based film-type sensors, and its performance test. Thus, industrial accidents and environmental pollution and for early detection of problems, large accidents can be prevented. Experimental results of the synthetic lube oil and high pressure hydraulic fluid solution after the contact time depending on the experiment and the oil solution of the sensor material of the conductive porous PE resistance value by a chemical reaction could be confirmed that rapid increase. Also implemented in the film-type oil sensor electrical resistance change over time of the reaction rate and the synthetic lube oil is about 2 minutes or less, the high pressure hydraulic fluid is less than about 1 minute was. Therefore, more high-pressure hydraulic fluid such as a low volatility synthetic lube oils are the resistance change and the reaction rate was confirmed to be the slowest.

Analysis of the Damaged Range Caused by LPG Leakage and Vapor Clouds Considering the Cold Air Flow (찬공기 흐름을 고려한 LPG 누출 및 증기운에 의한 피해 영향 범위 분석)

  • Gu, Yun-Jeong;Song, Bonggeun;Lee, Wonhee;Song, Byunghun;Shin, Junho
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.4
    • /
    • pp.27-35
    • /
    • 2022
  • When LPG leaks from the storage tank, the gas try to sink to the ground because LPG is heavier than air. The gas easily creates vapor clouds causing aggressive accidents in no airflow. Therefore, It is important to prevent in advance by analyzing the damaged range caused from LPG leakage and vapor clouds. So, this study analyzed the range of damaged by LPG leakage and vapor clouds with consideration of the cold air flow which is generated by the topographical characteristics and the land use status at night time in the Jeju Hagari. As a result of the cold air flow using KLAM_21, about 2 m/s of cold air was introduced in from the southeast due to the influence of the terrain. The range of damaged by LPG leakage and vapor cloud was analyzed using ALOHA. When the leak hole size is 10 cm at the wind speed of 2 m/s, the range corresponding to LEL 60 % (12,600 ppm) was 61 m which range is expected to influence in nearby residential areas. These results of this study can be used as basic data to prepare preventive measures of accidents caused by vapor cloud. Forward, it is necessary to apply CFD modeling such as FLACS to check the vapor cloud formation due to LPG leakage in a relatively narrow area and to check the cause analysis.

Garments Waterproofness Test Using Rain Tower System (인공강우시스템을 활용한 의복의 방수성능 평가)

  • Cha, Hee Chul;Park, Jun Ho;Lim, Jee Young;Shim, Huen Sup
    • Fashion & Textile Research Journal
    • /
    • v.17 no.6
    • /
    • pp.1013-1019
    • /
    • 2015
  • As the interest in leisure and health increases, the domestic outdoor wear industry becomes bigger. The waterproofness of fabrics does not ensure the waterproofness of garments because of the stitch holes during the sewing process even with the seam sealing tapes. Thus the water leakage often becomes a problem during the end use. Still companies use fabrics waterproofness data for garments marketing because they are simple to run the test, less expensive than the whole garment testing, and easy to achieve the quality control. In this study the rain tower system for evaluating the waterproofness of garments has been developed and the waterproofness of the selected waterproof and breathable garments in the market were tested. The rain tower was consisted of rain tower room, rainfall forming system and measurement system. Two different levels of rainfall can be simulated with this system(100l/m2/hr and 450l/m2/hr). Jackets in the market have been tested at two different rainfall conditions. The temperature and humidity data inside jackets didn't provide much information on the waterproofness at severe rainfall condition(450l/m2/hr, 1 hour). However, water leakage was detected on the cotton undershirt inside jacket. 5 out of 8 jackets passed the normal rainfall condition(100l/m2/hr, 30 minutes). The newly developed rain tower system was able to evaluate the waterproofness of the jacket seams. It is recommended the further study on the detailed test conditions for the end use of the waterproof and breathable garments.

Air Jet Effect on Performance Improvement of Non-Contact Type Seals for Oil Mist Lubrication Systems (공기분사가 오일미스트 윤활 시스템용 비접촉 시일의 성능 향상에 미치는 영향)

  • Na, Byeong-Cheol;Jeon, Gyeong-Jin;Han, Dong-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2159-2166
    • /
    • 2000
  • Recently, high performance machining center requires special type of sealing mechanism that prevent a leakage of oil jet or oil mist lubrication system. Sealing of oil-air mixture plays important r oles to have an enhanced lubrication for performance machining center. Current work emphasizes on investigations of the air jet effect on the protective collar type labyrinth seal. To improve sealing capabilities of conventional labyrinth seals, air jet is injected against the leakage flow. In this study, an adapted model is introduced to improve sealing capability of conventional non-contact type seals. It has a combined geometry of a protective collar type and an air jet type. Both of a numerical analysis by CFD (Computational Fluid Dynamics) and experimental measurements are carried out to verify sealing improvement. The sealing effects of the leakage clearance and the air jet magnitude aic studied in various parameters. Gas or liquid has been used as a working fluid for most of nori-contact types seals including the labyrinth seal. However, it is more reasonable to regard two-phase flows because oil mist or oil jet are used for high performance spindle's lubrication. In this study, working fluid is regarded as two phases that are mixed flow of oil and air phase. Both of turbulence and compressible flow model are also introduced in a CFD analysis to represent an isentropic process. Estimation of non-leaking property is determined by amount of pressure drop in the leakage path. Results of pressure drop in the experiment match reasonably to those of the simulation by introducing a flow coefficient. Effect of the sealing improvement is explained as decreasing of leakage clearance by air jetting. Thus, sealing effect is improved by amount of air jetting even though clearance becomes larger

Health Monitoring for Large Structures using Brillouin Distributed Sensing

  • Thevenaz, L.;Chang, KT.;Nikles, M.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.6
    • /
    • pp.421-430
    • /
    • 2005
  • Brillouin time-domain analysis in optical fibres is a novel technique making possible a distributed measurement of temperature and strain over long distance and will deeply modify our view about monitoring large structures, such as dams, bridges, tunnels and pipelines, Optical fibre sensing will certainly be a decisive tool for securing dangerous installations and detecting environmental and industrial threats.

Build and Performance Test of a 3-cell Solid Oxide Fuel Cell Stack

  • Cho, Nam-Ung;Hwang, Soon-Cheol;Han, Sang-Moo;Yang, Choong-Jin
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.8
    • /
    • pp.407-411
    • /
    • 2007
  • A 3-cell stacked anode-supported solid oxide fuel cell was designed and fabricated to achieve a complete gas seal and the facile stacking of components. The stack was assembled with a unit cell with $10{\times}10cm^2$ area, and each cell was interconnected by a stainless steel 430 separator using a proprietary sealant sheet. The stack performance was examined at various gas flow rates of $H_2+3.5vol%\;H_2O$, and air at a fixed temperature of $800^{\circ}C$. No gas leakage was found from the sealing between cells and inter-connects within a measurement system in this research during a prolonged time of 500 h in operation. The test resulted in an open circuit voltage of 3.12 V, a peak power of 149 W, and a power density of $0.61W/cm^2$, while the long term durability of the power showed 19.1% degradation during the prolonged time of 500 h when tested at $800^{\circ}C$.