• 제목/요약/키워드: Industrial Fan

검색결과 223건 처리시간 0.03초

경남지역 학교 급식조리실 개선 전후 환기성능 평가 (Evaluation of Ventilation Effectiveness Before and After Kitchen Renovation in Schools of Gyeongsangnam-do)

  • 손종원;김태형;하현철;김병훈
    • 한국산업보건학회지
    • /
    • 제34권1호
    • /
    • pp.35-47
    • /
    • 2024
  • Objectives: Many cases of lung cancer have been reported by school kitchen workers as occupational cancer. Twenty-eight schools in Gyeongsangnam-do Province were selected to evaluate the effect of improved kitchen ventilation systems. Ventilation characteristics before and after renovation were compared and design techniques were identified. Methods: In the design stage for kitchen ventilation systems, expert intervention was used to improve the designs. Ventilation characteristics and air quality were evaluated before and after the renovations. Hood face velocity and fan flow rate were measured and the smoke visualization technique was used to evaluate the capability of protecting worker's breathing zone. The concentrations of PM0.3 were measured at points not adjacent to cooking equipment because these concentrations fluctuate greatly. Results: Mean hood face velocity increased from 0.29 m/s before renovation to 0.7m/s after renovation. The concentrations of PM0.3 showed a roughly 95% reduction. Concentrations of CO showed more than a 75% reduction. Smoke visualization showed greater protection of workers' breathing zone. Conclusions: Advanced design techniques for school kitchen ventilation systems were applied to renovate old kitchen ventilation systems. The performance of the new kitchen ventilation systems was nearly excellent. Further improvement of design techniques is still needed, however.

Removal of Chromium (VI) by Escherichia coli Cells Expressing Cytoplasmic or Surface-Displayed ChrB: a Comparative Study

  • Zhou, Xiaofeng;Li, Jianghui;Wang, Weilong;Yang, Fan;Fan, Bingqian;Zhang, Chenlu;Ren, Xiaojun;Liang, Feng;Cheng, Rong;Jiang, Fengying;Zhou, Huaibin;Yang, Juanjuan;Tan, Guoqiang;Lyu, Jianxin;Wang, Wu
    • Journal of Microbiology and Biotechnology
    • /
    • 제30권7호
    • /
    • pp.996-1004
    • /
    • 2020
  • Various genetically engineered microorganisms have been developed for the removal of heavy metal contaminants. Metal biosorption by whole-cell biosorbents can be enhanced by overproduction of metal-binding proteins/peptides in the cytoplasm or on the cell surface. However, few studies have compared the biosorption capacity of whole cells expressing intracellular or surface-displayed metal-adsorbing proteins. In this study, several constructs were prepared for expressing intracellular and surface-displayed Ochrobactrum tritici 5bvl1 ChrB in Escherichia coli BL21(DE3) cells. E. coli cells expressing surface-displayed ChrB removed more Cr(VI) from aqueous solutions than cells with cytoplasmic ChrB under the same conditions. However, intracellular ChrB was less susceptible to variation in extracellular conditions (pH and ionic strength), and more effectively removed Cr(VI) from industrial wastewater than the surface-displayed ChrB at low pH (<3). An adsorption-desorption experiment demonstrated that compared with intracellular accumulation, cell-surface adsorption is reversible, which allows easy desorption of the adsorbed metal ions and regeneration of the bioadsorbent. In addition, an intrinsic ChrB protein fluorescence assay suggested that pH and salinity may influence the Cr(VI) adsorption capacity of ChrB-expressing E. coli cells by modulating the ChrB protein conformation. Although the characteristics of ChrB may not be universal for all metal-binding proteins, our study provides new insights into different engineering strategies for whole-cell biosorbents for removing heavy metals from industrial effluents.

공기흐름 변경으로 임펠러의 수명연장과 전력비 절감을 위한 송풍기 개발을 위한 실험적 연구 (Experimental Study for The Development of a Blower to Extend The Life of The Impeller and Reduce The Power Cost by Changing the Air Flow)

  • 김일겸;박우철;손상석;김용남
    • 한국산학기술학회논문지
    • /
    • 제21권11호
    • /
    • pp.219-225
    • /
    • 2020
  • 본 연구는 요구되는 전압효율이 83% 이상인 풍량 10,000 ㎥/min급의 장수명 송풍기를 개발하기 위하여 송풍기를 설계·제작하여 송풍기 성능시험과 침식 실험을 통하여 개발품에 대한 성능을 확인하였다. Dust deflector의 영향을 살펴보기 위하여 각기 다른 길이의 Dust deflector를 갖는 5가지의 실험용 임펠러를 제작하여 침식 실험을 수행하였다. 가혹한 조건으로 실험을 수행하기 위하여 침식을 유발하는 분진 대체재로 1kg의 스틸 쇼트 볼(𝛷0.2 mm)을 사용하였다. 자체 제작한 폐루프 타입의 침식 실험 장치에서 160시간 동안 연속으로 가동 운전하여 실험하였다. Dust deflector에 의한 침식성능을 평가하기 위하여 마모두께를 측정하였다. 3차원 스캐너로 침식 실험 전 형상과 침식 실험 후 형상을 스캐닝하여 마모두께를 측정하였다. 모델 송풍기를 설계·제작하여 송풍기 성능을 시험한 결과, 모델 송풍기 측정값을 기준으로 개발 송풍기로의 환산 결과 전압 690.6 mmAq, 풍량 16,243.6 ㎥/min, 효율 83.6 %로 나타났다. 송풍기의 침식 실험 장치를 설계·제작하여 가혹한 조건으로 침식 실험을 수행하여 dust deflector가 부착된 송풍기인 개발 송풍기가 dust deflector가 없는 기존 송풍기에 비하여 임펠러 마모두께를 기준으로 190 % 이상의 개선 효과가 있는 것으로 나타났다.

띠톱기계의 스마트 톱 절삭 시스템의 특성에 관한연구 (A study on the characteristics of intelligent sawing system for band saw)

  • 라로평;정택임;정협생;강평;팬리;샤오레이화;반백송;안보영;엄윤설;한창수
    • 한국산학기술학회논문지
    • /
    • 제21권2호
    • /
    • pp.195-204
    • /
    • 2020
  • 본 연구에서는 띠톱기계의 서로 다른 톱 절삭 상태에서, 최적의 톱 절삭력 및 최적의 컨트롤러 파라미터가 어떻게 설정 되는지에 대한 문제를 해결하기 위한 연구를 진행하였다. 이를 위해 띠톱 기계의 톱 절삭 시스템의 수학적 모형을 수립하고, 전통적인 PID 제어 방법과 톱 절삭력의 폐회로(closed-loop)제어에 대하여 병행하여 깊게 연구함으로써, 주 모터의 동력, 띠톱기계의 동적특성 및 톱날 강도 등의 컨트롤러 파라미터 및 톱 절삭 부하가 제어 성능에 대한 규칙을 발견하여, 톱 절삭 너비와 컨트롤러 파라미터(비례계수 Kp)의 관계, 톱 절삭력의 설정값의 관계를 얻어, 일종의 띠톱 기계의 스마트 톱 절삭 제어를 갖는 시스템 방안을 제기하였다. 연구 결과에 따르면 홈 절단면의 절삭 재료를 톱 절삭 시 스마트 톱 절삭 시스템의 톱 절삭 효율이 기존 톱 절삭 시스템보다 18.1㎠/min(48%) 향상 되였으며, 이 방안이 뛰어난 제어 효과를 가지고 있음을 보여 주었다.

의료용 초음파 프로브 상제균의 효과적인 소독법에 관한 연구 (A study on effective disinfection methods of medical ultrasound probe resident floras)

  • 윤준;김현주
    • 한국산학기술학회논문지
    • /
    • 제19권1호
    • /
    • pp.346-354
    • /
    • 2018
  • 의료용 초음파 장치의 프로브에서 일반적으로 검사자와 피 검사자가 접촉이 가장 많은 부위 중 무작위로 3부분을 임의로 선정하여 프로브에 상제하고 있는 병원균을 검출하여 병원균의 종류와 균수를 알아보았다. 또한 검출된 병원균에 대하여 프로폴리스 추출액, 소독용 에탄올, 소독용 티슈를 이용하여 각 각 소독 후 병원균의 사멸정도를 정량적으로 알아보았다. 그 결과 선형 프로브에서는 S. aureus(32.3%), Bacillus spp.(26.1%), Micrococcus spp.(21.5%), CNS(20%)가 검출되었고, 볼록형 프로브에서는 S. aureus(26.2%), Strepto coccus(24.3%), Entero coccus(19.5%), Micrococcus spp.(15.5%), CNS(14.6%), 부채꼴 프로브에서는 S. aureus(24.1%). Micrococcus spp(24.1%), Entero coccus(20.7%), Strepto coccus(17.2%), CNS(13.8%)순으로 검출되었다. 검출된 병원균을 대상으로 소독을 위해 선정한 3가지 소독액을 이용하여 소독한 결과 소독용 에탄올의 경우 대부분의 병원균을 사멸시켰으며 최소 91.3 %에서 최대 100 %의 사멸효과로 가장 큰 소독 효과가 있는 것으로 분석되었다(P>0.05). 또한 프로폴리스 추출액과 소독용 티슈의 경우 모든 소독용 에탄올에 비해 소독효과는 낮았으나 소독효과에는 통계적으로 유의한 것으로 분석되었다(P>0.05). 실험결과를 보면 대부분의 초음파 프로브에서 다양한 병원균이 검출되었으며, 소독용 에탄올, 소독용 티슈의 소독효과가 있었으며 특히 프로폴리스 추출액을 이용한 소독도 병원균 사멸에 효과가 있는 것으로 분석되어 향 후 검사자와 피검사자의 접촉이 많은 초음파 프로브 소독 시 적용한다면 감염예방에 있어 도움이 될 것으로 사료된다.

띠톱기계 톱대의 역학적 모델링 및 설계 (The Mechanical Modeling and design of saw frame in band sawing machine)

  • 라로평;정택임;정협생;강평;팬리;샤오레이화;반백송;안보영;노준규;리원치;한창수
    • 한국산학기술학회논문지
    • /
    • 제20권12호
    • /
    • pp.390-397
    • /
    • 2019
  • 현대 제조 공업이 고효율, 고정밀도와 경제적인 방향으로 발전 하면서 금속을 절단하는 띠톱 기계는 이미 철강, 기계, 자동차, 조선, 석유, 광산, 항공 우주 등 다양한 영역에서 광범위 하게 활용 되고 있다. 하지만 기존의 띠톱 기계들은 경험적으로 설계 되어져 왔으며 따라서 낮은 수명, 톱질 동작 상태에서 낮은 정밀도 및 저효율을 문제와 높은 제조원가 문제를 가지고 있다. 본 논문에서는 띠톱의 역학적 해석을 통해 띠톱 톱대의 설계 파라미터를 개선하는 방법을 제시 하였다. 실제로 빈번하게 사용 되고 있는 띠톱 기계를 모델링 하여 응력 분석, 피로해석을 시행 하였으며 이에 따라 톱대의 상세한 설계 파라미터를 도출 하였다. 그 결과 피로 강도가 피로 요구 사항을 만족 시키고 띠톱 기계의 정밀도와 효율이 크게 향상 되는 것을 확인할 수 있었다.

스프레이 코팅 룸의 온도분포 해석 (Analysis of Temperature Distributions in Spray Coating Room)

  • 김남웅;김성용;김국원
    • 한국산학기술학회논문지
    • /
    • 제16권11호
    • /
    • pp.7667-7671
    • /
    • 2015
  • 아연말 코팅은 친환경성 및 고성능으로 인하여 널리 사용되고 있다. 일반적으로 코팅온도가 코팅층 두께 및 코팅품질을 결정하는 주요한 요소이므로 아연말 코팅의 경우에도 최적의 코팅온도가 요구되고 있다. 본 연구에서는 아연말 스프레이 코팅 룸의 온도분포를 해석하기 위해 룸 내부의 공기유동을 포함하는 열 유동 전산 시뮬레이션을 수행하였다. 3차원 CAD 프로그램인 SolidWorks를 이용하여 스프레이 코팅 룸 전체와 예열실과 건조실을 모두 고려한 모델링을 수행하였으며 Flow Simulation 프로그램을 이용하여 열 유동 해석을 수행하였다. 해석된 결과는 열화상카메라를 이용한 실험으로 검증하였다. 해석결과 제1스프레이실과 제2스프레이실의 온도분포 특성을 파악할 수 있었으며, 현재의 상태로는 목표 온도 값인 $25^{\circ}C$에 미달하고 있었음을 알 수 있었다. 단순히 히터를 추가하는 방법 대신, 현재 조건에서 스프레이실의 온도를 높이는 방안으로 배기팬을 사용하지 않는 경우에 대해 시뮬레이션을 수행하였으며, 그 결과 제1스프레이실의 온도가 $6.2^{\circ}C$, 제2스프레이실의 온도가 $5.8^{\circ}C$ 상승하였다. 본 연구 내용은 향후 스프레이 코팅 룸의 성능향상을 위한 설계에 이용될 수 있다.

화학적 초미세 발포 사출성형을 이용한 에어컨 드레인 펜의 공정 최적화에 대한 연구 (A study on the process optimization of microcellular foaming injection molded air-conditioner drain pen)

  • 김주권;곽재섭;김준민;이준한;김종선
    • Design & Manufacturing
    • /
    • 제11권2호
    • /
    • pp.1-8
    • /
    • 2017
  • In this study, we applied microcellular foaming injection molding process to improve the performance of system air-conditioner drain fan which had been produced by injection molding process and studied the optimization of process conditions through 6-sigma process and response surface method (RSM) to reduce weight and deformation of products. Additive type, melt temperature, mold temperature, and injection screw shape were selected as the factor affecting the weight and deformation of the products by carrying out analysis of trivial many through ANOVA and design of experiment (DOE) method. Among the effect factor, we set the addictive type to Long G/F and screw shape to foaming screw which had the highest level of weight reduction and deformation reduction. The amount of foaming agent gas was set at 60 ml, which was the limit beyond which the weight of product did not decrease any more. For melt temperature and mold temperature, we studied the conditions where both weight and deformation were minimized using the RSM. As a result, we set the melt temperature to $250^{\circ}C$, fixed mold temperature to $20^{\circ}C$, and moving mold temperature to $40^{\circ}C$. The improvement effect was analyzed by appling the selected optimal conditions to the production process using the microcellular foaming injection molding. The results showed that the mean weight of product was measured to be 1,420g which was 19% lower than that measured in the current process. The standard deviations of the weights were found to be similar to those in the current process and it showed a low dispersion. The mean deformation was measured to be 0.9237mm, which represented a 57% reduction compared to the mean deformation in the current process, and the standard deviation decreased from 0.3298mm to 0.1398mm. Moreover, we analyzed the process capability for deformation, and the results showed that the short-term process capability increased from 2.73 to 6.60 which was even higher than targeted level of 6.0.

공기흐름 변경으로 임펠러의 수명연장과 전력비 절감을 위한 송풍기 개발을 위한 수치해석 (Numerical Analysis for the Development of a Blower to Extend the Life of the Impeller and Reduce Power Costs by Changing the Air Flow)

  • 김일겸;박우철;손상석;김용남
    • 한국산학기술학회논문지
    • /
    • 제21권12호
    • /
    • pp.192-199
    • /
    • 2020
  • 본 연구는 요구되는 전압효율이 83% 이상인 풍량 10,000 ㎥/min급의 장수명 송풍기를 개발하기 위하여 송풍기 침식 현상을 조사하고, 수치해석을 통하여 송풍기 성능과 송풍기 침식을 예측하였다. 송풍기 해석에 주로 많이 사용되는 검증된 상용코드인 ANSYS CFX 13.0을 사용하여 수치해석을 수행하였다. 수치해석에 사용된 조건은 풍량 16,200 ㎥/min, 회전수 893 rpm, 온도 330 ℃이다. 분진의 비중은 3.15이고, 입도는 90㎛~212㎛이며, 양은 265kg/min으로 하였다. 송풍기로 유입되는 분진으로 인한 송풍기의 침식현상을 정확히 해석하기 위하여 수직복원계수의 변화에 따른 침식 현상을 실제 침식현상과 비교하였다. Finne 모델을 적용하여 수치해석을 수행한 결과 평형복원계수는 1, 수직복원계수는 0.1인 경우가 실제 침식현상과 유사하게 나타났다. Duct deflector가 침식에 관하여 미치는 영향을 살펴보기 위하여 Duct deflector가 있는 모델과 없는 모델을 비교하여 침식해석을 수행하였다. 수치해석의 결과, Duct deflector를 설치한 경우 Impeller에서 평균 167% 감소하고, Boss에서는 평균 133% 증가하는 경향으로 나타났다. Dust deflector의 길이에 따라 총 5가지 모델을 생성하고, 이에 대하여 침식 수치해석을 수행하였으며, 길이가 가장 긴 Case 5가 침식성능이 가장 우수한 것으로 나타났다. Case 5의 송풍기 성능은 회전수 880 rpm, 풍량 16,200 ㎥/min일 경우, 전압 691.7 mmAq와 전압효율 83.3%로 나타났다.

설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010)

  • 한화택;이대영;김서영;최종민;김수민;권영철;백용규
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.