• 제목/요약/키워드: Industrial Fan

검색결과 223건 처리시간 0.033초

축류형 팬의 저소음화에 관한 연구 (A Study on the Noise Reduction of Axial Flow Fan)

  • 오재응;이승종;이상환;이동익;김철환
    • 설비공학논문집
    • /
    • 제7권1호
    • /
    • pp.142-149
    • /
    • 1995
  • Axial fans are very useful cooling devices being widely used in many electric and industrial machinery. However those are often accompanying annoying noise. Many efforts have been devoted in order to reduce the fan noise. In this study, the procedure was devided into two major parts in considering effects of design parameters of axial fan concerned with noise ; the fan theory and the Fukano's fan noise study. By using the fan theory we defined stagger angle, camber angle, blade inlet and outlet angle for studying low noise fan. Then the effects of such angles on the flow rate and static pressure were investigated. By using the Fukano's fan noise theory, the relations of the chord length, the rotational speed and the number of blades vs. fan noise are investigated.

  • PDF

Crossflow Fan 주변의 유동 (Flows around crossflow fan)

  • 김재원;정윤영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.678-683
    • /
    • 2001
  • The present work has carried out experimental study on a cross-flow fan system with a simplified vortex wall scroll casing. A cross-flow fan test rig was constructed to obtain pressure rise and volume flow rate for various fan operating conditions. The performance estimation is using a wind tunnel with a motor driven damper for flow rate control and flows are quantitatively visualized by light scattering system with a pulsed laser. Min focus on the visualization is finding a eccentric vortex inside a fan which is a major factor reducing fan efficiency. Comprehensive engineering data are prepared for industrial applications and show a good agreement with a prior work by experimental measurements.

  • PDF

산업용 터보팬의 진동절연에 관한 연구 (The Study on Vibration Isolation of Industrial Turbo-fan)

  • 박익필;김동영;권용수;안찬우
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.609-615
    • /
    • 2001
  • A turbo-fan is easily exposed to noise and vibration as against other industrial machines and the majority of them is subject to be damaged by vibration. The most usual problem of vibration in a turbo-fan is resonance so the case of being composed of iron sheet structure with low strength like a turbo-fan should be taken seriously. In this paper, FFT(Fast Fourier Transform) and Order tracking method were used to analyze factors of vibration in a turbo-fan and hereby with proper selection of vibration isolator, we wanted to reduce vibration of base. After Order tracking, we knew resonance occurred in rotational frequency 23 Hz(1400 rpm) at the casing and the bearing. After the test of base vibration using vibration isolators, the spring isolator was more effective than the robber isolator in the base vibration and the vibration isolating is more effective in the case that the isolating pad is adhered to the bottom of the isolating spring.

  • PDF

수조 내의 팬의 위치선정에 관한 수치적 연구 (Numerical Study on Selection by the Location of Pan in water pool)

  • 박성수;도영민;유재환
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 2000년도 춘계 학술논문발표회 논문집
    • /
    • pp.42-46
    • /
    • 2000
  • In this numerical study, characteristics of swirl generation by the fan and selection of the location of the fan was studied theoretically by the PHOENICS soft ware. The governing equations for the system are solved by means of the three dimensional version of the SIMPLE algorithm and STAGGERED grid. From the present results, the optimal position of the fan is 0.625($\ell$/L). Here we can survey the big swirl near the fan.

  • PDF

산업용 조정 피치형 축류송풍기의 성능예측에 관한 연구 (Study on Performance Prediction of Industrial Axial Flow Fan with Adjustable Pitch Blades)

  • 구재인;김창수;정진택;김광호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.30-34
    • /
    • 2001
  • In the present study, we studied the method of predicting the on-design and on-design point performance of axial flow fan with adjustable pitch blades. With the change of stagger angle of axial flow fan with adjustable pitch blade, flow rate and pressure can be changed. Because of this merit adjustable pitch fans are used in many industrial facility. When changing stagger angle or estimating the performance at a wide range of off-design condition, incidence angle changes greatly as the flow rate changes. Therefore, the deviation angle at the blade exit is estimated by the correlation considering the effects of blade design, incidence angle variation. In the loss model, we used known pressure loss model for blade boundary layer and wake, secondary flow, endwall boundary layer and tip leakage flow. The results of modified deviation angle model and experiment were compared for the usefulness of the modified model.

  • PDF

배기용 Fan Scroll에 대한 연구 (A Study on the Fan and Scroll for Ventilation)

  • 송성배;박성일;이준세
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.402-406
    • /
    • 2000
  • In the Over-The-Range, the outlet size is limited by the industrial standards. Therefor to enlarge the volume of cavity, the installation height of ventilation fan is become small, the system resistance is higher than before. For that reason, the important design variables such as the diameter of a fan, the scroll expansion angle, etc. which play the significant role on flow rate and noise, are confined. In this study, we made an experiment of the diameter of fans relation to scroll expansion angle and investigated flow rate of the length of fans in enlarged cavity volume of OTR, and then we designed the new scroll to improve the flow rate and noise level. As a result, flow rate increased to 110% compared to current scroll and the blade passing frequency of a fan is disappeared by inclined cut-off shapes.

  • PDF

축류형 흡입송풍기 설계기술에 관한 연구 (A Study of Design Method of an Axial-Type Suction Fan)

  • 최형준;김창수;조종현;조수용
    • 한국유체기계학회 논문집
    • /
    • 제13권1호
    • /
    • pp.42-51
    • /
    • 2010
  • Many different types of fan have been applying to various industrial fields. Fan design methods are much different depending on the types of fan, operating conditions, and connecting parts at the inlet or exit of the fan etc. In this study, design methods for an axial-type suction fan are studied. This fan discharges the air in the relative static pressure of -285Pa to the atmosphere with the flow rate of $960m^3/min$. For three-dimensional blade design, three different design methods were applied, such as the free vortex method, the exponential method, and the cascade method. In the cascade method, the blade loading along the radial direction was obtained from the lift coefficient which was necessary to obtain the pressure rise on a fan rotor. This method is different from the free vortex and the exponential method which control the strength of the vortex. The fan performance prediction was conducted using the CFD with three different inlet ducts. The best fan performance was obtained when the fan was designed by using the cascade method. The designed fan using the exponential method showed better performance compared to a fan designed using the free vortex method. However, the fan performance was changed depending on the installed inlet ducts. So, an efficient fan can be designed with the adjustment of design variables on the basis of the flow structures within the fan as well as the fan design procedure.

Optimum Design of Volute Configuration in a Sirocco Fan using CFD and DOE

  • Jung, Uk-Hee;Choi, Young-Seok;Lee, Kyoung-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권2호
    • /
    • pp.68-73
    • /
    • 2009
  • In this paper, a numerical study has been carried out to investigate the influence of volute geometries on the performance of a sirocco fan. In order to achieve an optimum volute design and explain the interactions between the different geometric configurations in the volute system, three-dimensional computational fluid dynamics and the 'design of experiment' method have been applied. Several geometric parameters, such as the volute expansion angle, the cut-off position and the bell mouth shape, are employed to improve efficiency and performance. $2^k$ factorial designs were performed to screen the most influential parameters and interactions, and showed that the cut-off position and the bell mouth shape are the most significant parameters. The optimum design was selected as a result of the response surface methodology, and effects of these parameters and their interactions were presented. From the results of computational analyses and experimental data, the performance and efficiency of the sirocco fan were successfully improved. Also, detailed effects of geometric variables of the volute system on the fan performance were discussed.

리어가이더 형상변화에 따른 횡류홴 성능해석 (Analysis of Performance of Cross-Flow Fan with Various Rear Guiders)

  • 김동원;이준환;박성관;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2076-2082
    • /
    • 2003
  • A cross-flow fan is widely used on many industrial fields: mining industry, automobile and home appliances, etc. The design point of the cross-flow fan is generally based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between 30% and 40% because of relative high impact loss. Recently, in the air-conditioning systems, the operating behaviors at the off-design points are highly regarded to broaden the application area for various air-cooling loads. Especially, at the lower flow rate, there exists a rapid pressure head reduction, a noise increase and an irregular flow field against a rearguider as a scroll of centrifugal fan. Numerical analyses are carried out for investigating the flow characteristics in a cross-flow fan including the impeller, the rearguider and the stabilizer. Especially, various types of rearguiders are estimated by numerical and experimental methods to insure the stable operation in the region of lower flow rate. Numerical domains are discretized by hexahedral cells. Three-dimensional, unsteady governing equations are solved using FVM, PISO algorithm, sliding grid system and standard ${\kappa}-{\varepsilon}$ turbulence model. ASHRAE standard fan tester is also used to estimate the performance of the modeled crossflow fan.

  • PDF

Turbo Fan 형상에 따른 맥동압력에 관한 수치해석 (A Numerical Analysis on Pressure Pulsation with Turbo Fan Shape)

  • 이중섭;서정세;송철기;홍정규;신유인
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1355-1360
    • /
    • 2009
  • This study simulates the flow characteristics of the turbo-fan which was applied to the industrial scale. Numerical analysis has been carried out to investigate a pulsation behavior of exhaust air that flow out the turbo fan, considering a constant rotating rate of impeller. Moving mesh technique provides time-accurate solutions for the flow inside an impeller. From the numerical results, FFT analysis has been made for pressure pulsations inside turbo-fan casing. The numerical simulation shows the pulsation of model-2 has higher than model. Additionally, BPF value is almost same as the numerical results.

  • PDF