• Title/Summary/Keyword: Industrial Energy Usage

Search Result 123, Processing Time 0.025 seconds

A study of Energy Oriented Urban Development Model for Industrial Complex plan

  • Kim, Sang-hyun
    • Journal of Korea Technology Innovation Society
    • /
    • v.8 no.1
    • /
    • pp.209-219
    • /
    • 2005
  • o Korea consumed total 198.5 million TOE and the portion of crude oil n was 100.4 million TOE in 2002 which marked the 10th largest energy consuming country and ranks the $4^{th}$ crude oil consumer in the world. o Industries consumed 51.5% of the total energy and 93% of industrial energy was used at the manufacturing industries such as steel, textile, chemical, food and beverage, pulp and paper, and timber industries, which lead to energy intensive industries numbered 110,000. o Also Korea ranks the $10^{th}$ greenhouse gas emission countries of the world (134.9 million TC) which may cause Korean industries to suffer severely during the implementation of United Nations Framework Convention on Climate Change (UNFCCC). o Therefore, the target of the study is to develop a model for the analysis and design of industrial complex by integration of the energy usage and environmental problems. o The research work contents are as followings: -Analysis of Korea energy consumption -Concept of the integration of energy and environment problems - Basic concept of industrial complex planning - Case study (1) - Recommendation and conclusion

  • PDF

An Efficient Energy Usage of Wireless Sensor Network (무선 센서 네트워크에서 에너지의 효율적 사용방법)

  • Oh, Se-Jun;Hur, Sun;Lee, Gun-Woo
    • IE interfaces
    • /
    • v.23 no.2
    • /
    • pp.108-117
    • /
    • 2010
  • Wireless sensor network may be installed where it is hard to access or where one has to constantly gather data without any human's monitoring. Sensors which compose a sensor network are usually small with poor battery capacities and thus energy-efficient usage is very important because of difficulties in replacing or recharging the batteries to make the lifetime of the whole sensor network longer. LEACH protocol, a well-known hierarchical routing protocol, may resolve this problem by distributing the role of cluster header evenly to the sensor nodes in the whole area of network at each round. In this thesis, we introduce a variant of LEACH protocol which considers the distance between base station and sensors in the way that if a node is far from the base station then the probability that this node becomes a cluster header is low. Experiments to evaluate the energy efficiency and the ability to collect the information show that the proposed method in this paper has maintained much wider sensing area while keeping the energy efficiency same as LEACH.

Compact module and control system for district heating system (지역난방용 콤팩트 유닛 및 제어기 개발)

  • Lee, Young-Soo;Baik, Young-Jin;Jung, Dae-Hun;Kim, Jin;Um, Chul-Jun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1343-1347
    • /
    • 2009
  • In order to comply with the global energy crisis and environment problem, it is necessary to research and develop the energy utilization technology with the reduction of the primary energy usage. Although the increasing rate of energy consumption started to attenuate, the entire consumption of energy as well as $CO_2$ emission rate tends to increase steadily along with an economic growth in Korea. The energy demand in Korea increases by annual 3.7% during the period from 2000 to 2006. And it is expected that we should take a charge of the greenhouse gas reduction obligation by the Climatic Change Convention(Kyoto Protocol) during the 2nd pledge period($2013{\sim}2017$). According to the IEA report in 2005, the emission amount of carbon dioxide is the 10th place in the world, and the increasing rate is 4.7% annually. Considering the economic scale of Korea, the degradation of energy usage is inevitable when the greenhouse gas reduction obligation come into effect. Therefore, effective energy usage is a very important issue to minimize baneful influence on industrial and economic activities.

  • PDF

Study on TES system application for industrial production facility (축냉시스템의 산업용 생산설비 적용에 대한 고찰)

  • Park, C.H.;Hong, S.S.;Kim, J.R.;Park, S.S.;Hwang, H.S.
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1288-1293
    • /
    • 2009
  • The TES (Thermal Energy Storage) cooling system utilizing cheaper off-peak electricity has been applied just for building air-conditioning currently and causes limitation of usage rate and inefficiency of national resources utilization. In this regard, more says the necessity to apply TES system in industrial cooling system which is longer using period and wider usage. In this study, we will approve the technical and economical improvement in efficiency of industrial cooling system applied TES system by utilizing cheaper off-peak electricity and it will attribute the promotion of TES system and stabilization of supply and demand of electric power by proving the necessity to develop more efficient industrial cooling system by combining TES system.

  • PDF

An On-line System Architecture for Remote Energy Monitoring of CNC Machine Tools (CNC 기계의 원격 에너지 모니터링을 위한 온라인 시스템 구조)

  • Nam, Sung-Ho;Song, Ki-Hyeong;Baek, Jae-Yong;Lee, Dong-Yoon;Ryu, Kwang-Yeol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.5
    • /
    • pp.480-485
    • /
    • 2013
  • Enhancing energy efficiency of machine tools causes substantial impacts on the manufacturing industries, to cope with the competitive introduction of the total energy management strategies. Real-time energy monitoring is essential to identify energy consumption patterns of the machine tools and correlate them with the energy management strategy. Integrated analysis of machine tool's operation status and the corresponding energy usage is most important to accurately evaluate the energy efficiency under the various machining process environments. This paper proposes a system architecture to realize the online energy monitoring system and the embedded energy monitoring approach interconnected with the CNC kernel. The shop-floor operation management system is presented to integrate the proposed online energy monitoring approach.

Measuring the Efficiency of Investment in the Deployment and Technology Development of Renewable Energy in Korea Using the DEA (DEA를 이용한 국내 신재생에너지 보급 및 기술개발 투자의 효율성 분석)

  • Kim, Hong-Hee;Lee, Deok-Joo;Kim, Kyung-Taek;Park, Sung-Joon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.40 no.4
    • /
    • pp.358-365
    • /
    • 2014
  • The purpose of this paper is to analyze the efficiency of government investment in the deployment and technological development of three technological areas - wind power, photovoltaic and fuel cell - of renewable energy in Korea using the DEA (data envelopment analysis). The efficiencies of government investment in renewable energies are measured and compared among three kinds of technologies using the actual data during 2007~2009. In the present DEA model, R&D investment and government subsidies for renewable energy usage promotion are selected as input variables, and the number of patents, supply level, and the production cost as output variable. As a result, it is found that the wind power is the most efficient renewable energy in Korea in the perspective of the efficiency of government investment.

A Study on the Introduction of MFCA for Emergy Saving in Supply Chain (공급사슬망의 에너지 절약을 위한 MFCA 도입 방안 연구)

  • Lee, Doo-Yong;Jang, Jung-Hwan;Zhang, Jing-Lun;Jho, Yong-Chul;Lee, Chang-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.4
    • /
    • pp.147-152
    • /
    • 2012
  • Supply chain including transportation expend the 21% of domestic energy consumption. It is necessary to diminish the excess energy usage at entire supply chain. This paper deals with the application of MFCA(Material Flow Cost Accounting) for SCM to save energy consumption. We construct the material center corresponding to each logistics function in order to apply the MFCA for GCM(Green Chain Management). We also construct the MFCA framework which consists of MFCA Database Management, MFCA Visualization, GCM Data Integration, GCM Data Tracking, and MFCA Data Predict & Assignment. We expect to help determining the range of logistics function to apply the MFCA for GCM.

Development of 1kW Class PEFC System for Residential Applications (1kW급 가정용 연료전지 시스템 실증 연구)

  • Choi, Dong-Min;Shin, Bum-Su;Park, Yon-Goo;Ham, Mi-Sook;Shim, Jae-Hwi
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.174-176
    • /
    • 2008
  • HYOSUNG manufactured and tested 1kw class PEFC systems to generate electrical and thermal energy for each residential usage. In particular, HYOSUNG developed Power conditioning system that performs about 91% electrical conversion ratio specified in 1kW class PEFC systems. Prior to system integration, we tested each performances of components to derive control issues from it. In addition, we have been developing the adequate simulator to describe and predict system performance. In this paper, we verified HYOSUNG's 1kW class PEFC systems are valid for residential energy sureces by testing the characteristics of systems and performances of main component.

  • PDF

Energy Saving and Development of an Industrial Regenerative Oxy-Fuel Combustion Furnace for CO2 Capture (에너지 절약 및 이산화탄소 포집을 위한 축열식 순산소 연소로 개발)

  • Oh, Jeongseog;Noh, Dongsoon;Lee, Daegeun;Hong, Sungkook;Yang, Jebok;Ko, Changbok;Lee, Eunkyung
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.121-122
    • /
    • 2013
  • In recent years, the usage of fossil fuels has caused problems of climate change and global warming. Because the combustion of fossil fuels is related to the production of greenhouse gases ($CO_2$, $CH_4$, etc.), new technology in the field of combustion is needed in order to handle the crisis of climate change and the global warming. As one of the efforts to reduce the emission of greenhouse gases, the concept of regenerative oxy-fuel combustion for energy efficiency and carbon capture was suggested, In the current study, the development of an industrial regenerative oxy-fuel combustion furnace was introduced, which has been being performed at Korea Institute of Energy Research (KIER).

  • PDF

The Forecasting Power Energy Demand by Applying Time Dependent Sensitivity between Temperature and Power Consumption (시간대별 기온과 전력 사용량의 민감도를 적용한 전력 에너지 수요 예측)

  • Kim, Jinho;Lee, Chang-Yong
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.1
    • /
    • pp.129-136
    • /
    • 2019
  • In this study, we proposed a model for forecasting power energy demand by investigating how outside temperature at a given time affected power consumption and. To this end, we analyzed the time series of power consumption in terms of the power spectrum and found the periodicities of one day and one week. With these periodicities, we investigated two time series of temperature and power consumption, and found, for a given hour, an approximate linear relation between temperature and power consumption. We adopted an exponential smoothing model to examine the effect of the linearity in forecasting the power demand. In particular, we adjusted the exponential smoothing model by using the variation of power consumption due to temperature change. In this way, the proposed model became a mixture of a time series model and a regression model. We demonstrated that the adjusted model outperformed the exponential smoothing model alone in terms of the mean relative percentage error and the root mean square error in the range of 3%~8% and 4kWh~27kWh, respectively. The results of this study can be used to the energy management system in terms of the effective control of the cross usage of the electric energy together with the outside temperature.