• 제목/요약/키워드: Induction motors

검색결과 747건 처리시간 0.025초

동적인 부하를 고려한 전력계통의 안정도 해석 (Power System Stability Analysis Considering Dynamic Loads)

  • 박지호;백영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.187-189
    • /
    • 2001
  • In this paper, we have simulated the transient stability of power system with dynamic loads. Dynamic load characteristics have an important influence on power system stability. In study of power system stability, motors form a major portion of the system loads. Induction motors and synchronous motors in particular form the workhorse of the electric power industry. Therefore modelling of motors is important in system stability. We investigate the effect of motors loads of Kwang Yang network with three phase fault.

  • PDF

잔류자기와 I 결선에 의한 3상유도전동기 고정자 권선의 극성판별법에 대한 연구 (A Study on the Polarity Discrimination Method of the Stator Windings for 3 Phase Induction Motors based on the Residual Magnetism and I Winding Connection)

  • 최순만
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.72-77
    • /
    • 2015
  • When connecting 6 lead wires from stator windings to the terminals of 3 phase induction motors for Y or ${\triangle}$ connection, it is feared that the polarities of windings could be reversed each other if the wire tags are lost or erased, resulting in inadmissibly high current to motors in case of starting. To protect motors against such situations, some test procedures are necessary during wire connection which need to be easy ways to electricians without particular tools except a general multi-tester and with less time-consuming in the field. This study focuses on a test measure to satisfy these requirements which is able to provide them a convenient procedure for winding polarity discrimination considering the field condition. Here, the proposed measure utilizes the residual magnetism of the rotor and checks the indication of voltage or current at windings which are induced by the residual flux of rotor when rotating it by hands with 3 stator windings connected in the form of I connection. Principle characteristics and experiment results for this method are analyzed in the view of the effectiveness and applicability for the winding polarity discrimination.

테슬라(TESLA) 전기자동차 핵심 기술동향 (The Core Technical Trends of TESLA EV(Electric Vehicle) Motors)

  • 배진용;김용
    • 전력전자학회논문지
    • /
    • 제22권5호
    • /
    • pp.414-422
    • /
    • 2017
  • This paper reviews the core technical trends of TESLA EV Motors. The TESLA EV Motors is explosively popular with a considerable recharging infrastructure, a wide 17-[inch] touch display, 417 [HP], and 378 [km] going distance. The object of this study analyzes the body appearance, motor and, battery cooling system, battery arrangement, battery management system, super charging station, power electronics, and induction motor.

Stator Current Processing-Based Technique for Bearing Damage Detection in Induction Motors

  • Hong, Won-Pyo;Yoon, Chung-Sup;Kim, Dong-Hwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1439-1444
    • /
    • 2005
  • Induction motors are the most commonly used electrical drives because they are rugged, mechanically simple, adaptable to widely different operating conditions, and simple to control. The most common faults in squirrel-cage induction motors are bearing, stator and rotor faults. Surveys conducted by the IEEE and EPRI show that the most common fault in induction motor is bearing failure (${\sim}$40% of failure). Thence, this paper addresses experimental results for diagnosing faults with different rolling element bearing damage via motor current spectral analysis. Rolling element bearings generally consist of two rings, an inner and outer, between which a set of balls or rollers rotate in raceways. We set the experimental test bed to detect the rolling-element bearing misalignment of 3 type induction motors with normal condition bearing system, shaft deflection system by external force and a hole drilled through the outer race of the shaft end bearing of the four pole test motor. This paper takes the initial step of investigating the efficacy of current monitoring for bearing fault detection by incipient bearing failure. The failure modes are reviewed and the characteristics of bearing frequency associated with the physical construction of the bearings are defined. The effects on the stator current spectrum are described and related frequencies are also determined. This is an important result in the formulation of a fault detection scheme that monitors the stator currents. We utilized the FFT, Wavelet analysis and averaging signal pattern by inner product tool to analyze stator current components. The test results clearly illustrate that the stator signature can be used to identify the presence of a bearing fault.

  • PDF

대전력 3상 유도전동기의 고정자권선을 이용한 전압원 인버터의 병렬운전 (Parallel Operation of Voltage Source Inverters by Using Stator Windings of High Power Three-Phase Induction Motors)

  • 김인동;노의철;전성즙
    • 한국정보통신학회논문지
    • /
    • 제8권4호
    • /
    • pp.815-820
    • /
    • 2004
  • 본 논문에서는 고압 대전력 3상 유도전동기의 고정자 권선을 이용한 전압원 인버터의 병렬운전 방식을 제안한다. 현재 사용되고 있는 대부분의 4극 이상 대전력 유도전동기는 각 상의 권선이 외부에서 접근이 가능하도록 외부단자가 설치되어 있으며, 이들 외부 단자를 이용하여 복수대의 전압원 인버터를 병렬운전 하여 대전력 유도전동기를 구동할 수 있다. 이와 같이 고압 대전력 유도전동기를 복수 개의 전압원 인버터를 병렬 운전하여 구동할 경우, 특정 인버터의 고장발생 시 비록 구동 토오크는 감소될지라도, 나머지 인버터로 시스템을 계속 구동할 수 있어 시스템의 고장대처능력을 향상시킬 수 있다. 또한 병렬 운전되고 있는 각 인버터의 스위칭 동작에 대해 서로 위상차를 갖게 함으로서, 등가 스위칭 주파수를 증가시켜 출력 토오크 리플 감소와 입력 전류 리플 감소, DC Link 커패시터의 크기 감소와 같은 좋은 특성을 얻을 수 있다. 또한 각 인버터로의 전력의 분산에 의해 시스템에서 발생하는 EMI영향을 감소시킬 수 있다. 본 논문에서는 제안한 방식을 컴퓨터 시뮬레이션을 통해 특성을 증명하였다.

가변주파수에 있어서 유도전동기특성의 도시산정법에 관한 연구 (A Study Of The Current-Diagram Method For Calculating Induction Motor Characteristics With Adjustable Frequency)

  • 박민호
    • 전기의세계
    • /
    • 제18권4호
    • /
    • pp.22-30
    • /
    • 1969
  • The development of the frequency convertors using semiconductors devices makes it possible to control the speed of A.C. motors easily. It is now economically feasible to provide them with power at adjustble frequency using silicon-controlled rectifier (or thyristor) inverters. In such a case, in order to operate an induction motor efficiently over a wide speed range, it must be supplied from a variable frecuency source of which frequency is adjustable over the speep range of the motor. It is desired to observe the changes in characteristics as primary current, torque-speed of induction moter etc. at any optional frequncy. Although the charactheristies can be obtained by means of the conventional methods they require very complicated precedures of calcuations. The Current Diagram Method in this paper suggests a new approach to simpler calcuations of the characteristics, using the motor constants at reference frequency. The conclusions of this study are summarized as follows: (1) The equations of stator current at adjusted frequency were derived to construct graphical chart and the current circle required for the Current Diagrm Method. (2) The radius, center of the current circle and the vector locus, the basis for calculating the characteristics, at any desired frequency could be easily determined with the aid of both the derived graphical chart and current circle at reference frequency. (3) The method was shown to be applicable to the various types of 3-phase induction motors and also dealt with its application to the split-phase, condenser motors.

  • PDF

A DTC Stator Flux Algorithm for the Performance Improvement of Induction Traction Motors

  • Van-Tien, Pham;Zheng, Trillion Q.;Yang, Zhong-ping;Lin, Fei;Do, Viet-dung
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.572-583
    • /
    • 2016
  • In view of the speed control characteristics of induction traction motors and the problems of direct torque control (DTC) algorithms in current applications, this paper presents a DTC algorithm characterized by a symmetrical polygon flux control and a closed loop power control in the constant-torque base speed region and constant-power field-weakening region of induction traction motors. This algorithm only needs to add a stator flux control algorithm to the traditional DTC structures. This has the benefit of simplicity, while maintaining the features of traditional algorithms such as a rapid dynamic response, uncomplicated control circuit, reduced dependence on motor parameters, etc. In addition, it obtains a smoother flux trajectory that is conducive to improvement of the harmonic elimination capability, the switching frequency utilization as well as the torque and power performance in the field-weakening region. The effectiveness and feasibility of this DTC algorithm are demonstrated by both theoretical analysis and experimental results.

가변주파수에 있어서 유도잔동기특성의 도식산정법에 관한 연구 제3보 (A Study of the Current-Diagram Method for Calculating Induction Motor Characteristics with Adjustable Frequency)

  • 박민호
    • 전기의세계
    • /
    • 제18권5호
    • /
    • pp.20-25
    • /
    • 1969
  • The development of the frequency convertors using semiconductors devices makes it possible to control the speed of A.C. motors easily. It is now economically feasible to provide them with power at adjustable frequency using silicon-controlled rectifier (or thyristor) inverters. In such a case, in order to operate an induction motor efficiently over a wide speed range, it must be supplied from a variable frequency source of which frequency is adjustable over the speed range of the motor. It is desired to observe the changes in characteristics as primary current, torque-speed of induction motor etc. at any optional frequency. Although the characteristics can be obtained by means of the conventional methods, they require very complicated precedures of calculations. The Current Diagram Method in this paper suggests a new approach to simpler calculations of the characteristics, using the motor constants at reference frequency. The conclusions of this study are summarized as follows: 1) The equations of stator current at adjusted frequency were derived to construct graphical chart and the current circle required for the Current Diagram Method. 2) The radius, center of the current circle and the vector locus, the basis for calculating the characteristics, at any desired frequency could be easily determined with the aid of both the derived graphical chart and current circle at reference frequency. 3) The method was shown to be applicable to the various types of 3-phase induction motors and also dealt with its application to the split-phase, condenser motors.

  • PDF

Parameter Measurement of Induction Motors

  • Kim Kyung-Seo;Byun Sung-Hoon;Na Seung-Ho;Cho Byung-Guk;Kwon Bong-Hyun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.751-755
    • /
    • 2001
  • This paper presents the parameter measurement methods for high performance drive of induction motors. The proposed methods are selected by considering the factors that affect accuracy of measurement. Each method are refined to be adequate for measurement of each motor parameters. Proposed methods are easy to implement and only require inverter-motor system, which are important for practical application.

  • PDF

유도 전동기 파라미터 추정에 관한 연구 (Study on the Parameter Identification for Induction Motors)

  • 김규식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.199-202
    • /
    • 2000
  • The accurate identification of the motor parameters in crucially important to achieve high dynamic performance of induction motors. In this paper parameter auto-tuning algorithms for stator(rotor) resistance stator(rotor) leakage inductance mutual inductance and rotor inertia. Stator(rotor) resistance and stator(rotor) leakage inductance are identified based on the stationary coordinate and mutual inductance and rotor resistor on the scalar speed control and the transient motor terminal voltage. To demonstrate the practical significance of our results we present some experimented results.

  • PDF