• Title/Summary/Keyword: Induced magnetic anisotropy

Search Result 48, Processing Time 0.024 seconds

High Frequency Impedance of Meander Pattern Fabricated by Co-base Amorphous Ribbon (Co계 아몰퍼스리본을 이용하여 제작한 마안더패턴의 고주파 임피던스특성)

  • Shin, Kwang-Ho;Park, Kyung-Il;Geon, Sa-Gong;Song, Jae-Yeon;Kim, Young-Hak
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.4
    • /
    • pp.160-164
    • /
    • 2003
  • The external magnetic field dependency of the impedance, resistance, and inductance of the meander pattern fabricated by using Co-base amorphous ribbon has been investigated in the frequency range of 300 ㎑∼1 ㎓. The amorphous ribbon was patterned to the meander pattern through conventional photolithography and wet etching process. The extremely high sensitivity in impedance changing ratio by external magnetic field was observed. This is due to the transverse magnetic anisotropy the pattern which was induced by magnetic field annealing. The impedance had peak value at the external field of -13 Oe and the impedance changing ratio 100 ${\times}$ (Z$\_$13/-Z$\_$0/)/Z$\_$0/) was about 210% at the frequency of 50 MHz.

Magnetoresistance characteristics of EeN/Co/Cu/Co system spin-valve type multilayer (FeN/Co/Cu/Co계 spin-valve형 다층악의 자기저항 특성)

  • 이한춘;송민석;윤성호;김택기
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.5
    • /
    • pp.210-219
    • /
    • 2000
  • The magnetoresistance characteristics of FeN/Co/Cu/Co and FeN/Co/Cu/Co/Cu/Co/FeN multilayers using ferromagnetic iron-nitrides (FeN) has been studied. The microstructure of FeN film is the mixed ${\alpha}$-Fe and $\varepsilon$-Fe$_3$N phase on the condition that the flow rate of N$_2$ gas is over 0.4 sccm. The magnetoresistance effect is observed because of shape magnetic anisotropy induced by needle-shaped $\varepsilon$-Fe$_3$N phase. This magnetoresistance effect changes, because the degree that the shape magnetic anisotropy adheres to the adjacent Co pinned layer is varied according to the flow rate of N$_2$ gas and the thickness of FeN film. The best magnetoresistance effect is obtained on the condition that the thickness of Co free layer is 70 ${\AA}$ and the maximum MR ratio(%) value of 3.2% shows in the FeN(250 ${\AA}$)/Co(70 ${\AA}$)/Cu(25 ${\AA}$)/Co(70 ${\AA}$)/Cu(25 ${\AA}$)/Co(70 ${\AA}$)/FeN(250 ${\AA}$) mutilayer film which is fabricated at the N, gas flow rate of 0.5 sccm and the FeN film thickness of 250 ${\AA}$. Four steps are observed in the magnetoresistance curve owing to this difference of coercive force, because respective magnetic layers in the multilayer possess different coercive forces. These effects observed in these mutilayer films can be expected to application to the memory device the same MRAM as can carry out simultaneously four signals.

  • PDF

Relationship between Sputtering Pressure of Underlayer and M-H Behavior in Co/Pd and Co/Pt Perpendicular Magnetic Recording Media (Co/Pd 및 Co/Pt 수직자가기기록매체에 있어서 바닥층의 스퍼터링 압력과 M-H 거동의 관계)

  • 오훈상;이병일;주승기
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.4
    • /
    • pp.235-241
    • /
    • 1996
  • Co/Pd and Co/Pt multilayered thin films for perpendicular magnetic recording media were fabricated by sput¬tering method and the effects of the sputtering pressure during the formation of Pd or Pt underlayers on the magnetization behavior and coercivity of the multilayers were investigated. It was found that the coercivity of Co/Pd multilayers was strongly dependent on the sputtering pressure of underlayer and could be enhanced to a large extent merely by increasing the sputtering pressure of underlayer, while in case of Co/Pt films, the degree of coercivity enhancement by controlling the sputtering pressure of underlayer was almost negligible. Coercivity variation of Co/Pd and Co/Pt multilayers with the underlayer material and deposition pressure of underlayer could be well explained in terms of the interface roughness of multilayer films induced by underlayer topology, which could also be correlated to the change of perpendicular anisotropy energy and magnetic reversal feature with the sputtering pressure of underlayer. Kerr rotation angle was hardly affected by the preparation conditions of underlayers.

  • PDF

Increased white matter diffusivity associated with phantom limb pain

  • Seo, Cheong Hoon;Park, Chang-hyun;Jung, Myung Hun;Baek, Seungki;Song, Jimin;Cha, Eunsil;Ohn, Suk Hoon
    • The Korean Journal of Pain
    • /
    • v.32 no.4
    • /
    • pp.271-279
    • /
    • 2019
  • Background: We utilized diffusion tensor imaging (DTI) to evaluate the cerebral white matter changes that are associated with phantom limb pain in patients with unilateral arm amputation. It was anticipated that this would complement previous research in which we had shown that changes in cerebral blood volume were associated with the cerebral pain network. Methods: Ten patients with phantom limb pain due to unilateral arm amputation and sixteen healthy age-matched controls were enrolled. The intensity of phantom limb pain was measured by the visual analogue scale (VAS) and depressive mood was assessed by the Hamilton depression rating scale. Diffusion tensor-derived parameters, including fractional anisotropy, mean diffusivity, axial diffusivity (AD), and radial diffusivity (RD), were computed from the DTI. Results: Compared with controls, the cases had alterations in the cerebral white matter as a consequence of phantom limb pain, manifesting a higher AD of white matter in both hemispheres symmetrically after adjusting for individual depressive moods. In addition, there were associations between the RD of white matter and VAS scores primarily in the hemispheres related to the missing hand and in the corpus callosum. Conclusions: The phantom limb pain after unilateral arm amputation induced plasticity in the white matter. We conclude that loss of white matter integrity, particularly in the hemisphere connected with the missing hand, is significantly correlated with phantom limb pain.

Laplacian-Regularized Mean Apparent Propagator-MRI in Evaluating Corticospinal Tract Injury in Patients with Brain Glioma

  • Rifeng Jiang;Shaofan Jiang;Shiwei Song;Xiaoqiang Wei;Kaiji Deng;Zhongshuai Zhang;Yunjing Xue
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.759-769
    • /
    • 2021
  • Objective: To evaluate the application of laplacian-regularized mean apparent propagator (MAPL)-MRI to brain glioma-induced corticospinal tract (CST) injury. Materials and Methods: This study included 20 patients with glioma adjacent to the CST pathway who had undergone structural and diffusion MRI. The entire CSTs of the affected and healthy sides were reconstructed, and the peritumoral CSTs were manually segmented. The morphological characteristics of the CST (track number, average length, volume, displacement of the affected CST) were examined and the diffusion parameter values, including fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), radial diffusivity (RD), mean squared displacement (MSD), q-space inverse variance (QIV), return-to-origin probability (RTOP), return-to-axis probabilities (RTAP), and return-to-plane probabilities (RTPP) along the entire and peritumoral CSTs, were calculated. The entire and peritumoral CST characteristics of the affected and healthy sides as well as those relative CST characteristics of the patients with motor weakness and normal motor function were compared. Results: The track number, volume, MD, RD, MSD, QIV, RTAP, RTOP, and RTPP of the entire and peritumoral CSTs changed significantly for the affected side, whereas the AD and FA changed significantly only in the peritumoral CST (p < 0.05). In patients with motor weakness, the relative MSD of the entire CST, QIV of the entire and peritumoral CSTs, and the AD, MD, RD of the peritumoral CST were significantly higher, whereas the RTPP of the entire and peritumoral CSTs and the RTOP of the peritumoral CST were significantly lower than those in patients with normal motor function (p < 0.05 for all). In contrast, no significant changes were found in the CST morphological characteristics, FA, or RTAP (p > 0.05 for all). Conclusion: MAPL-MRI is an effective approach for evaluating microstructural changes after CST injury. Its sensitivity may improve when using the peritumoral CST features.

Mossbauer Studies of the $H_2$ Reduction Effects On Magnetic Properties of Sr-Ba Substituted Hexgonal Ferrite (치환형 Sr-Ba 육방 페라이트들의 자기적 성질에 수소환원이 미치는 효과에 관한 Mossbauer 분광학적 연구)

  • 박재윤;권명회;이재광
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.1
    • /
    • pp.35-40
    • /
    • 1999
  • Sr substituted materials for some barium in M-type barium ferrite powder and Co-Ti substituted Sr-Ba hexagonal ferrite powder were prepared by citrate sol-gel method and 2 MOE sol-gel method these hexaferrite particles were reduced for 1hr in the hydrogen gas. The reduction temperatures were varied in the range of 250 $^{\circ}C$ to 500 $^{\circ}C$. X-ray diffraction patterns were measured using diffractometer with Cu $K_{\Alhpa}$ radiation. Mossbauer absorption spectra were measured with a constant acceleration spectrometer. We have focused on studying the origin of increasing $M_s$ by M$\"{o}$ssbauer spectroscopy. Ferrite particles which were sintered at 105$0^{\circ}C$ were found to be typical magnetoplumbite structure and single phase. XRD patterns with varying the reduction temperatures in $Sr_{0.5}Ba_{0.5}Fe_{10}O_{19}$ indicates ferrites particles become composite hexaferrites containing $\alpha$-Fe at T_{red}=350 \;$^{\circ}C$$. On the otherhand, it was found that $Co^{2+}$ ions and $Ti^{4+}$ ions in $Sr_{0.7}Ba_{0.3}Fe_{10}CoTiO_{19}$ prevent from changing $Fe^{3+}$ ions to $\alpha$-Fe during the $H_2$ reduction. Comparing Mossbauer results with XRD results, we have determined most of $\alpha$-Fe are reduced from $4f_{vi}$ sites and 12k sites of $Fe^{3+}$ ions. These $\alpha$-Fe phase bring the induced anisotropy and increase saturation magnetization $M_s$.TEX>.

  • PDF

Independent Verification Program for High-Dose-Rate Brachytherapy Treatment Plans (고선량률 근접치료계획의 정도보증 프로그램)

  • Han Youngyih;Chu Sung Sil;Huh Seung Jae;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.238-244
    • /
    • 2003
  • Purpose: The Planning of High-Dose-Rate (HDR) brachytherapy treatments are becoming individualized and more dependent on the treatment planning system. Therefore, computer software has been developed to perform independent point dose calculations with the integration of an isodose distribution curve display into the patient anatomy images. Meterials and Methods: As primary input data, the program takes patients'planning data including the source dwell positions, dwell times and the doses at reference points, computed by an HDR treatment planning system (TPS). Dosimetric calculations were peformed in a $10\times12\times10\;Cm^3$ grid space using the Interstitial Collaborative Working Group (ICWG) formalism and an anisotropy table for the HDR Iridium-192 source. The computed doses at the reference points were automatically compared with the relevant results of the TPS. The MR and simulation film images were then imported and the isodose distributions on the axial, sagittal and coronal planes intersecting the point selected by a user were superimposed on the imported images and then displayed. The accuracy of the software was tested in three benchmark plans peformed by Gamma-Med 12i TPS (MDS Nordion, Germany). Nine patients'plans generated by Plato (Nucletron Corporation, The Netherlands) were verified by the developed software. Results: The absolute doses computed by the developed software agreed with the commercial TPS results within an accuracy of $2.8\%$ in the benchmark plans. The isodose distribution plots showed excellent agreements with the exception of the tip legion of the source's longitudinal axis where a slight deviation was observed. In clinical plans, the secondary dose calculations had, on average, about a $3.4\%$ deviation from the TPS plans. Conclusion: The accurate validation of complicate treatment plans is possible with the developed software and the qualify of the HDR treatment plan can be improved with the isodose display integrated into the patient anatomy information.