• 제목/요약/키워드: Induce power

검색결과 340건 처리시간 0.031초

권선단락 유형별 동기발전기의 공극자속 파형 분석 (Analysis on Air-Gap Magnetic Flux of Synchronous Generator According to Short-Circuit Types in Winding)

  • 배덕권;김동훈;박중신;이동영;이성일
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.929-935
    • /
    • 2009
  • As modem industrialized society progresses, the demand for electric power is increasing rapidly. The electric power system is getting amazingly bigger and complicated, which can easily induce serious troubles from the potential of large fault problems and/or system failure. The monitoring and diagnosis of the electric machine for the fault detection and protection has been important part in the electric power system. Most faults in the generator appear in the winding. This paper presents the air-gap magnetic flux characteristic of a small-scale 2-pole synchronous generator according to the faults in the field winding to protect the generator from the fault. The magnetic flux patterns in air-gap of a generator under various fault conditions as well as a normal state are simulated by using finite element method. These results are successfully applied to the detection and diagnosis of the short-circuit condition in rotor windings of a high capacitor generator.

HFCT를 활용한 고전압직류송전 케이블 부분방전 위치추정 (Detection and localization of partial discharge in high-voltage direct current cables using a high-frequency current transformer)

  • 홍선민;손우영;천혜원;강대경;박종후
    • 센서학회지
    • /
    • 제30권2호
    • /
    • pp.105-108
    • /
    • 2021
  • Detection and localization of partial discharge are considered critical techniques for estimating the lifetimes of power cables. High-frequency current transformers (HFCTs) are commonly used for the detection of partial discharge in high-voltage alternating current (HVAC) power cables; however, their applicability is compromised by the limitations of the installation locations. HFCTs are typically installed in cable terminals or insulation joint boxes because HVACs induce strong time-varying magnetic fields around the cables, saturating the ferromagnetic materials in the HFCTs. Therefore, partial discharges near the installation locations can be detected. In this study, the feasibility of partial discharge detection using a HFCT was investigated for high-voltage direct current (HVDC) cables. We demonstrated that the HFCT could be installed at any location in the HVDC power cable to monitor partial discharge along the entire cable length. Furthermore, we showed that the HFCT could detect the location of partial discharge with high accuracy.

경전선 복선전철 및 부산신항 노반건설공사 중 PDT말뚝 적용성 연구 (A Study of Applicability of PDT(Pulse Discharge Technology) Pile to Kyung-Geon Rail Road and the bedding Construction of a new port in Busan)

  • 허억준;박재명;윤수동;김태훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1203-1208
    • /
    • 2007
  • In the past decades, complain about ground vibration and noise induced by pile driving has been quickly increased. Because of that, auger drilled piling methods have frequently used specially in urban area. However, the present auger drilled piling methods induce inevitable ground disturbance as well as a certain degree of vibration and noise due to the final hammering. For these reasons, a new auger drilled piling method is required to be developed. This paper introduces PDT(Pulse Discharge Technology) piling method and presents the characteristics of bearing capacity. The PDT piling method is to install in-situ piles using electric power so called Pulse. The pile installed by PDT appears to be able to develop shaft and end bearing capacity efficiently. This paper introduces PDT(Pulse Discharge Technology) piling method, which is the 512nd new construction technology. The PDT piling method is to install in-situ piles using electrical power so called Pulse power. The pulse power is physical value that indicates the energy change per unit time(dE/dt). Since the pulse power is to push ground, using the pulse power is enable a hole to be expanded as well as the ground to be improved by compaction. Therefore, The pile installed by PDT appears to be able to develop shaft and end bearing capacity efficiently. In this study, couples of pile loading tests were carried out to figure out whether or not the PDT piling method is applicable to constructions like rail road facility. As a result, it was concluded that the PDT piling technique meet the requirements for such a rail road related construction.

  • PDF

Enrichment of $CO_2$-Fixing Bacteria in Cylinder-Type Electrochemical Bioreactor with Built-In Anode Compartment

  • Jeon, Bo-Young;Jung, Il-Lae;Park, Doo-Hyun
    • Journal of Microbiology and Biotechnology
    • /
    • 제21권6호
    • /
    • pp.590-598
    • /
    • 2011
  • Bacterial assimilation of $CO_2$ into stable biomolecules using electrochemical reducing power may be an effective method to reduce atmospheric $CO_2$ without fossil fuel combustion. For the enrichment of the $CO_2$-fixing bacteria using electrochemical reducing power as an energy source, a cylinder-type electrochemical bioreactor with a built-in anode compartment was developed. A graphite felt cathode modified with neutral red (NR-graphite cathode) was used as a solid electron mediator to induce bacterial cells to fix $CO_2$ using electrochemical reducing power. Bacterial $CO_2$ consumption was calculated based on the variation in the ratio of $CO_2$ to $N_2$ in the gas reservoir. $CO_2$ consumed by the bacteria grown in the electrochemical bioreactor (2,000 ml) reached a maximum of approximately 1,500 ml per week. Time-coursed variations in the bacterial community grown with the electrochemical reducing power and $CO_2$ in the mineral-based medium were analyzed via temperature gradient gel electrophoresis (TGGE) of the 16S rDNA variable region. Some of the bacterial community constituents noted at the initial time disappeared completely, but some of them observed as DNA signs at the initial time were clearly enriched in the electrochemical bioreactor during 24 weeks of incubation. Finally, Alcaligenes sp. and Achromobacter sp., which are capable of autotrophically fixing $CO_2$, were enriched to major constituents of the bacterial community in the electrochemical bioreactor.

A Study on Winter Season Measurement Results to cope with Dynamic Pricing for the VRF System

  • Kim, Hwan-yong;Kim, Min-seok;Lee, Je-hyeon;Song, Young-hak
    • Architectural research
    • /
    • 제17권3호
    • /
    • pp.109-115
    • /
    • 2015
  • The dynamic pricing of electricity, where the electricity rate increases in a time zone with a high demand for electricity is typically applied to a building whose power reception capacity is greater than a certain size. This includes the time of use(TOU) electricity pricing in Korea which can induce the effect of reducing the power demand of a building. Meanwhile, a VRF (Variable Refrigerant Flow) system that uses electricity is regarded as one of the typical heating and cooling systems along with central air conditioning (central HVAC) for its easy operation and application to the building. Thus, to reduce power energy and operating costs of a building in which the TOU and VRF systems are applied simultaneously, we suggested a control for changing the indoor temperature setting within the thermal comfort range or limiting the rotational speed of an inverter compressor. In this study, to describe the features of the above-mentioned control and verify its effects, we evaluated the results obtained from the analysis of its operation data. Through the actual measurements in winter operations for 73 days since mid- December 2014, we confirmed a reduction of 10.9% in power energy consumption and 12.2% in operating costs by the new control. Also, a reduction of 13.3% in power energy consumption was identified through a regression analysis.

대용량 무선전력전송 환경 유도현상 감쇄를 위한 차폐 특성 분석 (Analysis of Shielding Characteristics for Induction Phenomenon Attenuation of Large Capacity Wireless Power Transmission Environment)

  • 채동주;김영석;정진수;임현성;조성구;홍성준
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1844-1851
    • /
    • 2017
  • As the capacity of the wireless power transmission increases, a higher supply current which may induce current in nearby conductive parts requires. Induced current may affect electric shock to the human body and malfunction of the electrical equipment. In order to prevent such induced phenomena as a risk factor, shielding is required between the source of the wireless power transmission and the conductive parts. The resonance frequency for the large capacity wireless power transmission has the wavelength of several hundred meters, so most environments are included in the near-field area. By wave impedance, the electric field has higher density in the near-field area and needs to be analyze for protecting. For this purpose, it is necessary to select a substance having a larger electric conductivity and optimized shielding structure. In this paper, an aluminum base shielding structure was presented to conduct experiments on thickness, position, and heat dissipation. In the 35 kW, 60 kHz environments, the optimized 5T Al base shielding structure attenuates the induced current to 43 %.

Analytical and experimental investigation of stepped piezoelectric energy harvester

  • Deepesh, Upadrashta;Li, Xiangyang;Yang, Yaowen
    • Smart Structures and Systems
    • /
    • 제26권6호
    • /
    • pp.681-692
    • /
    • 2020
  • Conventional Piezoelectric Energy Harvesters (CPEH) have been extensively studied for maximizing their electrical output through material selection, geometric and structural optimization, and adoption of efficient interface circuits. In this paper, the performance of Stepped Piezoelectric Energy Harvester (SPEH) under harmonic base excitation is studied analytically, numerically and experimentally. The motivation is to compare the energy harvesting performance of CPEH and SPEHs with the same characteristics (resonant frequency). The results of this study challenge the notion of achieving higher voltage and power output through incorporation of geometric discontinuities such as step sections in the harvester beams. A CPEH consists of substrate material with a patch of piezoelectric material bonded over it and a tip mass at the free end to tune the resonant frequency. A SPEH is designed by introducing a step section near the root of substrate beam to induce higher dynamic strain for maximizing the electrical output. The incorporation of step section reduces the stiffness and consequently, a lower tip mass is used with SPEH to match the resonant frequency to that of CPEH. Moreover, the electromechanical coupling coefficient, forcing function and damping are significantly influenced because of the inclusion of step section, which consequently affects harvester's output. Three different configurations of SPEHs characterized by the same resonant frequency as that of CPEH are designed and analyzed using linear electromechanical model and their performances are compared. The variation of strain on the harvester beams is obtained using finite element analysis. The prototypes of CPEH and SPEHs are fabricated and experimentally tested. It is shown that the power output from SPEHs is lower than the CPEH. When the prototypes with resonant frequencies in the range of 56-56.5 Hz are tested at 1 m/s2, three SPEHs generate power output of 482 μW, 424 μW and 228 μW when compared with 674 μW from CPEH. It is concluded that the advantage of increasing dynamic strain using step section is negated by increase in damping and decrease in forcing function. However, SPEHs show slightly better performance in terms of specific power and thus making them suitable for practical scenarios where the ratio of power to system mass is critical.

보험사기범죄에 대한 분석 고의 교통사고 유도 - 합의금 요구 사건을 중심으로 (An Analysis of Insurance Crimes: The Case of Blackmail in Automobile Accidents)

  • 양채열
    • 재무관리연구
    • /
    • 제23권1호
    • /
    • pp.227-242
    • /
    • 2006
  • 이 논문은 자동차보험분야에서 고의사고를 통한 보험사기에 대한 게임이론적 분석을 통하여 개선안을 제시한다. 보험사기범이 고의로 교통사고를 유발하여 보험금과 합의금을 받아내는 상황을 게임모형으로 분석한다. 현행제도 하에서는 최초 교통법규를 위반하여 사고를 낸 운전자(즉 궁극적인 보험사기의 피해자)의 교통법규 위반행위에 대한 처벌수준이 너무 높아서 최초법규위반자와 보험사기범과의 협상게임에서 협상력이 과도하게 약화된다. 보험사기범은 이를 악용하여 과도한 합의금을 (협박하여) 요구하게 되는 것이다. 즉, 최초 법규위반 운전자에 대한 과다한 처벌이, 본래 목적이 교통질서를 유지하려는 것임에도 불구하고, 오히려 보험사기범죄를 유발하는 역효과를 발생시키고 있는 것이다. 이러한 보험사기에 대한 대책으로 보통 제시되는 방안은 범죄에 대한 적발확률을 높이고 적발시 처벌강도를 높여서 보험사기범에 대한 기대처벌비용을 높이자는 것이다. 이러한 제안에 추가하여 이 논문에서 보이려는 것은, 보험사기범과 사기피해자(최초 법규위반/사고원인 제공자)의 게임상황에서 사기 피해자의 협상력을 낮추지 않는(즉 올리는) 것이 보험사기를 억제하는 데에 보다 더 중요하다는 점이다. 보험사기를 억제하기 위해서는 보험사기범에 대한 공권력 등을 사용한 적발 처벌도 중요하지만, 그와 병행하여 사기 피해자의 협상력을 높이는 것이 중요하다. 중요 교통법규위반 중 선량한 운전자가 어쩔 수 없이 위반하게 되는 법규위반 행위에 대한 처벌을 적절한 수준으로 낮추는 것이 고의사고를 유발하는 보험사기 범죄를 줄이는 방안이 될 것이다.

  • PDF

와전류를 이용한 에너지 포집의 개념과 모델 (Concept and Model of Energy Harvesting using Eddy Current)

  • 한지훈;박성근;주광일;임승현;오일권
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3506-3511
    • /
    • 2007
  • The energy harvesting using smart materials has been extensively investigated to supply electric power to wireless sensor systems. In this paper, the energy harvesting using eddy current was studied with the integrated magnetic cantilever beam system. If a large conductive metal plate moves through a magnetic field which intersects perpendicularly to the sheet, the magnetic field will induce small rings of current which will actually create internal magnetic fields opposing the change. This eddy current that was induced in the coiled conductive sheet from the mechanical vibration was converted to chemical energy by charging batteries. The experimental results show that the eddy current generated the electric power up to max 31.2mW. Additionally the vibration reduction of the mechanical cantilever beam was observed by the energy dissipation in the electro-magnetic coupled system. The present result shows that the vibration level of the first natural frequency was reduced up to 7.7dB

  • PDF

고출력 $CO_2$레이저 용접에서 키홀의 불안정으로 발생한 기공의 절감방법 (Reduction Method of Porosity Formed by Instability of Keyhole in High Power $CO_2$ Laser Welding)

  • 김정일;조민현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권4호
    • /
    • pp.464-471
    • /
    • 2002
  • Porosity formation in partial penetration welds by high power lasers is a serious problem in industry. There are two main causes that induce porosity formation. One form of porosity is due to gases (e.g. hydrogen, oxygen) dissolving into the weld pool because of the high temperature and then the rapid solidification traps gases as a bubble in the weld metal. The second problem is voids formed by the keyhole collapsing due to unstable keyhole fluid dynamics. The voids that form at the bottom of the keyhole are relatively large and irregular in shape compared to the gas bubbles; this void formation is the primary concern in this paper. The reduction of voids formed by keyhole collapse is achieved by improving the stability of keyhole. Two methods to improve keyhole stability are discussed in this paper: pulse modulation and beam incident angle. Pulse modulation of the laser beam was performed between 100 Hz and 500 Hz to find out the optimum frequency for the keyhole dynamics. The incident beam angle changed the impact angle of the laser beam to the work surface in a range of 0 to 25 degrees. Glycerin in a semi-solidified state is used as a medium for performing the welding because its transparency allows of visualization of the keyhole.