• Title/Summary/Keyword: Induce power

Search Result 338, Processing Time 0.026 seconds

A Study of a Voltage Sag Compensation Scheme on Loads by Using Flywheel Energy Storage system (플라이휠을 이용한 부하에의 순시전압강하 보상 방안 연구)

  • Lee, Han-Sang;Jang, Gil-Soo;Han, Sang-Cheul;Sung, Tae-Hyun;Han, Young-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.321-322
    • /
    • 2006
  • Faults on power systems are inevitable phenomena. These faults can be classified by two categories, temporary and permanent faults. Without distinction of fault types, the faults would induce several changes on power system such as transmission line trip. Especially, the most common phenomena which loads experience by the power system fault is voltage sag. Voltage sags mean that the bus voltage maintains under 0.9 p.u. of rating for several cycles, and they give serious effects to operation of load devices. To ensure proper operation of the load, the flywheel systems, one of the energy storage system, are suggested in this paper. This paper demonstrates the efficiency of flywheel energy storage system against voltage sag by PSCAD/EMTDC simulation.

  • PDF

White LED Local Dimming Backlight for Aggressive Power Saving and Artifact Minimizing

  • Yeo, Dong-Min;Kwon, Yong-Hoon;Kang, Eui-Jeong;Park, Se-Ki;Yang, Byung-Choon;Kim, Gi-Cherl;Jang, Tae-Seok
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1156-1159
    • /
    • 2008
  • Local dimming driving has advantages in reducing power consumption and improving contrast ratio(CR). In an LED backlight unit(BLU), many small LED blocks are implemented in 2-dimmensional space, and luminance of the blocks is controlled by a local dimming algorithm. However, such a BLU can induce various recognizable artifacts. A new novel algorithm is proposed for exact block luminance calculation to correct local dimming artifacts. Also we discuss modified low-gray-level dimming to achieve much aggressive power saving in a local dimming BLU system.

  • PDF

Noise Reduction of PDP Module (PDP 모듈의 소음 저감)

  • Park, Sooyong;Lee, Seokyeong;Jaeman Joo;Junghun Kang;Sangkyoung O
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.326.2-326
    • /
    • 2002
  • A PDP(Plasma Display Panel) module consists of a discharge panel, a SMPS for power supply, driving boards for panel control, and a logic board. Driving boards supply high voltage pulses to induce glow dischargein the PDP panel. The electrical pulses excite the circuit elements and subsequentlyacoustic noises. The main sources of the noise in the circuit are the transformer of SMPS and the power MOSFET of driving boards, and the heat sinks often amplify the noise level. (omitted)

  • PDF

Calculation of Power Frequency Electromagnetic Field Around the Kyeongbu High Speed Railways (경부고속철도 주변의 60 Hz 전자계 분포 예측에 관한 연구경부고속철도)

  • Kim, E.S.;Myung, S.H.;Lee, B.Y.;Han, I.S.;Park, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1648-1650
    • /
    • 1997
  • The effects of power frequency electric and magnetic fields have been a source of concern for many years. Electromagnetic fields can pose a theat to both signal system of electrified railways and human body around railways. It is believed that, though the electromagnetic fields do no serious harm to human health, they do induce biological effects. This paper estimates the electromagnetic fields near Kyeongbu high speed railways with numerical data. The charge simulation method and surface charge method are used to calculate the electric field of 2 dimensional power distribution lines and rails and magnetic field is calculated on the base of Biot-Sarart's law.

  • PDF

Modeling of a Transfer Function for Frequency Controlled Resonant Inverters

  • Han, Mu-Ho;Lee, Chi-Hwan;Kwon, Woo-Hyun
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.567-574
    • /
    • 2009
  • A linear transfer function for the output current control of frequency-controlled resonant inverters is proposed in this paper. The circuit of resonant inverters can be transformed into two coupled circuits through the complex phasor transform. The circuits consist of cross-coupled power sources and passive elements. The circuits are used to induce the state space equation, which is transformed into the $4^{th}$ order cross-coupled transfer function. The $4^{th}$ order cross-coupled transfer function is modeled into a $2^{nd}$ order linear transfer function based on a behavior analysis of the pole and zero locations that facilitate a simple and intuitive linear transfer function. The feasibility and validity of the proposed linear transfer function were verified by simulation and experiment.

Analysis and optimization of Wiel-Dobke synthetic testing circuit parameters (Weil-Dobke 합성단락 시험회로의 Parameter 분석과 최적화)

  • Kim, Maeng-Hyun;Rhyou, Hyeong-Kee;Park, Jong-Wha;Koh, Hee-Seog
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.623-627
    • /
    • 1995
  • This paper describes analysis and optimization of Weil-Dobke synthetic testing circuit parameters, which is efficient and economical test method in high capacity AC circuit breaker. In this paper, analysis of synthetic short-circuit test circuit parameter proposed nondimensional factor that is reciprocal comparison value of circuit parameter and is not related to rated of circuit breaker, in particular, this study induce minimization of required energy of critical TRV generation specified in IEC 56 standards and present optimal design of synthetic short circuit testing facilities.

  • PDF

Harmfulness of infrasound and wind turbine noise managements (초저주파음의 유해성 및 풍력 발전 소음 관리에 대한 고찰)

  • Kim, Seong-Chan;Choi, Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.1
    • /
    • pp.73-83
    • /
    • 2021
  • Wind power energy harvesting has a big potential as a future clean energy resource, but accompanies infrasonic noises. The infrasound is difficult to shield and can induce various negative physiological effects. In this study, the Wind Turbine Syndrome (WTS) caused by the infrasonic noises are introduced, and the technical aspects for the measurement and management of the infrasonic noises from wind power plants are discussed.

Analysis of the Likelihood of Internal Radiation Exposure When Decommissioning a Nuclear Power Plant in Korea

  • Jiung Kim;Tae Young Kong;Seongjun Kim;Jinho Son;Changju Song;Jaeok Park;Seungho Jo;Hee Geun Kim
    • Journal of Radiation Industry
    • /
    • v.18 no.2
    • /
    • pp.141-145
    • /
    • 2024
  • In Publication No. 66 of the International Commission on Radiological Protection, an activity median aerodynamic diameter (AMAD) of 5 ㎛ is considered in internal exposure dose assessment owing to inhalation of radionuclides in a workplace. However, analysis of aerosols generated during dismantling experiments, such as in the oxy-cutting of a reactor vessel conducted in Korea, revealed that the radioactive aerosols have AMAD ranging from 0.024 to 0.064 ㎛. Such extremely fine aerosols can induce internal exposure if inhaled. In particular, alpha radionuclides in aerosols can lead to significantly higher levels of radiation exposure than beta and gamma radionuclides, thus highlighting the need to establish appropriate internal exposure radiation protection programs and monitoring systems that specifically address alpha radionuclides when decommissioning nuclear power plants in Korea.

Power based Routing Scheme for wireless sensor networks (무선 센서네트워크에서의 전력기반 라우팅기법)

  • Ernest, Mugisha;Lee, Geun-Soo;Kim, Namho;Yu, Yun-Seop;Park, Hyung-Kun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.657-658
    • /
    • 2015
  • In an wireless sensor network, energy efficient routing protocol is important for multi-hop transmission because senor nodes are powered by battery. In multi-hop transmission, specifice nodes are used and the battery power becomes low, it induce the asymetric remaining power among the nodes and makes the network lifetime reduced. In this paper, we propose a power-aware routing protocol which determines the routing path considering the remaining power of the nodes. Simulation results shows that the proposed routing scheme minimize the transmission delay and increase the network lifetime.

  • PDF

PRE- AND POSTNATAL TOXICITY EVALUATION OF 60 Hz HORIZONTALLY POLARIZED MAGNETIC FIELDS IN RATS

  • Chung, Moon-Koo;Kim, Jong-Choon;Myung, Sung-Ho;Han, Sang-Seop
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2002.05a
    • /
    • pp.133-133
    • /
    • 2002
  • Recently, there is an increasing nationwide concern in Korea that exposure to electric and magnetic fields (MF) in the home environment may not be safe in humans. We previously demonstrated that exposure of MF during the entire period of pregnancy did not induce any adverse effects on both pregnant dams and embryo-fetal development in rats.(omitted)

  • PDF