• Title/Summary/Keyword: Indoor-Unit

Search Result 338, Processing Time 0.026 seconds

Entering behavior and fishing capacity on pot for Octopus minor by mesh size (통발의 그물코 크기 변화에 따른 낙지의 입망 행동과 어획 성능)

  • KWON, Inyeong;KIM, Taeho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.57 no.3
    • /
    • pp.185-193
    • /
    • 2021
  • This study was conducted to evaluate the performance of the octopus pot according to mesh sizes. Entering behavior of Octopus minor and bait (Macrophthalmus japonicus) escape rate on the mesh sizes of the pots were investigated for six times in indoor tank. The sea trials for evaluating the performance of Octopus minor pot to different mesh sizes (22, 20 and 18 mm) were conducted for six times from 2017 to 2018 in the coastal sea of Deukyang Bay, the Republic of Korea. Behavior patterns of contact pot to leaved pot were more frequent than contact pot to bait search. When the octopus contacted to the pot, there was no clear search behavior to distinguish the mesh sizes. Total catch of 46% was accounted for 18 mm pots, followed by 34% at 20 mm and 20% at 22 mm (P < 0.05). Catch per unit effort was calculated as 30 g/pot at 22 mm, 44 g/pot at 20 mm and 59 g/pot at 18 mm. As a result of evaluating 50% selection of mantle length and weight on the mesh sizes, mantle length (mm) and weight (g) were 84.6 and 147.8 in 22 mm, followed by 20 and 18 mm.

Autonomous Transmission Power Adjustment Strategy for Femtocell Base Station

  • Alotaibi, Sultan
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.4
    • /
    • pp.367-373
    • /
    • 2022
  • Femtocells have recently been recognized for their potential to boost network capacity, improve end-user QoS and throughput, and do so at a cheap cost and with ease of implementation. The use of femtocells in indoor environments, such as residential buildings with neighboring homes, is becoming more popular. Femtocells are subject to interference from other femtocells, and the unwanted effects of interference are amplified when femtocells are deployed in close proximity to one another. As a consequence, the network's overall performance is degraded to a significant degree. One of the strategies that is thought to be effective in reducing the impact of interference is altering the transmission power of the femtocells. In this paper, a dynamic downlink transmission power of femtocells is suggested. In accordance with the observed cost function unit, each femtocell automatically changes its transmission power. If a femtocell causes too much interference for its neighbors, its transmission power level will be limited by that interference's rate. A simulation experiment is conducted to validate the effectiveness of the suggested system when compared with other schemes. When compared to previous schemes, which are addressed in this study, the numerical results show that the proposed strategy could provide more capacity while also ideally mitigating the influence of interference among co-channel deployed femtocells.

Design of Dual-band Frequency Selective Surface Applicable to Wi-Fi 6E System (Wi-Fi 6E 시스템에 적용 가능한 이중대역 주파수 선택표면 구조 설계)

  • Yun-Seok Mun;Sung-Sil Cho;Ic-Pyo Hong
    • Journal of IKEEE
    • /
    • v.27 no.1
    • /
    • pp.71-77
    • /
    • 2023
  • In this paper, a dual-band stopband frequency selective surface that can be applied to Wi-Fi 6E systems is designed to block external interfering signals with adjacent operating frequency spectrum in indoor wireless LAN environments. The proposed frequency selective surface structure has frequency blocking characteristics in the 2.4GHz and 6GHz bands, and is realized through a modified crossed dipole structure and an interlocking puzzle form between unit structures. The proposed structure is designed to have stable frequency response characteristics with respect to incident angle and polarization, and the experimental results show good agreement with the simulation results for incident waves from 0° to 45°.

A Study on the Educational Welfare Facilities for Disability-friendly Campus (장애친화적 캠퍼스를 위한 교육복지시설에 관한 연구)

  • Kim, Hak Cheol
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.4
    • /
    • pp.25-32
    • /
    • 2022
  • The purpose of this study is to provide design guidelines necessary for creating disability-friendly campuses. To this end, a literature survey and a survey on the current educational welfare facilities for disabled college students were conducted. The fact-finding survey was conducted in writing and visiting evaluations on 19 campuses located in Gangwon-do(province). The results of this study are summarized as follows: 1) The college enrollment rate of the disabled has doubled since 2000, but it was found to be half of the enrollment rate based on school enrollment, and the number of students who gave up in the middle is increasing. This is due to an obstacle in the learning environment, so it is necessary to improve welfare facilities. 2) As a result of evaluating the status of educational welfare support for students with disabilities, it was found that the overall evaluation result was improved, but the absolute evaluation result was less than 70%, and it was not improved. 3) As a result of evaluating the actual conditions of the intermediate facilities, indoor facilities, sanitary facilities, guidance and other facilities, and unit spaces, it is necessary to expand and improve them due to the lack of disabled parking marks, continuity of access roads, pedestrian safety passages, lifts, and rest areas for the disabled.

Classification of Construction Worker's Activities Towards Collective Sensing for Safety Hazards

  • Yang, Kanghyeok;Ahn, Changbum R.
    • International conference on construction engineering and project management
    • /
    • 2017.10a
    • /
    • pp.80-88
    • /
    • 2017
  • Although hazard identification is one of the most important steps of safety management process, numerous hazards remain unidentified in the construction workplace due to the dynamic environment of the construction site and the lack of available resource for visual inspection. To this end, our previous study proposed the collective sensing approach for safety hazard identification and showed the feasibility of identifying hazards by capturing collective abnormalities in workers' walking patterns. However, workers generally performed different activities during the construction task in the workplace. Thereby, an additional process that can identify the worker's walking activity is necessary to utilize the proposed hazard identification approach in real world settings. In this context, this study investigated the feasibility of identifying walking activities during construction task using Wearable Inertial Measurement Units (WIMU) attached to the worker's ankle. This study simulated the indoor masonry work for data collection and investigated the classification performance with three different machine learning algorithms (i.e., Decision Tree, Neural Network, and Support Vector Machine). The analysis results showed the feasibility of identifying worker's activities including walking activity using an ankle-attached WIMU. Moreover, the finding of this study will help to enhance the performance of activity recognition and hazard identification in construction.

  • PDF

Visual-Inertial Odometry Based on Depth Estimation and Kernel Filtering Strategy (깊이 추정 및 커널 필터링 기반 Visual-Inertial Odometry)

  • Jimin Song;HyungGi Jo;Sang Jun Lee
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.19 no.4
    • /
    • pp.185-193
    • /
    • 2024
  • Visual-inertial odometry (VIO) is a method that leverages sensor data from a camera and an inertial measurement unit (IMU) for state estimation. Whereas conventional VIO has limited capability to estimate scale of translation, the performance of recent approaches has been improved by utilizing depth maps obtained from RGB-D camera, especially in indoor environments. However, the depth map obtained from the RGB-D camera tends to rapidly lose accuracy as the distance increases, and therefore, it is required to develop alternative method to improve the VIO performance in wide environments. In this paper, we argue that leveraging depth map estimated from a deep neural network has benefits to state estimation. To improve the reliability of depth information utilized in VIO algorithm, we propose a kernel-based sampling strategy to filter out depth values with low confidence. The proposed method aims to improve the robustness and accuracy of VIO algorithms by selectively utilizing reliable values of estimated depth maps. Experiments were conducted on real-world custom dataset acquired from underground parking lot environments. Experimental results demonstrate that the proposed method is effective to improve the performance of VIO, exhibiting potential for the use of depth estimation network for state estimation.

Middle Schooler's Perception of the Unit "Housing Education" of the 9th Grade Technology and Home Economics (주생활 영역 학습에 대한 중학생의 인식)

  • Choi, Hyun-Suk;Jang, Sang-Ock
    • Journal of Korean Home Economics Education Association
    • /
    • v.20 no.3
    • /
    • pp.1-16
    • /
    • 2008
  • The purpose of this study is to investigate the perception of middle schooler's lesson of 9th grade "Housing Education" Questionnaire survey was conducted with 394 middle school students in Gyeongnam in 2006 and the dada analyzed by the descriptive statistics, t-test, One-way ANOVA, Duncan's multiple range test, Pearson correlation and multiple regression analysis by using SPSS 14. program. The result of this study were as follows. The unit 'Use of dwelling space' was perceived useful in real life, interesting in explanation & visual materials of the text, taught easily to understand the students and ranked highest in class satisfaction compared with the rest two units. The unit 'Indoor environment & equipment' was least interesting, most difficult and ranked lowest in class satisfaction. The unit 'House management & repair' was relatively interesting and easy, but not useful in real life, not much interesting in explanation & visual materials in text, taught difficult by teachers. The class satisfaction ranked second of the units. Female students perceived that the unit 'Use of dwelling space' was easy, but male students perceived that all the units were interesting in the explanation & visual materials in textbook, various teaching-learning methods, interesting experiment & practice, and was satisfied with the unit 'House management & repair'. As their academic achievement of "Technology & Home Economics" was lower, they perceived that the education contents and various experiment & practice were more difficult. The class satisfaction of middle schoolers about the unit "Housing Education" were affected by how easily the teacher taught the subject, making it more understandable, the level of difficulty of the contents and the level of interest of explanation & visual materials of text.

  • PDF

The Real Scale Fire Test for Fire Safety in Apartment Housing (실물화재실험을 통한 공동주택의 화재안전성 연구)

  • Yoo, Yong-Ho;Kweon, Oh-Sang;Kim, Heung-Youl
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.57-65
    • /
    • 2009
  • This study was intended to conduct a Real-scale fire test to predict the fire behavior by unit space at the apartment building where a huge casualties and injuries are likely. After setting the inflammables inside the house, the test aimed to identify the fire characteristics to each unit item was carried out. The house was divided into 4 unit space such as kitchen, living room, bedroom and a study for a real scale fire test. As a result, bedroom reached to flashover state in 5minutes after setting the fire, indicating a rapid fire growth such as 7433.3kW of maximum thermal emissivity, 578.6ppm of carbon monoxide, 1.25ppm of carbon dioxide and $1,350^{\circ}C$ of maximum indoor temperature. Particularly, the fire growth was made up to critical temperature which might cause a severe damage to the people within 3minutes, if the fire were not extinguished at inflammable space at the early stage of fire, which stressed the need of early response. The result of a real scale fire test could be compared with the outcome of expanded simulation test and used in predicting the fire spread at the space for different use.

A Study on the Verification of an Indoor Test of a Portable Penetration Meter Using the Cone Penetration Test Method (자유낙하 콘관입시험법을 활용한 휴대용 다짐도 측정기의 실내시험을 통한 검증 연구)

  • Park, Geoun Hyun;Yang, An Seung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.2
    • /
    • pp.41-48
    • /
    • 2019
  • Soil compaction is one of the most important activities in the area of civil works, including road construction, airport construction, port construction and backfilling construction of structures. Soil compaction, particularly in road construction, can be categorized into subgrade compaction and roadbed compaction, and is significant work that when done poorly can serve as a factor causing poor construction due to a lack of compaction. Currently, there are many different types of compaction tests, and the plate bearing test and the unit weight of soil test based on the sand cone method are commonly used to measure the degree of compaction, but many other methods are under development as it is difficult to secure economic efficiency. For the purpose of this research, a portable penetration meter called the Free-Fall Penetration Test (FFPT) was developed and manufactured. In this study, a homogeneous sample was obtained from the construction site and soil was classified through a sieve analysis test in order to perform grain size analysis and a specific gravity test for an indoor test. The principle of FFPT is that the penetration needle installed at the tip of an object put into free fall using gravity is used to measure the depth of penetration into the road surface after subgrade or roadbed compaction has been completed; the degree of compaction is obtained through the unit weight of soil test according to the sand cone method and the relationship between the degree of compaction and the depth of the penetration needle is verified. The maximum allowable grain size of soil is 2.36 mm. For $A_1$ compaction, a trend line was developed using the result of the test performed from a drop height of 10 cm, and coefficient of determination of the trend line was $R^2=0.8677$, while for $D_2$ compaction, coefficient of determination of the trend line was $R^2=0.9815$ when testing at a drop height of 20 cm. Free fall test was carried out with the drop height adjusted from 10 cm to 50 cm at increments of 10 cm. This study intends to compare and analyze the correlation between the degree of compaction obtained from the unit weight of soil test based on the sand cone method and the depth of penetration of the penetration needle obtained from the FFPT meter. As such, it is expected that a portable penetration tester will make it easy to test the degree of compaction at many construction sites, and will lead to a reduction in time, equipment, and manpower which are the disadvantages of the current degree of compaction test, ultimately contributing to accurate and simple measurements of the degree of compaction as well as greater economic feasibility.

Effect of the Level of Concentrates and Pasture Grazing on Growth, Reproductive Performance and Feed Efficiency in Spring born Hanwoo Heifers (농후사료 급여수준 및 방목이 춘계분만 한우 암송아지의 성장발육, 번식능력 및 사료이용성에 미치는 효과)

  • Kang, S. W.;Im, S. K.;Jeong, J. W.;Woo, J. S.;Jeon, K. J.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.101-112
    • /
    • 2003
  • This study was conducted to investigate the effect of the level of concentrates and pasture grazing in 60 head of spring born Hanwoo heifers(initial body weight; 125.3kg) for 450days from six to 21 months in age. Feeding trial was conducted with 5 treatment(twelve heads/ treatment) which were T1(1.5% of apparent body weight in concentrates and indoor feeding for over-all period), T2(0.5% of apparent body weight in concentrates for pre-pasture grazing and pasture grazing), T3(1.0% of apparent body weight in concentrates for pre-pasture grazing and pasture grazing), T4(1.5% of apparent body weight in concentrates for pre-pasture grazing and pasture grazing), T5(2.0% of apparent body weight in concentrates for pre-pasture grazing and pasture grazing). During the total experimental period, average daily gains by treatments ranged from 0.322 to 0.465kg(average 0.405kg) and higher in the order of T5, T4, T1, T3 and T2, and increased with the level of concentrates feeding for pre-pasture grazing. TDN intakes required per unit of kilogram gain were 9.13 to 9.79kg(average 9.49kg) higher in the order of T1, T3, T5, T4 and T2, For the grazing period, they were ranged from 12.39 to 12.98kg(average 12.68kg), and were not significantly different. But TDN requirements of grazing groups was higher about 15.6% than the indoor feeding group’s. The rate of roughage to concentrates by treatments were 57.8 to 73.6%(average 63.7%). The body weight of 15 and 21 month in ages, that is, the ages at puberty and first conception by treatments were 201.2 to 230.7kg(average 223.8kg) and 270.2 to 331.4kg (average 307.6kg), respectively, and the latter were high per unit of 20.4kg by increasing the level of concentrates feeding for pre-pasture grazing every 0.5% addition of apparent body weight. The age of 225 and 275kg in body weight, that is, the body weight at puberty and first conception by treatments were 14.0 to 17.6 month (average 15.3 month) and 17.9 to 21.7 month(average 19.4), respectively, and the latter were shorter about 1.3 month by increasing the level of concentrates feeding every 0.5% addition of apparent body weight. According to the above results, it may be concluded that spring born Hanwoo heifers are raised at indoor have to feed with 1.8% of body weight in concentrates under full feeding of rice straws for all period from six to 21 months in age, but with 1.5% of apparent body weight in concentrates for grazing period.