• Title/Summary/Keyword: Indoor water space

Search Result 52, Processing Time 0.028 seconds

A Study on the Change of Indoor Heating Environment with the Creation of Indoor Water Space through a Scale Model (축소모형을 이용한 실내 수공간 도입 효과 연구)

  • Oh, Sang Mok;Oh, Se Gyu
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.67-72
    • /
    • 2010
  • This study was conducted to examine the change of heating environment with the creation of an indoor water space. Living environments and comfort of dwellers can be improved by utilizing the physical properties of water effectively. This study focuses on the basic examination of the effect of water space and the environmental effects of water space by experiment. Two identical models were fabricated to compare the changes in indoor temperature and humidity with and without a water space. With the water space, temperature was reduced by an average of $0.55^{\circ}C$ a day and moisture content increased by an average of 4%. As a result, it was possible to obtain quantitative data on water space's temperature reduction and humidity control capacities. This study is expected to provide basic information for further studies on the effect of water spaces in various buildings.

Analysis of Thermo Environment Change by Introduction of Indoor Water Space (실내 수공간 도입에 따른 온열 환경 변화 분석)

  • Oh, Sang Mok;Oh, Se Gyu
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.53-60
    • /
    • 2012
  • This research is an illustrative research to verify the thermo environmental change created after introduction of indoor pond through abridged model test and simulation analysis. Especially, temperature and comfort level are analyzed by adjusting factors like size of water space, distance length, and location. Summary of the research is as follows. First, the most effective size of water space is 7% of the indoor size, from southern side. Temperature reduction effect is about $1.6^{\circ}C$(5.5%), and for the comfort level, it is found that pmv index increases 8%. Second, based on the simulation of distance length with the sphere, it is more effective as it is close to the surface. If distance length is more than 0.5m, there is no effect on reduction of temperature and comfort level of indoor environment. Lastly, for the analysis by location of the introduced water space, simulation is undertaken by dividing the water space (14% of the indoor size) with front, side, rear and center types. Temperature reduction effect is found to be : front type ($-1.53^{\circ}C$), side type ($-0.82^{\circ}C$), rear type ($-0.44^{\circ}C$), center type ($-0.28^{\circ}C$), respectively. The indoor environment change data by introduction of water space, found in this research, is at initial phase, but it is deemed to be a basic data to refer when planning actual water space.

A Study on the Place of Break Chair Thermal Environment Change with the Introduction of the Indoor Water Space (실내 수공간으로 인한 온열환경 변화와 휴식의자 배치 방안)

  • Kang, Yujin;Song, Junhee;Chung, Okyoung;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.24 no.3
    • /
    • pp.239-246
    • /
    • 2013
  • Recently the building is introducing the indoor water space. Thermal environment change with the introduction. Consequently, this study shows how water space in the public facility affects the indoor environment. We had put our experiment to measure the humidity and temperature differences in different distances of water space. The result of this study is as follows. First, We found that even though there's a water space, it makes no big change in temperature by different distance. The temperature was only maintained by a cooler. Second, As there's a water space, the humidity was affected by within 1.5 m of it. Through our experimental result, we have started our study to make a water space effective.

  • PDF

The Experimental Study on a Effect of Korean Paper (Hanji) on Indoor Humidity Control (한지(韓紙)가 실내습도조절에 미치는 영향에 관한 실험적 연구)

  • 이종원;임정명
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.6
    • /
    • pp.599-607
    • /
    • 2004
  • The purpose of this study is to reevaluate the performance of Hanji as an architectural material. Hanji has good things in controlling indoor space comfortably. Particularly, ability of controlling humidity of Hanji affects indoor space comfort and human health. The major focuses of this experimental research are (1) how much of water vapor passes through Hanji, (2) how much of water vapor is absorbed into Hanji. In the first case, indoor humidity is higher than outdoor humidity. In this case, approximately 38 g of water vapor passes through Hanji 1, genarally utilized in window paper (Changhoji), per square meter in one hour. And approximately 4 g of water vapor is absorbed into Hanji 2, genarally utilized in wallpaper, per square meter. In the second case, outdoor humidity is higher than indoor humidity. In this case, Hanji passes water vapor to inner space at first, but when indoor relative humidity reach approximately 66%, although outdoor humidity is higher than indoor humidity, water vapor doesn't pass through Hanji. If Hanji is utilized in window material and wallpaper, indoor space is maintained comfortably without mechanical devices in humidity control.

Analyzing the Change of Indoor Thermal Environment with the Introduction of the Water Space in Exterior Housing (주거 외부 수공간 도입에 따른 실내 온열 환경 변화 분석)

  • Oh, Sang-Mok;Oh, Se-Gyu;Won, Hyun-Seong
    • Journal of the Korean housing association
    • /
    • v.21 no.2
    • /
    • pp.41-48
    • /
    • 2010
  • This study shows how the water space outside the housing impacts the indoor thermal environment. CFD simulation was used for this experiment to analyze the interior environment focusing on the effect of temperature control and the thermal comfort. A shape of perfect square, which creates the very basic space formation, was used and the simulation was processed looking at the size, distance, and the location of the water space. The results of the experiment are as follows. Firstly, introducing a water space with the same floor area size of the simulation model decreased the indoor temperature by 1 Celsius (3.72%). It was determined the interior environment was considered as a comfort zone when the water space was greater than 70% of the floor area. Secondly, there was not much influence to the level of thermal comfort of the interior environment when the distance to the water space from the housing was greater than 2 meters. Lastly, interpreting the location of water space, the effect of controlling the total areas' temperature was the greatest following with the surrounding of the formation. There barely was any change to the temperature considering the side and the rear of the area.

Analysis on Characteristics of Thermal Flow for Heating Indoor Space by Air-heating Collector using Solar Heat (태양열 공기가열 집열기에 의한 난방 실내공간의 열유동 특성 해석)

  • Yang, Young-Joon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.2_2
    • /
    • pp.271-278
    • /
    • 2022
  • The solar energy has been widely used to reduce the fossil fuel and prevent the environmental pollution. The renewable energy including solar heat tends to spread due to carbon neutrality for main country of the world. Targets of solar collector are usually acquisitions of hot water or hot air. Especially, air-heating collector using solar heat is known as the technology for obtaining hot air. This study aims to investigate of characteristics of thermal flow when the hot air by air-heating collector using solar heat flows inside of indoor space. The thermal flow of heating indoor space was simulated using ANSYS-CFX program and thus the behaviors of hot air in indoor space were evaluated with standard k-𝜀 turbulence model. As the results, as the inlet velocity was increased, the behaviors of hot air became simple, and temperature range of 25~75℃ had almost no effect on behavior of flow. As the inlet temperature was increased, the temperature curve of indoor space from bottom to top was changed from linear to quadratic. Furthermore, it was confirmed that inlet velocity as well as inlet temperature also should be considered to heat indoor space equally by air-heating collector using solar heat.

Effect of Functional Hanji Using Wood Ceramics on Indoor Humidity Control (우드세라믹을 첨가한 기능성 한지가 실내습도 조절에 미치는 영향)

  • Lim, Hyun-A;Oh, Seung-Won;Kang, Jin-Ha
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.2 s.115
    • /
    • pp.35-42
    • /
    • 2006
  • This study was carried out to develop a new application field of traditional Hanji and obtain the basic data for producing functional Hanji using sawdust ceramics and rice-husk ceramics as an architectural material. The results measuring water vapor permeance and water vapor absorption for using window materials and wallpapers are as follows. Hanji wallpaper has good things in controlling indoor space comfortably. Particularly, ability of controlling humidity of Hanji wallpaper affects indoor space comfort and human health. In the case indoor humidity is higher than outdoor humidity, according to the addition of ceramics, Hanji wallpapers maintain the humidity by retaining water vapor molecules in the pores of ceramics. Thus the Hanji wallpapers with ceramics, in particular rice-husk ceramics, make it superior to non-ceramics Hanji wallpapers in maintaining the humidity indoors.

Plant Growth Responses and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System (벽면형 식물바이오필터 내 식물 생육 및 실내공기질 정화)

  • Jung, Seul Ki;Chun, Man Young;Lee, Chang Hee
    • Korean Journal of Plant Resources
    • /
    • v.28 no.5
    • /
    • pp.665-674
    • /
    • 2015
  • The final goal of this research is to develop a botanical biofiltration system, which combines green interior, biofiltering, and automatic irrigation, which can purify indoor air pollutants according to indoor space and the size of biofilter. The biofilter used in this experiment was designed as an integral form of water metering pump, water tank, blower, humidifier, and multi-level planting space in order to be more suitable for indoor space utilization. This study was performed to compare indoor air quality between the space adjacent to a botanical biofilter and the space away from the biofilter (control) without generation of artificial indoor air pollutants, and to evaluate plant growth depending on multiple floors within the biofilter. Each concentration of indoor air pollutants such as TVOCs, monoxide, and dioxide in the space treated with the biofilter was lower than that of control. Dracaena sanderiana ‘Vitoria’ and Epipremnum aureum ‘N Joy’ also showed normal growth responses regardless of multiple floors within the biofilter. Hence, it was confirmed that the wall-typed botanical biofilter suitable for indoor plants was effective for indoor air purification.

A Study on the Temperature Characteristics of the Floor Cooling System of Mock-up Experimentent (Mock-up실험에 의한 바닥복사 냉방시스템의 온도특성에 관한 연구)

  • Yoo, Ho-Chun;Lee, Young-A
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.48-57
    • /
    • 2008
  • The research analyzed the distribution of the indoor temperatures of a radiant floor cooling system through mock-up experiments. It investigated the temperature difference of feed water, the vertical temperature difference of indoor air, the temperature difference of floor surface, and so on. The following is the results of the research. First, the research shows that the difference between indoor temperature and outside temperature was the smallest when the temperature of feed water was set at 16$^{\circ}C$. In addition, the temperature changes according to indoor positions (wall, room, floor, and ceiling) were the most uniform. Thus, the research found that the cold water temperature of 16$^{\circ}C$ is the most proper. In addition, it confirmed that the feed water temperature of 18$^{\circ}C$ is effective because the temperature can lower the temperature of a room to 13.55$^{\circ}C$, which is lower than the temperature of a non-cooling mode. Second, an investigation on the temperature distribution of vertical air in indoor space shows that the temperature distribution had a difference of 0.2 to 1.9$^{\circ}C$ on the average, which satisfies the range of 3.0$^{\circ}C$ in the standard of ISO.

Micro Porous Clay Mineral Absorption / Desorption Moisture-Proof Performance of The Atmospheric Humidity and Decomposing The Polyamide Adsorption Performance Characterization of Formaldehyde (미세 다공질 광물과 아미드계 분해제의 적용을 통한 건축자재의 습도 조절과 폼알데히드 분해 성능 특성 평가)

  • Lee, Che Cheol;Kim, Yun Hwan;Yun, Seng Hee
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.105-109
    • /
    • 2014
  • The recent rising living standards, environment-friendly, well-being and health aspects of life in the basic gratification, as well as the desire for a pleasant environment emotionally environmentally friendly way of external space or industrial interest in the indoor environment, the manifestation. In particular, the biggest problem of the indoor environment has been emerged as a Sick House Syndrome indoor space that is provided to the building materials, and the impact on the domestic and the indoor environment, and clean the house in a health standards are specified as laws. The performance rating and the various materials to create environmentally-friendly standards for building materials. The more detail, Porous clay material, toxic substances released by applying the high humidity and the water itself, and to absorb the moisture, if the emissions, without a separate device, to maintain a comfortable indoor environment and at the same time, one of the causes of Sick House Syndrome breaking down harmful substances to absorb a comfortable indoor environment to maintain an environmentally-friendly building interior material studies. It is aimed at the development to multi-functional high performance eco-friendly construction materials, rather than through one feature performance, identify key features for national and international eco-friendly building materials can exert Water Vapour Adsorption raw, decomposed materials for the application and selection.