• Title/Summary/Keyword: Indoor materials

Search Result 604, Processing Time 0.031 seconds

Evaluation of Pollutants Emissions according to the Selling Store in Department Store (백화점 내 업종별 판매매장에 따른 오염물질 배출현황 평가)

  • Wang, HyeongSeok;Hwang, JunSeok;Chang, SeongJin;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.26 no.1
    • /
    • pp.71-76
    • /
    • 2015
  • It is important thing that air quality affects human health. And It is more important thing that Indoor Air Quality more affects human health than Outdoor Air Quality. The cause of that is indoor air pollutants are more absorbed than outdoor air pollutants. By the way, in case of Multi-use facility for example office, department store, school etc., it has a feature that there are more people than any other buildings. therethrough, effects of Indoor Air Quality of Multi-use facility affect more people's health than Indoor Air Quality of any other buildings. However, in multi-use facility, specifically retail store, chemical treated materials are used for interior finishing, showcase finishing and product finishing because esthetic element is more added for detention of customer. Consequently, in place where demands brisk sales, possibility that indoor air is polluted by VOCs is high. This study considered retail store's Indoor Air Quality. as result of experiment, figure of department store's air pollution exceed about 5~20 times in guideline of multi-use facility's Indoor Air Quality in any kind of shop of department store (guideline : $500{\mu}g/m^3$).

Recent Advances in Titania-based Composites for Photocatalytic Degradation of Indoor Volatile Organic Compounds

  • Raza, Nadeem;Kim, Ki-Hyun;Agbe, Henry;Kailasa, Suresh Kumar;Szulejko, Jan E.;Brown, Richard J.C.
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.217-234
    • /
    • 2017
  • Indoor air pollutants can cause severe health problems, specifically in terms of toxicological impacts on human. Every day, a complex mixture of many air pollutants is emitted from various sources and subject to atmospheric processes that can create varied classes of pollutants such as carboxylic acids, aldehydes, ketones, peroxyacetyl nitrate, and hydrocarbons. To adhere to indoor air quality standards, a number of techniques such as photocatalytic oxidation of various volatile organic compounds (VOCs) have been employed. Among these techniques, titania ($TiO_2$) based photocatalytic reactions have proven to be the best benchmark standard approach in the field of environmental applications. Over the last 45 years, $TiO_2$-based photocatalytic reactions have been explored for the degradation of various pollutants. This review discusses the indoor air quality profile, types of indoor pollutants, available indoor air cleaning approaches, and performance of $TiO_2$-based catalysts. Finally, we have presented the perspectives on the progress of $TiO_2$ induced photocatalysis for the purification of indoor air.

An Investigation and Analysis into the Architectural Conditions and Indoor Air Quality of Senior Citizens Public Welfare Institution in Incheon (인천지역 공공 노인복지시설의 건축조건과 실내공기질에 대한 실태조사 및 분석)

  • Kang, Seung A;Shin, Sung Shik;Kim, Yong Shik
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.59-64
    • /
    • 2009
  • The senior citizens population and welfare institution for them is increased. The senior citizens in welfare institution spend a long time in indoor and their health is greatly affected by the indoor environment. Therefore, the indoor environment of senior citizens welfare institution is very important. This study presents some primary data based on the survey of architectural conditions and the measurements of indoor air quality for senior citizens welfare institution. According to characteristic of region, six of Incheon Area's senior citizens public welfare institution are selected. An investigation and analysis into architectural conditions and indoor air quality including temperature, humidity, CO, $CO_2$, PM10, HCHO, TVOC are conducted. The temperature, humidity and $CO_2$ concentration is some high. The HCHO concentration is very high. The indoor flooring and furniture materials highly impacts on the concentration of HCHO and TVOC.

A Study on the Indoor Thermal Comfort of the House with Ondol Heating System of Korean Traditional Housing (전통온돌난방의 실내 온열환경 쾌적감 평가에 관한 연구)

  • Kang, Sang-Woo;Jeon, Ji-Hyeon;Kook, Chan
    • Journal of the Korean housing association
    • /
    • v.18 no.4
    • /
    • pp.1-7
    • /
    • 2007
  • The principle of Korean Traditional Housing was to be harmonized with the nature with shapes according to regional climate and materials easily available from the region. These environmentally friendly characteristics protected indoor environment from climate changes. The characteristics of Korean traditional housing to control indoor environment would be very useful for contemporary housing in that current issues, improving housing amenity and wellbeing, had basic goals same with what Korean Traditional Housing had. Though it could be found characteristics of indoor thermal environment heated by Ondol Heating System, analyses of evaluation made by occupants of the rooms were insufficient because most of the studies had been focused on the measurement of indoor thermal factors. Thus, with an evaluation of occupants for the indoor thermal comfort and an estimation of discomfort derived from the result of vertical temperature distribution, it was studied whether the agreeable indoor range of rooms, of which was Jeonju Hanok Living Experience Center, heated by Ondol Heating System corresponded to the agreeable indoor range presented in references.

Evaluation of Indoor Air Improvement of Matrix Using Activated clay as Adsorption Material (활성백토를 흡착재로 활용한 경화체의 실내 공기 개선 평가)

  • Jeong, Hyun-Su;Kim, Yeon-Ho;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.189-190
    • /
    • 2020
  • The importance of indoor air quality management has recently been highlighted due to environmental problems such as indoor air pollution. Among indoor air pollutants, carbon dioxide occurs in cooking, heating, burning, and causes forgetfulness, dementia and amnesia. Radon, which occurs in building materials, soil and ground, is a type 1 carcinogen that causes lung cancer in the body through breathing. These substances can be released from the room through ventilation, but there is a limit to reducing the amount of indoor activity due to reduced ventilation conditions due to increased indoor activity time. However, these substances can be removed from the gas by adsorption. The purpose of this study was to identify the properties of granular active and powdered active white soil and mix them to make cement-based active white soil adsorbent matrix for carbon dioxide, fine dust and radon gas adsorption, and to evaluate indoor air improvements according to the mixing scale. The results of the experiment showed that active carbon dioxide adsorption performance increased for carbon dioxide and radon as the exchange rate increased through physical adsorption. In particular, the higher the replacement rate of the granular active bag, the better adsorption performance was shown.

  • PDF

Xylene Sensor Using Cr-doped Cr-Co3O4 Nanoparticles Prepared by Flame Spray Pyrolysis (화염 분무 열분해법으로 합성된 Cr-Co3O4 나노입자 자일렌 가스센서)

  • Jeong, Seong-Yong;Jo, Young-Moo;Kang, Yun Chan;Lee, Jong-Heun
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.112-117
    • /
    • 2020
  • Xylene is a hazardous volatile organic compound that should be precisely measured to monitor indoor air quality. However, the selective and sensitive detection of ppm-level xylene using oxide-semiconductor gas sensors remains a challenge. In this study, pure and Cr-doped Co3O4 nanoparticles (NPs) were prepared using flame spray pyrolysis, and their gas-sensing characteristics to 5-ppm xylene at 250 ℃ were investigated. The 4 at% Cr-doped Co3O4 NPs exhibited a high gas response to 5-ppm xylene (resistance ratio to gas and air = 39.1) and negligible cross-responses to other representative and ubiquitous indoor pollutants such as ethanol, benzene, formaldehyde, carbon monoxide, and ammonia. In this paper, the enhancement of the gas response and selectivity of Co3O4 NPs to xylene by Cr doping was discussed in relation to the catalytic promotion of the gas-sensing reaction. This sensor can be used to monitor indoor xylene.

Effect of Black Charcoal and Activated Carbon for Reduction of Radon Radioactivity that Emitted from Building Materials (건축재료로부터 방출되는 라돈방사능 감소를 위한 흑탄과 활성탄 효과)

  • Cho, Yun-Min;Lee, Hwa-Hyung
    • Journal of the Korea Furniture Society
    • /
    • v.22 no.1
    • /
    • pp.13-17
    • /
    • 2011
  • Recently, interest in indoor air quality is increasing. Especially, radon radioactivity among the indoor air is a well-known risk factor for lung cancer because of ionizing radiation in the form of ${\alpha}$-particles. This study was carried out to investigate effect of black charcoal and activated carbon for reduction of radon radiation that emitted from building materials. Black charcoal and activated carbon were used as a barrier which was against the infiltration of radon. The source of radon was gypsum board. Two types of charcoal barrier were powder- and board-type with 5 mm, 10 mm thickness respectively. The method for this determination is evaluated radon concentration in chamber. The measurements were performed with radon detector, SARAD3120. Results of this study are as following: Black charcoal and activated carbon confirmed the highly efficient barrier. Radon concentration was reduced from 72% to 85% as compared the control chamber. Radon reduction capability, however, was no difference as barrier's types. Results obtained in ventilation condition, radon concentration shows 5.93 pCi/L on average in the closed condition and shows 2.69 pCi/L in the opened condition.

  • PDF

Fine Dust Adsorption of Cement Matrix Using Sepiolite (세피올라이트를 활용한 시멘트 경화체의 미세먼지 흡착 특성 )

  • Jeon, Eun-Yeong;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.71-72
    • /
    • 2023
  • As industrialization and urbanization accelerate, environmental issues have moved from local concerns to global issues. Among them, air pollution is the most important issue. Modern people spend more than 88% of their day indoors, but the concentration of fine dust and pollutants flowing indoors is increasing. The indoor environment has its own complexity, and various substances used indoors, such as building materials, furniture, electronics, and cleaning agents, emit chemical substances and cause various diseases. Therefore, when selecting building materials and interior finishing materials, the pollutant emission and adsorption capacity must be greatly considered. These considerations will ensure the construction of a sustainable future environment and a healthy life within that environment. Therefore, in order to reduce the generation of indoor air pollutants, this study aims to examine the fine dust adsorption properties of cement hardening materials using sepiolite, which has a porous structure and high absorption power among clay minerals. As a result of the experiment, it was found that the concentration of fine dust decreased as the addition rate of sepiolite increased. It is believed that the fine dust concentration was reduced due to the high porosity due to the microfibrous structure and large specific surface area of sepiolite, which has a porous structure among clay minerals. It is believed that these experimental results can be used as basic research for future use of sepiolite as a construction material.

  • PDF

A Study on the Calculation of Ventilation Rate for the Improvement of Indoor Air Quality on the Barracks (군 내무실의 실내공기질 개선을 위한 환기량 산정에 관한 연구)

  • Choi Jeong-Min;Yu Jin-Sang;Jeong Young-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1043-1049
    • /
    • 2005
  • The purpose of this study is to improve indoor air quality of the barracks which have been changed from floor-type living barracks to bed-type living barracks since 2003. Therefore, the ventilation rates of newly constructed two type barracks were simulated with the various building materials including VOCs and HCHO components. And indoor air quality of two type living barracks was measured by the field experiments. With these steps, the measures for upgrading indoor air quality depending on building material types and ventilation rate are suggested.