• Title/Summary/Keyword: Indoor load

Search Result 260, Processing Time 0.026 seconds

An Experimental Study of Tire Safety & Economical Efficiency with Respect to Inflation Pressure (공기압에 따른 타이어의 안전성 및 경제성에 관한 실험적 연구)

  • Hong, Seung-Jun;Lee, Ho-Guen
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.1
    • /
    • pp.8-13
    • /
    • 2010
  • Many vehicles have significantly under-inflated tires, primarily because drivers infrequently check their vehicles' tire pressure. When a tire is used while significantly under-inflated, its sidewalls flex more and the tire temperature increases, increasing stress and the risk of failure. In this study we evaluated tire safety and economical efficiency at various inflation pressure. For tire safety we performed FMVSS indoor durability test, measurement of rolling tire temperature, braking performance at dry/wet road condition, and rolling resistance test for economical efficiency. Results show that low pressure decreases tire durability of both speed-increase condition and load-increase condition. Heat temperature of rolling tire increases as pressure decreases and significantly under-inflated tires cause increase of vehicle's stopping distance at wet road condition. Also Under-inflation increases the rolling resistance of a tire and, correspondingly, decreases vehicle's fuel economy.

Development of 1 kW class PEFC co-generation system for buildings (1kW 급 건물용 연료전지 시스템 개발 현황)

  • Jun, Hee-Kwon;Hwang, Jung-Tae;Lee, Kap-Sik;Choi, Choeng-Hoon;Lee, Dong-Hwal;Bae, Joon-Kang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.328-330
    • /
    • 2009
  • 1 kW class Polymer Electrolyte Fuel Cell(PEFC) co-generation systems have been developed from 2001 and evaluated for improvement of efficiency, durability and reliability of the system. This paper introduce new version system including with excellent reliability, durability and user friendly applications. Its electrical and overall efficiency showed 35 % and 80 %, respectively, and noise level of the system was less than 45 dB. In addition, this system have various functions such as load change, $N_2$ less purge, low emission and low temperature operation ($-15^{\circ}C$) through development of operation logic. This system was designed for convenient installation in indoor and outdoor due to the compactness of size and the separation of electrical and heat recovery units, which means a user can select the size of heat recovery unit.

  • PDF

An Experimental Study on Evaluation of the Sound Insulation for Balcony Window in Apartment Houses (공동주택 발코니 창호의 차음성능 평가에 관한 실험적 연구)

  • 김하근
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1137-1146
    • /
    • 2004
  • In an apartment house In Korea, the balcony is one of the important spaces as a buffer zone for controlling the outdoor environments such as noise, heating & cooling load, humidity etc. Because most areas of building facade in apartment building occupy the area of balcony window the sound Insulation design of It Is very Important to provide the quiet indoor environment. The aim of this research is to evaluate the sound insulation of balcony windows in apartment building by new and revised Korean Industrial Standards. We measured and studied the sound insulations of 18 balcony windows by the type of measuring methods, noise sources, correction of reverberation time in balcony and so on. The results show that the single-number quantities for sound insulation of windows are ranged from 24 dB to 30 dB.

A Study on the Development of Lightweight Wall for Sound Transmission Loss and Field Test Results of the Dry-Wall System (차음성능이 향상된 경량벽체 개발 및 성능평가 연구)

  • 이병권;배상환;홍천화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.699-704
    • /
    • 2004
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings, it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But, the required performances of a light-weight wall are not evaluated systematically. As a field survey result, partition walls of house-to-house were not showed their respected performances, so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially, occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings. As a result, a new drywall system was presented and the performance was verified with field test.

  • PDF

Experimental study on the deformation property of pneumatic tires - strain gauge method (실험적 방법에 의한 Tire 변형 특성 연구)

  • Kang, S.C.;Ku, B.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.716-721
    • /
    • 2001
  • The present study describes the experimental method to measure the strain of tire. In this study. the strain distributions of tire with air pressure and vertical load were measured at the bead filler edge region and on the carcass cord using strain gauges and the results were compared with indoor bead durability test results. The strain amplitude of carcass cord near the rim check line of tire is one of the main factors that affects bead durability characteristic.

  • PDF

Time Slot Allocation for CDMA/TDD Indoor Wireless Systems

  • Lee Chae Y.;Sung Ki Won
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2002.05a
    • /
    • pp.144-151
    • /
    • 2002
  • Future wireless communication systems are expected to provide a broad range of multimedia services in which the asymmetry of traffic load between uplink and downlink is a significant feature. The rode division multiple access system with tune division duplex mode (CDMA/TDD) is a good solution to cope with the traffic asymmetry problem. However. the TDD system is subject to inter-cell interference compared to frequency division duplex (FDD) system. Since both uplink and downlink share the same frequency in TDD. uplink and downlink may interfere each other especially when neighboring cells require different rates of asymmetry. Thus, time slot allocation for tells is an important issue in TDD. In this paper. we propose a genetic algorithm based time slot allocation scheme which maximizes the residual system capacity. The proposed scheme allows that each cell employ different level of uplink/downlink asymmetry and satisfies the interference requirement.

  • PDF

Evaluation of Thermal Environment on Air-barrier Type Perimeter-less System with Underfloor Air Conditioning System (바닥급기 공조시 에어베리어형 페리미터레스 공조시스템의 실내 열환경 평가)

  • 김용경;이정재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.346-351
    • /
    • 2003
  • This paper aims at suggesting design guidelines for a perimeter-less HVAC system that contributes energy savings. Perimeter-less HVAC system is one that relieves difficulties fuck as handling mixing loss, uneven radiative environment, and maintenance and repair. It prevents heat load gained through window and outdoor wall without modifying a previously equipped building skin system. In this paper, we performed several kinds of CFD (computational fluid dynamics) cases through numerical simulation to obtain an optimized perimeter-less design, and then we conducted a large-scale model experiment to see how the push-pull air flow would handle indoor heat to obtain an optimized perimeter-less design.

Development of a Real-Time Steady State Detector of a Heat Pump System to Develop Fault Detection and Diagnosis System (열펌프의 고장진단시스템 구축을 위한 정상상태 진단기 개발)

  • Kim, Min-Sung;Yoon, Seok-Ho;Kim, Min-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2070-2075
    • /
    • 2008
  • Identification of steady-state is the first step in developing a fault detection and diagnosis (FDD) system. In a complete FDD system, the steady-state detector will be included as a module in a self-learning algorithm which enables the working system's reference model to "tune" itself to its particular installation. In this study, a steady-state detector of a residential air conditioner based on moving windows was designed. Seven representing measurements were selected as key features for steady-state detection. The optimized moving window size and the feature thresholds was suggested through startup transient test and no-fault steady-state test. Performance of the steady-state detector was verified during indoor load change test. From the research, the general methodology to design a moving window steady-state detector was provided for vapor compression applications.

  • PDF

Radiation Heat-Transfer Coefficient of the Indoor Surface in Ondol Heating Space (온돌난방공간(溫突暖房空間)의 내표면(內表面) 복사열전달률(輻射熱傳達率)에 관(關)한 연구(硏究))

  • Sohn, J.Y.;Ahn, B.W.;Shin, Y.T.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.5
    • /
    • pp.598-606
    • /
    • 1988
  • The radiation heat-transfer coefficient is generally used to calculate radiant heat exchange of heating space. The coefficient is evenly adopted in most cases, but it is not correct in actual cases. The purpose of this paper is to grasp the changing aspect of radiation heat-transfer coefficient needed for heating load calculation of radiant heating space. Surface temperatures are measured in an Ondol space, and the coefficients are derived and examined. Gebhart's Absorption Factor Method is used for the calculations of the rates of instantaneous radiant exchange in the room. As the result, it is confirmed that the coefficients are variant according to surface temperatures, and proper coefficients are needed for each of conditions.

  • PDF

Multiple Units Control of Boiler and Refrigerator in HVAC System (공조용(空調用) 열원기기(熱源機器)의 대수분리(臺數分離) 제어(制御)에 관한 연구(硏究))

  • Sohn, J.Y.;Kim, H.S.;Ahn, B.W.;Shin, Y.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.1
    • /
    • pp.1-10
    • /
    • 1992
  • The purpose of this paper is to provide an efficient method of operating and designing HVAC systems for reasonable energy consumption in building. Accroding to the conditions of indoor temperature and humidity, and the methods of dividing and grouping the capacity of boiler and refrigerator, the amount of their annual energy consumptions is simulated by using an energy analysis program which is developed in this paper, and opatimal design methods of HVAC system are suggested as well.

  • PDF