• Title/Summary/Keyword: Indoor dust

Search Result 240, Processing Time 0.033 seconds

Analyses of the current market trend and research status of indoor air quality control to develop an electrostatic force-based dust control technique (정전기적 힘을 이용한 실내공기 미세부유먼지 제거 요소기술의 개발을 위한 기술별 시장현황 및 연구 동향 분석)

  • Yoon, Young H.;Joo, Jin-Chul;Ahn, Ho-Sang;Nam, Sook-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6610-6617
    • /
    • 2013
  • This study examined the current and future Indoor Air Quality (IAQ) control device markets and analyzed the recent studies on indoor air pollutantr emoval to develop a new technology for fine dust control. Currently, the mechanical filter technique occupies the bulk of the IAQ control market but the electronic technique is emerging as an alternative to control fine dust efficiently. Among the gaseous VOCs and fine dust particles contaminating the indoor air quality, fine dust particles are more problematic because they threaten human health by penetrating deep into the body and producing secondary contaminants by chemical reaction with VOCs. The electronic IAQ control device using dielectrophoretic and electrostatic forces is a good option for public spaces where many people pass, and at the same time, it needs to consider temperature, humidity, and the particle properties of specific areas to highlight the control efficiency. Electronic-related technology is expected to be used widely in many public/private spaces wherever a dust-free environment is required.

Study on the Characteristics of Air quality in the Classroom of Elementary School and Its Control Methods (초등학교 교실공기질의 특징과 제어방안에 관한 연구)

  • Jeong, Ji-Won;Lee, Hee-Kwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.311-322
    • /
    • 2010
  • The common life with modern urban residence, spending more than 80~90% of daily life in indoor environment, makes the importance of indoor air quality (IAQ) even higher. Many efforts have made to improve indoor air quality (IAQ), which requires those systematic approaches for field practice. A recent study reported that no general approach cannot be made for IAQ improvement due to the great deal of variety in different indoor environments. Those indoor spaces included in Korean IAQ regulation were classified based on their characteristics and the IAQ guideline was suggested for each group of indoor spaces. Apart from those indoor spaces, the classroom in elementary school has different characteristics. By introducing the systematic approaches, the elementary classroom was surveyed and analyzed to understand its characteristics in due IAQ consideration. Based on the characteristics, there are several IAQ control measures suggested, including ventilation operation, dust mat installation, and white board. $CO_2$ and airborne dust were monitored and analyzed in order to evaluate the effectiveness of each control measure to IAQ. It was found that the general level of $CO_2$ concentration was managed under the IAQ guideline by applying the ventilator operation. The ventilation was also effective to the fugitive airborne particulate in elementary classroom environment.

A Study on Air Pollution in Indoor Gymnasiums (실내체육관에서의 공기오염에 관한 연구)

  • 윤승욱;김윤신;이종대;이철민;조용성
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.32-37
    • /
    • 2000
  • Nowadays, a new word called SBS(sick building syndrome) has been come into existence. At the point of time when an interest about indoor air pollution and, according to this, countermeasure plan are internationally. Moreover institutional countermeasure should be attended at national level since indoor air quality in public places where many people gather is directly connected with national health. Especially indoor pollution of indoor stadia where all sorts of sports are held can give rise to every kinds of respiratory ailments to players as well as audiences. So it is presented as a main factor that indoor space of stadia is crowded with players and audiences compared with other kinds of indoor space. Therefore, in this research to analyze pollution degree of indoor circumstance for gymnasium and exercising room of folk wrestling. basketball, judo, wrestling, hapkido, swordsmanship and boxing making indoor gymnasium and exercising room an object, when 7 items were measures such as thermocircumstance(temperature, relative humidity, air current, intensity of illumination), dust, carbon monoxide, and carbon dioxide being based on the indoor environmental standard of the first clause of Article 45 of public utilization service which is showed at public hygiene of the Ministry of Health and Social Affairs, it was showed that indoor temperature, relative humidity, air current and intensity of illumination were over standard amount at the most of folk wrestling gymnasium and exercising room. Indoor density of carbon monoxide was preserved to the extent of standard amount (10ppm) at all gymnasiums but carbon dioxide was not in excess of standard amount(1,000 ppm) at most of gymnasiums. Indoor density of dust induced from respiration exceeded the standard amount (150 $\mu\textrm{g}$/㎥) at all gymnasiums of the folk wrestling. Since the folk wrestling players and participants feel physical subjective symptom seriously, in other words the degree of indoor air pollution at gymnasiums and exercising rooms of the folk wrestling is very high, fundamental solution and countermeasure plan should be presented.

  • PDF

Performance Evaluation of Window Ventilation System for Reducing Indoor particulate matter (실내 미세먼지 저감을 위한 창호형 환기시스템 성능평가)

  • Yang, Young Kwon;Park, Jin Chul
    • Land and Housing Review
    • /
    • v.10 no.3
    • /
    • pp.1-7
    • /
    • 2019
  • Indoor particulate matter(PM) is a carcinogen and needs to be removed and managed. It is generally reduced and removed through ventilation and filtration. Owing to the recent occurrence of high-concentration fine dust and yellow dust in the atmosphere, however, it is difficult to expect the purification of indoor air through the simple introduction of the outside air. For residential buildings, in particular, they are highly dependent on natural ventilation but the lack of natural ventilation is worsening because concerns over the inflow of external pollutants are increasing. Therefore, this study designed and manufactured a window ventilation system that does not require a duct to improve the maintenance and management problems of general ventilation system, and constructed indoor PM concentration change data through performance evaluation.

A Study on the Electrostatic Precipitation as a Function of Resistivity using various Indoor Dusts (실내 분진의 비저항 특성에 따른 전기집진 효율에 대한 연구)

  • Cheong, Seong-Ir;Choi, Young-Min;Ahn, Young-Chull;Lee, Jea-Keun;Kangk, Eun-Chull;Lee, Euy-Joon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.448-453
    • /
    • 2006
  • Electrical resistivity is an important property for the collection efficiency in the electrostatic precipitator. In this paper, electrical resistivities of tobacco dusts, yellow sand dusts and pine pollens are measured using a high voltage conductivity cell based on JIS B 9915. The resistivities of three kinds of indoor dusts are about $1{\times}10^7\;{\Omega}{\cdot}cm^2$ in the normal range and dust collection efficiency using an electrostatic precipitator at to face velocity of 1.0 m/s shows over 99% for the three kinds of indoor dusts.

  • PDF

Phthalates Contamination in Indoor Dust in Elementary Schools in Seoul: A Pilot Study (서울시 초등학교 실내 먼지 중 프탈레이트 오염실태 조사)

  • Lee, Young-Sun;Choi, Inja
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.5
    • /
    • pp.548-554
    • /
    • 2020
  • Objectives: This study is to examine the polyvinyl chloride (PVC) materials in elementary school classrooms and libraries in Seoul, and to investigate phthalate contamination in indoor dust. Methods: PVC material was identified for building materials and furniture using portable x-ray fluorescence (XRF). Phthalates in dust samples (n=19) were extracted by ultrasonic extraction using cyclohexane and analyzed by GC-MS. Results: Diethyl phthalate (DEP), di-n-butyl phthalate (DBP), and Bis (2-ethylhexyl) phthalate (DEHP) were found in all collected dust samples (n=19), and diisonyl phthalate (DINP) was detected in all except for one sample (n=18). The concentration of DEHP (median: 2190 mg/kg) and DINP (2960 mg/kg) were higher than other compounds, suggesting that there are many products in the school that used these compounds. When comparing the phthalate concentration in the classroom (n=11) and library dust (n=8), the total concentration in the classroom (median: 10000 mg/kg) was higher than that in the library (8030 mg/kg). DEHP was the dominant compound in the library. The library is relatively more equipped with PVC furniture (n=83) and most floors are also identified as PVC material, suggesting that floors and furniture made of PVC materials are main sources of DEHP contamination. Conclusions: This study is a pilot survey for investigating phthalate contamination in elementary schools. As a result of the survey, phthalate contamination in elementary school was confirmed. However, further study requires risk assessment of children through analysis of phthalate metabolites in children based on sufficient number of samples and information about the site.

A Study of Fine Dust Blocking Network Using Electrospinning Nanofiber Deposition (전기방사를 활용한 나노섬유 증착 미세먼지 방진망에 관한 연구)

  • Chan Young Lee;Sang Min Lee;Hyeon Jin Song;Jae Jun Lee;Young Soon Kim;Hong Gun Kim
    • Journal of The Korean Institute of Defense Technology
    • /
    • v.6 no.1
    • /
    • pp.13-18
    • /
    • 2024
  • While fine dust is currently spreading around the world, fine dust is so small that it easily enters indoors and deteriorates indoor air quality, so it is an essential issue that must be solved to maintain cleanliness and improve air quality in households. Research on nanoradiation technology is continuously being conducted to effectively block fine dust and secure air permeability and dust collection rate. In this study, a PVDF fine dust dust-proof net was manufactured through electrospinning, and an experiment was conducted to confirm the external environmental resistance and indoor air quality improvement efficiency of the manufactured dust-proof net. It was verified that this dustproof net can be a practical alternative to effectively block fine dust and prevent diseases caused by fine dust.

  • PDF

A study on power source characteristic of a dust collector for power factor compensating (역률보상형 전기집진기 전원장치 특성연구)

  • Lee, Dong-Gil;Hong, Ji-Tae;Kim, Ho-Sung;Son, Min-Kyu;Lee, Kyoung-Jun;Kim, Jong-Rak;Kim, Hee-Jea
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1326-1327
    • /
    • 2008
  • Recently, the air pollution is supposed is to be the most serious environmental problem. Therefore, a small air cleaner is asked to make comfortable indoor environment for the moderns who have frequent indoor activity. In this study, without generating of the second pollution source, dust in the air and harmful microorganisms can be removed by the electric dust collecting technology which has high reliability and efficiency to be able to remove the impurities even though it is just 0.01${\mu}m$. Accordingly, power sources of the dust collector use, it is not inefficiency and offering to dust collector unstable. In order to overcome the point at issue, a this study, for power factor compensating use the PFC circuit, for removing the noise use EMI filter and for generating the hight voltage use the Cockcroft Walton Circuit. And we study power source on characteristic and improvement.

  • PDF

Indoor Air Data Meter and Monitoring System (실내 공기 데이터 측정기 및 모니터링 시스템)

  • Jeon, Sungwoo;Lim, Hyunkeun;Park, Soonmo;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.1
    • /
    • pp.140-145
    • /
    • 2022
  • In an advanced modern society, among air pollutants caused by urban industrialization and public transportation, fine dust flows into indoors from the outdoors. The fine dust meter used indoors provides limited information and measures the pollution level differently, so there is a problem that users cannot monitor and monitor the data they want. To solve this problem, in this paper, indoor air quality data fine dust and ultra-fine dust (PM1.0, PM2.5, PM10), VOC (Volatile Organic Compounds) and PIR (Passive Infrared Sensor) are used to measure fine dust. and a monitoring system were designed and implemented. We propose a fine dust meter and monitoring system that is installed in a designated area to measure fine dust in real time, collects, stores, and visualizes data through App Engine of Google Cloud Platform and provides it to users.

Properties of Cement Matrix Using Vegetable Activated Carbon (식물성 활성탄을 활용한 시멘트 경화체의 특성)

  • Lee, Jae-Hoon;Park, Chae-Wool;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.138-139
    • /
    • 2020
  • With the rapid progress of industrialization, indoor air quality is a very important factor for modern people who spend most of their day indoors. The recent issue of fine dust and radon on the portal site's popularity search shows that interest in indoor air quality has increased. Fine dust causes respiratory diseases, and radon causes severe lung cancer. The new material was tested using plant activated carbon, palm activated carbon and bamboo activated carbon. Both palm activated carbon and bamboo activated carbon are porous materials and generate smooth physical adsorption. As a result of the experiment, both the activated carbon tends to gradually decrease in strength and fluidity as the replacement ratio increases. The reason for this is that both activated carbons have the property of absorbing moisture, so it is judged that the strength is lowered by absorbing moisture necessary for curing. In the case of fluidity, it is judged that the fluidity is reduced by absorbing the moisture required for the flow. In the future, if the problem of the color of the finished cured body is compensated, it will be possible to manufacture a functional finishing board to replace the existing interior finishing material.

  • PDF