Comparison of air pollution and the prevalence of allergy-related diseases in Incheon and Jeju City

  • Jeong, Su-Ho;Kim, Jeong-Hee;Son, Byong-Kwan;Hong, Seong-Chul;Kim, Su-Young;Lee, Geun-Hwa;Lim, Dae-Hyun
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.12
    • /
    • pp.501-506
    • /
    • 2011
  • Purpose: A high level of air pollutants can increase the number of patients with allergy-related diseases such as asthma and allergic rhinitis (AR). To analyze the association between air pollution and allergic disease, we investigated 2 areas in Korea: Incheon, an industrial area, and Jeju, a non-industrialized area. Methods: Second grade students at elementary schools (11 schools in Incheon and 45 schools in Jeju) were examined in a cross-sectional study. A questionnaire was used and a skin prick test was performed. The levels of $NO_2$, $CO_2$, $O_3$, particulate matter (PM) $PM_{10/2.5}$, formaldehyde, tVOCs, and dust mites in the classrooms and grounds were determined. Results: The levels of outdoor CO, $PM_{10}$, and $PM_{2.5}$ were significantly higher in Incheon (P<0.01). The levels of indoor CO, $CO_2$, $PM_{10}$, $PM_{2.5}$ were significantly higher in Incheon (P<0.01). The prevalence rates of AR symptoms at any time, AR symptoms during the last 12 months, diagnosis of rhinitis at any time, and AR treatment during the last 12 months were significantly higher in Incheon (P<0.01). The prevalence rate of wheezing or whistling at any time, and wheezing during the last 12 months were significantly higher in Incheon (P<0.01). Conclusion: We found that the children living in Incheon, which was more polluted than Jeju, had a higher rate of AR and asthma symptoms compared to children in Jeju. To determine the effect of air pollution on the development of the AR and asthma, further studies are needed.

Review on asbestos analysis (석면 분석방법에 대한 고찰)

  • Ham, Seung hon;Hwang, Sung Ho;Yoon, Chungsik;Park, Donguk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.213-232
    • /
    • 2009
  • This document was prepared to review and summarize the analytical methods for airborne and bulk asbestos. Basic principles, shortcomings and advantages for asbestos analytical instruments using phase contrast microscopy(PCM), polarized light microscopy(PLM), X-ray diffractometer (XRD), transmission electron microscopy(TEM), scanning electron microscopy(SEM) were reviewed. Both PCM and PLM are principal instrument for airborne and bulk asbestos analysis, respectively. If needed, analytical electron microscopy is employed to confirm asbestos identification. PCM is used originally for workplace airborne asbestos fiber and its application has been expanded to measure airborne fiber. Shortcoming of PCM is that it cannot differentiate true asbestos from non asbestos fiber form and its low resolution limit ($0.2{\sim}0.25{\mu}m$). The measurement of airborne asbestos fiber can be performed by EPA's Asbestos Hazard Emergency Response Act (AHERA) method, World Health Organization (WHO) method, International Standard Organization (ISO) 10312 method, Japan's Environmental Asbestos Monitoring method, and Standard method of Indoor Air Quality of Korea. The measurement of airborne asbestos fiber in workplace can be performed by National Institute for Occupational Safety and Health (NIOSH) 7400 method, NIOSH 7402 method, Occupational Safety and Health Administration (OSHA) ID-160 method, UK's Health and Safety Executive(HSE) Methods for the determination of hazardous substances (MDHS) 39/4 method and Korea Occupational Safety and Health Agency (KOSHA) CODE-A-1-2004 method of Korea. To analyze the bulk asbestos, stereo microscope (SM) and PLM is required by EPA -600/R-93/116 method. Most bulk asbestos can be identified by SM and PLM but one limitation of PLM is that it can not see very thin fiber (i.e., < $0.25{\mu}m$). Bulk asbestos analytical methods, including EPA-600/M4-82-020, EPA-600/R-93/116, OSHA ID-191, Laboratory approval program of New York were reviewed. Also, analytical methods for asbestos in soil, dust, water were briefly discussed. Analytical electron microscope, a transmission electron microscope equipped with selected area electron diffraction (SAED) and energy dispersive X-ray analyser(EDXA), has been known to be better to identify asbestiform than scanning electron microscope(SEM). Though there is no standard SEM procedures, SEM is known to be more suitable to analyze long, thin fiber and more cost-effective. Field emission scanning electron microscope (FE-SEM) imaging protocol was developed to identify asbestos fiber. Although many asbestos analytical methods are available, there is no method that can be applied to all type of samples. In order to detect asbestos with confidence, all advantages and disadvantages of each instrument and method for given sample should be considered.

Analysis of Changing Pattern of Noxious Gas Levels with Malodorous Substance Concentrations in Individual Stage of Pig Pens for 24 hrs to Improve Piggery Environment (돈사환경 개선을 위한 생육단계별 돈사내 악취물질 농도 및 유해가스의 1일 변화추세 분석)

  • You, Won-Gyun;Kim, Cho-Long;Lee, Myung-Gyu;Kim, Dong-Kyun
    • Journal of Animal Environmental Science
    • /
    • v.18 no.1
    • /
    • pp.25-34
    • /
    • 2012
  • Noxious gases with malodorous substance concentrations in each stages of pig buildings were determined at a typical 400sow-scale farm to improve piggery environment. Using IAQ-300 and pDR-1000AN, continuous records for the concentration of $NH_3$, CO, $CO_2$, $NO_2$, $SO_2$, $H_2S$, $O_2$, and along with temperature, humidity, dust concentrates from individual pig pens were collected to analyze every 6 hours' condition of indoor environment for 24 hours' period. In most pig houses, the air quality at noon was good, while at night (00:00~06:00), air composition became noxious in all buildings. The order of buildings' air quality for 24 hrs was pregnant > farrowing > nursery > growing > finishing. The cause of air quality differences was presumed to be the differences of stocking density, defecating amount and the length of exposure time of slurry in indoors. In conclusion, well-designed building structure, proper control of stocking density, quick removal of excreta from pig pens and continuous ventilation are prerequisites to improve pig housing environment.

Comparative Study of Soil Risk Assessment Models used in Developed Countries (선진국의 토양위해성평가 모델 비교분석 연구)

  • An, Youn-Joo;Baek, Yong-Wook;Lee, Woo-Mi;Jeong, Seung-Woo;Kim, Tae-Seung
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.1
    • /
    • pp.53-63
    • /
    • 2007
  • Soil risk assessment models were used to determine the goals of soil remediation and to establish the soil quality standards in developed countries. Recently, Korean Ministry of Environment prepared the guideline for soil risk assessment. Soil risk assessment model applicable to Korean situation will be needed in the near future. In this study, three models for soil risk assessment were extensively compared to suggest the fundamental components that required for the soil risk assessment in Korea. The models considered in this study were CalTOX in the United States, CLEA (Contaminated Land Exposure Assessment) in the United Kingdom, and CSOIL in the Netherlands. The major exposure routes and the intake estimation equations suitable for Korean situation were suggested. The exposure routes suggested were intake of the crops, underground water, indoor outdoor soil ingestion, dust inhalation and a volatile matter inhalation. The equations for intake estimation used in CalTOX and CSOIL seem to be applicable for the calculation of the human intake in Korea.

Study on the optimal design of floor exhaust system using computational fluid dynamics for subway platform (수치해석을 활용한 승강장 바닥배기 시스템 최적화 연구)

  • Namgung, Hyeong-Gyu;Park, Sechan;Kim, Minhae;Kim, Soo-Yeon;Kwon, Soon-Bark
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.443-449
    • /
    • 2017
  • The imbalance of air supply and the exhaust on subway platforms has led to the installation of platform screen doors in underground subway stations. This imbalance causes the accumulation of pollutants on the platform and loss of comfort due to the lack of ventilation. In this study, a floor exhaust system was optimized using computational fluid dynamics (CFD) and an optimization program. The optimized floor exhaust system was manufactured and tested experimentally to evaluate the particle collection efficiency. CFX 17.0 and HEEDS were used to analyze the flow field and optimize the principal dimensions of the exhaust system. As a result of the three-step optimization, the optimized floor exhaust system had a total height of 1.78 m, pressure drop of 430 Pa, and particle collection capability of 61%. A fine dust particle collection experiment was conducted using a floor exhaust system that was manufactured at full scale based on the optimized design. The experiment indicated about 65% particle collection efficiency. Therefore, the optimized design can be applied to subway platforms to draw in exhaust air and remove particulate matter at the same time.

The Study on the Environmental Factors of Atopic Dermatitis in Oriental-Western Medicine (아토피 피부염의 환경적 요인에 대한 동서의학적 고찰)

  • Park, Sung-gu;Noh, Hyeon-Min;Kweon, So-Hyoun;Jo, Eun-Hee;Jang, Hyun-Chul;Kim, Ho-kyoung;Park, Hi-Joon;Kim, Won-Jeong;Park, Min-Cheol
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.31 no.1
    • /
    • pp.52-70
    • /
    • 2018
  • Objectives : Atopic dermatitis(AD) and environmental factors are closely related, but there is lack of oriental medical examination. So we compared the relationship between AD and various environmental factors in Oriental medicine and Western medicine. Methods : We described the relationship between AD and environmental factors through the latest papers and a review of the oriental medicine literature. Results : The regional diversity of AD incidence implies a close relationship between climate factors and AD, and high altitude and low pH springs also have an effect on AD. Air pollutants from industrialization and urbanization aggravate AD. The increase in indoor residence time and the increase in room temperature and humidity have also increased the sensitization to allergens such as house dust mite. In oriental medicine, wind(風) is one of the environmental factors and is an inflammatory state due to external irritation. Wind-Humidity(風濕) refers to erythematous wetting dermatitis with itching and exudation, Wind-Fever(風熱) refers to acute inflammatory reaction with erythematous papules and plague, and Blood-Weakness(血虛) refers to aggravation and chronicization of inflammation due to persistence of skin barrier impairment. Conclusions : We examined the relationship between AD and various environmental factors. We also described the oriental medical viewpoints of the environmental factors in the occurrence of AD and skin barrier impairment.

A Study on the Research Topics and Trends in South Korea: Focusing on Particulate Matter (토픽모델링을 이용한 국내 미세먼지 연구 분류 및 연구동향 분석)

  • Park, Hyemin;Kim, Taeyong;Kwon, Daewoong;Heo, Junyong;Lee, Juyeon;Yang, Minjune
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_3
    • /
    • pp.873-885
    • /
    • 2022
  • The particulate matter (PM) has emerged as a hot topic around the world as it has been reported that PM is related to an increase in mortality and prevalence rates. In South Korea, the importance of PM has been recognized since the late 1990s, and various studies on PM have been conducted. This study investigated the PM research topics and trends for papers (D=2,764) published in Research Information Sharing Service (RISS) using topic modeling based on Latent Dirichlet Allocation (LDA). As a result, a total of 10 topics were identified in the whole papers, and the PM research topics were classified as 'PM reduction (Topic 1)', 'Government policy and management (Topic 2)', 'Characteristics of PM (Topic 3)', 'PM model (Topic 4)', 'Environmental education (Topic 5)', 'Bio (Topic 6)', 'Traffic (Topic 7)', 'Asian dust (Topic 8)', 'Indoor PM (Topic 9)', 'Human risk (Topic 10)'. In particular, the proportion of papers on topics 'Government policy and management (Topic 2)', 'PM model (Topic 4)', 'Environmental education (Topic 5)', and 'Bio (Topic 6)' to the toal number of papers increased over time (linear slope > 0). The results of this study provide the new literature review methodology related to particulate matter and the history and insight.

Toxicity of Organophosphorus Flame Retardants (OPFRs) and Their Mixtures in Aliivibrio fischeri and Human Hepatocyte HepG2 (인체 간세포주 HepG2 및 발광박테리아를 활용한 유기인계 난연제와 그 혼합물의 독성 스크리닝)

  • Sunmi Kim;Kyounghee Kang;Jiyun Kim;Minju Na;Jiwon Choi
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.2
    • /
    • pp.89-98
    • /
    • 2023
  • Background: Organophosphorus flame retardants (OPFRs) are a group of chemical substances used in building materials and plastic products to suppress or mitigate the combustion of materials. Although OPFRs are generally used in mixed form, information on their mixture toxicity is quite scarce. Objectives: This study aims to elucidate the toxicity and determine the types of interaction (e.g., synergistic, additive, and antagonistic effect) of OPFRs mixtures. Methods: Nine organophosphorus flame retardants, including TEHP (tris(2-ethylhexyl) phosphate) and TDCPP (tris(1,3-dichloro-2-propyl) phosphate), were selected based on indoor dust measurement data in South Korea. Nine OPFRs were exposed to the luminescent bacteria Aliivibrio fischeri for 30 minutes and the human hepatocyte cell line HepG2 for 48 hours. Chemicals with significant toxicity were only used for mixture toxicity tests in HepG2. In addition, the observed ECx values were compared with the predicted toxicity values in the CA (concentration addition) prediction model, and the MDR (model deviation ratio) was calculated to determine the type of interaction. Results: Only four chemicals showed significant toxicity in the luminescent bacteria assays. However, EC50 values were derived for seven out of nine OPFRs in the HepG2 assays. In the HepG2 assays, the highest to lowest EC50 were in the order of the molecular weight of the target chemicals. In the further mixture tests, most binary mixtures show additive interactions except for the two combinations that have TPhP (triphenyl phosphate), i.e., TPhP and TDCPP, and TPhP and TBOEP (tris(2-butoxyethyl) phosphate). Conclusions: Our data shows OPFR mixtures usually have additivity; however, more research is needed to find out the reason for the synergistic effect of TPhP. Also, the mixture experimental dataset can be used as a training and validation set for developing the mixture toxicity prediction model as a further step.

Evaluation on Heating Effects of Geothermal Heat Pump System in Farrowing House (지열 난방시스템을 이용한 분만돈사의 난방효과 분석)

  • Choi, H.C.;Park, Jae-Hong;Song, J.I.;Na, J.C.;Kim, M.J.;Bang, H.T.;Kang, H.G.;Park, S.B.;Chae, H.S.;Suh, O.S.;Yoo, Y.S.;Kim, T.W.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.205-215
    • /
    • 2010
  • Geothermal heat pump system (GHPS) is an energy-efficient technology that use the relatively constant and renewable energy stored in the earth to provide heating and cooling. With the aim of using GHPS as a heating source, it's possibilities of application in farrowing house were examined by measuring environmental assessment and sow's performance. A total of 96 sows were assigned to 2 pig housings (GHPS and conventional housing) with 48 for four weeks in winter season. During the experimental period, indoor maximum temperature in GHPS-housing was measured up to $26.7^{\circ}C$, average temperature could maintain $21.2^{\circ}C$. The mean value of dust levels and $CO_2$, $NH_3$ and $H_2S$ gas emissions were decreased in GHPS-housing compare with those of conventional housing. Litter size, birth weight, parity and weaning weight did not differ between housings. However, feed intake of sow in GHPS-housing was lower than that of conventional housing. In energy consumption for heating, electric power consumption increased in GHPS-housing than the conventional housing, a 2,250 kwh increase, whereas there is no fuel usage for heater in GHPS-housing. Amount of ground water circulated for heating in cold weather for earth heat exchanger was 8.4-12.9 ton per day. In conclusion, GHPS may have environmental benefits and effectiveness of heating in farrowing housing and affect the performance in sows.

Monitoring the Change of Physical Properties of Traditional Dancheong Pigments (전통 단청안료 표면의 물리적 특성 변화 모니터링)

  • Kim, Ji Sun;Jeong, Hye Young;Byun, Doo-Jin;Yoo, Min Jae;Kim, Myoung Nam;Lee, Sun Myung
    • Journal of Conservation Science
    • /
    • v.36 no.6
    • /
    • pp.549-561
    • /
    • 2020
  • This study aimed to assess the performance and life of nine natural mineral dancheong pigments: Seokganju, Jinsa, Hwangto, Jahwang, Wunghwang, Seokrok, Noerok, Seokcheong, and Baekto. The design of the accelerated weathering test considered the domestic climate characteristics and the location of Dancheong. Outdoor weathering tests were conducted at the Research Institute in Daejeon and the Sungnyemun Gate in Seoul to confirm the field reproducibility of the accelerated weathering test. Monitoring of the physical changes in pigments through accelerated and outdoor weathering tests are based on ultraviolet exposure dose. Despite small cracks at the beginning of the tests, the monitoring showed that Seokganju and Baekto had no marked physical changes, but the surface cracks of Jinsa and Seorok continue to expand. Hwangto and Noerok were marked with water or were resin stained, and the particles of Jahwang, Wunghwang, and Seokcheong had lost their luster. Despite the absolute difference in color change in each test, the final chromaticity change patterns of pigments were similar in that the color difference between Baekto and Noerok was below five, and Jina was above 28. The physical and surface color pigment changes were more concentrated in outdoor weathering tests than in accelerated tests, and the Seoul site was more intense than the Daejeon site. This is because outdoor weathering tests are exposed to severe variations of temperature and moisture or deposition of dust particles and, in the case of Seoul, the site is more exposed to the external environment than the Daejeon site.