• Title/Summary/Keyword: Indoor dust

Search Result 240, Processing Time 0.031 seconds

Pilot Study for Difference of Secondhand Smoke Exposure at Smoking and Non-smoking Nightclubs (흡연과 금연 나이트클럽의 간접흡연 노출의 차이에 대한 탐색연구)

  • Guak, Sooyoung;Lee, Boram;Xu, Siyu;Lee, Kiyoung;Lee, Dohoon
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.1
    • /
    • pp.10-16
    • /
    • 2014
  • Objectives: This pilot study assessed secondhand smoke (SHS) exposure in smoking and non-smoking nightclubs in Seoul, Korea by measuring the concentration of particulate matter smaller than $2.5{\mu}m$ ($PM_{2.5}$). Methods: This comparative study was conducted in three nightclubs in Seoul. While one non-smoking nightclub was measured on weekdays and weekends, different smoking nightclubs were measured on weekdays and weekends. The concentration of $PM_{2.5}$ was observed using a real-time monitor over an average of three hours. The number of people in the clubs was also estimated. Settled dust was collected in a smoking and a non-smoking nightclub and analyzed for NNK concentration. Results: The $PM_{2.5}$ concentration in the smoking nightclubs was higher than those found in the non-smoking nightclub by 26 times on weekdays and three times on weekends. Indoor $PM_{2.5}$ concentration was correlated with the number of people in the smoking nightclubs. Relatively high $PM_{2.5}$ concentration was observed in the non-smoking nightclub on weekends. NNK concentration in the smoking nightclub was 7 times higer than in the non-smoking nightclub. Conclusion: Smoking in nightclubs caused high $PM_{2.5}$ concentration. Although the non-smoking nightclub had a lower $PM_{2.5}$ concentration, $PM_{2.5}$ concentration on weekends was higher due to the smoking room. Complete prohibition of smoking in nightclubs can protect patrons from secondhand smoke exposure.

A Study on Health Check Solution using Indoor Air Purifier (실내 내장형 공기순환기를 이용한 헬스 체크 솔루션에 관한 연구)

  • Yang, Hee-Tak;Oh, Ji-Su;Lee, Keun-Ho
    • Journal of Internet of Things and Convergence
    • /
    • v.3 no.1
    • /
    • pp.25-31
    • /
    • 2017
  • In the future a future type new city and the latest apartment will be built, and the IoT technology will be constructed and combined in large numbers indoors of ordinary households. An air cleaner that makes people in it comfortable is built in, and the suction port that sucks in the air of the air purifier and the discharge port that discharges it are set up around the room and come out. However, this is impossible to adjust because there is only a central switch on / off. Also, consuming a lot of electricity so that many electricity charges are caused by huge electricity consumption will eventually be a waste of resources. This would like to be adjusted and driven through the fine dust detection device to the room built-in air purifier and that has provided a solution to save electricity. In addition, since it exists in and around the room, you can grasp the position of the person and connect to the home network to enhance the convenience. Also, through analysis of the air, we provide a health-check solution that checks the user's health and adjusts it appropriately.

Sick Building Syndrome in 130 Underground Workers (지하상가 근무자의 건강 장애에 관한 실태조사)

  • Joo, Ree;SaKong, Joon;Chung, Jong-Hak;Park, Sang-Whan;Kim, Dong-Hee;Kim, Dong-Min;Choi, Eun-Kyong;Cho, Hyun-Geon
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.2
    • /
    • pp.325-340
    • /
    • 1998
  • A cross-sectional study was conducted to evaluate the relationship between sick building syndrome(SBS) and the environmental factors affecting SBS on 130 underground workers and 60 controls. The study consisted of 1) a review of environmental condition 2) measurement of temperature, $O_2$, $CO_2$, CO, and formaldehyde and 3) a questionnaire survey of symptom prevalence and perception of environmental conditions using indoor Air Quality questionnaire recommended by National Institute for Occupational Safety and Health. Bronchitis and dust allergy were more prevalent in underground workers significantly(p < 0.05). Among the 18 symptoms related to the indoor air pollution, the experience rate of dry, itching or irritated eyes, sore or dry throat, chest tightness, tired or strained eyes and dry or itchy skin symptom was significantly different between the underground workers and controls. The diagnostic criteria of SBS was defined as at least 1 symptom is experienced 1-3 times a week during the last 1 month among 18 indoor air pollution related symptoms which can be relieved by moving out of the underground. Applying the criteria, the mean symptom score was significant higher in underground workers than controls significantly (p < 0.05). These resalts indicated that underground workers are under inappropriate ergonomic and physical condition and inadequate ventilation. Their experience rate of symptoms related to indoor air pollution and prevalence of SBS was significantly higher than controls. To reduce the prevalence of SBS of underground workers, the surveillance system of indoor air quality, restriction of using fuel in underground and legislative regulations for the environment are needed to establish a better indoor air quality. Early detection, treatment and prevention of SBS through medical attention is also needed.

  • PDF

Characteristics of Indoor Particulate Matter Concentrations by Size at an Apartment House During Dusty-Day (황사 발생시 아파트 실내에서 미세먼지 크기별 농도 특성)

  • Joo, Sang-Woo;Ji, Jun-Ho
    • Particle and aerosol research
    • /
    • v.15 no.1
    • /
    • pp.37-44
    • /
    • 2019
  • It is recommended for the public to stay at home and to close the doors and windows when a high-particulate-matter environment such as a yellow sand event occurs outside. However, there are lack of empirical studies describing how much outdoor PM infiltrates into a closed house and how much indoor PM an inhabitant is exposed to during the period. In this study, the $PM_{10}$ and $PM_{2.5}$ were measured at the kitchen in an apartment house by an optical particle counter for 3 days including a yellow sand event. The outdoor PMs and the outdoor wind speeds were referred from surrounding weather stations. We analyzed the penetration of $PM_{10-2.5}$ and $PM_{2.5}$ at the test house against the outdoor wind speed supposed corresponding to the change of air exchange rate. In addition, the effect of an indoor activity on change in the indoor PM was investigated. In result, the indoor $PM_{10-2.5}$ was very low even a yellow sand event occurred outside; rather, a contribution of indoor activities to increase in $PM_{10-2.5}$ was higher. In contrast, the indoor $PM_{2.5}$ fluctuated following the outdoor $PM_{2.5}$ trend at high wind speeds or remained almost constant at low wind speed.

Removal Efficiency of PM10 & $CO_2$ in Subway Mock-up Cabin (지하철 목업차량내 객실 공기정화장치의 미세먼지(PM10) 및 $CO_2$ 저감성능평가)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jong-Bum;Cho, Goan-Hyun;Nam, Goong-Seok;Lee, Joo-Yeol;Kim, Tae-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.613-618
    • /
    • 2011
  • More than 7 million persons use Seoul Metropolitan Subways (SMS) everyday and the number has been in increasing trend. With the increasing trend of concerns on indoor air quality(IAQ), the management of IAQ has become an important issue, especially in case of subway operators, because most of subway lines are placed underground with poor ventilation condition. The ultimate object of study develop independent cleaning device that reduce efficient fine particle and $CO_2$. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. Two layered electrically pre-charged filters were used for removing particulate matters and gas absorbers are packed between two layer filters for removing gases pollutants such $CO_2$, VOCs and HCHO. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. SCAP prototype is producted as all in one method which decrease fine dust, $CO_2$ and noxious gas. and basic test carry out with quantity of wind, a gap of pressure, sampling efficiency.

  • PDF

A Systems Engineering Approach to Development of a Worker's Location Monitoring System in Ship and Offshore Plant (선박 및 해양플랜트 환경에서 작업자 위치 모니터링 시스템 개발을 위한 시스템엔지니어링 접근 방법)

  • Park, Jong Hee;Kim, Han June;Yoon, Jae Jun;Kim, Hyoung Min;Hong, Dae Geun
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.16 no.1
    • /
    • pp.68-77
    • /
    • 2020
  • The shipbuilding and offshore industry is a large and complex assembly industry, which causes many safety accidents. The major accidents in the shipbuilding and offshore industry workplaces are stenosis, falling objects, dust, fire, explosions, and gas poisoning. The accident by worker in this industry mainly has three factors: frequent movement, narrow work space, and increased use of subcontractors. To control these factors, it is necessary to monitor the worker's location and work status. In this paper, a worker location monitoring system using inaudible sound wave was designd that can be used in environments with many metal barriers. The process included deriving stakeholder requirements, transforming to system requirements, designing system architecture, and developing prototype. The prototype was validated by third-party testing agency. As a result, it satisfied the designed performance and verified its feasibility.

Deflective Behavior of Charged Particles in a Two-Stage Electrostatic Precipitator

  • Lim, Hun-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.83-91
    • /
    • 2011
  • Even if smoke, fumes, mist or dust particles are removed by electrostatic precipitators (ESPs), the occurrence of ozone, which is harmful to human body, has to be severely restricted in the indoor environments of hospitals, offices, and workshops. Therefore, the two-stage ESP generating positive corona at the ionizer is typically used because it creates less ozone than the two-stage ESP generating negative corona at the ionizer. In order to predict the collection performance and the optimal design of the two-stage ESP applied to positive high-voltage, particle concentration is experimentally investigated in this paper. In addition, particle motion within the collector section is also numerically analyzed. The positive corona discharge current of the ionizer is found to be affected by the applied voltage in the collector section but less so by the particle concentration. Particle concentration shows a minimum near the high voltage electrode of the collector section. The minimum value of the collection efficiency is almost proportional to gas velocity. When the collector length decreases, the minimum value of the collection efficiency increases. Charged particles entering the collector region are linearly deflected towards the grounded plate by an electric field. From the above experimental and numerical results, two empirical equations on the concentration ratio and the collection efficiency are derived, and are in good agreement with the experimental data.

Absorption Characteristics of Perforated Environment Friendly Sound Absorbing Board using Hwangto (황토를 이용한 친환경 유공 흡음보드의 흡음특성)

  • Kim, Sun-Woo;Park, Hyeon Ku
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.3-8
    • /
    • 2011
  • Sound absorbing materials used for lightweight panels and interior material are mainly made of fibroid material such as glass wool or rock wool. However these fiber type sound absorbing materials have some problems such that sound absorption could be decreased as time goes by because of durability. In addition, dust scattering from fiber type material can cause another problem in health. In this point of view, this study aims to develop environment friendly sound absorbing material using Hwangto(so called loess or yellow soil), a traditional housing material. Hwangto is natural housing material in Korea and generally known for improving indoor air quality. Hwangto panel is made to construct on the floor, wall and ceiling, and expected that there is not enough absorption. Present study tried to develop environment friendly sound absorbing material that has high sound absorption performance with good environment performance in terms of air quality. Pore rate was designed to maximize the absorption in the specific frequency bands, and two kinds of backing space were applied in order to see the effect of backing space. As a result peak frequency that has maximum absorption is going high as the pore rate is increased. The backing space provides more absorption and makes the peak frequency down to low.

A Study on cooling technology of electronics communication device consoles using heat pipe exchangers (히트파이프 열교환기를 이용한 전자통신장비 콘솔의 냉각 기술에 관한 연구)

  • Choi, Jee-Hoon;Ryoo, Seong-Ryoul;Sung, Byung-Ho;Lee, Jung-Hwan;Kim, Jong-Man;Chun, Ji-Hwan;Suh, Myung-Won;Kim, Chul-Ju
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.483-486
    • /
    • 2006
  • The fan is widely used to cool high heat flux generated as of the electronic communication device consoles. It, however, makes a lot of noises that interfere considerably with the operation environment. This study was conducted to obtain the cooling design technology of the consoles through being equipped with the Heat Pipe Heat Exchangers (HPHE) together with low revolution fans in place of existing fans for the cooling technology of the forced convection. Not only the sealed type consoles but the HPHE were also designed so as to cool effectively the heat generated from the inside of the console. The simulation was conducted by computational numerical analysis along with its experiments. The results of the numerical analysis and experiments were compared in order to improve the cooling technology of the consoles mounted with the HPHE. Consequently, instead of loud fan noise generated as of existing forced convection methods, the cooling technology of HPHE can remarkably improve many problems such as the operation environment, indoor dust, malfunction caused by pollution sources and so on.

  • PDF

The Preliminary Design and Fabrication of a Daylighting Device with Mini-dish Cluster (자연채광용 Mini-dish 클러스터의 기본설계 및 시제품 제작에 관한 연구)

  • Han, Hyunjoo;Kim, Jeong-Tai
    • KIEAE Journal
    • /
    • v.6 no.4
    • /
    • pp.11-16
    • /
    • 2006
  • This work has carried out some preliminary studies for the utilization of a solar mini-dish system capable of concentrating solar rays to higher densities. A typical mini-dish system considered employs an array of solar mini-dishes where major components are light and compact. It consists of small mini-dishes, optical fiber bundles and diffusers at the end. Each mini-dish (typically has a 20 to 30 cm in diameter) is designed with a simple parabolic profile, concentrating sunlight (after the glass glazing cover to avoid dust deposition on the reflector and facilitate cleaning) onto a centrally-located small mirror which is placed on the bottom side of the transparent glass cover. The focused sunlight is reflected by the mirror surface onto a focal point where the receiving aperture of a homogenizer is located. Optical fibers are used to carry high-density solar rays to the other end where diffusers are mounted for indoor illumination. The proposed high density mini-dish system could make an efficient daylighting system as it excludes large moving parts and expandable if necessary. Each component of the system could be made from the off-the-shelf technology and thus, make the generic unit inexpensive to manufacture. Depending on spatial demand or characteristics, the amount of introducing daylight could be controlled. Preliminary tests have been carried out for a trial system to check any functional problems when in operation. Suggestions are also made to improve the design enhancing its performance and applicability.