• Title/Summary/Keyword: Indoor disaster

Search Result 116, Processing Time 0.019 seconds

Water Jet Experiment of Automatic Fire-tracking Water Cannon Facility combined with Indoor Hydrant Facility in Road Tunnels (도로터널의 옥내소화전설비 겸용 자동화점추적 방수총설비의 방수실험)

  • Kim, Chang-Yong;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.92-98
    • /
    • 2019
  • To determine if water-jet nozzle moves and water jetting are effective according to the location of the fire, this study examined the automatic fire-tracking water cannon system and aan indoor hydrant system, such as water jet centered directivity, water jet range maintainability and water jet shape uniformity. First, an examination to find the center of fire accurately from this system design showed that the water jet centered test was accurate. Second, the water jet range test results showed that when water is jetted at the maximum water jet radius, the water jet shows an inaccurate result but within the allowable tolerance range. Finally, the water-jet shape test result confirmed that there are no problems in setting the block from the algorithm design.

A Research of Field Tolerance for Improvement of Fire Fighting Ability in High Rise Structures (고층건축물에서의 소방력 향상을 위한 현장적응성에 관한 연구)

  • Choi, Tae-Young;Park, Nam-Kwun
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.1
    • /
    • pp.47-55
    • /
    • 2012
  • There are currently various domestic high-rise construction projects underway. Such projects may maximize the economic impact, and yield other benefits, however, there is also a possibility of fire, terrorism, and other disasters that one may not even imagine. This study of high-rise structures' damage reduction measures the fire-fighting ability of the fire fighters at the scene of an indoor emergency upon entry. In order to identify the practical limitations, the fire fighter entered from the 1st floor to reach the top 54th floor. 1.Time required to reach the top floor without the respirator 2.Time required as well as pressure consumption to reach the top floor with the respirator equipped was measured; based on the results, performable range of operations during a fire fighting activity were presented.

A Study on the Friction Loss Reduction in Fire Hoses Used at a Fire Scene (화재현장에서 사용하는 소방호스의 마찰손실 감소 방안에 관한 연구)

  • Min, Se-Hong;Kwon, Yong-Joon
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.52-59
    • /
    • 2013
  • It was described the measured friction loss depending on pressure used and changes in water flow rates for a fire hose used at a fire scene on this study. As a result of actual measurement based on the result obtained by analyzing the use situation of a fire hose such as the kind, quantity, pressure used, etc. of a fire hose, the friction loss in a fire hose under the condition of using by a fire officer at a fire scene was measured as up to 56.8 %. This is much different from the equivalent length of a fire hose used to calculate the pump head in an indoor and outdoor fire-fighting facility. There is no related restrictive regulation on friction loss, there are even no data on friction loss measured by fire hose makers, and spreading a fire hose without considering friction loss at a fire scene can result in an increased length of hose used and a high-pressure water discharge from a fire engine, so this study aims to establish a standard for an equivalent length to friction loss in a fire hose and to propose a spreading method considering friction loss in a fire hose at a fire scene.

A Study on the Combustion Test of Artificial Turf Installed on Field (실외에 설치되는 인조잔디의 연소시험에 관한 연구)

  • Min, Se-Hong;Kim, Yeon-Hwang
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.48-53
    • /
    • 2014
  • In this study, we would evaluate fire risk by domestic standard for artificial turf installed on field and roofs. Today domestic regulation for artificial turf only applies to outdoor uses and especially KS M 3888-1 has compulsion but limited to school athletic facilities. Indoor regulation complying with National Emergency Management Agency (No. 2012-35) was enacted as recommendations. Thus this study did combustion test of artificial turf installed on field. Analyzed result by 45 degree flammability test, standard was inadequate to judge the fire risk so we compared and analysed its characteristic through combustion test of flame retardant finishing carpet used as flooring. Test and assessment result of its ignitionability by 45 degree flammability test showed that carpet was satisfied with flame retardant finishing performance standard contrary to artificial turf. For this reason, by conducting cone calorimeter test, the combustion property after ignition would be analyzed and evaluated and then this study will suggest a countermeasure for strengthening standard.

A Study on the Analysis of Environment Performances in High-Rise Residential Building Through Green Building Certification System (친환경건축물 인증제도 평가를 통한 고층 주거용 건물의 환경성능 분석)

  • Chae, Mun-Byoung;Cha, Min-Chul;Jae, Seong-Ho;Seok, Ho-Tae
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.281-286
    • /
    • 2006
  • In case of Korea, immovable property like location, land prise or investment value is more highly estimated than quality of life of residents for performance and value of apartment house, because of limited land area or high density of population. But the high level of life has recently caused the increasing demand in better life. As there is no cases to provide the house in bulk due to the housing market condition, it is necessary to evaluate performance and value of structure, disaster prevention safety, habitability, antiquated condition of building and equipment, maintenance condition and so on that has importantly influence on resident's life quality. So, this study aims to understand the actual condition of environmental performance for the present apartment by comparing the designated apartment, which is ready to have completed in Daegu, with the mixed use residential building, which gained the best grade for green building certification system. Also by analyzing and evaluating a right to enjoy sunshine, floor impact noise etc. and indoor air quality.

  • PDF

Seamless Routing and Cooperative Localization of Multiple Mobile Robots for Search and Rescue Application

  • Lee, Chang-Eun;Im, Hyun-Ja;Lim, Jeong-Min;Cho, Young-Jo;Sung, Tae-Kyung
    • ETRI Journal
    • /
    • v.37 no.2
    • /
    • pp.262-272
    • /
    • 2015
  • In particular, for a practical mobile robot team to perform such a task as that of carrying out a search and rescue mission in a disaster area, the network connectivity and localization have to be guaranteed even in an environment where the network infrastructure is destroyed or a Global Positioning System is unavailable. This paper proposes the new collective intelligence network management architecture of multiple mobile robots supporting seamless network connectivity and cooperative localization. The proposed architecture includes a resource manager that makes the robots move around and not disconnect from the network link by considering the strength of the network signal and link quality. The location manager in the architecture supports localizing robots seamlessly by finding the relative locations of the robots as they move from a global outdoor environment to a local indoor position. The proposed schemes assuring network connectivity and localization were validated through numerical simulations and applied to a search and rescue robot team.

The Implementation of Information Providing Method System for Indoor Area by using the Immersive Media's Video Information (실감미디어 동영상정보를 이용한 실내 공간 정보 제공 시스템 구현)

  • Lee, Sangyoon;Ahn, Heuihak
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.3
    • /
    • pp.157-166
    • /
    • 2016
  • This paper presents the interior space information using 6D-360 degree immersive media video information. And we implement the augmented reality, which includes a variety of information such as position information, movement information of the specific location in the interior space GPS signal does not reach the position information. Augmented reality containing the 6D-360 degree immersive media video information provides the position information and the three dimensional space image information to identify the exact location of a user in an interior space of a moving object as well as a fixed interior space. This paper constitutes a three dimensional image database based on the 6D-360 degree immersive media video information and provides augmented reality service. Therefore, to map the various information to 6D-360 degree immersive media video information, the user can check the plant in the same environment as the actual. It suggests the augmented reality service for the emergency escape and repair to the passengers and employees.

Design and Implementation of an Ultrasonic Communication Modem for Underwater Sensor Networks (수중 센서네트워크를 위한 초음파 통신 모뎀 설계 및 구현)

  • Byeon, Moo-Kwang;Park, Sung-Joon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.6A
    • /
    • pp.437-444
    • /
    • 2009
  • Underwater sensor networks (USN) for ocean development and disaster prevention have been emerged as one of interesting research topics recently. Since a high-speed and inexpensive communication modem is a prerequisite for deployment of USN, we design and implement an underwater modem by utilizing general-purpose waterproof ultrasonic sensors in this paper. We also make experiments in indoor and outdoor environment with two modems facing each other to conduct a point-to-point communication. According to the experiments, we can achieve the data rates of 1.5 kbps in a water tank and 2 kbps in a pond. Also, the maximum communication distance between two modems is about 30 meters. Besides, we conduct a point-to-multipoint experiment imitating USN by deploying a gateway, a sink node and three sensor nodes in a water tank.

Measuring Inner or Outer Position of Ship Passenger and Detection of Dangerous Situations based LoRa WAN Communication (LoRa WAN 통신 기반의 선박 내/외부 승선자 측위 및 위험상황 감지 시스템)

  • Park, Seok Hyun;Park, Moon Su
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.2
    • /
    • pp.282-292
    • /
    • 2020
  • In order to minimize casualties from marine vessel accidents that occur frequently at home and abroad, it is important to ensure the safety of the passengers aboard the vessel in the event of an accident. There is an EPIRB system as a system for disaster preparedness in the marine situation currently on the market, but there is a problem that the price is very expensive. In order to overcome the cost problem, which is a disadvantage of previous system, LoRaWAN-based communication is used. LoRaWAN communication-based vessel positioning and risk detection system based on LoRaWAN communication transmits measurement data of each module using two Beacon and GPS modules to stably perform position measurement for both indoor and outdoor situations. The rider danger situation detection system can detect the safety status of the rider using the 3-axis acceleration sensor, collect data from the rider positioning system and the rider safety status detection system, and send to server using LoRa communication. When conducting communication experiments in the long-distance maritime situation and actual communication experiments using the implemented system, it was found that the two experiments showed over 90% communication success rate on average.

Comparative Analysis of Flame Retardant Performance of Japanese Cypress Plywood Based on the Main Ingredients of Fire Retardant Paint (도료의 주성분에 따른 편백 합판의 방염성능 비교 분석)

  • Soo-Hee Lim;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.1
    • /
    • pp.61-66
    • /
    • 2023
  • The purpose of this study is to compare and analyze the flame retardant performance of Japanese cypress(Chamaecyparis obtusa) plywood, commonly used in indoor decoration, furniture, and tableware, by treating it with three different fire retardants with different primary ingredients. The experiment was conducted in compliance with Article 31, Paragraph 2 of the Enforcement Decree of the Fire Facilities Installation and Management Act and Articles 4 and 7-2 of the Flame Retardant Performance Standards. After flame time, after glow time, char length, and char area were measured. As a result, first, after flame time was measured at 0 seconds regardless of whether the flame retardant treatment was applied. Second, after glow time was relatively long, measuring 22.7 seconds without treatment, which is likely due to the weak fire resistance and high concentration of carbon monoxide generated by the chemical characteristics of the Japanese cypress itself. Third, it was confirmed that the effects of the primary ingredient, phosphorus, in the flame retardant treatment varied depending on the technological development of the manufacturers of the same species of Japanese cypress plywood. In the future, it is expected that the results of this study will provide fundamental data to select flame retardant treatments that show high flame retardant performance according to the botanical characteristics of the wood.