• 제목/요약/키워드: Indoor Thermal & Air Environment

검색결과 242건 처리시간 0.027초

주거용 건물의 개별 환기시스템 필요성에 관한 연구 (The Individual Heat-recovery ventilation system of Residential Buildings)

  • 신우철;이왕제;윤종호;백남춘
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.99-104
    • /
    • 2014
  • Recently supply of low energy house is increasing which can enhance energy efficiency and indoor environment comfort. Low energy house have to secure air tightness as well as thermal performance so house become high airtightness and inevitably need heat recovery ventilator to enhance indoor air quality. However, most of current ventilation systems are one-click, controlling the entire space so it causes increasing of heating load and fan power which makes it hard to save energy. Thus, Individual Control system is required which can achieve both enhancing indoor air quality and decreasing heating load and electric fan power. Thereby, in this study, we analyzed the correlation between ventilation and fan power through mock-up experiment and measured ventilation load under individual control system. As a result, under the condition of $24^{\circ}C$ of indoor temperature for 6 month(November to April) in Daejeon, ventilation load by fan speed was $10.9{\sim}19.6kWh/m^2{\cdot}a$ when operated 24 hours and $7.6{\sim}13.7kWh/m^2{\cdot}a$ when operated 12 hours in night time. In addition, it is possible to reduce at most 60% of ventilation load under the individual control system; measured ventilation load was $7.4kWh/m^2{\cdot}a$ when operated 24 hours, and $5.5kWh/m^2{\cdot}$ when operated 12 hours in night time.

여름철 도시의 일상생활에서 폭로되는 환경온도와 온냉감 평가 (Thermal Diary - 24 hours' Exposed Temperature and Thermal Comfort in Urban Life, Summer)

  • 이민정;전정윤
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2002년도 추계학술발표대회
    • /
    • pp.333-337
    • /
    • 2002
  • All the outdoor and indoor spaces are connected with each other. The human being moves toward those spaces and experiences temperature fluctuation between the natural and artificial temperature. We conducted an experiment which subjects are the college students wearing the data logger in urban life, and measured 24 hours' exposed temperature and thermal comfort in summer. Results were as follows. 1. Most subjects get weather information(84.6%). Fashion(46.2%) and weather (30.8%) are the reasons to select clothes. They spend their time in indoor environment for 84.92% hours of a day and have an air-conditioner(61.5%) in their houses. 2. Exposed temperature fluctuation were from 33.8$^{\circ}C$ to 15.6$^{\circ}C$. The median value of experienced temperature were 26-27$^{\circ}C$ and average temperature was 26.3$^{\circ}C$. Subjects experienced cold shock of 3.96 times in a day and 67.21% of all evaluated thermal comfort in the range of -1 and 1 by ASHRAE 7 Category Scales. Artificial environment which connected with outside let people experienced temperature fluctuation in wide range.

  • PDF

Comprehensive Field Measurement of Indoor Air and Thermal Quality in Naturally Ventilated Office Building with Double-Skin Façade

  • Ito, Kazuhide;Shiraishi, Yasuyuki
    • 국제초고층학회논문집
    • /
    • 제2권4호
    • /
    • pp.293-314
    • /
    • 2013
  • Double-Skin Façade (DSF), which is a kind of passive indoor environmental control technique, is effective way to control environmental loads while maintaining the transparency especially in perimeter zone and hence the adoption example of DSF keep increasing recently. The objective of this study was to perform a field survey of air quality environment with natural ventilation through DSF and thermal environment within office building with six stories during a mild climate period in Japan. Moreover, to understand the comprehensive environmental performance of the target building, questionnaire survey was conducted to subjectively evaluate the productivity and satisfaction with the environmental factors in office space. In this field measurement, there was a positive correlation between the DSF internal ventilation flow and the amount of solar radiation on the DSF normal surface; the primary driving force for ventilation in the DSF was considered to be the buoyancy force caused by solar radiation. The results of questionnaire survey with regard to productivity level indicated the need for improvement in the thermal (temperature) and spatial environment (room size and furniture placement).

VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) 의 실내환경 적응에 관한 연구 (A Study on the Application of VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) for Indoor Air Environment)

  • 최성우
    • 한국환경과학회지
    • /
    • 제12권12호
    • /
    • pp.1235-1243
    • /
    • 2003
  • Under controlled conditions in an environmental chamber, 24 experiments were performed to compare the ability of a Variable-Air-Volume/Bypass Filtration System(VAV/BPFS) to remove indoor pollutants and to conserve energy with the ability of conventional Variable Air Volume(VAV) system. The specific conclusions of this paper were; first, the VAV/BPFS was more efficient than the VAV system in removing particulate matter, TVOC, and target VOCs. The total effective removal rate of PM for the VAV/BPFS was two times as high as that of the VAV system. The total effective removal rate of TVOC for the VAV/BPFS was 20 percent higher than that of the VAV system. Also each target VOC concentration was reduced by using the VAV/BPFS. Second, clean air delivery rate was increased by using VAV/BPFS due to additional filtration rate. Otherwise, the VAV/BPFS decreased outdoor supply air rate above 25 percent relative to the rate of VAV system. Third, total energy consumption by the VAV/BPFS was lower than that of the VAV system during the period with indoor thermal load, occupied time. The energy saving of the VAV/BPFS ranged from 11 to 16 percent. The VAV/BPFS improves indoor air quality more efficiently than the VAV system, and it reduced energy consumption. Retrofitting the VAV system with the VAV/BPFS was easy The use of VAV/BPFS is, therefore, recommended far buildings with VAV system as well as for buildings at designing stage.

복합문화시설내 공간 구조에 따른 일조와 일사가 실내 온열환경에 미치는 영향 (Effects of Daylight and Solar Radiation on Indoor Thermal Environment According to Space Structures in Multi-Complex Cultural Center)

  • 최병보;전현식;윤석일;김석환;이상진;김수민
    • 설비공학논문집
    • /
    • 제24권11호
    • /
    • pp.751-758
    • /
    • 2012
  • Recently, people are paying attention to new forms of construction. For example, deviated from an enclosed type space, people have been interested in an atrium type and an arcade type spaces. In this study, we had hypothesis 'Indoor thermal environment will be influenced by the inflow rate of natural lights with temperature and humidity.' We selected a multi-complex cultural center and conducted this study. This place is consisted of atrium, arcade, and enclosed types. The three spaces were classified according to the type of spaces that have own features along with their forms. The atrium type space has ceiling and the side windows, and the arcade type space has ceiling windows. On the other hand, there are no windows or open parts in the enclosed type space. Three measurement points at each space were selected because of their huge space. Intensity of illumination, temperature and humidity were confirmed by the average value of three measurement points. In addition, surveys were conducted regarding indoor comfort elements in each space.

벽면 녹화가 실내 온열환경 및 이산화탄소 농도 조절에 미치는 영향 (Effects of Green Wall System Controling Indoor Thermal Environments and Carbon Dioxide)

  • 신정환;김환이;김석환;김수민
    • 한국가구학회지
    • /
    • 제25권2호
    • /
    • pp.148-153
    • /
    • 2014
  • Importance of energy consumptions has being emphasized because of problems of the energy and environment. So, recently, green wall systems have been installed to reduce building energy consumptions. The green wall systems provide several benefits; they make it possible to maintain moderate thermal comforts by greenery. Greening such a surface wall in the building by plants, the temperature of the wall can be properly controlled that purifies the air and improves the view spanning over the space. This study evaluated the effects of green wall systems on reducing room temperature quantitatively, changing of humidity, decreasing of $CO_2$. Test results were confirmed; first, the space installed by green walls showed that temperature and $CO_2$ decreased and humidity was increased. Second, two structures were compared with the solar radiation, and green wall systems controlled the temperature and humidity stably near the wall regardless of the amount solar radiation. In conclusion, the green wall systems can contribute to thermal comforts and indoor air quality in the buildings.

  • PDF

하계 공동주택 하이브리드 환기시스템 적용에 따른 실내공기 및 열 환경 평가 (Analysis of Indoor Air & thermal environment with Hybrid Ventilation system during summer)

  • 김상진;김은수;김태연;이승복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.387-392
    • /
    • 2006
  • The recent on indoor air problem has led to many studies on the methods and effects of ventilation for better indoor air quality. Although natural ventilation is the most effective and energy-saving method in residental housings, the small size of openable window has been a problem in high-rise residential buildings to ventilate only through natural ventilation. Consequently, the installation of mechanical ventilation system has been a requirement in residential buildings, and has caused other problems such as increase of energy consumption and SBS. Hybrid ventilation which uses forces of both natural and mechanical power has been introduced to solve the problem of increase in energy consumption with natural ventilation. In this paper, two types of hybrid ventilation systems in residential building were introduced. One type was with natural ventilation through vent grille in the window, and another type was with natural ventilation through ceiling duct while both types used mechanical ventilation system with the outlets. The indoor temperature distribution and pollution density distribution in summer while operating the ceiling air conditioner were analyzed through CFD simulation. In this paper, the optimal location of diffusers to achieve thermal comfort would be proposed.

  • PDF

A Study on the Evaluation of Air Change Efficiency of Multi-Air-Conditioner Coupled with Ventilation System

  • Kwon, Yong-Il;Han, Hwa-Taik
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권3호
    • /
    • pp.101-107
    • /
    • 2007
  • Indoor air quality becomes of a concern recently in view of human health. This study investigates the air diffusion performance and the air change efficiency of a classroom, when outdoor air is introduced in two different ways in addition to the heating/cooling operation of a ceiling-mounted heat pump. A CFD analysis has been performed to investigate the effect of the discharge angle of the air jets from the heat pump for both parallel and series types of outdoor air system. It is observed that the series type creates more uniform indoor environment compared to the parallel type in general. It can be concluded the discharge angle should not be larger than 40o for the parallel type, in order not to generate thermal stratification in the room.

업무용 빌딩 내 사무실의 실내공기질 평가 (Assessment of Indoor Air Quality in Commercial Office Buildings)

  • 정지연;이병규;피영규
    • 한국산업보건학회지
    • /
    • 제17권1호
    • /
    • pp.31-42
    • /
    • 2007
  • Recently, concerns regarding indoor air quality in offices have continued to increase. Thirty offices in five metropolitan commercial buildings were surveyed from February to April 2004. Sampling was performed during normal business hours. Thermal comfort factors such as temperature and relative humidity, carbon dioxide ($CO_2$), carbon monoxide (CO), formaldehyde (HCHO), respirable dust, $PM_{10}$ were sampled and analyzed to determine the mean, standard deviation, range, and correlation for each of those parameters. The data was then compared to office as standard of Ministry of Labor, and guideline applicable to the indoor environment. The results represented that the temperature was slightly higher than the standard of American Society of Refrigerating and Air-Conditioning Engineers (ASHRAE), the relative humidity was lower that the standard of ASHRAE. The range of the 8-TWA concentration of $CO_2$ was 639 ~ 786 ppm, but 33.3% of the total thirty offices exceeded the 1000 ppm as ceiling concentration. The concentration of CO was less than 3 ppm, which was similar to that of offices in Japanese. The mean concentration of formaldehyde was 0.032 ppm, and only 2 % of total samples (193) exceeded the 0.1 ppm, standard of formaldehyde in office air. The concentration of respirable dust and $PM_{10}$ was not exceeded the standard of those parameters, $150{\mu}g/m^3$. The concentration of those parameters in the office air was statistically correlated.

아파트 실내정원의 겨울철 실내온열환경 조절효과 (Indoor Environmental Efficiency Indoor Garden in Apartment House during Winter)

  • 김정민;최윤정
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.212-216
    • /
    • 2005
  • The purpose of this study is to make clear the indoor thermal environmental efficiency of indoor garden in apartment during winter. The questionnaire survey was carried out during the l0th${\sim}$20th of February 2004, respondents consisted of 215 residents living in a subject apartment estate. The field measurements of indoor thermal elements were carried out at A house with indoor garden and at B house without indoor garden. The measurements in two-subject houses were taken on simultaneously the 11th of February. As Results, the residents living in apartments with indoor garden show positive response on air moisture and satisfaction. The daily ranges of indoor temperature and globe temperature in the A house were narrower than the B house. The average relative humidity in the A house was higher and constant than the B house. Therefore, it was seemed that indoor environment during winter in the house with indoor garden maintained more constant or comfortable than the house without indoor garden by earning effect and humidity control effect of plants.

  • PDF