• Title/Summary/Keyword: Indoor Position

Search Result 529, Processing Time 0.025 seconds

End-to-end-based Wi-Fi RTT network structure design for positioning stabilization (측위 안정화를 위한 End to End 기반의 Wi-Fi RTT 네트워크 구조 설계)

  • Seong, Ju-Hyeon
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.5
    • /
    • pp.676-683
    • /
    • 2021
  • Wi-Fi Round-trip timing (RTT) based location estimation technology estimates the distance between the user and the AP based on the transmission and reception time of the signal. This is because reception instability and signal distortion are greater than that of a Received Signal Strength Indicator (RSSI) based fingerprint in an indoor NLOS environment, resulting in a large position error due to multipath fading. To solve this problem, in this paper, we propose an end-to-end based WiFi Trilateration Net (WTN) that combines neural network-based RTT correction and trilateral positioning network, respectively. The proposed WTN is composed of an RNN-based correction network to improve the RTT distance accuracy and a neural network-based trilateral positioning network for real-time positioning implemented in an end-to-end structure. The proposed network improves learning efficiency by changing the trilateral positioning algorithm, which cannot be learned through differentiation due to mathematical operations, to a neural network. In addition, in order to increase the stability of the TOA based RTT, a correction network is applied in the scanning step to collect reliable distance estimation values from each RTT AP.

To increase positioning accuracy in an IPS environment WPS Search Algorithm Design (IPS 환경에서 위치 정확도를 높이기 위한 WPS 탐색 알고리즘 설계)

  • Lee, Hyoun-Sup;Shim, Man-Taek;Jang, Si-Woong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.75-76
    • /
    • 2022
  • WPS is a system that finds the location of a current moving object through information of a wireless AP. The current location is determined by utilizing the outdoor and indoor AP signal strength characteristics. Even if the map is configured for the first service, the map information of the DB built by the variability of the AP signal cannot be 100% reliable in the case of outdoor. Therefore, various algorithms are needed to increase the accuracy of WPS. This paper proposes a system to increase positioning accuracy by applying various methods to determine the current position of a moving object.

  • PDF

A Study on a utilizing Mobile Mapping System for establishing the High Speed Outdoor Positioning DB based on Field Check Data (정위치 기반 고속 실외 측위 DB 구축을 위한 MMS활용 방안에 관한 연구)

  • Lee, Ha Dong;Lee, Yun;Choi, Yun Soo;Jeong, In Hun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.25 no.2
    • /
    • pp.31-37
    • /
    • 2017
  • Recently, governmental authority and local government are looking for a method of utilizing location information of smart phone for urgent rescue in fire and kidnap situation. Under this background, in this study, a method of rapidly collecting, constructing location determination based Wi-Fi AP data utilizing location information of smart phone and mobile mapping system was suggested in order to construct precise positioning information that could be utilized under urgent situation. By performing compensation work for GPS/INS/DMI through collected outcome, position of collected vehicle was acquired. In addition, source data integrating Wi-Fi information and collected position by coupling based on Wi-Fi AP collector and GPS time was constructed and Wi-Fi radiomap was constructed by removing Wi-Fi signal noise that reduces precise position performance. As a result of performing location determination performance assess ment by selecting 10 test positions by each local government, result value of 25.46cm for total local government average and 27.76m for SD could be obtained. It is considered that this result could be utilized as a technology of being able to supplement or substituting GPS location determination technology that is impossible in plocation determination of mobile communication company's base station (200m~2km) and indoor being used at present.

Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground (지하에 위치한 방사선종양학과에서의 실내공기 질 평가)

  • Kim, Won-Taek;Shin, Yong-Chul;Kang, Dong-Mug;Ki, Yong-Kan;Kim, Dong-Won;Kwon, Byung-Hyun
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.243-252
    • /
    • 2005
  • Purpose: Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. this study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Methods and Materials : Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate. carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor all quality, All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Results: Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritatation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the contaminated-air circulation immediately Conclusion We verified that some IAQ-related factors and inadequate ventilating system could cause subjective symptoms in hospital workers. The evaluation of IAQ was surely needed to improve the underground working environments for hospital workers and patients. On the basis of these data, from now on, we should actively engage in designs of the department of radiation oncology or improvement in environments of the existing facilities.

Performance Evaluation of Several Radon Detectors in the Standard Chamber and Dwellings (라돈 표준실과 가옥 내에서 일부 라돈검출기에 대한 성능 평가)

  • Yoon, Seok-Won;Kim, Yong-Jae;Chang, Byung-Uck;Byun, Jong-In;Yun, Ju-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.4
    • /
    • pp.173-181
    • /
    • 2008
  • To ensure the performance of radon detectors, three passive radon detectors ($RadTrak^{(R)}$, $Radopot^{(R)}$, and $E-PERM^{(R)}$)have been reviewed. The difference ratios of RadTrak and Radopot tested in the radon standard chamber were -13.2% and -6.0%, respectively, which were in good accordance within 20% of the value measured by $AlphaGUARD^{(R)}$. To ensure the performance of the long term measurement, the 3 detectors were installed at the same position of approximately one hundred of dwellings for one year. The correlation curve between RadTrak and Radopot shows good agreement with a correlation coefficient ($R^2$) of 0.91. However, The correlation curve between E-PERM and Radopot shows bad agreement ($R^2$ = 0.021). In addition, the distribution map of annual mean indoor gamma dose rate measured with E-PERM was not in accordance with the distribution map of outdoor gamma dose rate measured by Portable Ion Chamber. According to the results, some requisites for the selection of the radon passive detectors in the large-scale indoor radon survey were discussed.

The Study of Compaction Characteristics of Cataclasite Fill Material using Large and Standard Compaction Tests (대형다짐시험 및 표준다짐시험을 이용한 파쇄암 성토재의 다짐특성 연구)

  • Jeoung, Jae-Hyeung;Ryu, Sang-Hun;Choi, Dong-Yub;Park, Kwang-Sik;Hwang, Sung-Pil
    • The Journal of Engineering Geology
    • /
    • v.26 no.4
    • /
    • pp.439-445
    • /
    • 2016
  • The new airports apply the systematic runway foundation construction to build the high quality runways in order to take the leading position to win future aerial demands and stay ahead of competitors. This study is intended to supplement the weakness of existing standard compaction test to minimize residual settlement of lower weak foundation during operation of passenger berthage. The fill material was sampled from 4 construction sites using the fill material with diameter of 100mm or less, and the standard compacting test (KS F 2312), large circular mold compacting test, and water-replacement field density test (ASTM D 5030) were conducted. The regression analysis of correlation of the field density test and the standard indoor compaction test showed the unreliable value at P-value of 0.05, and the regression analysis of the field density test and the large indoor compaction test showed the high correlation with R value of 0.8878. It is judged that the construction of overall uniform quality can be assured as the site condition is truly reflected only if the compacting test method is selected in consideration of maximum size of fill material when evaluating the maximum dry density used in design and construction.

A System with Efficient Managing and Monitoring for Guidance Device (보행안내 기기의 효과적인 관리 및 모니터링을 위한 시스템)

  • Lee, Jin-Hee;Lee, Eun-Seok;Shin, Byeong-Seok
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.5 no.4
    • /
    • pp.187-194
    • /
    • 2016
  • When performing experiments in indoor and outdoor environment, we need a system that monitors a volunteer to prevent dangerous situations and efficiently manages the data in real time. We developed a guidance device for visually impaired person that guides the user to walk safely to the destination in the previous study. We set a POI (Point of Interest) of a specific location indoors and outdoors and tracks the user's position and navigate the walking path using artificial markers and ZigBee modules as landmark. In addition, we develop path finding algorithm to be used for navigation in the guidance device. In the test bed, the volunteers are exposed to dangerous situations and can be an accident due to malfunction of the device since they are visually impaired person or normal person wearing a eye patch. Therefore the device requires a system that remotely monitors the volunteer wearing guidance device and manages indoor or outdoor a lot of map data. In this paper, we introduce a managing system that monitors the volunteers remotely and handles map data efficiently. We implement a management system which can monitor the volunteer in order to prevent a hazardous situation and effectively manage large amounts of data. In addition, we verified the effectiveness of the proposed system through various experiments.

A Comparative Study on WPS_WS and Traditional Wireless Positioning Systems (WPS_WS기법과 전통적 무선 측위 시스템과의 비교 연구)

  • Lee, Hyoun-Sup;Kim, Jin-Deog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.239-241
    • /
    • 2011
  • Recently, studies on the indoor positioning system in application of wireless AP have been actively going on. The indoor wireless positioning system can be classified into several types according to the positioning techniques. Among them, the fingerprint technique is a technique that establishes the radio map by collecting MAC information of AP and RSSI (Received Signal Strength Indication) before executing positioning and then determines the position in comparison with the information of AP collected during the course of positioning. In the traditional fingerprint techniques, they control and manage by installing APs that are utilized for positioning. However, in case of specific indoors, the management can be done by installing a small number of APs but, in case of wide outdoors, it's practically impossible to install and manage equipments for positioning. In order to solve such problem, there is an improved fingerprint technique that utilizes the APs that are already scattered around. This technique will allow positioning without additional cost, but even the improved fingerprint positioning technique may incur dropped accuracy as well due to wide fluctuation of the AP information. In this paper, the traditional fingerprint technique and the improved fingerprint technique are explained in comparison, and we will compares difference in performance with the proposed WPS_WS (Wi-Fi Positioning System_Weak Signal) technique.

  • PDF

Development of Geocoding and Reverse Geocoding Method Implemented for Street-based Addresses in Korea (우리나라 도로명주소를 활용한 지오코딩 및 역 지오코딩 기법 개발)

  • Seok, Sangmuk;Lee, Jiyeong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.1
    • /
    • pp.33-42
    • /
    • 2016
  • In Korea, the address-point matching technique has been used to provide geocoding services. In fact, this technique brings the high positional accuracy. However, the quality of geocoding result can be limited, since it is significantly affected by data quality. Also, it cannot be used for the 3D address geocoding and the reverse geocoding. In order to alleviate issues, the paper has implemeted proposed geocoding methods, based on street-based addresses matching technique developed by US census bureau, for street-based addresses in Korea. Those proposed geocoding methods are illustrated in two ways; (1) street address-matching method, which of being used for not only 2D addresses representing a single building but also 3D addresses representing indoor space or underground building, and (2) reverse geocoding method, whichas converting a location point to a readable address. The result of street-based address geocoding shows 82.63% match rates, while the result of reverse geocoding shows 98.5% match rates within approximately 1.7(m) the average position error. According to the results, we could conclude that the proposed geocoding techniques enable to provide the LBS(Location Based Service). To develop the geocoding methods, the study has perfoermed by ignoring the parsing algorithms for address standardization as well as the several areas with unusual addresses, such as sub-urban areas or subordinate areas to the roads, etc. In the future, we are planning the improved geocoding methods for considering these cases.

Scan Matching based De-skewing Algorithm for 2D Indoor PCD captured from Mobile Laser Scanning (스캔 매칭 기반 실내 2차원 PCD de-skewing 알고리즘)

  • Kang, Nam-woo;Sa, Se-Won;Ryu, Min Woo;Oh, Sangmin;Lee, Chanwoo;Cho, Hunhee;Park, Insung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.3
    • /
    • pp.40-51
    • /
    • 2021
  • MLS (Mobile Laser Scanning) which is a scanning method done by moving the LiDAR (Light Detection and Ranging) is widely employed to capture indoor PCD (Point Cloud Data) for floor plan generation in the AEC (Architecture, Engineering, and Construction) industry. The movement and rotation of LiDAR in the scanning phase cause deformation (i.e. skew) of PCD and impose a significant impact on quality of output. Thus, a de-skewing method is required to increase the accuracy of geometric representation. De-skewing methods which use position and pose information of LiDAR collected by IMU (Inertial Measurement Unit) have been mainly developed to refine the PCD. However, the existing methods have limitations on de-skewing PCD without IMU. In this study, a novel algorithm for de-skewing 2D PCD captured from MLS without IMU is presented. The algorithm de-skews PCD using scan matching between points captured from adjacent scan positions. Based on the comparison of the deskewed floor plan with the benchmark derived from TLS (Terrestrial Laser Scanning), the performance of proposed algorithm is verified by reducing the average mismatched area 49.82%. The result of this study shows that the accurate floor plan is generated by the de-skewing algorithm without IMU.