• Title/Summary/Keyword: Indoor Parking Lot

Search Result 29, Processing Time 0.021 seconds

The Effect of Ventilation and Concentration of Indoor Air Quality at Indoor Parking Lots (실내주차장의 실내공기질 농도특성 및 환기에 의한 저감효과)

  • Park, Jeong-Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.4
    • /
    • pp.241-247
    • /
    • 2010
  • Recently, indoor air quality (IAQ) has been one of the major concerns of people. Indoor parking lots are subject to be exposed to high concentrations of air pollutants emitted from vehicles. This study was performed to investigate indoor air quality (IAQ) at indoor parking lots. Sampling sites were selected 5 indoor parking lots. Target indoor air quality parameters include a number of criteria pollutants such PM$_{10}$, CO, CO$_2$, and HCHO. In addition, a variation of IAQ according to ventilation system operating was measured at C site (underground parking lot). In general, all pollutants were maintained below indoor air quality maintenance standards. The indoor air quality at indoor parking lots was affected by the availability of the ventilation facility and their operation frequency. At the underground parking lot (C site) with ventilation system, TVOC concentration according to ventilation system operating were found to be lower operating (488.2 ${\mu}g/m^3$) than non-operating (1,401.2 ${\mu}g/m^3$).

A study on the concentration distribution of CO and $CO_2$ by a form of parking lot in the multiplex use facility (다중이용시설의 주차장 형태에 따른 CO, $CO_2$ 의 농도분포에 관한 연구)

  • Sin, Ji-Won;Kim, Tea-Woo;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.316-321
    • /
    • 2006
  • Multiplex use facility emphasized the importance of indoor air environment because many people using that place. People using parking lot of multiplex use facility in little time, but a pollutant of in indoor air menacing user health. This study measure and analyze the CO, $CO_2$ for better air quality of an indoor parking lot in the multiplex user facility. As a result, two-way opened above ground parking lot is higher numerical value of CO, $CO_2$ than an underground parking lot. And a parking lot of square form is higher numerical value of $CO_2$ than a parking lot of rectangle form.

  • PDF

Realtime Vehicle Tracking and Region Detection in Indoor Parking Lot for Intelligent Parking Control (지능형 주차 관제를 위한 실내주차장에서 실시간 차량 추적 및 영역 검출)

  • Yeon, Seungho;Kim, Jaemin
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.418-427
    • /
    • 2016
  • A smart parking management requires to track a vehicle in a indoor parking lot and to detect the place where the vehicle is parked. An advanced parking system watches all space of the parking lot with CCTV cameras. We can use these cameras for vehicles tracking and detection. In order to cover a wide area with a camera, a fisheye lens is used. In this case the shape and size of an moving vehicle vary much with distance and angle to the camera. This makes vehicle detection and tracking difficult. In addition to the fisheye lens, the vehicle headlights also makes vehicle detection and tracking difficult. This paper describes a method of realtime vehicle detection and tracking robust to the harsh situation described above. In each image frame, we update the region of a vehicle and estimate the vehicle movement. First we approximate the shape of a car with a quadrangle and estimate the four sides of the car using multiple histograms of oriented gradient. Second we create a template by applying a distance transform to the car region and estimate the motion of the car with a template matching method.

A Study on Estimation of Ventilation Performance in the Underground Parking Lot (지하 주차장의 환기성능평가에 관한 연구)

  • Hwang, Min-Kyu;Kim, Seong-Sik;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.71-77
    • /
    • 2007
  • In past, parking lot was placed on the ground and for the reason air quality was not in problem. But recently parking lot has been placed under the ground and the air quality becomes problem. So in this study, the ventilation performance on the underground parking lot was estimated by using CFD software and alternative system was suggested. Three case studies are handled in this study. 1st case is just an underground parking lot. 2nd case is about an underground parking lot where has 4 fan rooms on each floor and 3rd case is about an underground parking lot where has 4 fan rooms and 30 guidance fans on each floor.

A Study on the Improvement of Indoor Environment in the Underground Parking Lot of Apartments in Jeonju City (전주시 공동주택 지하주차장의 실내환경 개선에 관한 연구)

  • Jung, Jaeyoun;Jeong, Insoo;Bao, Wei
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.22 no.1
    • /
    • pp.1-12
    • /
    • 2020
  • The main purpose of the research is to prevent residents who are using underground parking lot from being exposed to pollusion, and to allow them to enjoy clean indoor environment. The study subject for the research are underground parking lots in 20 different apartments, 4 of them were constructed before 2000, 10 were constructed from 2000-2010, and the rest were constructed after 2010. By analyzing the air quality in these underground parking lots, we found out that O3, NO2, CO, PM10, Radon in all parking lots were not excessive compared to the standard limit. TVOC rate was measured with the value in between 312 ~ 2,137㎍/m3, with CO2 value in between 193~1,824 ppm, and HCHO with the value in between 0.01~1.52ppm. The lightning system in underground parking lots in apartments constructed before 2000 were using manual light control system, while automatic light control system was used in all apartments constructed after 2000, and the brightness of parking lots in apartments constructed before 2000 was quite low. The apartments constructed after 2000 are performing cleaning and ventilation due to management agreement, while the apartments constructed before 2000 are not performing regular cleaning and there was no mechanical ventilation system installed. The difference of indoor air quality was significant seasonally, daily, and yearly (year of construction), while illuminance was significantly different yearly.

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.

A Strategies to Improve the Natural Ventilation Performance at Underground Parking Lot in Multi-Residential Buildings (공동주택 지하주차장의 자연환기성능 향상방안에 관한 연구)

  • Seo, Jung-Min;Lee, Joong-Hoon;Song, Jong-Eui;Jung, Jung-Hwa;Song, Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.2
    • /
    • pp.153-163
    • /
    • 2011
  • Energy efficiency and indoor air quality have become main issue to develop healthy and sustainable building in these days. As an effort to reduce the energy consumption in multi-residential building, many attempts as like passive design strategies and renewable energy as well as active control method are tried. However, underground parking lot in multi-residential building seldom adopt the sustainable strategies and only mechanical system is installed as usual. Moreover, the mechanical system installed in underground parking lot is rarely operated due to the electric demand for operation after completion. In this study, as an energy efficient measure, natural ventilation system using stack effect as a driving force for underground parking lot will be proposed and the performance of the suggested system will be analyzed by simulation method.

Design of Parking Guidance System using Visible Light Communication with LED Illumination (LED 조명과 가시광 통신을 이용한 주차안내 시스템 설계)

  • Yun, Young-June;Kong, In-Yeup
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.560-562
    • /
    • 2010
  • Nowdays, The LED Illumination system can achieve lower power consumption and has a longer life-time compared to the fluorescent lamp system. Visible Light Communication(VLC) is wireless optical communication to use visible light of LED. This paper designs the indoor navigation of Location-Based Service(LBS) using LED illumination. and the parking guidance system using VLC in the underground parking lot. We show the result of experimentation and confirm possibility of the parking guidance system.

  • PDF

Indoor and Outdoor Formaldehyde Concentrations in Underground Environments (실내외 포름안데히드 농도에 관한 조사연구)

  • 김윤신;김미경
    • Journal of Environmental Health Sciences
    • /
    • v.15 no.2
    • /
    • pp.1-9
    • /
    • 1989
  • A pilot study was conducted in order to measure indoor and outdoor formaldehyde levels during August 3 - 22, 1988 in several underground spaces in Seoul. Formaldehyde concentrations were monitored during 1 week in selected sampling areas (subway station, underground shopping center, underpass, tunnel, underground parking lot) using passive formaldehyde monitors. In order to investigate a relationship between respiratory prevalence and levels of formaldehyde, each subject was asked to answer respiratory questions. The mean formaldehyde concentrations were 60.1 ppb in subway station, 122.2 ppb in underground shopping stores, 72.1 ppb in underpasses, 39.7 ppb in tunnel, and 75.9 ppb in underground parking lots, respectively. The mean indoor formaldehyde concentrations in underground environments varied from 28.6 ppb to 118.7 ppb. Generally, the mean formaldehyde concentrations in ticketing office in subway stations appeared higher than those level measured in platform. The mean formaldehyde concentrations of underground shopping center in Gangnam Terminal were higher than any other areas and it exceeded 100 ppb of the American Ambient Air Quality Standards of formaldehyde. Prevalence rates of respiratory symptoms of dwellers seemed to be related to higher indoor formaldehyde levels.

  • PDF

Research about room air quality of department store underground parking lot (백화점 지하 주차장의 실내 공기질에 관한 연구)

  • Kim Ki-Tae;Yang Sung-Su;Son Bu-Soon;Jeon Young-Taek;Jang Bong-Ki;Lee Jong-Dae
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.44-51
    • /
    • 2006
  • This study was conducted to investigate air quality in the underground parking lot of department store. Sampling sites were selected to the three sites in one department store. Measuring instrument started from November 3rd, 2005 to November 9, 2005. Target air quality parameters include a number of criteria pollutants such as NOx, $O_3$. The purpose of this study was to find out the present condition of indoor air quality in underground parking space of department store. Through the field measurement, the current situation and the behavior of contaminants were investigated and then was compared with the advice standards. The result of this study was as follows; The Average density of NOx gas and $O_3$ gas was maintained below the indoor air advice standards. The Average density of NOx gas and $O_3$ gas was highly measured during the weekend than during the week day. Average density of NOx gas and $O_3$ gas was highly measured at daytime than that of afternoon. Average density of NOx gas was highly measured in the center area than the other area. Average density of $O_3$ gas was highly measured at the entrance than the other area. NOx gas concentration was maintained below 0.3ppm, an average for 1 hours, as defined in the parking space law. $O_3$ gas concentration was maintained below 0.08ppm, an average for 1 hours, as defined in the parking space law.