• Title/Summary/Keyword: Indoor Noise

Search Result 429, Processing Time 0.028 seconds

Evaluation of Acoustic Performance about Dome-typed Gymnastics Training Floor Using Auralization (가청화를 이용한 돔형 체조연습장의 음향 성능평가에 관한 연구)

  • Yun, Jae-Hyun;Ju, Duck-Hoon;Kim, Jae-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.8
    • /
    • pp.708-719
    • /
    • 2007
  • In case of indoor gymnastics training floor, in view of its characteristics, since it is simultaneously required the related smooth communication between the coach and the player, also the acoustic performance regarding to the clearness of music, besides the sport activity, the consideration about the acoustic character has entered the stage as an indispensable element. On such viewpoint, recently constructed dome-typed gymnastic training floor was optimized acoustic design with remodeling through acoustic simulation test. And acoustic satisfaction degree and reaction was attempted to investigate about the gymnastics training floor estimating value of human's psychological(sensual) degree using auralization that enables to experience the virtual sound field at the stage of design. As the result of investigation about the research on the space of object, it could be known that the valuation regarding to the acoustic performance of 'after-improvement' was distinctly more refined than that of 'before-improvement'. It is now considering that such result of the study can be utilized as the useful data which enables to improve the retrenchment effect of the construction cost as well as the acoustic capability, by means of the prediction control on the acoustic problem from the stage of design, for the occasion when the similar indoor sport gymnasium is planning to build for the near future.

Comparison between Indoor Noise Level and Subjective Response for Transportation Noise - Focusing on the Aircraft, Road traffic and Railway Noise (교통소음으로 인한 실내소음레벨과 주관반응 분석 - 항공기, 도로교통 및 철도소음을 중심으로)

  • Park, Hyeon-Ku;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.5 s.122
    • /
    • pp.437-447
    • /
    • 2007
  • A series of research to seek for the relationship between subjective responses and noise level for transportation noise have been proceeded, and their results showed similar for some cases and different for some other cases as well, which is considered due to the various conditions such as the way of survey, different scale applied, and country etc. This study aimed to analyze the relationship between sound level and subjective response for the different kinds of transportation noise. The noises recorded in real situation were played to thirty subjects with fourty nine adjectives. The percentage of people annoyed(% PA) and the percentage of people highly annoyed(% HA) were calculated from the subjective results and compared how many percent of people are annoyed and highly annoyed for the same sound level. As a result of calculating the average, the aircraft noise was highest and the white noise lowest. The relationship between window TL and average point was well correlated except the aircraft noise which was scattered because of high sound level at specific frequency and low TL at corresponding frequency. This means that appropriate rating method for airborne sound transmission should be sought for to evaluate outdoor noise which has different frequency characteristics. The Boltzmann equation for % PA and % HA was applied to predict the sound level corresponding to the percentage. It is concluded that the aircraft noise and road traffic noise have almost same response and the railway noise was same with white noise, used for the reference noise, annoyed lower than other noises about by 3 dB.

Study on Establishment of the Noise Grade Criteria for Household Appliances (가전제품 소음등급 기준설정에 관한 연구)

  • Park, Hyungkyu;Lee, Jaewon;Lee, Wooseok;Han, Jinseok;Gu, Jinhoi
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.12
    • /
    • pp.1237-1242
    • /
    • 2012
  • No matter how low it might be, noise from home appliances in indoor environment cause displeasure for residents as it is produced nearby. Electronic goods including vacuum cleaner and washing machine generate high frequency noise, which interrupts TV-watching or conversations and cause noises between floors in apartment houses. In particular, refrigerators make constant noise late at night, hampering the study for exams and causing sleeplessness. Korea, despite the government's efforts to promote low-noise goods based on the noise test by corporation, there is a lack of standardization in the test method, test condition and measuring equipments. This is a major reason that lowers the reliability of low-noise products. At present, low-noise home appliances are certified with eco labeling in the nation but, only 7 brands of refrigerators, 4 brands of washing machines and 97 brands of air-conditioners obtained certification as of august, 2011. In addition, none of Kimchi-refrigerator and vacuum cleaner brands were approved as low-noise home appliances. This shows Korea's relatively underdeveloped market for low-noise products, which, in part, is because of the difficulties companies face in being certified with eco labeling as they should satisfy various requirements such as power-saving and eco-friendly design besides low-noise features. As a result, low-noise labeling for home appliances should be established for the revised noise and vibration management law and the study was carried out to establish low-noise labeling system for major noise sources including vacuum cleaner, washing machine, air-conditioner and refrigerator.

Development of noise mapping system to manage the interior room noise of power plants (발전소의 실내 소음관리를 위한 소음 매핑 시스템 개발)

  • Kim, Young-Il;Kim, Won-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.1
    • /
    • pp.92-98
    • /
    • 2021
  • The noise management in the interior of the power plant is difficult because the interior is large and the noise level varies greatly from location to location. Therefore, a noise visualization system capable of analyzing the noise distribution is required in order to effectively manage the interior noise. A noise mapping system was developed that can model the inside of the turbine room and create a noise map by measuring the noise level at selected points. And in order to increase the reliability of the model, the model was modified through a method of comparing the noise map and the actual noise measurement results. Facility abnormalities can be determined through regular analysis of noise maps, and a method of effectively managing the interior noise is presented by comparing and analyzing the frequencies and levels of the current and previous noise at a specific point. By using the mapping system, it is possible to establish noise countermeasures that can improve the working environment, check the machine for abnormalities, and increase the reliability of the facility through preventive maintenance.

A sensor controller for map building of home service robot using low cost PSD sensor (저가형 PSD센서를 이용한 홈서비스 로봇의 Map building용 센서 제어시스템)

  • Hyun, Wong-Keun;Lee, Chang-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.10
    • /
    • pp.1897-1904
    • /
    • 2006
  • Home service robot must recognize and build map for indoor and components of the house such as furniture and chair etc. The previous researcher has developed a indoor map building system by using CCD camera and ultra sonic sensor. %no stems have some problem in such a way that (1) a distun resolution can be changed according to the number of pixel when we use a CCD camera system, (2) a measured distance can be decreased when it transmitted to the rubber because of being absorbed the sound energy. This paper represents an intelligent sensor controller of module has been developed by using optic PSD(Position Sensitive Detector) sensor any at a low price. To deduce the switching noise from beam power module and diffused reflection noise, we proposed a heuristic soft filter. The performance of the developed system was compared with ultra sonic sensor system by detecting the indoor wall environment. Some experiments were illustrated for the validity of the developed system.

Vanishing Points Detection in Indoor Scene Using Line Segment Classification (선분분류를 이용한 실내영상의 소실점 추출)

  • Ma, Chaoqing;Gwun, Oubong
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.1-10
    • /
    • 2013
  • This paper proposes a method to detect vanishing points of an indoor scene using line segment classification. Two-stage vanishing points detection is carried out to detect vanishing point in indoor scene efficiently. In the first stage, the method examines whether the image composition is a one-point perspective projection or a two-point one. If it is a two-point perspective projection, a horizontal line through the detected vanishing point is found for line segment classification. In the second stage, the method detects two vanishing points exactly using line segment classification. The method is evaluated by synthetic images and an image DB. In the synthetic image which some noise is added in, vanishing point detection error is under 16 pixels until the percent of the noise to the image becomes 60%. Vanishing points detection ratio by A.Quattoni and A.Torralba's image DB is over 87%.

A Study of Enemy Aptitude of Pistol Sound Source for Space Estimation (공간평가를 위한 피스톨음원의 적정성에 관한 연구)

  • Shon, Jang-Ryul;Kim, Jung-Joong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.3 s.96
    • /
    • pp.320-328
    • /
    • 2005
  • Last target of architectural acoustics is that people wish to convey voice effectively from the space adaptively in use purpose in building. But, how exactly through space sound (sound source) that wish to deliver from indoor can be passed method to do quantification and evaluate quantity of sound by method to serve indoor architectural acoustics estimation summer period and methods to estimate definition propose. This Study searches special quality of sound source about MLS signal that is occurred short-answer sound source (pistol sound source) and nondirectional speaker among indoor sound estimation method, and measure and analyzed reverberation time (RT60), definition (C80, D50) by regulation of each ISO 3382 in age place (classroom, hall, gymnasium). Analysis result and sound factor among could know that d of two sound sources converges in measurement error extent about reverberation time (RT60) of analysis incidental and sound factors and value shows change irregularly about sound factor of D50, C80, pistol sound source judged there is problem. Also, could know that problem is happened in deflection except reverberation time is in deflection analysis with wave that measure each in fixed distance in branch. Finally, when differ size of sound source and measure about change of sound pressure level in case measure sound pressure level giving difference about 10 dB, sound factor could know that there is no different effect.

Performance Analysis of LoRa(Long Range) according to the Distances in Indoor and Outdoor Spaces (실내·외 공간에서 거리에 따른 LoRa(Long Range) 성능 분석)

  • Lim, Junyeong;Lee, Jaemin;Kim, Donghyun;Kim, Jongdeok
    • Journal of KIISE
    • /
    • v.44 no.7
    • /
    • pp.733-741
    • /
    • 2017
  • LPWAN(Low Power Wide Area Network) technology is M2M (Machine to Machine) networking technology for the Internet of Things. The technology is designed to support low-power, long-distance and low-speed communications that are typical of LoRaWAN(Long Range Wide Area Network). To exchange inter-object information using a LoRaWAN, the link performances for various environments must be known. however, active performance analysis research that is based on an empirical environment is nonexistent. Therefore, this paper empirically evaluates the performance of the LoRa (Long Range) link, a physical communication technology of the LoRaWAN for various variables that may affect the link quality in indoor and outdoor environments. To achieve this, a physical performance monitoring system was designed and implemented. A communication experiment environment was subsequently constructed based on the indoor and outdoor conditions. The SNR(Signal to Noise Ratio), RSSI(Received Signal Strength Indication), and the PDR(Packet Delivery Ratio) were evaluated.

An Experimental Study on the Ventilation Characteristics of a Wind-Turbine Natural Ventilator According to the Outdoor-Wind Velocity and the Indoor/Outdoor-Temperature Difference (윈드터빈 자연환기 장치의 외기풍속 및 온도차에 따른 환기특성에 관한 실험연구)

  • Han, Dong-Hun;Kim, Yeong-Sik;Chung, Hanshik;Jeong, Hyomin;Choi, Soon-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.4
    • /
    • pp.175-184
    • /
    • 2017
  • With the improvement of living standards, the ventilation for the mitigation of indoor or outdoor air-pollution problems has recently attracted a lot of attention. Consequently, the ventilation for the supply of outdoor fresh air into a room is treated as an important building-design factor. The ventilation is generally divided into the forced and natural types; here, the former can control the ventilation rate by using mechanical devices, but it has the disadvantages of the equipment costs, maintenance costs, and noise generation, while the latter is applied to most workshops due to the absence of noise and the low installation and maintenance costs. In this experimental study, the ventilation performance of a typical rotating-type natural ventilator, which is called a "wind turbine," was investigated with the outdoor-wind velocity and the indoor/outdoor-temperature difference. From the experiment results, it was confirmed that the temperature difference of $10^{\circ}C$ corresponds to the ventilation driving force with an outdoor-wind velocity of 1.0 m/s. Additionally, the intake-opening area of a building also exerts a great effect on the ventilation rates.

Noise Analysis and Reduction Methods of the All-in One Window Ventilation System (창호일체형 환기장치의 소음분석 및 저감방안)

  • Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.43-55
    • /
    • 2013
  • The window ventilation system based on the heat recovery device was developed which make air ventilation possible without opening the windows. However, mechanical and aerodynamic noises were come to pass which annoyed people in rooms. In the present study, noise of new window ventilation system was measured in both general room and anechoic chamber. Also, the noise path was detected to find cause of noise generation and vulnerable area of the device. Sound absorptive and insulation materials were applied to mitigate the noise. Finally, an alternative noise control method was suggested which can satisfy with the indoor noise standards. As a result, it was shown that the cause of noise was the low transmission loss in the ventilation system. As a result, it was shown that the main noise source of the ventilation system was the blower and the major cause of noise was the low transmission loss of the ventilation system. It is also concluded that the noise levels complies with the noise standards of 40 dBA when 2 mm rubber sheet is applied inside the ventilation system.