• Title/Summary/Keyword: Indoor Environmental Design

Search Result 230, Processing Time 0.023 seconds

Investigation of school building microclimate using advanced energy equipment: Case study

  • Alwetaishi, Mamdooh;Alzaed, Ali;Sonetti, Giulia;Shrahily, Raid;Jalil, Latif
    • Environmental Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.10-20
    • /
    • 2018
  • Buildings are responsible of major energy consumption globally. In addition, they are linked to thermal comfort. The need to provide comfort becomes more crucial in schools as they are the place where students learn, and develop their skills. This research aims to investigate the energy responsiveness of new and traditional school building design, where major variation in form, amount of external walls and glazing are different. The research focused on indoor microclimate condition of selected schools in the city of Jeddah where the climate is hot and humid using advanced tools for monitoring. The research uses advanced energy equipment to measure several aspects such as floor temperature, roof temperature, globe temperature and other factors which can lead to predictable thermal comfort of users. The findings suggest that a larger area of glazing shielded from sunlight has a greater influence on both indoor condition and general thermal sensation. The finding also suggests that the glazing ratio is a major contributor on indoor thermal pattern which can result in an increase in temperature profile between from $7-10^{\circ}C$. The findings of this research can assist in the improvement in the design of the prototype school building in hot and humid climate.

Analysis on Indoor Garden Technology Trends Based on Patent Search

  • Hong, Kwang-pyo;LEE, Hyuk-jae
    • International Journal of Advanced Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.40-48
    • /
    • 2019
  • Indoor gardens tailored to suit individual tastes offer a place to enjoy plants and to relax to city dwellers to relieve stress from city life. However, there are technical issues to build such indoor gardens. To offer solutions to technical issues, this study aims to analyze development phases of indoor garden-related technologies by studying available patents in detail. Also, the study aims to understand current status and future direction of technologies by examining technological trends for introduction of indoor gardens. Brainstorming method was used to understand technology trends and as a result, two groups were identified for technical features of indoor gardens: indoor greening technology and rest area for users. An analysis on selected patents showed that the number of patents increased until 2010 and declined gradually afterwards. Korea ranked the highest in the number of patents grant followed by USA, Japan and Europe. Similar order was observed with the number of patents granted by nationality of applicants. The number of patents granted by nationality was the highest for Korean nationals. For indoor greening technologies, patents related to structure from 2007 were mostly concentrated in the areas of irrigation control and environment control for plants and vegetation. For rest area related technologies, patent related to structure showed a repetitive pattern of increasing and decreasing, but overall, on downtrend. For further development and dissemination of indoor gardening technology, more R&D work is needed with focus on environmental control technology for designing suitable environment for both human and plant.

A Study on Eco-friendly Indoor Space of Domestic Eco-certified (LEED)Building through the Cases Analysis & User's Satisfaction (LEED인증 건축물 분석을 통한 실내공간의 친환경성 개선방안에 관한 연구)

  • Na, Min-Hee;Han, Hae-Ryon
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.5
    • /
    • pp.233-240
    • /
    • 2013
  • The building construction sector has been blamed as the main culprit of environmental contamination worldwide. So, there shall be some constructive alternatives in architectural engineering. As one of the alternatives, the LEED ("Leadership in Energy and Environmental Design") has been introduced since 1990s and has been well recognized in saving the resources and energy. "LEED" has also been introduced in Korea since 2002 but it has not put priority on the eco-friendliness of indoor space. In this study, the international and domestic green systems were analyzed and compared in order to restructure the checklist for indoor space. Using the restructured checklists, the questionnaire were sent to 180 people using 6 office buildings which passed the domestic "LEED" certification. LEED certification system put priority on the air quality and heating/cooling environment in its evaluation section and items. However, according to the results of the study, it was found that the people using the buildings were not satisfied enough with the air environment of buildings along with their other indoor environment items. This shows that even though the office buildings are designed according to the requirements of LEED, the buildings do not meet the occupier's needs. In addition, it showed that the evaluation items should be improved so that they are useful to enhance the satisfaction of the occupiers' needs. The paper could be useful in establishing standard for eco friendliness of indoor space of office buildings which pass the LEED certification as the basic data for increasing energy efficiency and working efficiency of occupiers of the buildings.

A Study of Development of Evaluation on Source Strength and Deposition Constant of VOCs (주택 실내환경 VOCs의 발생량 및 감소량에 관한 연구)

  • Jung, Soon-Won;Yang, Won-Ho;Kim, Dae-Sun;Song, Mi-Ra;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.16 no.9
    • /
    • pp.1019-1026
    • /
    • 2007
  • This study was performed in 30 selected apartments in Seoul, Asan and Daegu area which were constructed within 4 years and over 4 years, to measure the concentration of VOCs(benzene, toluene, xylene) from July, 2004 to September. Mean ratios of indoor to outdoor VOCs concentrations in the construction under 4 years were higher in 1 than average, I/O ratio of over 4 years were lower in 1. This was considered that the VOCs density influences indoor pollutant. For the indoor air quality estimation, the deposition constant and the source strength factor of toluene were $1.49{\pm}2.05\;hr^{-1}\;and\;36.95{\pm}52.26\;ppb/h$, respectively.

Visualization of the Comparison between Airborne Dust Concentration Data of Indoor Rooms on a Building Model (실내 공간별 미세먼지농도 비교 데이터의 시각화)

  • Lee, Sangik;Lee, Jin-Kook
    • Journal of the Korean housing association
    • /
    • v.26 no.4
    • /
    • pp.55-62
    • /
    • 2015
  • The international concern on the inhalable fine dust is continuing to increase. In addition to the toxic properties of the fine dust itself, it can be more dangerous than other environmental factors since the dust pollution is hard to be detected by human sense. Although the information on outdoor air condition can be acquired easily, the indoor dust concentration is another problem because the indoor air condition is influenced by the architectural environment and human activity. It means occupants may be exposed to indoor dust pollution over a long period without being aware. Therefore the indoor dust concentration should be measured separately and visualized as an intuitive information. By visualizing, the indoor dust concentration in each space can be recognized practically in compare with the degree of pollution in adjacent spaces. Besides the visualization outcome can be used as base data for related research such as an analysis of the relation between indoor dust concentration and architectural environment. Meanwhile, with the development of network and micro sensing devices, it became possible to collect wide range of indoor environment data. In this regards, this paper suggests a system for visualization of indoor dust concentration and demonstrates it on an actual space.

An analysis of Noise Conditions in Elementary Schools Located near Airport and Roads (항공 및 도로 교통 소음권내 초등학교의 소음실태분석)

  • Choi Yoon Jung
    • Journal of the Korean Home Economics Association
    • /
    • v.43 no.4 s.206
    • /
    • pp.31-47
    • /
    • 2005
  • This study is a preliminary investigation into improving the environmental quality of schools. The purpose was to clarify the present conditions and reasons of noise in elementary schools located near airports and roads by noise level measurements and questionnaire surveys of subjective responses. fold measurements on equivalent and instantaneous noise levels, indoor and outdoor, were carried out in 3 schools during the periods 11th~ 13th of February and 2nd~ 7th of July,2003. The respondents were 94 teachers working in the 3 schools. The results were as follows. 1) Indoor noise levels of the 3 schools were 36.g~73 dB(A) in winter, and 46.9~ 91 dB(A) in summer. These values were higher than the indoor noise standard of 50 dB(A), except for the average of equivalent noise levels in winter.2) Outdoor noise levels of the schools were 41.1 ~ 101 dB(A) in winter, and 52.4~ 102 dB(A) in summer. These values were generally inappropriate relative to the standard for environmental noise of 65 dB(A). 3) The respondents showed relatively non- positive responses during school hours for interruptions by environmental noise.4) The frequently checked types of environmental noise of the schools were 'airplane noise','surrounding facilities', and 'traffic noise'. The frequently checked types of damage by environmental noise were 'Interrupting school hours' and 'Interrupting business'.

How about the IAQ in Subway Environment and Its Management?

  • Song, Ji-Han;Lee, Hee-Kwan;Kim, Shin-Do;Kim, Dong-Sool
    • Asian Journal of Atmospheric Environment
    • /
    • v.2 no.1
    • /
    • pp.60-67
    • /
    • 2008
  • The spatial limitations of urban environments in general lead to invention and design of a wide range of underground transportation systems such as subways, underground roads and paths, etc. Among them, the application of subway systems in metropolitan cities is most commonly observed to ease those confronted difficulties on this purpose. It in turn leaves passengers and workers to be exposed to indoor air potentially polluted by various sources existing in this underground environment. Specifically when considering the IAQ in a subway station, there exist many IAQ-related parameters to be counted either as individual or as integrated exposures. In this study, a model system has been developed to manage the general IAQ in a subway station. Field survey and $CO_2$ measurements were initially conducted to analyze and understand the relationship between the indoor and outdoor air quality while considering the internal pollution sources such as passengers, subway trains, etc. The measurement data were then employed for the model development with other static information. For the model development, the algorithm of simple continuity was built and applied to model the subway IAQ concerned. In this paper, the recent updated draft version of model developed will be reported and demonstrated.

The Importance and Preference of Eco-Friendly Design Elements Related to Residential Space - Focused on the Residents in Gimhae - (주건공간 관련 친환경 디자인 요소의 중요도와 선호 - 김해지역 아파트 거주자를 대상으로 -)

  • Park, Jin-Kyoung;Oh, Chan-Ohk
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.1
    • /
    • pp.86-94
    • /
    • 2012
  • The purpose of this study was to examine the importance of eco-friendly design elements related to residential space by residents and what element they prefer. To achieve this, 18 eco-friendly design elements related to residential space were selected from the Green Building Certification Criteria and the relevant research papers. These elements were categorized into four areas; the ecological environment area (4 elements), the indoor environmental climate one (4 elements), the energy and resource saving one (6 ones), and the material one(4 ones). On the base of these 18 elements, the importance degree of each element was examined by using 5-point Likert scale. The subjects were 299 housewives living in apartment houses in Jangyu new town, Gimhae. The subjects perceived strongly the importance of eco-friendly design elements, but many of them did not know about Green Building Certification Criteria. Overall importance of 18 elements by the residents was very high. Also, the indoor environmental climate area was considered as the most important one, followed by the energy and resource saving area, the material area, and the ecological environment one.

  • PDF

Management Condition on Indoor Environment and Hygiene of Childcare Center -Focusing on Cheongju- (어린이집 보육공간의 실내환경 및 공간위생 관리실태 - 청주시를 중심으로 -)

  • Choi Yoon-Jung
    • Korean Journal of Human Ecology
    • /
    • v.9 no.2
    • /
    • pp.5-20
    • /
    • 2006
  • This study was a preliminary investigation into improving the environmental and healthy quality of childcare centers. The purpose of this study was to determine the management condition on indoor environment and hygiene of childcare centers in Cheongju. Questionnaire survey was carried out from 11st to 26th of August 2004 by mail. Respondents were consisting of 55 teachers, an executive of each childcare center in Cheongju. From the survey results, there were some problems in 'empty period after remodeling work for preventing sick house syndrome', 'humidity controling', 'glare controling', 'indoor or outdoor noise controling', 'cleaning frequency of each room', 'washing method of toys', 'laundry frequency of rag doll and bedclothes'. So, we need to establish the regulations or give some educations and informations about indoor environment and hygiene to administrators of childcare centers.

  • PDF

Analysis on Indoor Noise Condition of Cafeteria in University Campus (대학교 학생식당의 소음저감을 위한 실내소음 실태분석)

  • Choi, Yoon-Jung;Lee, Seon-A;Kim, Hye-Kyeong
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.05a
    • /
    • pp.85-88
    • /
    • 2007
  • This research is a case study for improving the sound environmental quality of cafeteria in university campus. The purpose of the study is to investigate the present condition of physical level, type, and source of indoor noise by comparison with a restaurant near campus. Methods were field survey with measurement on equivalent and instant noise level and observation on noise type, and questionnaire survey to 60 students users. Surveys were carried out in the 8th and the 14th of December 2005. The results are as follows. 1) Indoor noise levels of the cafeteria were measured as $67.2{\sim}76.6$(average 73.3) dB(A)Leq5min and $60.3{\sim}90.5$(average 71.2) dB(A), but noise levels of the restaurant were $61.6{\sim}70.4$(average 66.9) dB(A)Leq5min and $59.8{\sim}70.6$(average 64.9) dB(A). 2) The users's responses on major noise type were 'noise by handling equipment and tableware', 'noise by moving chairs', and 'taking noise' in cafeteria, but 'taking noise' and 'background music' in restaurant. 3) It was found that the differences of indoor noise condition between with 2 subjects were caused by finishing materials, kitchen division type, and furniture type.

  • PDF