• Title/Summary/Keyword: Indoor Environment Monitoring

Search Result 149, Processing Time 0.022 seconds

Indoor Air Pollution of a High-rise Apartment Caused by Combustion Sources in Winter (겨울철 연소오염원에 의한 도심 고층 아파트의 실내공기오염)

  • Kim, Jong Bum;Lee, Gwangjae;Ryu, Sung Hee;Lee, Jae Young;Woo, Sung-Ho;Lee, Seung-Bok;Kim, Kyung Hwan;Yun, Seong-Taek;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.10 no.3
    • /
    • pp.119-130
    • /
    • 2014
  • Home is a major living environment of children. In urban area, indoor air at home could be severely influenced by combustion sources such as vehicle exhaust and cooking. In this work, the air quality of a high-rise apartment was investigated by monitoring combustion-related air pollutants at both indoor and outdoor in winter of 2014. From 48-h continuous monitoring data, large amount of $NO_x$ was observed at the balcony of the high-rise apartment during the morning traffic hours. It deteriorated indoor air quality of the apartment. During the cooking activity, high peak episodes of ultrafine particles were seen. It was concluded that effects of vehicle exhaust and cooking activity on the indoor air of the high-rise apartment could be easily checked by $NO_x$ and ultrafine particle indicators, respectively.

Design and Development of Remote Monitoring System for Confirmation of Indoor Environment (실내 환경 확인을 위한 원격 모니터링 시스템의 설계 및 개발)

  • Lee, Keonha;Kim, Suyeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.5-8
    • /
    • 2019
  • Recently, we have been demanding the comfort of the indoor environment due to environmental problems such as fine dust and yellow dust. In addition it is pursuing the most pleasant indoor environment for humans. In this study, we designed and implemented monitoring systems and mobile applications to enable information such as room temperature and humidity. Open source software and open source hardware are required to design and implement the systems proposed in this study. In this study, the systems implemented used a bluetooth module, a light sensor, and a temperature and humidity sensor. In the future, we expect to be a basic study of systems that can operate dehumidifiers, warm-air fans, fans and humidifiers using motors and optimize indoor environment.

  • PDF

DEVELOPMENT OF A MOBULAR ENVIRONMENT MONITORING SYSTEM FOR GREENIIOUSE

  • Ryu, K.H.;Kim, H.J.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.1081-1089
    • /
    • 1996
  • In Korean agriculture, an automatic environment control system for greenhouse is essential to save labor and to increase the quality of products. The existing environment monitoring systems have weighed on greenhouse growers and researchers because of their high cost and difficult applications. Many sensors are widely used for monitoring the greenhouse environment, but most of commercial sensors are expensive and not suitable for use in greenhouses. Thus , the development of an environment monitoring system for exclusive use in greenhouses is essential . The objective of this study was to develop modular environment monitoring systems, which are low-cost , reliable and easy -to -use. The results showed that the sensors for indoor and outdoor environments and nutrient solution had the ranges and accuracies appropriate for use in greenhouses. Also the modular environment systems developed showed a satisfactory performance in terms of stability and reliability in the measurement and acquisition of the greenhouse environment data.

  • PDF

Development of an Indoor Networked Security Robot System (네트워크 기반 실내 감시 로봇 시스템 개발)

  • Park, Keun Young;Heo, Guen Sub;Lee, Sang Ryong;Lee, Choon Young
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.3 no.3
    • /
    • pp.136-142
    • /
    • 2008
  • Mobile robots can offer services like intelligent monitoring in an indoor environment using network connection with remote users. In this paper, we designed and developed a networked security robot system with various sensors, such as flame detector, gas detector, sound monitoring module, and temperature sensor, etc. The robot can be accessed through a web service and the user can check the status of the environment. Using ADAMS software, we defined the motor specification for a worst-case condition of climbing over a obstacle. We applied the robot system in monitoring office condition.

  • PDF

Multi-Modal Sensing M2M Healthcare Service in WSN

  • Chung, Wan-Young
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.4
    • /
    • pp.1090-1105
    • /
    • 2012
  • A multi-modal sensing M2M healthcare monitoring system for the continuous monitoring of patients under their natural physiological states or elderly persons with chronic diseases is summarized. The system is designed for homecare or the monitoring of the elderly who live in country side or small rest home without enough support from caregivers or doctors, instead of patient monitoring in big hospital environment. Further insights into the natural cause and progression of diseases are afforded by context-aware sensing, which includes the use of accelerometers to monitor patient activities, or by location-aware indoor tracking based on ultrasonic and RF sensing. Moreover, indoor location tracking provides information about the location of patients in their physical environment and helps the caregiver in the provision of appropriate support.

The Influence of Air Pollution Level on Resident's Evaluation and Cognition for Indoor Environment in Ulsan (울산지역의 대기오염 환경의 차이가 거주자의 실내환경 평가 및 인식에 미치는 영향)

  • Yoo, Bok-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.3
    • /
    • pp.87-94
    • /
    • 2010
  • The aim of this study was to evaluate the influence of air pollution level in industrial and residential district of Ulsan on resident's evaluation and cognition for indoor environment. The evaluation of air pollution materials (as $SO_2$, $NO_2$, $O_3$, CO, PM10) were investigated to understand the distributional characteristics in survey area, and air quality monitoring data from 2007 to 2009 were used. The data was applied in a realtime measurement of industrial and residential area respected to difference of the pollution level in Ulsan. The questionnaire of this survey for resident's cognition was to find out characteristics on perception of indoor environment and outdoor air quality recognition based on the distinct characteristics of the areas. The results of this study shows that resident's satisfaction at clean level outdoor air and indoor environment were different whether it was residential area or industrial area and outdoor air pollution level has direct influence on resident's satisfaction in indoor environment.

Historical Data on Indoor and Outdoor Air Quality in Seoul, Korea (1980년대 초 서울의 실내외 대기질 수준 - Sherwood 교수의 측정 자료 활용)

  • Lee, Kiyoung;Sherwood, R. Jerry
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.1
    • /
    • pp.99-103
    • /
    • 2013
  • Objectives: This paper was prepared in memory of Jerry Sherwood, who provided a significant contribution to the Korean environmental and occupational health fields. Methods: Rare air quality data in Seoul were gathered by Jerry Sherwood when he visited Korea in the early 1980s. $SO_2$ and TPM concentrations were measured. These air quality measurements were based on ambient stationary monitoring and indoor air quality monitoring in various locations. Measurement during transportation was also applied. Results: Ambient $SO_2$ and TPM concentrations in Seoul were very high in the early 1980s. Ambient $SO_2$ concentrations were higher at nighttime. While ambient $SO_2$ concentrations varied by location, the Guro industrial area showed high levels. When indoor sources were presented, indoor $SO_2$ concentration was higher than outdoor level. Coal briquettes were closely associated with high indoor $SO_2$ concentration. Conclusion: This paper provided valuable historical information of air quality in Seoul.

Implement of Analysis system with Indoor Environment Monitoring Based on IoT (사물인터넷 기반 실내 환경 모니터링 분석 시스템 구현)

  • Nam, Jae-hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.12
    • /
    • pp.1687-1692
    • /
    • 2019
  • In the era of the fourth industrial revolution, advanced technologies such as the Internet of Things(IoT) and big data are emerging. However, the level of application of IoT to indoor environment is very weak. Therefore, it is necessary to develop a system for analyzing air pollutants or indoor air quality through real-time monitoring using the IoT. This paper implements a system that measures indoor environmental values using Arduino and various sensors, and stores the information obtained from various sensors into a database of server. The information stored in the server was built as a database and utilized in the ventilation system or air cleaner installed in the home or company's room. In the proposed system, it is possible to check the immediate indoor environmental condition through the LED status display of the monitoring sensor module while reducing the cost of the sensor used to implement IoT technology.

Real-time Air Quality Monitoring System Based on Wireless Network (무선네트워크기반 공기질 실시간 모니터링 시스템)

  • Paik, Seung Hyun;Lee, Jun Yeong;Jung, Sang Woo;Park, Hong Bae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.11 no.3
    • /
    • pp.143-151
    • /
    • 2016
  • In this paper, a real-time air quality monitoring system based on wireless network is designed and implemented for industrial park or multiuse facilities. The existing gas detector is high price and hard to apply the remote monitoring system. On the other hand, demand for air quality monitoring is increasing because of industrial gas accident, air pollution, and so on. In Korea, indoor air regulation was established by law. According to indoor air regulation, CO2, CO, and NO2 are important gases as the air quality standard. So we study the gas detector for indoor air quality and the wireless network system. The wireless network consist of sensor network and WCDMA to apply various place. To verify the performance of the implemented gas detector, the gas measurement experiment is performed in laboratory environment by using the realized gas detecting wireless sensor node. And we evaluate the experiment results.

Comparison of the Difference in Response Time According to the Server Configuration Type of the Indoor Air Quality Improvement System (실내공기질 개선 시스템의 서버 구성 방식에 따른 응답 시간의 차이 비교)

  • Joongjin Kook
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.1
    • /
    • pp.59-63
    • /
    • 2023
  • Various devices have been emerging as a means of measuring indoor air quality, and among them, there are devices that support real-time remote monitoring through IoT technology and a cloud environment. To improve indoor air quality, based on the results determined by measuring devices, air purifiers or ventilation systems may need to be operated, and temperature and humidity control may be required. In this paper, we propose a design of indoor air quality measuring devices required for indoor air quality evaluation, and of the system needed to control relevant devices to improve indoor air quality through the interaction with the measuring devices. Currently, the servers for the interaction of indoor air quality devices and IoT devices are divided into conventional server type and serverless type, comparing the differences in response time of IoT devices to changes of indoor air quality.

  • PDF