• Title/Summary/Keyword: Indoor Atmosphere

검색결과 78건 처리시간 0.031초

Monitoring of air Pollution on the Premises of the Factory Sharrcem - L.L.C

  • Luzha, Ibush;Shabani, Milazim;Baftiu, Naim
    • International Journal of Computer Science & Network Security
    • /
    • 제22권10호
    • /
    • pp.214-222
    • /
    • 2022
  • In these proceedings, we will address the problem of air pollution on the premises of the Cement factory SHARRCEM L.L.C. in Hani Elezit in the Republic of Kosovo respectively around the clinker cooler, rotary kiln, and raw material mill. By air pollution, we mean the introduction of chemicals, particles, or other harmful materials into the atmosphere which in one way or another causing damage to the development of plants and organisms. Air pollution occurs when certain substances are released into the air, which depending on the quantitative level, can be harmful to human health, animals, and the environment in general. The analysis of air shows the influence of the extractive and processing industry on the chemical composition of air. Parameters analyzed though under control such as the case of carbon dioxide, due to the increasing production capacity of cement, the production of hundreds of thousands of cubic meters of CO2 gas made CO2 production a concern. With the purchase of the latest technology by the SHARCEM Factory in Hani Elezit, the amount of air pollution has been reduced and the allowed parameters of environmental pollution have been kept under control. Air pollutants are introduced into the atmosphere from various sources which change the composition of the atmosphere and affect the biotic environment.The concentration of air pollutants depends not only on the quantities that are emitted from the sources of air pollution but also on the ability of the atmosphere to absorb or disperse these emissions. Sources of air pollutants include vehicles, industry, indoor sources, and natural resources. There are some natural pollutants, such as natural fog, particles from volcanic eruptions, pollen grains, bacteria, and so on.

KOH 활성화처리된 메조기공 탄소를 이용한 실내 포름알데히드 제거 (Removal of Indoor Formaldehyde Using Mesoporous Carbon Activated with KOH)

  • 유미진;박성훈;전종기;박영권
    • 공업화학
    • /
    • 제23권1호
    • /
    • pp.42-46
    • /
    • 2012
  • 본 연구에서는 메조기공 탄소(CMK-3)를 KOH로 활성화 하여 실내공기 오염물질인 포름알데히드 흡착에 사용하였다. 활성화는 KOH 처리한 CMK-3를 $700^{\circ}C$의 반응기에서 질소분위기로 수행하였다. 활성화된 시료의 특성은 BET, XRD, XPS, FT-IR을 통해 분석하였다. 포름알데히드의 흡착능은 활성화에 의해 향상되었으며, 이는 활성화에 의해 메조기공 탄소의 산소작용기와 질소 작용기의 생성에 기인하는 것으로 판단된다.

대학도서관 실내 공기질 측정 및 조사 연구 (A Study on the Measurement and Investigation of Air Quality in a University Library)

  • 이재원
    • 한국도서관정보학회지
    • /
    • 제50권4호
    • /
    • pp.635-658
    • /
    • 2019
  • 본 연구에서는 S대학 중앙도서관을 대상으로 측정 유해인자를 ① 공기 중 유해물질 ② 생물학적 유해인자 ③ 일산화탄소·이산화탄소·이산화질소 농도로 구분하여 관련 기준과 비교하여 측정·분석하였다. 분석한 결과 공기 중 유해물질인 미세먼지, 석면, 휘발성 유기화합물, 포름알데히드 모두 관련 기준 보다 낮은 수준으로 나타났으며, 생물학적 유해인자인 공기 중 곰팡이, 그람음성박테리아, 엔도톡신 등도 특별한 문제를 찾을 수 없었다. 공기 중 일산화탄소, 이산화탄소, 이산화질소 농도도 일반 대기 중의 농도 대비 특이한 점이 없이 유지되고 있었다. 다만, 도서관은 다중이용시설로 주기적인 청소와 환기를 통한 환경 관리가 필요한 것으로 나타났다.

조선소 주변지역에서 휘발성유기화합물 및 알데히드류의 농도분포 특성 (Characteristics of Atmospheric Concentrations of Volatile Organic Compounds and Aldehydes for Near a Shipyard)

  • 박정호;서정민;한성종
    • 한국환경과학회지
    • /
    • 제17권7호
    • /
    • pp.767-774
    • /
    • 2008
  • This study was carried out to evaluate the characteristics of atmospheric concentrations of volatile organic compounds(VOCs) and aldehydes for near a large shipyard. Most of the painting work in marine coating is performed indoor and outdoor. Most of the VOCs are emitted to the atmosphere as the paint is applied and cures. The massive scale of a ship makes it difficult to capture the emissions from outdoor painting. The VOCs are an important health and contributors to photochemical smog. The VOCs and aldehydes samples were collected using adsorbent tube and 2,4-DNPH cartridge, and were determined by an automatic thermal desorption coupled with GC/MS and HPLC-UV analysis, respectively. A total of 16 aromatic VOCs and 12 aldehydes of environmental concern were determined. At indoor coating facilities, the most abundant compound among 16 target VOCs appeared to be m,p-xylene, being followed by o-xylene. But most of the aldehydes were extremely lower concentrations. The atmospheric concentration of VOCs, m,p-xylene concentrations were the highest and the mean value were outdoor workshop 11.323 ppb, residental area 5.134 ppb, and green area 2.137 ppb, respectively. However, the most aldehydes were extremely lower concentrations such as formaldehyde, acetaldehyde and non-detection such as iso-valeraldehyde, n-valeraldehyde and o-tolualdehyde.

군 소화기 사격장 소음측정 및 소음저감 방안 평가 (Measurement of Noise and Evaluation of Noise Control Methods for Military Rifle Shooting Ranges)

  • 이상우;김희석;정상조
    • 한국군사과학기술학회지
    • /
    • 제12권1호
    • /
    • pp.123-132
    • /
    • 2009
  • Civil petitions and law suits against the military rifle shooting noise have been increased because many military shooting ranges are located near civilian residential area. In order to solve the noise problems, military have devised various methods. In this study, propagation properties of rifle shot through atmosphere were investigated. The military rifle shooting noise level at 5m from muzzle was between $l14{\sim}120dB$ in all directions. The noise level loom both backward and sideward away from system firing range consisting lines of 8 shooting locations were 90dB, when shots were all fired within 10 seconds. At present some of military bases established sound barriers, muzzle enclosures, silencers, and indoor shooting ranges to reduce noises and these prevention methods can reduce noise by $5{\sim}20dB,\;5{\sim}9dB,\;5{\sim}13dB,\;40{\sim}50dB$, respectively. Even though indoor shooting range has the best performance, it requires very expensive construction cost and has short length between target and shooter. In comparison, muzzle enclosure is cheap, but because it is installed in fixed position it can only be used in one shooting position. Therefore a commander should select appropriate methods to reduce military rifle shooting noise considering distance from residential area to the range, mission of military training, budget, etc.

청정에너지 회수용 유증기/매연 포집모듈에 관한 연구 (A Study on the Oil-mist/Smoke Collecting Module for the Pure Energy Recycling)

  • 김명수;오꾸라 시게노부;함경춘
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.279-284
    • /
    • 2009
  • Traditionally, so-called "industrial waste gases", such ad exhaust from boilers at industrial installations and a large quantity of soot discharged from power station, before their release into the atmosphere, have been on occasion subjected to an air cleaning process to remove fine particles that may pollute the atmosphere (such as mist and dust containing various powdery or oily substances and moisture from industrial waste gases). The release of industrial waste gases containing these particles directly into the atmosphere poses a serious threat to the earth environment; and recovery of these noxious substances is required by law in some countries and local governments. in urban areas, air pollution from automobile exhaust and others creates a serious condition. Some homes are equipped with and use indoor air purifiers. In many of the kitchens of restaurants, smoke generated during cooking and otherwise contaminated air are cleansed by air purifiers before being released outside or recycled inside. For the dust collecting devices to recover the fine particles contained in contaminated air, the cause for air pollution and how to purify air, many types based on various principles are known. Specifically, classified based on theories of particle collection, filtration, gravity, inertia, centrifugation, electricity, and cleaning types are cited as available processes. Among them, an appropriate type is selected according to the size or type of fine particles to be collected and conditions for installation. For the efficiency of dust collection, a filtration system (by using bag filters and others) and electric system are particularly outstanding and are therefore used widely in various areas of industry. In this research, rotary type high performance oil mist and smoke collecting system with self auto cleaning device equipped with the cleaning fluid spraying section is investigated.

  • PDF

후각센서 사용에 의한 콘크리트 구조물의 품질평가에 관한 기초적 연구 (Basic Study on Quality Assurance of Concrete Structure by using Odor Sensor)

  • 시로카도 요시츠구;카가야 마코또;이상훈
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2010년도 정기 학술발표대회
    • /
    • pp.42-42
    • /
    • 2010
  • In order to assure the quality of concrete structure in construction process, the odor strength measured by using odor sensor was used to evaluate curing effect. Then, the compressive strength and odor strength in ordinary concrete N were shown in water curing(=standard curing), indoor and outdoor atmospheric curing condition. The difference between odor strength in the standard curing and that in each curing condition was defined as the difference in the odor strength. And the difference in odor strength in slag powder concrete BP cured in water curing(=standard curing) for different period before exposing in outdoor atmosphere in winter season were evaluated at the age of 14 days. A necessity to prolong the moisture curing for the slag powder concrete BP compared with the ordinary concrete N to obtain a required curing effect was shown by measuring the odor strength and long term compressive strength.

  • PDF

Efficient removal of toluene by $TiO_2$ films on carbon paper

  • Seo, Hyun-Ook;Kim, Kwang-Dae;Tai, Wei Sheng;Kim, Myoung-Joo;Luo, Yuan;Kim, Young-Dok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.346-346
    • /
    • 2010
  • Using a novel deposition technique, which can be described as pulsed chemical vapor deposition (CVD), $TiO_2$ thin films were synthesized on carbon fibers. We show that these films exhibit extraordinary high absorption capacities of toluene vapor. Such an absorption phenomenon of toluene at room temperature was not found for other $TiO_2$ samples. We expect that $TiO_2$ thin films prepared here can be used for removing volatile organic compounds from indoor atmosphere. Structures of there $TiO_2$ films were studied by SEM and XPS, and the results are discussed.

  • PDF

해외 친환경 병원 인증기준 고찰 : 미국, 영국, 호주를 중심으로 (Accreditation Criteria of Environmentally-Friendly Hospitals in the USA, UK and Australia)

  • 강정규;서영준;박현숙
    • 보건행정학회지
    • /
    • 제20권4호
    • /
    • pp.139-169
    • /
    • 2010
  • The purpose of this study is to compare accreditation criteria of environmentally-friendly hospitals in the USA, UK and Australia and find out the implications for Korean hospitals. The comparison was made in terms of 11 categories : sustainable site, water efficiency, energy & atmosphere, transportation, indoor environmental quality, health, material & resources, management, waste, innovation, and regional priority. Literature review of the study revealed that most of the environmentally-friendly hospitals have experienced such positive effects as cost saving, health promotion of patients & employees and good reputation etc. The study result implies that the following factors are so critical to settle environmentally-friendly hospitals in Korea: 1) CEO's interest & support, 2) education for employees, 3) efficient renovation of existing facility and 4) data accumulation on the effectiveness of environmentally- friendly hospitals by scientific methods.

Trend Analysis of LEED Certifications: Insights and Future

  • Lee, SeungMin;Kwak, Young Hoon
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.1009-1016
    • /
    • 2022
  • As environmental concerns grow, people are becoming more aware of energy efficiency, carbon reduction, and sustainable development. Leadership in Energy and Environmental Design (LEED) certification is currently the most widely recognized building environment assessment method connected to energy and the environment worldwide. This study explores trends for six factors (energy and atmosphere, materials and resources, indoor environmental quality, sustainable sites, water efficiency, and innovation in design) to assess four levels of LEED certification (Platinum, gold, silver, and certified) using 11,209 LEED projects in the United States. The study analyzes trends using scores of percentages of maximum points by certification level, ownership type, space type, and climate zones. With the interest in the Environmental, Social, and Governance (ESG) principle on the rise, this study contributes to a better understanding of the trends and future of LEED certification in the built environment sector.

  • PDF