• Title/Summary/Keyword: Indoor Air quality

Search Result 1,019, Processing Time 0.044 seconds

A Subjective Symptom Level and Satisfaction Factor by Indoor Air Quality According to Ventilation System in Dental Clinic (치과병·의원 환기방법에 따른 실내공기질 자각증상 수준 및 근무환경 만족요인)

  • Choi, Mi-Suk;Ji, Dong-Ha;Choi, Jae-Ho
    • Journal of dental hygiene science
    • /
    • v.11 no.4
    • /
    • pp.353-359
    • /
    • 2011
  • This study was designed to identify a subjective symptom level by Indoor air according to ventilation system in Dental Clinic. The number of respondents was 582 who work in dental clinic and period of investigation was October 2010 through January 2011. A structured questionnaire was employed to evaluate the level of participants' sociodemographics, job-related factors, work place condition, a subjective symptom. Most of respondents were answered that time for symptom to begin was at around 2 P.M. and time for symptom to feel serve pain was at around 3 P.M. and ventilation frequency per a day was often in case of individual cooling and heating system. More often natural ventilation and in case of individual cooling and heating system, the level of subject symptom was low and multiple regression analysis has found that indoor air quality related elements were main factors that influence to the feeling of satisfaction in work place. The results of this study suggest that more often natural ventilation was very important to reduce the level of subjective symptom. Thus, a management program for indoor air quality is strongly recommended by natural ventilation, maintenance man for promotion of quality of life in dental hygienist and to improve dental service and competitiveness.

The Variation of Indoor Air Quality in Nursing Home

  • Ji, Dong-Ha;Choi, Mi-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.1
    • /
    • pp.117-124
    • /
    • 2020
  • In this paper, we proposed a plan to maintain comfortable indoor air quality in nursing homes by suggesting ways to reduce items temporarily exceeding the reference values through real-time concentration variation analysis of indoor air quality. Five items including PM10, CO2, CO, VOC, and Radon are measured at nursing homes in spring (April) and autumn (September) was carried out and all of the measured items were analyzed to satisfy the criteria set by the Indoor Air Quality Control Act. As a result of the analysis of the real-time concentration change, the concentration of CO2 was close to the reference value based on the number of occupants in the sick room. Due to the disinfectant (alcohol) used to disinfect and the auxiliary tools (adhesive) used in the operation of the program such as making and coloring, it was analyzed to temporarily exceed the standard value in the hall. In conclusion, it is possible to provide pleasant indoor air quality and contribute to securing the nursing home's competitiveness if periodic ventilation, natural disinfectant and eco-friendly product are used in consideration of the thermal environment.

Assessment of indoor air micro-flora in selected schools

  • Katiyar, Vinita
    • Advances in environmental research
    • /
    • v.2 no.1
    • /
    • pp.61-80
    • /
    • 2013
  • Quantification of viable forms of microbial community (bacteria and fungi) using culture-dependent methods was done in order to characterize the indoor air quality (IAQ). Role of those factors, which may influence the concentration of viable counts of bacteria and fungi, like ventilation, occupancy, outdoor concentration and environmental parameters (temperature and relative humidity) were also determined. Volumetric-infiltration sampling technique was employed to collect air samples both inside and outside the schools. As regard of measurements of airborne viable culturable microflora of schools during one academic year, the level of TVMCs in school buildings was ranged between 803-5368 cfu/$m^3$. Viable counts of bacteria (VBCs) were constituted 63.7% of the mean total viable microbial counts where as viable counts of fungi (VFCs) formed 36.3% of the total. Mean a total viable microbial count (TVMCs) in three schools was 2491 cfu/$m^3$. Outdoor level of TVMCs was varied from 736-5855 cfu/$m^3$. Maximum and minimum VBCs were 3678-286 cfu/m3 respectively. Culturable fungal counts were ranged from 268-2089 cfu/$m^3$ in three schools. Significant positive correlation (p < 0.01) was indicated that indoor concentration of viable community reliant upon outdoor concentration. Temperature seemed to have a large effect (p < 0.05, p < 0.01) on the concentration of viable culturable microbial community rather than relative humidity. Consistent with the analysis and findings, the concentration of viable cultural counts of bacteria and fungi found indoors, were of several orders of magnitude, depending upon the potential of local, spatial and temporal factors, IO ratio appeared as a crucial indicator to identify the source of microbial contaminants.

Effect of Several Native Moss Plants on Particulate Matter, Volatile Organic Compounds and Air Composition

  • Gong, Gyeong Yeop;Kang, Ji Su;Jeong, Kyeong Jin;Jeong, Jun Ho;Yun, Jae Gill
    • Journal of People, Plants, and Environment
    • /
    • v.22 no.1
    • /
    • pp.31-38
    • /
    • 2019
  • Experiments were carried out to investigate the effects of mosses on the removal of particulate matter (PM 10) and volatile organic compounds (VOCs) in an indoor space and on the composition of air. For particulate matter removal experiments, 0.2 g mosquitto coil was burned in a glass chamber, where three kinds of mosses (Plagiomnium cuspidatum, Myuroclada maximowiczii, Etodon luridus) were placed. For VOCs removal experiments, 1 mL paint thinner was volatilized in a glass chamber, where Plagiomnium cuspidatum and Myuroclada maximowiczii were used. As a result, it was found that particulate matter was effectively removed by the three mosses, and the removal efficiency of particulate matter increased as the amount of mosses increased. The amount of VOCs was similar to the level in the control when a low amount of mosses (2 and 4 plates) was used. However, the removal efficiency of VOCs was significant when 6 plates of mosses were used. On the other hand, formaldehyde concentration was 40 times more than the control and carbon monoxide 30 times, when 0.2 g of mosquito repellent was completely burned in a glass chamber. Also formaldehyde removal effect was significant when 6 plates of mosses were placed. However, there was no change in the concentration of indoor oxygen, temperature and humidity by moss plants. In conclusion, the moss plants were effective in removing particulate matter and VOCs, and they are expected to be used for indoor decoration and landscape in order to improve indoor air quality in the future.

A Study on the Environmental Performance Level Measurement in the Lecture Room during Winter Time (동계 대학강의실 환경성능수준 측정에 관한 연구)

  • Ahn, Tae-Kyung
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.25 no.2
    • /
    • pp.3-9
    • /
    • 2018
  • This study is designed to measure the indoor environment and research on the environmental situation in the lecture room where the lecture is conducted during the winter time in order to understand the level of environment in the lecture room and then suggest the method of improving the environment in the lecture room in the future. The findings are as follows. First, the number of ventilation measured at Lecture Room 1 was 1.2 times/hour while that at Lecture Room 2 was 2.2 times/hour. Second, the lighting at Lecture Room 1 and 2 was 650~700 lux while the noise at Lecture Room 1 and 2 was not more than 60dB. Third, Group 1 and Group 2 felt in the same way that the air quality in the lecture room was not good when the air quality was measured in 30 minutes after the start of lecture. Fourth, both Group 1 and Group 2 showed the lowered concentration on the class in 30 minutes after the start of the class when the room was heated. But Group 1 got less drop in the concentration when they was put in the non-heated room. Fifth, As for the change in the carbon dioxide volume during lecture, the carbon dioxide volume in the room where the windows was closed rose 1,000~1,400ppm from that at the time of start, thus showing that the indoor air quality got worsened. In addition, it is hard to control the indoor temperature due to the heating and non-heating. Accordingly, it is necessary to get the heating system which can make the ventilation in order to keep the environmental level in the lecture room to a certain level and keep the proper indoor temperature.

Analyses of the current market trend and research status of indoor air quality control to develop an electrostatic force-based dust control technique (정전기적 힘을 이용한 실내공기 미세부유먼지 제거 요소기술의 개발을 위한 기술별 시장현황 및 연구 동향 분석)

  • Yoon, Young H.;Joo, Jin-Chul;Ahn, Ho-Sang;Nam, Sook-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6610-6617
    • /
    • 2013
  • This study examined the current and future Indoor Air Quality (IAQ) control device markets and analyzed the recent studies on indoor air pollutantr emoval to develop a new technology for fine dust control. Currently, the mechanical filter technique occupies the bulk of the IAQ control market but the electronic technique is emerging as an alternative to control fine dust efficiently. Among the gaseous VOCs and fine dust particles contaminating the indoor air quality, fine dust particles are more problematic because they threaten human health by penetrating deep into the body and producing secondary contaminants by chemical reaction with VOCs. The electronic IAQ control device using dielectrophoretic and electrostatic forces is a good option for public spaces where many people pass, and at the same time, it needs to consider temperature, humidity, and the particle properties of specific areas to highlight the control efficiency. Electronic-related technology is expected to be used widely in many public/private spaces wherever a dust-free environment is required.