• 제목/요약/키워드: Indoor Air quality

검색결과 1,015건 처리시간 0.033초

시스템에어컨과 환기시스템 설치 강의실에서 냉방시 열쾌적성 및 실내공기질 연구 (Study on Thermal Comfort and Indoor Air Quality in the Classroom with System Air-conditioner and Ventilation System for Cooling Loads)

  • 노광철;장재수;오명도
    • 대한기계학회논문집B
    • /
    • 제30권1호
    • /
    • pp.57-66
    • /
    • 2006
  • The experimental and the numerical study was performed on the comparison of thermal comfort(TC) and indoor air quality(IAQ) in the lecture room for cooling loads when the operating conditions are changed. PMV value and $CO_2$ concentration of the lecture room were measured and compared with the numerical results. The numerical results showed a good agreement with the experimental one and then the numerical tool was used to analyze thermal comfort and IAQ for a couple of operating conditions. As a result it was found that the increment of the discharge angle of system air-conditioner makes TC uniformity worse, but rarely affects IAQ. Also TC and IAQ were hardly affected by the variation of the discharge airflow. Finally it turned out that TC is merely affected by the increment of the ventilation airflow, but the average $CO_2$ concentration can be satisfied with Japanese IAQ standards of classrooms when the ventilation airflow is more than $800m^3/h$ in this study.

초등학교 실내외 미세먼지 농도 비교 연구 (A Comparative Study on Concentrations of Indoor and Outdoor Particulate Matters in Elementary Schools)

  • 김대현;손윤석;이태정;조영민
    • 대한원격탐사학회지
    • /
    • 제36권6_3호
    • /
    • pp.1721-1732
    • /
    • 2020
  • 초등학생들은 학교에서 많은 시간을 보내고 있으며 실내 공기오염에 더 많이 노출된다. 또한 초등학생들은 신체적으로 성장기에 있으며 어른에 비해 단위체중당 호흡량이 많으므로 실내 공기오염에 대한 민감도가 큰 것으로 알려져 있다. 따라서 학교 실내공기질은 초등학생들의 건강을 위한 중요한 요소이다. 본 연구에서는 서울지역 5개 초등학교에서 측정한 실내외 미세먼지 (Particulate matter: PM) 농도를 이용하여 상관분석을 실시하였다. 이를 통해 실외 PM이 실내 PM에 미치는 영향을 평가하였다. 또한 PM ratio, I/O ratio 등과 같은 통계분석을 진행하였다. 그 결과 초등학교의 실내외 PM의 상관성은 PM10보다 PM2.5와 PM1에서 더 유의미하게 나타났다. Indoor/outdoor (I/O) ratio의 경우 PM10에서 SD를 제외한 4개 초등학교에서 모두 1보다 높게 나타났다 (BB: 2.21, NS: 1.67, IS: 1.73, SI: 1.17). 이는 실내 학생의 활동도가 PM10의 농도에 큰 영향을 미친다는 것을 의미한다.

중앙공조 및 개별공조에서의 외조기 적용 (Application of Four-season Dedicated Outdoor Air Handling Unit in Central and Personal Air-conditioning)

  • 박승태;김영일;이태호;최세영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.591-596
    • /
    • 2008
  • The present study has been conducted to study the performance of dedicated outdoor air handling unit in central and personal air-conditioning. With conventional central and personal air-conditioning systems which are designed according to the maximum load, humidity increase above comfort level can not be avoided as the cooling load decreases. The adoption of dedicated outdoor air handling unit, however, can solve this problem. Moreover, the dedicated outdoor air handling unit has the characteristics of anti-bacteria due to dry coil, energy saving and good indoor air quality. During cooling seasons, dedicated outdoor air handling unit can save energy up to 30% than the conventional cooling+reheating system for controlling both temperature and humidity.

  • PDF

아파트의 실내외 공기질 향상을 위한 주동 배치 계획 연구 (A Study on the Site Planning of an Apartment Complex for Improving the Outdoor and Indoor Air Quality)

  • 신지웅;김태연;이경회
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.195-202
    • /
    • 2004
  • This study focuses on the impacts of apartment building arrangements on the outdoor and indoor air quality - the efficiency of natural ventilation in the outside/inside area of an apartment with consideration to the characteristics of an air flow in outside area depending on the types of the arrangements, the main direction of the wind, and the outside wind pressure on the building facade. As indices to evaluate the efficiency of natural ventilation, the concepts of "Age of Air" and "Purging Flow Rate(PFR)" were used in this study. As indices to classify the efficiency of indoor natural ventilation, the mean values of the wind pressure differences between the front and the back elevations of an apartment building were used. The research showed that the PFR of each apartment building arrangement ranges from 0.867 to 3.253. The "minus-shaped" arrangement showed the highest PFR, 2.306; the "zigzag-shaped" arrangement measured 1.889; the "angle-shaped" arrangement measured 1.465, and the "square-shaped" arrangement measured 1.241. Depending on the direction of the wind, the pressure differences range extremely, with variations from 170% to 2300%. Thus, the indoor natural ventilation efficiency can be changed by the pressure differences of the wind, which are sensitive to the main direction of the wind even though the structure and planning of the apartment complexes are the same. Despite the same direction of the wind, even the efficiency can be diverse. This study showed how to predict the most beneficial apartment building arrangement for the profitable natural ventilation efficiency in each direction of the wind.

바닥공조 시스템이 적용된 사무공간의 거주후 성능평가 (Post Occupancy Evaluation for Office Building with An Underfloor Air Distribution System)

  • 윤성훈;장향인;정해권;최선규;유기형
    • 한국태양에너지학회 논문집
    • /
    • 제31권6호
    • /
    • pp.78-85
    • /
    • 2011
  • In this study, an underfloor air distribution(UFAD) system installed on the S. office building was evaluated for its indoor environmental quality performance. Field measurement and survey were conducted for the overall POE(Post Occupied Evaluation). PMV(including temperature, humidity, air velocity and globe temperature) and several environmental components were measured while thermal comfort, thermal sensation, acoustical environment and others. were investigated through survey. Except for the direct upper part of the air supply diffuser on the floor, the indoor velocity was less than 0.25m/s, which has been suggested by ASHRAES tandard 55 as the limit for thermal comfort. MRT of the perimeter zone of the room showed a higher value than that in the interior because of the introduced solar radiation through the building envelope. PMV was generally maintained in the range of thermal comfort (from -0.5 to +0.5), though it weighted to the warm side. It was reported to have 61% positive response on thermal comfort and 55% on neutral thermal sensation. The results of each survey item showed some gender-based differences. Specifically, female respondents had higher degree of dissatisfaction with indoor air cleanness and acoustical privacy. The working surface showed more than 400 lux and the equivalent noise level showed less than 50 dB(A). In conclusion, the results of the measurement and survey showed good agreement. Indoor environmental quality of the subject office room where the UFAD system was installed showed an overall excellent performance.

다중이용시설별 실내공기 오염물질 농도분포 및 기준치 이상 값의 구성비 조사 (The Distribution of Indoor Air Pollutants by the Categories of Public-Use Facilities and Their Rate of Guideline Violation)

  • 전정인;이혜원;최현진;전형진;이철민
    • 한국환경보건학회지
    • /
    • 제47권5호
    • /
    • pp.398-409
    • /
    • 2021
  • Background: The types and effects of hazardous pollutants in indoor air may vary depending on the characteristics of the sources and pollutants caused by physical and chemical properties of buildings, the influence of outdoor air, and the exposure and use characteristics of residents. Objectives: This study was conducted to provide basic data on the establish of indoor air quality management for different classes of public-use facilities by presenting the characteristics of concentration distribution of hazardous pollutants by different public-use facilities and the status of the excess proportion of exceeding standards. Methods: This study analyzed self-measurement data from public-use facilities taken from 2017 to 2019 A total of 133,525 facilities were surveyed. A total of 10 types of pollutants that have maintenance and recommended standards stipulated in the Indoor Air Quality Control Act from the Ministry of Environment were investigated. The excess proportion and the substances exceeding the criteria for each type of public-use facilities for these pollutants were investigated. Results: As a result of the analysis of the proportion of exceeding the standard for each type of public-use facility, the facilities with the highest excess proportion of the standards for each hazardous pollutant were: PM10 in railway stations (8.93%), PM2.5 in daycare centers (7.36%), CO2 in bus terminals (2.37%), HCHO in postpartum care centers (4.11%), total airborne bacteria in daycare centers (0.69%), CO in museums (0.1%), NO2 in postpartum care centers (1.15%), Rn in museums (0.78%), total volatile organic compounds in postpartum care centers (7.20%) and mold in daycare centers (1.44%). Conclusions: Although uncertainty may arise because this study is a result of self-measurement, it is considered that this study has significance for providing basic data on the establishment in the future of indoor air quality management measures customized for each type of public-use facility.

광촉매 활용 광투과 노출콘크리트 블록 및 거푸집 개발 (Photocatalyst Applied Light Transparent Exposed Concrete Block and Mold Development)

  • 서승훈;강영언;전승헌;권시원;김병일
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.16-17
    • /
    • 2018
  • A few years ago, the rapid degradation of domestic air quality has led to the efforts of exhaust gas policy and fine dust mask, but it is not a fundamental measure. In Korea, photocatalyst will be applied to residential and multi-use facilites to purify indoor and outdoor air. Also, in this study, it is tried to produce exposed concrete that is aesthetically pleasing as well as air purification of indoor by combining with light transparent concrete according to the increasing interest in human indoor living environment. For this purpose, we have developed a block formwork for photocatalysis light transparent concrete and established a suitable manufacturing method for on-site construction.

  • PDF

都市 超高層 住居建築의 室內空氣環境의 評價에 관한 硏究 (A Study on the Evaluation of Indoor Air Environment in Super High-Rise Dwelling House)

  • 박미진
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.119-125
    • /
    • 2002
  • The concept of dwelling space is tend to be changed not only to have reasonable mobility but also to have high quality of indoor air with psychologicaa satisfaction and comfortable. Moreover, recent constructed buildings have a big problem because of exhausted pollution gas and particles from building materials. More serious problem occurs from its high air tightness reducing the ventilation for saving the energy and superior adiabatic insulators to have high heat efficiency. Indoor air quality in super high-rise dwelling house was investigated by measuring pollutants such as $CO_2,=;CO,\;MO_2,\;R_n,\;TSP,\;PM_{10}$, HCHO, Offensive ordor. Subjective evaluation of residential environment is processed for the inhabitants who live in research space by testing environmental load in accordance with environment morphology, exterior environmental factor and post occupancy correlation and influence of attention.

겨울철 연소오염원에 의한 도심 고층 아파트의 실내공기오염 (Indoor Air Pollution of a High-rise Apartment Caused by Combustion Sources in Winter)

  • 김종범;이광재;류성희;이재영;우성호;이승복;김경환;윤성택;배귀남
    • 한국입자에어로졸학회지
    • /
    • 제10권3호
    • /
    • pp.119-130
    • /
    • 2014
  • Home is a major living environment of children. In urban area, indoor air at home could be severely influenced by combustion sources such as vehicle exhaust and cooking. In this work, the air quality of a high-rise apartment was investigated by monitoring combustion-related air pollutants at both indoor and outdoor in winter of 2014. From 48-h continuous monitoring data, large amount of $NO_x$ was observed at the balcony of the high-rise apartment during the morning traffic hours. It deteriorated indoor air quality of the apartment. During the cooking activity, high peak episodes of ultrafine particles were seen. It was concluded that effects of vehicle exhaust and cooking activity on the indoor air of the high-rise apartment could be easily checked by $NO_x$ and ultrafine particle indicators, respectively.

초고층 공동주택의 이중외피 창호 유형별 실내기류 특성 비교 (Indoor Airflow of High-Rise Apartment with Different Types of Box-Windows)

  • 최태환;전미숙;이정현;김태연;이승복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.993-998
    • /
    • 2006
  • High-rise apartments have a problem using natural ventilation because of the strong outdoor wind velocity. Conventional high-rise apartments have adopted mechanical ventilation systems to maintain the indoor air quality. However, it leads to the overuse of electricity and the sick house syndrome. Double-skin facade is the alternative for the high-rise building to use natural ventilation and this study is focused on the performance of the box-window, which is a kind of double-skin facades. Indoor wind velocity and HCHO concentrations are analyzed with three types of box-windows: the diagonal type, parallel type and perpendicular type. The airflow is simulated by computational fluid dynamics program. Box-windows reduce the maximum value of indoor wind velocity about 50% compared with the single window and the HCHO concentrations do not have the big difference. Box-windows could be the alternative to enhance the use of the natural ventilation and indoor air quality of the high-rise apartment.

  • PDF