• 제목/요약/키워드: Indoor Air Pollution Particles Removal

검색결과 4건 처리시간 0.016초

초미세 크기의 마른 안개 생성과 이를 이용한 미세먼지 제거 연구 (Experimental study on the generation of ultrafine-sized dry fog and removal of particulate matter)

  • 김기웅
    • 한국가시화정보학회지
    • /
    • 제22권1호
    • /
    • pp.34-39
    • /
    • 2024
  • With the fine particulate matter (PM) poses a serious threat to public health and the environment. The ultrafine PM in particular can cause serious problems. This study investigates the effectiveness of a submicron dry fog system in removing fine PM. Two methods are used to create fine dust particles: burning incense and utilizing an aerosol generator. Results indicate that the dry fog system effectively removes fine dust particles, with a removal efficiency of up to 81.9% for PM10 and 61.9% for PM2.5 after 30 minutes of operation. The dry fog, characterized by a mean size of approximately 1.5 ㎛, exhibits superior performance in comparison to traditional water spraying methods, attributed to reduced water consumption and increased contact probability between water droplets and dust particles. Furthermore, experiments with uniform-sized particles which sizes are 1 ㎛ and 2 ㎛ demonstrate the system's capability in removing ultrafine PM. The proposed submicron dry fog system shows promise for mitigating fine dust pollution in various industrial settings, offering advantages such as energy consumption and enhanced safety for workers and equipment.

직화구이 음식점 방지시설의 오염물질 저감 효과 평가 - 전기집진방식을 중심으로 - (Evaluation of Removal Efficiency in Emission Pollutants by Air Pollution Prevention Facilities from Meat Grilled Restaurants - Focus on the Electrostatic Precipitator -)

  • 서장원;김영일;이희선;김지훈;김영두;신진호
    • 한국입자에어로졸학회지
    • /
    • 제17권4호
    • /
    • pp.115-123
    • /
    • 2021
  • The emission gas from meat grilled restaurants has unpleasant odor and sticky particulate matters (PM) in form of oil mist. This affects the residents living nearby. In oder to decrease the odor and PM, electrostatic precipitators (ESP) were installed at several restaurants by support of Seoul metropolitan government and emission characteristics of PM and odor were investigated. The removal efficiency of odor and PM at before- and after-ESP was that total hydrocarbon (THC), NH3, H2S, acetaldehyde, butyraldehyde were not much decreased. Total suspended particles (TSP) emitted from the vent was below the value of 7 mg/m3 regardless of the concentration of before-ESP and removal efficiency was in the range of 64 ~ 86%. The ratio of PM1.0 to PM10 of emission gas was over 0.9. So it was revealed that most PM of emission gas was PM1.0. The PM concentration in the air of the street near the vent was higher than another street due to the emission gas and the PM of indoor air of restaurant grilling meats was measured very high compared to outdoor air. So it needs more powerful ventilation of indoor air.

밀폐된 공간에서 환기에 의한 ETS 성분 제거

  • 황건중;이문수;나도영
    • 한국연초학회지
    • /
    • 제21권1호
    • /
    • pp.102-108
    • /
    • 1999
  • This study was conducted to evaluate the ventilation to remove gases, vapor and particles of environmental tobacco smoke(ETS) in a closed room. The ventilation rate choosed were 0.445 ㎥/min, 0.528 ㎥/min, and 0.625 ㎥/min. ETS components measured were total suspended particle(TSP), ultraviolet particulate matter(UVPM), fluorescent particulate matter(FPM), solanesol, carbon dioxide($CO_2$), carbon monoxide(CO), nicotine, and 3-ethenylpyri-dine(3-EP). The concentration of ETS components measured rapidly decreased as increasing ventilation rate, but the removal efficiency by ventilation was different from each ETS compounds. The $CO_2$, and CO, gaseous components of ETS, were dominant components to be removed from the room by ventilation. The ventilation with 0.528 ㎥/min for 1 hr was enough to remove over 99% of those gaseous components. Nicotine and 3-EP needed the ventilation for 2 hrs to reduce over 95 % of those components. As the same ventilation rate, 99 % of TSP and solanesol concentration were removed from the room within 2 hrs, UVPM and FPM concentration decreased 90 %.

  • PDF

도시철도 차량 하부의 풍속 및 미세먼지 농도 특징 (Characteristics of Wind Speed and PM10 Concentration underneath Railway Trains)

  • 김종범;우상희;장홍량;최진원;황문세;박형구;윤화현;정준식;배귀남
    • 한국철도학회논문집
    • /
    • 제20권1호
    • /
    • pp.11-19
    • /
    • 2017
  • 도시철도 차량의 운행은 터널 공기를 오염시키는 주된 원인이므로, 마모입자를 제거하는데 집진장치가 유용한 수단이 될 수 있다. 차량의 하부에 장착될 수 있는 집진장치의 설계조건을 파악하기 위하여 3차원 초음파 풍속계와 입자측정기를 사용하여 차량 하부의 풍속과 입자농도를 조사하였다. 2015년 2월 10일 수도권 지하철 5호선에서 운행되는 차량을 대상으로 측정하였다. 측정자료는 역 사이 노선의 형상(직선, 곡선)과 차량 속도패턴(가속, 정속 및 감속)을 구분하여 분석하였다. 차량속도도 함께 분석하였다. 직선 및 곡선 구간 모두 차량 하부의 평균 풍속은 차량속도의 약 30%이었고, 미세먼지($PM_{10}$) 농도는 약 $200{\mu}g/m^3$이었다. 감속구간에서 평균 $PM_{10}$ 농도는 가속구간에 비해 더 높았다.