• 제목/요약/키워드: Indoor Air

검색결과 2,357건 처리시간 0.025초

확률론적 모의실험을 이용한 공기청정기의 실내공기중 PM10과 $NO_2$ 제거효율에 관한 연구 (Efficiency of Removal for PM10 and $NO_2$ by Air Cleaner in Residential Indoor Environment with Monte-Carlo Simulation)

  • 이철민;김윤신;이태형;김종철;김중호
    • 한국환경보건학회지
    • /
    • 제30권3호
    • /
    • pp.221-229
    • /
    • 2004
  • We estimated decreasing rate of indoor air pollutants which are PM10 and $NO_2$ by the air cleaner in indoor environment. This study respectively examined concentration of PM10 and $NO_2$ two times in 34 sites located in Seoul and Kyung-gi Do from April to September in 2003. Sectional period was respectively divided for operating the air cleaner and non-operating the air cleaner. Moreover, questionnaire was executed to grasp physical characteristic of objective building and residential characteristic of residents by using method of self-entry. There was a trend that concentration of PM10 and $NO_2$ separated number of residents during operating period respectively decreased among indoor air. According to the existence of smoker in indoor, both concentration of PM10 and $NO_2$ during operating period decreased in each case, and according to existence of pets, both cases decreased concentration of pollutants by operating the air cleaner. We used Monte-Calro simulation to remove uncertainty and identify efficiency of eliminated pollutants such as PM10 and $NO_2$ by the air cleaner. Average efficiency of removal for PM10 and $NO_2$ were 61.84${\pm}$23.04% and 48.67${\pm}$18.03% respectively.

스킨답서스에 LED와 Fan을 이용한 실내공기정화 시스템 (The Indoor Air Purification System Using LED and Fan for Epipremnum aureum)

  • 김태현;박준모;김수찬
    • 융합신호처리학회논문지
    • /
    • 제19권4호
    • /
    • pp.167-173
    • /
    • 2018
  • 빛이 부족하고 공기 순환이 원활하지 않은 실내에서 식물의 지상부와 지하부를 활용한 공기 정화 시스템을 제안한다. 제안된 시스템은 식물의 공기정화 효과를 극대화하고자 지상부는 청색과 녹색의 LED를 조합한 혼합광과 자연광에 가까운 고연색 LED를 각각 조사하고 지하부의 토양을 필터로 활용하고자 팬을 이용하여 강제 순환하였다. 광원과 팬이 결합된 실내공기정화 시스템이 식물만 배치된 경우보다 오염된 공기를 단시간에 가장 많이 제거하였다. 실내 공기정화 시스템의 혼합광과 고연색광 두 가지의 경우에서 식물만 배치된 경우보다 미세먼지는 각각 14%, 14.2%, TVOC는 7.5%, 9.4% 로 더 크게 감소하였다. 팬을 15분 동안만 가동한 실험에서도 TVOC가 97.8%로 크게 감소하였다. 식물의 광합성과 토양을 필터로 활용하는 것이 오염된 공기를 짧은 시간에 정화시킬 수 있었고 팬의 일시적인 가동으로도 지속적인 가동의 효과를 얻었다.

페리미터존의 에어배리어 공조방식에 따른 실내 열환경 평가 (Evaluation of Indoor Thermal Environment According to Air-Barrier Air Conditioning System in Perimeter Zone)

  • 박병윤;함흥돈;손장열
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.370-376
    • /
    • 2005
  • For the purpose of investigating the effective removal of heating/cooling load from light-weighted building envelope, two air-conditioning systems, conventional parameter air-conditioning system and air-barrier system, are evaluated and compared by both experiment and simulation with six different cases during heating and cooling season. In addition, the characteristics of window-side building thermal load are assessed by varying supply air velocity in order to seek the optimal system operation condition. The results are as follows. 1) Air-barrier system is more effective to remove heating/cooling load at perimeter zone than conventional parameter air-conditioning system. Moreover, the better effectiveness appears during cooling season than during heating season. 2) The experiment during cooling season provides that indoor temperature of air-barrier system shows $1^{\circ}C$ less than that of the conventional system with similar outdoor air temperature profile, and indoor temperature distribution is more uniform throughout the experimented model space. It concludes that air-barrier system can achieve energy saving comparing to the conventional system. 3) The capturing efficiency of air-barrier system is 0.47 on heating season and 0.2 on cooling season with the same supply air volume. It results that the system performs effectively to remove building thermal load, moreover demonstrates high efficiency during cooling season. 4) The simulation results provide that capturing efficiency to evaluate the effective removal of building load from perimeter zone shows high value when supply air velocity is 1 m/s.

주거용 건축물의 실내 라돈농도 경감방안에 관한 연구(I) -Test Cell Study (A Study on Mitigation Methods of Indoor Radon Concentration in Residential Buildings(I) - Test Cell Study)

  • 차동원
    • KIEAE Journal
    • /
    • 제1권2호
    • /
    • pp.21-28
    • /
    • 2001
  • Naturally-ocurring short-lived decay products of radon gas in indoor air are the dominant source of ionizing radiation exposure to the general public. It is written in BEIR VI Report(l999l the radon progeny were identified as the second cause of lung cancer next to cigarette or 10 % to 14 %(15,400 to 21,800 persons p.a.) of all lung cancer deaths in USA. Indoor radon concentrations in houses typically result from radon gaining access to houses mainly from the underlying soil. In the States, they have "Indoor Radon Abatement Act" which was converted from "Toxic Substance Control Act" in 1988 to establish the national long-term goal that indoor air should be as free of radon as the ambient air outside of buildings. To review and study techniques for controlling radon, two test cells were constructed for a series of tests and are under measuring indoor and soil gas (underneath of floor slab)radon concentrations according to EPA's measurement protocol. In this paper, important theoretical studies are previewed and the following paper will explain the test results and confirm the theories reviewed to find out suitable coefficients. On the basis of test analysis, it will be described and evaluated various techniques that can be used to mitigate elevated indoor concentration of radon including the control of radon and its decay products.

  • PDF

건물의 유효누출면적 및 박스모델을 이용한 염소 실내 누출의 위험지역 완화에 관한 연구 (A Study on the Mitigation of Threat Zones for Indoor Chlorine Release using Effective Leakage Areas of Building and Box Model)

  • 곽솔림;이은별;최영보
    • 한국안전학회지
    • /
    • 제33권5호
    • /
    • pp.51-59
    • /
    • 2018
  • It is difficult to determine the outdoor toxic level of hazardous chemicals that are leaked in the building, since there are no efficient ways to calculate how much percentage of the leaked chemicals is released into the outdoor atmosphere. In address to these problems, we propose a reasonable box model that can quantitatively evaluate the mass rate of the indoor chlorine leakage into the outside of the building. The proposed method assumes that the indoor chlorine leakage is fully mixed with the indoor air, and then the mixture of the chlorine and indoor air is exfiltrated into the outside of the building through effective leakage areas of the building. It is found that the exfiltration rate of the mixture of the chlorine and indoor air is strongly dependent on the temperature difference between inside and outside the building than the atmospheric wind speed. As compared with a conventional method that uses a vague mitigation factor, our method is more effective to evaluate the outdoor toxic threat zone of the chlorine that are leaked in the building, because it can consider the degree of airtight of the building in the evaluation of the threat zone.

초등학교 교실공기질의 특징과 제어방안에 관한 연구 (Study on the Characteristics of Air quality in the Classroom of Elementary School and Its Control Methods)

  • 정지원;이희관
    • 대한환경공학회지
    • /
    • 제32권4호
    • /
    • pp.311-322
    • /
    • 2010
  • The common life with modern urban residence, spending more than 80~90% of daily life in indoor environment, makes the importance of indoor air quality (IAQ) even higher. Many efforts have made to improve indoor air quality (IAQ), which requires those systematic approaches for field practice. A recent study reported that no general approach cannot be made for IAQ improvement due to the great deal of variety in different indoor environments. Those indoor spaces included in Korean IAQ regulation were classified based on their characteristics and the IAQ guideline was suggested for each group of indoor spaces. Apart from those indoor spaces, the classroom in elementary school has different characteristics. By introducing the systematic approaches, the elementary classroom was surveyed and analyzed to understand its characteristics in due IAQ consideration. Based on the characteristics, there are several IAQ control measures suggested, including ventilation operation, dust mat installation, and white board. $CO_2$ and airborne dust were monitored and analyzed in order to evaluate the effectiveness of each control measure to IAQ. It was found that the general level of $CO_2$ concentration was managed under the IAQ guideline by applying the ventilator operation. The ventilation was also effective to the fugitive airborne particulate in elementary classroom environment.

공동주택의 하절기 자연환기 시 지붕면 일사수열이 최상층 실내온열환경에 미치는 영향 분석 (Analysis of the Irradiated Solar Heat Effect on Indoor Thermal Environment of the Top Floor Units of Apartment Houses in the Summer - On Condition that All Openings of the Units are Opened -)

  • 최동호
    • 한국태양에너지학회 논문집
    • /
    • 제25권1호
    • /
    • pp.45-55
    • /
    • 2005
  • In the summer, the irradiated solar heat gain through the roof has an effect on the thermal environment of the top floor units of apartment houses. This paper investigated the differences of the indoor air temperature, globe temperature and thermal comfort index between the top floor unit and the middle floor unit by measuring them at the sample units on the condition that all the openings of the units are opened. The purpose of this paper is to provide quantitative data about the irradiated solar heat gain during the summertime through the roof of an apartment house and these data to be the source to reevaluate the appropriate roof insulation efficiency. From this study, we obtained three brief results as follows. Indoor air temperature difference between the two sample units shifts a day. Indoor air temperature at the top floor unit is $0{\sim}1.8^{\circ}C$ higher than that of the middle floor unit from 12:00 p.m. to 12:00 a.m. and $0{\sim}2.8^{\circ}C$ lower from 12:00 a.m. to 12:00 p.m. The evaluation of the indoor thermal comfort index and the globe temperature shows similar results as the indoor air temperature measuring. Results of this experiment verified the actual existence of indoor air temperature difference between the top floor unit and the middle one and this difference comes from the heat storage of the roof.

복합적 기능의 식물 애플리케이션 디자인을 위한 사용자 조사 (A Study on User's Opinion for Designing of Multi-Functional Plant Applications)

  • 이하나;박한나;백진경
    • 한국과학예술포럼
    • /
    • 제37권4호
    • /
    • pp.297-308
    • /
    • 2019
  • 연일 최대치를 갱신하고 있는 미세먼지 수치로 인해 대한민국 정부는 공기 오염과 씨름하고 있으며, 환기의 어려움과 실내 방출 오염물질로 인한 실내공기 오염 문제 역시 심각하다. 이러한 실내의 공기 질 개선에 식물의 공기 정화 효과가 돋보이고 있다. 본 연구는 현대인의 생활 환경과 실내공기 오염의 위해성 및 식물의 개선 기능을 조사하고, 식물 애플리케이션 사용을 활성화하기 위하여 시작되었다. 본 연구의 목적은 국내외 식물 관련 애플리케이션의 주요기능과 디자인 현황을 파악하고, 현대인의 식물 애플리케이션 사용 실태를 분석하여 더욱 편리한 식물 관련 지식 습득을 돕는 것이다. 따라서 본 논문은 실내공기 오염이 건강에 미치는 영향과 식물 관련 애플리케이션에 대한 사용자 의식조사를 이행하였다. 이를 통해 새로운 복합적 기능의 식물 애플리케이션 디자인을 제안하는 데 근거를 마련하고자 시도하였다. 연구 결과 및 내용은 다음과 같다. 첫째, 이론적 고찰 결과 실내공기 오염은 실내 생활의 비중이 높은 현대인에게 더욱 위험하며 건강에 악영향을 끼친다. 이와 같은 문제 해결을 위하여 실내공간에 식물을 두는 것만으로도 공기 정화 및 스트레스 감소에 크게 효과를 볼 수 있었다. 둘째, 선행 연구 분석 결과 실내공기 오염의 위해성과 건강에 미치는 영향, 공기정화 식물의 실내 공기개선 사례와 관련된 연구 사례를 찾아볼 수 있었으며, 애플리케이션 개발 및 개선을 통한 사용자의 행동 개선 사례를 파악할 수 있었다. 셋째, 국내외 식물 애플리케이션 현황 조사 결과 현재 설치 수가 높은 애플리케이션의 주요 기능은 식물식별, 물 주기 알림, 식물 기초 정보 제공 등이 있었으며, 카메라를 통한 식물 식별 애플리케이션이 다수였다. 넷째, 설문조사 결과 대부분의 응답자가 식물을 키우고 있거나, 키운 경험이 있었다. 식물 애플리케이션을 사용한 경험이 거의 없는 사람 역시 향후 식물 관련 애플리케이션 사용에 긍정적인 의견을 밝혔다. 또한, 공기 오염 등의 사회 문제로 인하여 식물을 활용한 공기 정화, 기능성 식물 등에 높은 관심을 보이었다. 이러한 연구 결과를 바탕으로 실내공기 오염을 개선할 수 있는 식물과 이와 관련된 정보 제공을 용이하게 도울 수 있는 복합적 기능의 식물 애플리케이션의 필요성을 제안하고자 한다.

실내 환경조절 기기에 대한 거주자 의식 실태조사 연구 -광주광역시를 중심으로- (A Study on the Actual Conditions and Responses of Indoor Climate Control Elements chosen by Inhabitants through Questionnaire - Focused in Gwangju City-)

  • 송민정;장길수
    • KIEAE Journal
    • /
    • 제7권5호
    • /
    • pp.73-80
    • /
    • 2007
  • Indoor climate control equipments is used to make the indoor environment more comfortable when indoor condition is not satisfactory to inhabitants. In this study, which instrument is preferred to control indoor climate and which is not preferred were surveyed with questionnaire. With this result, the needs of dwellers and wanting performance of housing could be revealed. Results are followings 1) The satisfaction ratio and equipment possession ratio of apartment houses' is higher than that of detached dwelling's 2) It is recognized for inhabitants that air cleaner is the mostly used equipment and best equipment for indoor comfort. 3) Electronic fomentation mat is recognized as the most problematic equipment for securing inhabitant's comfort. And air conditioner is considered negative for 60% of responser's. As grow older, this trend is increasing.