• 제목/요약/키워드: Indoor Air

검색결과 2,362건 처리시간 0.03초

신축 주택의 톨루엔 발생량 모델을 이용한 건강위해성 평가 (Risk Assessment by Toluene Source Emission Model in Indoor Environments of New Houses)

  • 김영희;양원호;손부순
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.398-403
    • /
    • 2006
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Understanding the effectiveness of indoor air quality control depends on knowledge of the characteristics of air pollutants in indoor air, especially their quantities and persistence, and the relevance of indoor sources to these factors. Toluene within new and established houses has been determined and factors significant to its presence have been identified. A total of 30 selected houses in Seoul, Asan and Daegu areas that were constructed within 4 years and over 4 years of construction were measured the concentration of toluene from July to September in 2004. Toluene emission decay of double-exponential model exhibited good fit of $Y=276.37e^{-1.21x}(R^{2}=0.34,\;P=0.06)$ for 2 years and then $Y=51.54e^{-0.11x}(R^{2}=0.40,\;P=0.0)$ from 23 years in new houses. In case of living in new houses, noncarcinogenic health effects of exposure to toluene was 1.38 of hazard quotient (HQ) comparing to toluene reference dose of 0.13 mg/kg-day.

겨울철 학교교실의 실내열.공기환경 실태와 학생들의 주관적 반응 (A Study of Indoor Thermal and Air Quality in Middle and High School Classrooms during Winter)

  • 최윤정;나선희;조수연
    • 한국생활과학회지
    • /
    • 제18권2호
    • /
    • pp.509-522
    • /
    • 2009
  • This is a basic study to improve air quality of school classrooms in winter time. The purposes are to check indoor thermal and air environment in school classrooms during winter and to analyze influencing factors on indoor environment. The measurements of students' physical elements with questionnaire surveys were carried out in a total of 6 classrooms. As a result, this research shows that the temperature of one classroom was below indoor thermal standard level, three classrooms had lack of heat, and two classrooms are heated much, which induce relatively low humidity. All of 6 classrooms had lack of ventilation, being high level of $CO_2$ concentration and 2 classrooms are in condition of high PM10 concentration. The majority of students(76%) answered that the cause of their 'heated space syndrome' is because of the lack of ventilation. Students' opening windows for ventilations is hardly carried out at normal times, except that indoor temperature is over standard. That is, we can suggest one of solutions, which is to enable students to operate heating and ventilating system by themselves according to students' physical condition.

민감시설의 건물 특성에 따른 실내공기질 분석 (Analysis of Indoor Air Quality in vulnerable facilities according to building characteristics)

  • 조경화;권순정;성민기;김선숙
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제23권2호
    • /
    • pp.19-26
    • /
    • 2017
  • Purpose: With the increasing of public-use facilities, there has been a growing concern over Indoor Air Quality(IAQ) of public-use facilities. Because the facilities are easy to be exposed to indoor air pollutants, they needs to be periodically managed the IAQ. Methods: In this study, indoor air pollutant concentrations of 24 vulnerable facilities were measured and compared. The measurements were conducted for pollutants which are defined in 'IAQ Control In Public-Use Facilities, etc. Act'. We took two measurements, the first was carried out in summer and the second was proceeded in winter. We analyzed the values according to the type of facilities and pollutants. Results: There was a difference in pollutant concentrations by the season and in occurrence characteristics by the measurement spot. Therefore, we need to manage pollutant concentrations by characteristics of occurrence. Implications: Based on the comparative analysis of pollutant concentrations, we suggested cause and improvement strategies for IAQ management of Vulnerable facilities.

안트라사이트를 혼입한 시멘트 보드의 라돈흡착 특성 (Radon adsorption properties of cement board using anthracite)

  • 경인수;편수정;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.232-233
    • /
    • 2018
  • Among the recent environmental pollution, indoor air pollution has an adverse effect on the health of indoor residents. Radon, one of the causes of indoor air pollution, is released from concrete, gypsum board and asbestos slate among building materials. Radon is a primary carcinogen and is a colorless, tasteless, odorless inert gas that adheres to airborne dust and enters the body through breathing. At this time, there is a risk of developing cancer if the alpha rays from the lononggas entering the human body destroys the lung tissue and is continuously exposed to a high concentration of lonon gas. The World Health Organization (WHO) has emphasized the reduction of radon and its exposure to radon by classifying it as a first-level carcinogen, but many people have not recognized it yet, and the research is underdeveloped. Therefore, this study was carried out to investigate the properties of adsorbed coconut radon to prevent the inflow of radon gas, which is an air pollution source of indoor air, and to prevent inflow into the human body.

  • PDF

산업체 작업환경의 실내 공기에서 미생물 오염도 (Microbiologic Pollution of Indoor Air in Industrial Work-Places)

  • 강경희;장명웅
    • 생명과학회지
    • /
    • 제9권3호
    • /
    • pp.314-327
    • /
    • 1999
  • This study was investigated to isolate identify the total bacteria and fungi from the indoor air of work-place of the shoes, paint, stainless steel, and plastic industries. The number of bacterial colonies on the nutrient agar plates were calculated by the open petridish method for 30 minutes in indoor air of work-places at the autumn and winter. The isolated bacteria were identified by Gram stain and biochemical test using API Staph and API 20E kits. The isolated fungal colonies were identified by gross appearance of the giant colonies and microscopic examination of their spore and hyphal characteristics on the slide culture method. The minimum inhibitory concentration (MIC) of several antibiotics against isolated bacteria was determined by the microdilution method with Mueller-Hinton broth. The 70-400 colonies in autumn and 54-236 colonies in winter were isolated from the indoor air of work-places of several industry. The isolation rates of Gram positive cocci, Gram positive bacilli, Gram negative bacilli, and Gram negative cocci were 46.3%, 19.8%, 17.3%, and 16.1%, respectively. In Gram positive cocci, the most strains were identified as Aerococcus spp, Micrococcus spp, and Staphylococcus spp. In Gram positive and negative bacilli, and Gram negative cocci were identified as Bacillus spp, Pseudomonas spp, and Neisseria spp, respectively. The frequently isolated fungi were Aspergillus spp, Penicillium spp and Rhizopus spp, respectively. The frequently isolated Aerococcus spp, Micrococcus spp, and Staphylococus spp were highly resistance against ampicillin, erythromycin, methicillin, and tetracycline. These results arouse our attention to microbiologic pollution in the indoor air of work-places of industries.

  • PDF

1980년대 초 서울의 실내외 대기질 수준 - Sherwood 교수의 측정 자료 활용 (Historical Data on Indoor and Outdoor Air Quality in Seoul, Korea)

  • 이기영
    • 한국환경보건학회지
    • /
    • 제39권1호
    • /
    • pp.99-103
    • /
    • 2013
  • Objectives: This paper was prepared in memory of Jerry Sherwood, who provided a significant contribution to the Korean environmental and occupational health fields. Methods: Rare air quality data in Seoul were gathered by Jerry Sherwood when he visited Korea in the early 1980s. $SO_2$ and TPM concentrations were measured. These air quality measurements were based on ambient stationary monitoring and indoor air quality monitoring in various locations. Measurement during transportation was also applied. Results: Ambient $SO_2$ and TPM concentrations in Seoul were very high in the early 1980s. Ambient $SO_2$ concentrations were higher at nighttime. While ambient $SO_2$ concentrations varied by location, the Guro industrial area showed high levels. When indoor sources were presented, indoor $SO_2$ concentration was higher than outdoor level. Coal briquettes were closely associated with high indoor $SO_2$ concentration. Conclusion: This paper provided valuable historical information of air quality in Seoul.

황토와 다공성 규조토 필터에 의한 실내 오염 물질의 흡착 연구 (The Study for Adsorption of Indoor Pollutants by Ocher and Diatomite Filter)

  • 김호건;;남기우
    • 한국산업융합학회 논문집
    • /
    • 제23권4_2호
    • /
    • pp.583-591
    • /
    • 2020
  • Environmental problems have showen over the past decades due to the rapid development of the world economy and the continued growth of the population. Ocher has been widely used for water treatment research, but few studies have been conducted on adsorption of air pollutants using ocher and porous diatomite earth for indoor air purification. In this study, ocher and diatomite earth were sintered with filters to remove indoor air pollutants. The four types of TMA, H2S, NH3 and CH3COOH were used to study the adsorption efficiency of ocher and porous diatomite filters. With the proper use of ocher, diatomite and copper catalysts, indoor air pollutants could be adsorbed. Alkaline substances (TMA and NH3) and acidic substances (H2S and CH3COOH) were able to adsorb at 120 and 90 minutes, respectively.

실내 공기질 개선을 위한 광촉매를 혼입한 수성도료의 특성 (Properties of Water-based Paint mixed with Photocatalyst for Indoor Air Quality Improvement)

  • 최병철;박채울;경인수;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.29-30
    • /
    • 2020
  • As the modern society enters, the building becomes sealed and the public's interest in the environment increases, so the interest in indoor air pollution increases and the environmental pollution is raised as an important issue not only outdoors but also indoors. In addition, the emergence of sick house syndrome (SHS) has increased the interest in formaldehyde and is a cause of deteriorating indoor air quality. Accordingly, this study prepared a functional paint by incorporating a photocatalyst in an aqueous paint, and conducted formaldehyde adsorption experiments and functional evaluation. As a result of the experiment, as the photocatalyst was added, the formaldehyde adsorption performance tended to increase. In addition, as a result of measuring the impact resistance and alkali resistance according to the KS standard, there is no difference in residual cracks and cracks between the water-based paint without the photocatalyst and the water-based paint with the photocatalyst added. Therefore, it is considered that the water-based paint added with a photocatalyst can improve the indoor air quality by adsorbing formaldehyde and can be used as a functional paint because the functionality is not different from that of a general water-based paint.

  • PDF

소규모 다중이용시설의 실내공기질 실태조사 및 건강위해성평가: 민감군 이용시설을 중심으로 (Indoor Air Quality and Human Health Risk Assessment for Un-regulated Small-sized Sensitive Population Facilities)

  • 신혜진;박우상;김보경;지경희;김기태
    • 한국환경보건학회지
    • /
    • 제44권4호
    • /
    • pp.397-407
    • /
    • 2018
  • Objectives: The purpose of this study is to investigate human health risk assessment of indoor air pollutants at small-sized public-use facilities (e.g., daycare centers, hospital and elderly care facilities) that the susceptible population is mainly used. Methods: To assess indoor air quality (IAQ), the concentrations of indoor air contaminants such as HCHO, benzene, toluene, ethylbenzene, xylene, styrene, PM-10, CO, $NO_2$ and $O_3$ in air samples were measured according to the Indoor Air Quality Standard Method. By conducting the questionnaire survey, the major factors influencing IAQ were identified. Human health risk assessment was carried out in the consideration of type of use (user and worker) at 75 daycare centers, 34 hospitals and 40 elderly care facilities. Results: As a result of measurement of indoor air contaminants, the average concentration of HCHO and TVOCs in hospitals was higher than daycare centers and elderly care facilities, about 8.8 and 23.5% of hospitals were exceeded by IAQ standard. In human health risk assessment, for the user of daycare centers and elderly care facilities, the mean carcinogenic risk of HCHO inhalation was higher than acceptable value. Except for HCHO, other values were determined under acceptable risk. Similarly, for the worker of hospitals, the mean carcinogenic risk of HCHO inhalation was higher than acceptable value and other values were evaluated under acceptable risk. In contrast, the risk levels of other contaminants measured in elderly care facilities were acceptable. In the determination of factors influencing IAQ, the construction year, building type, ventilation time, and the use of air cleaner were identified. Conclusions: This study provides the information for establishing the plans of public health management of IAQ at small-sized public-use facilities that have not yet been placed under the regulation. The findings suggest the consideration of human health risk assessment results for the IAQ standards.

신축사무실 내 식물 적용 후 재실자 안구 증상 및 실내공기질 평가 (Assessment of Indoor Air Quality and the Eye Symptom of Occupants in Newly-built Office Building after Planting Indoor Plants)

  • 김효진;김호현
    • 한국안광학회지
    • /
    • 제21권3호
    • /
    • pp.265-274
    • /
    • 2016
  • 목적: 본 연구에서는 신축사무실 건물 및 재실자를 대상으로 식물적용에 따른 안구건조 증상 및 실내공기질 등에 대한 변화를 평가하고자 하였다. 방법: 세종시 정부청사 신축건물 및 사무실 재실자를 대상으로 하였다. 식물적용에 따라 실내공기질을 측정하였으며, 휘발성유기화합물류와 알데하이드류 및 온 습도를 측정하여 평가하였다. 안구건조 증상은 Ocular surface disease index(OSDI)를 이용하여 정상, 경도, 중등도, 및 중증으로 분류하여 측정하였다. 결과: 식물적용사무실에서 휘발성유기화합물류의 감소율이 다소 높게 나타나 식물적용으로 인한 저감효과가 있는 것으로 조사되었다. 식물적용 재실자에서 새건물증후군 증상 점수가 점차적으로 감소하였고, 식물미적용사무실 재실자에서는 새건물증후군 증상 점수가 상승하였다. 재실자의 안구건조설문결과에서 통계적으로 유의한 차이는 관찰되지 않았다. 결론: 식물적용 사무실 내 유해물질의 감소효과가 있었고, 재실자를 통한 설문조사결과 안구건조 및 새건물증후군 증상에 긍정적인 효과는 있었다. 개인의 민감도 등에 의한 차이 및 현장조사로 인한 연구의 제한점 등을 보완한 장기 연구가 필요하다.