• Title/Summary/Keyword: Indoor

Search Result 6,759, Processing Time 0.025 seconds

A Study of IndoorGML Automatic Generation using IFC - Focus on Primal Space - (IFC를 이용한 IndoorGML 데이터 자동 생성에 관한 연구 - Primal Space를 중심으로 -)

  • Nam, Sang Kwan;Jang, Hanme;Kang, Hye Young;Choi, Hyun Sang;Lee, Ji Yeong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.623-633
    • /
    • 2020
  • As the time spent in indoor space has increased, the demand for services targeting indoor spaces also continues to increase. To provide indoor spatial information services, the construction of indoor spatial information should be done first. In the study, a method of generation IndoorGML, which is the international standard data format for Indoor space, from existing BIM data. The characteristics of IFC objects were investigated, and objects that need to be converted to IndoorGML were selected and classified into objects that restrict the expression of Indoor space and internal passages. Using the proposed method, a part of data set provided by the BIMserver github and the IFC model of the 21st Century Building in University of Seoul were used to perform experiments to generate PrimalSpaceFeatures of IndoorGML. As a result of the experiments, the geometric information of IFC objects was represented completely as IndoorGML, and it was shown that NavigableBoundary, one of major features of PrimalSpaceFeatures in IndoorGML, was accurately generated. In the future, the proposed method will improve to generate various types of objects such as IfcStair, and additional method for automatically generating MultiLayeredGraph of IndoorGML using PrimalSpaceFeatures should be developed to be sure of completeness of IndoorGML.

A Study of Subspacing Strategy for Service Applications in Indoor Space (실내공간 응용 서비스를 위한 공간분할 방법에 관한 연구)

  • Kang, Hye Young;Jung, Hyo-jin;Lee, Jiyeong
    • Spatial Information Research
    • /
    • v.23 no.3
    • /
    • pp.113-122
    • /
    • 2015
  • Recently, according to developing advanced construction technologies, buildings has been enlarged such as high-rise buildings or complex buildings associated with underground facilities. The number of indoor activity population has increased very quickly. Because of that, technical requirements for Indoor location based service (Indoor LBS) also have been increased. Although indoor networks have to be constructed for efficient LBSs in indoor space based on OGC IndoorGML, it is not suitable for large and complex space to apply the simple network structure to constructing indoor navigation networks. The indoor navigation network has to be constructed according to logical, physical, and functional constraints for indoor space. In order to do that, subspacing methods are required to partition large and complex indoor space into proper size of subspace. In this paper, we proposed the basic requirements of subspacing in indoor space for creating efficient indoor network, as well the work process of subspacing in indoor space.

Converting Triangulated 3D Indoor Mesh Data to OGC IndooGML (삼각분할된 3차원 실내공간데이터를 OGC IndoorGML로 변환하는 방법)

  • Li, Ki-Joune;Kim, Dong Min
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.6
    • /
    • pp.499-505
    • /
    • 2018
  • Most of 3D indoor spatial data recently constructed by many projects merely focus on the visualization rather than geospatial information applications. The 3D indoor data for visualization in 3DS or COLLADA format are based on triangular mesh representation. In order to implement meaningful applications, we need however more meaningful information in 3D indoor spatial data than visualization data in triangular meshes. For this reason, an OGC (Open Geospatial Consortium) standard, called IndoorGML(Indoor Geographic Markup Language) was published to meet the requirements on 3D indoor spatial data for several geospatial applications for indoor space more than simple visualization. It means that it becomes a critical functional requirement to convert triangular mesh representation in 3DS or COLLADA to IndoorGML. In this paper we propose a framework of the conversion, which consists of geometric, topological, and semantic construction of data from triangular meshes. An experiment carried out to validate the proposed framework is also presented in the paper.

A Study on Air Pollution in Indoor Gymnasiums (실내체육관에서의 공기오염에 관한 연구)

  • 윤승욱;김윤신;이종대;이철민;조용성
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.32-37
    • /
    • 2000
  • Nowadays, a new word called SBS(sick building syndrome) has been come into existence. At the point of time when an interest about indoor air pollution and, according to this, countermeasure plan are internationally. Moreover institutional countermeasure should be attended at national level since indoor air quality in public places where many people gather is directly connected with national health. Especially indoor pollution of indoor stadia where all sorts of sports are held can give rise to every kinds of respiratory ailments to players as well as audiences. So it is presented as a main factor that indoor space of stadia is crowded with players and audiences compared with other kinds of indoor space. Therefore, in this research to analyze pollution degree of indoor circumstance for gymnasium and exercising room of folk wrestling. basketball, judo, wrestling, hapkido, swordsmanship and boxing making indoor gymnasium and exercising room an object, when 7 items were measures such as thermocircumstance(temperature, relative humidity, air current, intensity of illumination), dust, carbon monoxide, and carbon dioxide being based on the indoor environmental standard of the first clause of Article 45 of public utilization service which is showed at public hygiene of the Ministry of Health and Social Affairs, it was showed that indoor temperature, relative humidity, air current and intensity of illumination were over standard amount at the most of folk wrestling gymnasium and exercising room. Indoor density of carbon monoxide was preserved to the extent of standard amount (10ppm) at all gymnasiums but carbon dioxide was not in excess of standard amount(1,000 ppm) at most of gymnasiums. Indoor density of dust induced from respiration exceeded the standard amount (150 $\mu\textrm{g}$/㎥) at all gymnasiums of the folk wrestling. Since the folk wrestling players and participants feel physical subjective symptom seriously, in other words the degree of indoor air pollution at gymnasiums and exercising rooms of the folk wrestling is very high, fundamental solution and countermeasure plan should be presented.

  • PDF

Commercial Indoor Navigation System Technology Movement

  • Seo, Jae-Min;Jang, Beakcheol
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.1
    • /
    • pp.33-40
    • /
    • 2017
  • In this paper, we introduce commercial indoor navigation systems being deployed and serviced in many fields of industry focusing on their indoor positioning technologies. Indoor positioning technology is a technology that locates people or targets in the interior of a building. To do that, it utilizes radio waves such as WiFi, and bluetooth, magnetic fields, or other sensory information from smart phones. We present indoor navigation systems categorizing them into their indoor positioning technologies. We define important performance issues for indoor positioning technologies and analyze them according to the performance issues. We believe that this paper provide wise view and necessary information for recent indoor navigation systems.

Comparison of CityGML and IndoorGML -A Use-Case Study on Indoor Spatial Information Construction at Real Sites- (CityGML과 IndoorGML의 비교 -실내공간정보 구축 사례 고찰-)

  • Li, Ki-Joune;Kim, Tae-Hoon;Ryu, Hyung-Gyu;Kang, Hae-Kyong
    • Spatial Information Research
    • /
    • v.23 no.4
    • /
    • pp.91-101
    • /
    • 2015
  • Due to recent increase of indoor spatial information demands, several international standards have been published for indoor spatial information. OGC has also recently published two standards for indoor space; CityGML and IndoorGM. CityGML aims to provide a standard for 3D city modeling and the level of details (LoD) 4 covers the indoor space. IndoorGML focuses only on indoor space and provides several functions to complement the weakness of CityGML. It is therefore recommended to apply IndoorGML as a combination with CityGML. However since the weakness and strengths between these standards are not yet fully studied and understood, there is no well-defined guideline to apply them in a proper way. It means that we need to carry out a comparative study between them for their proper integration. For this reason, we discuss the pros and cons of these standards from two use-cases. The sites for the use-cases cover Lotte World Mall and Jongno-5 subway station, respectively. We studied these use-cases to compare CityGML and IndoorGML through the data construction of CityGML and IndoorGML for these sites. And based on several application scenarios, we also analyzed the weakness and strengths of each standard from different viewpoints. We expect that these comparative studies will be helpful to make a guideline on the application and integration between CityGML and CityGML.

Localization for Mobile Robot by Selective Anchors in Indoor GPS and EKF (선택적 Anchors 기반 Indoor GPS 및 EKF를 이용한 이동 로봇 위치 추정)

  • Kang, Han-Goo;Yun, Jae-Oh;Lee, Ji-Hong
    • The Journal of Korea Robotics Society
    • /
    • v.6 no.1
    • /
    • pp.58-68
    • /
    • 2011
  • This paper proposes a technique of indoor localization for mobile robot by so called indoor GPS and EKF. Basically the concept of indoor GPS is similar outdoor GPS, and the indoor GPS gets distances between Anchors and Tag by a ranging method of CSS and then estimates the coordinate by distances and known Anchor positions. After we performed performance test of indoor GPS system in ideal and multipath environment, we configured that the indoor GPS has internal error factors and external error factors. This paper handled a multipath problem belonging to external error factors. At first various direct physical method are introduced to fix the multipath problems, and as expected we got errors corrected considerably. And then the method of selective anchors for indoor GPS is applied. With these two level improvement of indoor GPS performance, EKF(Extended Kalman Filter) is applied to mobile robot in indoor environment. The usefulness of the proposed methods are shown by a series of experiments in a environment giving contaminated data by multipath.

Evaluation Method for Improvement of Indoor Air Quality Using Mass Balance (물질수지를 이용한 실내공기질 개선정도 평가)

  • Kim, Young-Hee;Kim, Moon-Hyeon;Yang, Won-Ho
    • Journal of Environmental Science International
    • /
    • v.15 no.10
    • /
    • pp.913-918
    • /
    • 2006
  • Despite the wide distribution of air pollutants, the concentrations of indoor air pollutants may be the dominant risk factor in personal exposure due to the fact that most people spend an average of 80% of their time in enclosed buildings. Researches for improvement of indoor air quality have been developed such as installation of air cleaning device, ventilation system, titanium dioxide$(TiO_2)$ coating and so on. However, it is difficult to evaluate the magnitude of improvement of indoor air quality in field study because indoor air quality can be affected by source generation, outdoor air level, ventilation, decay by reaction, temperature, humidity, mixing condition and so on. In this study, evaluation of reduction of formaldehyde and nitrogen dioxide emission rate in indoor environments by $TiO_2$ coating material was carried out using mass balance model in indoor environment. we proposed the evaluation method of magnitude of improvement in indoor air quality, considering outdoor level and ventilation. Since simple indoor concentration measurements could not properly evaluate the indoor air quality, outdoor level and ventilation should be considered when evaluate the indoor net quality.

Indoor Environmental Efficiency Indoor Garden in Apartment House during Winter (아파트 실내정원의 겨울철 실내온열환경 조절효과)

  • Kim, Jeong-Min;Choi, Yoon-Jung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.05a
    • /
    • pp.212-216
    • /
    • 2005
  • The purpose of this study is to make clear the indoor thermal environmental efficiency of indoor garden in apartment during winter. The questionnaire survey was carried out during the l0th${\sim}$20th of February 2004, respondents consisted of 215 residents living in a subject apartment estate. The field measurements of indoor thermal elements were carried out at A house with indoor garden and at B house without indoor garden. The measurements in two-subject houses were taken on simultaneously the 11th of February. As Results, the residents living in apartments with indoor garden show positive response on air moisture and satisfaction. The daily ranges of indoor temperature and globe temperature in the A house were narrower than the B house. The average relative humidity in the A house was higher and constant than the B house. Therefore, it was seemed that indoor environment during winter in the house with indoor garden maintained more constant or comfortable than the house without indoor garden by earning effect and humidity control effect of plants.

  • PDF

An Analysis about Recognition of Indoor Air Quality of Workers at Dental Clinics in Jeollanamdo Area

  • Choi, Mi-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.11
    • /
    • pp.137-142
    • /
    • 2018
  • The purpose of this study is to contribute to the improvement of indoor air quality management in dental clinic by investigating the level of indoor air quality recognition among dental clinic workers. The questionnaire survey was conducted for about 4 weeks from May 20 to June 20, 2018 in dental clinics located in Jeollanamdo area and 143 were used as the analysis data. The method of indoor air quality management in dental clinic was preferred to "natural ventilation" method and the number of natural ventilation was 1 to 2 times per day and the results of survey on indoor environment satisfaction showed that satisfaction level was lowest in noise and smell items. The types of subjective symptoms experienced by workers working at dental clinics are "cough", "eye burn", and "headache" and a survey on the degree of the relationship between subjective symptoms and indoor air quality showed that 94.4% (135) of respondents answered "very relevant" and "slightly related". As a result of multiple regression analysis, the variables affecting the indoor air quality satisfaction of the dental clinic staff were analyzed as the items such as lighting, noise, main work, number of patients, comparing indoor and outdoor air quality and among them, "comparing indoor and outdoor air quality" was analyzed as having a great influence. To improve the indoor air quality satisfaction of dental clinic worker adequate ventilation, designate the person responsible for the indoor air quality management and periodic measurement efforts will be necessary.