• Title/Summary/Keyword: Individual tooth tray technique

Search Result 4, Processing Time 0.017 seconds

A STUDY ON ACCURACY AND DIMENSIONAL STABILITY ACCORDING TO IMPRESS10N METHODS (인상채득방법과 방향에 따른 인상체의 정밀성과 체적 안정성에 관한 연구)

  • Lee, Jae-Young;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.567-580
    • /
    • 1999
  • Accurate reproduction of intraoral tissue is essential in the fabrication of fixed prosthesis. This selection of impression material and method is very important. In this study, vinyl polysiloxane type impression material $Panasil^{(R)}$ was used. Three impression methods ; one-step technique, individual tray technique, and individual tooth tray technique using the vinyl polysiloxane type bite registration material $Futar^{(R)}$ Occlusion, were used to take horizontal and vertical impression. Improved stone models were fabricated. The amount of occlusal surface discrepaneies, interabutment distance discrepancies, amount of marginal defect were evaluated with the $X-PLAN360d^{(R)}$ and photoscanning. The results were as follows. 1. There was no significant difference in occlusal surface according to the directions and techniques of impression taking. 2. There was no significant difference in interabutment distance discrepancies according to the directions and techniques of impression taking 3. There was no significant difference in marginal discrepancies according to the direction of impression taking but there was significant difference between one-step technique and individual tray technique, individual tooth tray technique (P<0.05). Taken together, these results suggest that individual tray technique and individual tooth tray technique are more accurate for impression taking than one-step technique.

  • PDF

A STUDY ON THE ACCURACY OF THE IMPRESSION BODY ACCORDING TO MATERIALS AND FORMS OF THE INDIVIDUAL TOOTH TRAY (개별 치아 트레이의 재료와 형태에 따른 인상체의 정밀성에 관한 연구)

  • Ryu, Duck-Woo;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.242-254
    • /
    • 2000
  • Accurate impression is very important to achieve desirable prosthesis and there are many factors in taking a good impression. For example, types of impression material, types of impression tray, impression taking methods and so on. Recently individual tooth tray technique is accepted as obtaining good impression that can be applied to multiple abutment impression, heavy salivated patient, to minimize the effect of natural teeth s undercuts and to reduce pain during cord packing procedures. The purpose of this study was to compare the accuracy according to materials and forms of the individual tooth tray which is clinically applied nowadays. Used materials in experiment were divided into 3 types (acrylic resin. $Futar^{(R)}$ occlusion. $Blu-mousse^{(R)}$) and forms were divided into 2 types (forming occlusal vent hole or not and forming marginal vent space or not). Stone master model from impression body and metal master model were measured by $X-PLAN360d^{(R)}$ to compare occlusal surface discrepancy and marginal discrepancy. The results were as follows: 1. In comparison of occlusal surface discrepancy and marginal discrepancy according to materials, groups with three materials showed no statistical difference 2. In comparison of occlusal surface discrepancy and marginal discrepancy according to occlusal vent hole, groups with occlusal vent hole showed significantly less marginal discrepancy than groups with no occlusal vent hole(p<0.05). 3. In comparison of occlusal surface discrepancy and marginal discrepancy according to 0.5mm-marginal-vent-space, groups with no 0.5mm-marginal-vent-space showed significantly less marginal discrepancy than groups with 0.5mm-marginal-vent-space (p<0.05). In summary these results suggest that individual tooth tray made of 3 types of materials with occlusal vent hole and individual tooth tray made of acrylic resin with no marginal vent space showed good accuracy of impression. In addition, individual tooth tray which is made of bite registration materials may be more useful because of advantage in facility and timesaving aspect of fabrication.

  • PDF

Fabrication of denture by using the individual tray duplicated an existing denture through 3D printing: A case report (3D 프린팅을 통해 기존의치를 복제하여 개인트레이로 활용한 총의치 제작 증례)

  • Park, Juyoung;Park, Sangwon;Lim, Hyun-Pil;Park, Chan;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.508-514
    • /
    • 2021
  • In this report, Replicated denture was fabricated by 3d printing after scanning the existing denture. It was used as an individual tray in closed-mouth technique. It reduced laboratory process and clinical time. Also it helped in facial evaluation and tooth arrangement. Compared to open-mouth technique, the number of visits was reduced, and the patient's adaptability to new denture was enhanced by utilized various information of the existing denture, including vertical dimension.

Fabrication of complete denture using conventional method and monolithic digital denture system: a case report (전통적 제작법과 모놀리식(monolithic) 디지털 의치 시스템을 이용한 상·하악 총의치 동시 수복 증례)

  • Young-Baek Park;Ga-Hyun Lee;Young-Gyun Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.6-19
    • /
    • 2024
  • With the advancement of Computer-Aided Design/Computer-Aided Manufacturing (CAD-CAM) technology, fabrication of dentures using this technology has gained popularity. As one of CAD-CAM technologies, digital complete denture system has been introduced, which fabricates complete dentures using subtractive manufacturing of monolithic block containing both the color of a denture base and an artificial tooth. In this case, two pairs of upper and lower dentures were fabricated for two patients. Two pairs of complete dentures were fabricated for a 74-year-old male and a 73-year-old female respectively by conventional denture fabrication method and digital method of milling. To obtain a digital complete denture, monolithic block (Ivotion, Ivoclar Vivadent, Schaan, Liechtenstein) was chosen for the materials to fabricate the digital complete dentures. An individual tray was designed using CAD software and manufactured by 3D printing technique. The final impression and interocclusal relationship were recorded using the fabricated individual tray. The final impression was scanned, and the complete denture design and try-in denture were 3D printed using CAD-CAM software. Subsequently, the monolithic block was milled, and the final dentures were fabricated and tried on patients. Previously mentioned two patient cases compared and analyzed stability, fit, speaking, mastication, aesthetics, and patient satisfaction of two pairs of dentures: one fabricated using CAD-CAM system and the other using traditional methods. This was performed to evaluate and report the findings from both denture-making approaches.