• 제목/요약/키워드: Individual measurements

검색결과 520건 처리시간 0.022초

2-프로판올-물 혼합용매에서의 Tetraalkylammonium Chlorides의 분몰랄 부피 (Partial molal volumes of tetraalkylammonium chlorides in isopropanol-water mixtures)

  • 조병린
    • 대한화학회지
    • /
    • 제15권2호
    • /
    • pp.95-105
    • /
    • 1971
  • The apparent molal volumes ${\phi}_v$ of a series of homologous tetraalkylammonium chlorides, $Me_4NCl, Et_4NCl, Pr_4NCl,\;and\;Bu_4NCl$, in a series of isopropanol-water mixtures have been determined at $30^{\circ}C$ from precision density measurements using pycnometers. The values of ${\phi}_v$ extrapolated to infinite dilution give partial molal volumes $\={V}^{\circ}$s which are almost additive for successive homologues and enable one to determine the absolute individual ionic partial molal volumes. The experimental results are discussed in terrns of the varying size and surface charge of the ions and the structure of the binary solvent mixtures. The results indicate that at 0.1 mole fraction isopropanol the maximum structuredness of water causes a minimum in the tetraalkylammonium-cation partial molal volumes, while at 0.2 mole fraction the solvent structure is such that the free volumes is a minimum and the electrostrictive effect of chloride ion is a maximum.

  • PDF

해저 150m Heliox 포화잠수시의 수면변화 (Changes in sleep during a simulated Heliox saturation deve to 150m)

  • 서유진;;;박영만;정민상
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1997년도 추계학술대회논문집
    • /
    • pp.414-425
    • /
    • 1997
  • Standark polysomnograms, and questionnaires were measured using 4 subjects during simulated 150m heliox saturation dives. These measurements were performed on 4 pre-dive nights, 8 bottom nights, 6 decompression nights and post decompression nights. Sleep disturbances caused by frequent awakening were found throughout the dive period, but the disturbances were more intense on the second and fourth nights at the bottom and on the third and fourth nights of decompression. Stage 4 of sleep decreased every night at the bottom and from the first through third nights of decompression. The subjective self-evaluation of sleep was in agreement with the physiological variables. Complaints of subjective feeling of fatigue slightly increased throughout the dive period. It could be surmised that sleep disturbance or fatigue was not as significant under the 150m deep hyperbalic environment of He-O/ sub 2/ mixture, and therefore should be able to be coped with partially, through there moght be individual differences in adaptation.

  • PDF

기능적전기자극에 의한 체간제어의 기초적인 연구 (FUNDAMENTAL STUDY FOR ROLLING-OVER MOTION OF THE BODY BY FUNCTIONAL ELECTRICAL STIMULATION(FES))

  • 이준하;호시미야
    • Journal of Yeungnam Medical Science
    • /
    • 제7권2호
    • /
    • pp.103-108
    • /
    • 1990
  • 기능적전기자극(FES)을 이용하여 중추신경장해환자의 체간제어를 행하는 방법을 고안하여 체간제어에 필요한 각 각의 관절운동을 실현시켜 보았다. 건강인에게 전기자극실험을 행하고 기능적전기자극애 의해 체위변환의 실현가능성을 검증했다. 또한 상지를 함께 이용한 체위변환시의 근전도를 해석하여 보다 적절한 체위변환의 방법을 검토했다.

  • PDF

Switchable Uncompensated Antiferromagnetic Spins: Their Role in Exchange Bias

  • Lee, Ki-Suk;Kim, Sang-Koog;Kortright J.B.;Kim, Kwang-Youn;Shin, Sung-Chul
    • Journal of Magnetics
    • /
    • 제10권1호
    • /
    • pp.36-39
    • /
    • 2005
  • We report element-resolved and interface-sensitive magnetization reversals investigated from an oppositely exchange-biased NiFe/FeMn/Co structure by employing soft x-ray resonant Kerr rotation measurements. We have found not only switchable uncompensated antiferromagnetic regions with its sizable thicknesses at both interfaces of the FeMn layer but also their strong coupling to the individual ferromagnetic layers. These experimental results provide a better insight into experimentally observed reductions in exchange-bias field on the basis of an interface-proximity model proposed in this work.

Optimal Region of Interest Location of Test Bolus Technique in Extra Cranial Carotid Contrast Enhanced Magnetic Resonance Angiography

  • Choi, Kwan-Woo;Na, Sa-Ra;Son, Soon-Yong;Jeong, Mi-Ae
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.234-237
    • /
    • 2017
  • This study is aimed to optimize a location of region of interest (ROI) in test bolus carotid contrast enhanced magnetic resonance angiography (CE-MRA) at 3.0T. A total of consecutive 270 patients with no cardiovascular and vessel diseases were selected. Patients underwent elliptical centric 3D CE-MRA with the test bolus technique to identify the individual arterial arrival time. Quantitative measurements were performed by drawing ROIs of $25mm^2$ and signal intensities (SI) were measured in the center of common carotid artery (CCA), internal carotid artery (ICA) and aortic arch (AA). As a result, ROIs located within AA showed a significantly clarified arterial peak and over three times increased SI, while no significant arterial peak time differences were observed compared to ROIs located within CCA. In conclusion, it was demonstrated that the aortic arch is the optimal position to locate ROI in test bolus images of the carotid CE-MRA.

클러터 환경에서 다중센서 정보융합을 통한 유도성능 개선 연구 (A Study of Missile Guidance Performance Enhancement using Multi-sensor Data Fusion in a Cluttered Environment)

  • 한두희;김형원;송택렬
    • 제어로봇시스템학회논문지
    • /
    • 제16권2호
    • /
    • pp.177-187
    • /
    • 2010
  • A MTG (Multimode Tracking and Guidance) system is employed to compensate for the limitations of individual seekers such as RF (Radio frequency) or IIR (Imaging Infra-red) and to improve the overall tracking and guidance performance in jamming, clutter, and adverse weather environments. In the MTG system, tracking filter, data association, and data fusion methods are important elements to maximize the effectiveness of precision homing missile guidance. This paper proposes the formulation of a Kalman filter for the estimation of line-of-sight rate from seeker measurements in missiles guided by proportional navigation. Also, we suggest the HPDA (Highest Probability Data Association) and data fusion methods of the MTG system for target tracking in the adverse environments. Mont-Carlo simulation is employed to evaluate the overall tracking performance and guidance accuracy.

한국 젊은여성의 심미적 안모형태에 관한 두부방사선 계측학적 연구 (A CEPHALOMETRIC ANALYSIS ON FACIAL ESTHETICS OF KOREAN YOUNG ADULT FEMALE)

  • 노준;유영규
    • 대한치과교정학회지
    • /
    • 제18권1호
    • /
    • pp.127-139
    • /
    • 1988
  • Esthetic is one of the prime goal of the orthodontic treatment. It is represented by the word of harmony or balance. There is no absolute esthetic norm but it is important to study about it in orthodontic and orthognatic surgical treatment planning. The purpose of this study is to obtain the norm of Korean female adolescents who were candidates of 1986, 1987 Miss Korea Beauty Contest. The 77 individual samples were selected and studied by cephalometric analysis. Obtained results were as follows: 1 Korean esthetic norm was obtained. 2. Simple correlation coefficient was obtained between each measurements. 3. Holdaway ratio of Korean beauty was 3.3 : 1. 4. To compare with caucasian, profile of Korean beauty had less prominant nose, more prominant lip and deeper sulcus depth.

  • PDF

액체의 유전상수 정밀측정용 크로스 커패시터 전극 개발 (Development of a Cross Capacitor Electrode for Measurements of Liquids Dielectric Constants)

  • 김한준;이래덕;강전홍;;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.675-678
    • /
    • 2000
  • Using the principle of the cross capacitor, a precise system for measuring the electric constants of liquids has been developed. The four electrodes of the cross capacitor were formed around fused-silica tube by plating a gold film. The effect of a non-uniform tube wall ok the measured permittivity was investigated As the individual characteristics of the tubes were determined to be constant, the pure dielectric constants extracted from any effect of the fused-silica material could be precisely derived with uncertainty of less than ${\pm}$ 0.02∼0.05 %.

  • PDF

Stereoscopic PTV 기법의 개발과 성능비교 연구 (Development of Stereoscopic PTV Technique and Performance Tests)

  • 이상준;윤전환
    • 대한기계학회논문집B
    • /
    • 제30권3호
    • /
    • pp.215-221
    • /
    • 2006
  • A stereoscopic particle tracking velocimetry (SPTV) technique based on the 2-frame hybrid particle tracking velocimetry (PTV) method was developed. The expansion of 2D PTV to SPTV is facilitated by the fact that the PTV method tracks individual particle centroids. To evaluate the performance and measurement accuracy of the present SPTV technique, it was applied to flow images of rigid body translation and synthetic standard images of jet shear flow and impinging jet flow. The data processing routine and measurement uncertainty of the SPTV technique are compared with those of conventional stereoscopic particle image velecimet.y (SPBV). In addition, the centroid translation effect of 2D particle image velocimetry (PIV) is defined and its effect on SPIV measurements is discussed. Compared to the SPIV method, the SPTV technique has inherited merits of concise and precise velocity evaluation procedures and provides better spatial resolution and measurement accuracy.

재구조화된 콜로이드 실리카 응집체에 대한 광 산란 (Light scattering from restructured colloidal silica aggregates)

  • 임영훈
    • 한국광학회지
    • /
    • 제3권3호
    • /
    • pp.167-171
    • /
    • 1992
  • 소금물에 유도된 콜로이드 실리카 응집체의 재구조에 대한 정적 및 유동 광산란 결과를 나타냈다. 또한 투과전자현미경을 이용한 사진결과로부터 입자들 각각의 크기 및 그물 모양으로 갈라진 응집체에 관한 미세구조를 확인하였다. 재구조화된 실리카 응집체에 대한 프랙탈 차원들은 현상태 광산란 측정결과들과 상당히 달랐다. 소금물에 유도된 0.5wt.% 농도의 Ludox-AM에 대한 프랙탈 차원 $D_{F}$는 2.21로 측정되었다. 0.1wt.% 농도의 Ludox-AM에 대한 Rayleigh 선폭을 논의한다.

  • PDF