• Title/Summary/Keyword: Individual Variation

Search Result 842, Processing Time 0.029 seconds

Surface Elevation Recovery Methods from Pressure Gage for Irregular Waves (불규칙파(不規則波에) 대한 압력식(壓力式) 파고계(波高計)의 적용성(適用性)에 관한 연구(研究))

  • Kwon, Jung Gon;Kang, Ju Bok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4_1
    • /
    • pp.129-136
    • /
    • 1992
  • A precedure for recovering surface displacement from a time series of pressure measured by a pressure gage in a shallow water (that is, FFTM, LCM. IWM) is investigated with respect to a proper cut-off-frequency of a frequency response function for the accurate recovery of wave height and period. The authors examined the applicability of above mentioned three transformation procedures through field observations and laboratory experiments and the following results are obtained. i) The cut-off-frequency of the frequency response function used in FFTM is deeply depend on both the frequency response of the pressure sensor and the water depth at the sensor. In this study, a relatively accurate surface displacement can be recovered when the frequency response function is cut off at the frequency corresponding to kh=3.0 where k is a wave number at the depth of h. The frequency response function in the region higher than the cut-off-frequency is set constant to be the value at the cut-off-frequency. ii) The transformed surface displacements by LCM are affected by the small waves of short periods included in the measured pressure. It is found that pressure variation whose local frequency is higher than kh=1.5 has to be neglected to recover surface displacement sufficiently. iii) In IWM, the linear pressure response function is usually utilized by multiplying a coefficient N which is a function of the frequency (or kh) and takes a value around unity. However, in this study, a constant value of N(=1.0) gives a relatively accurate recovery of surface displacements.

  • PDF

Genetic Status of ESR Locus and Other Unidentified Genes As sociated with Litter Size in Chinese Indigenous Tongcheng Pig Breed after a Long Time Selection

  • Zhu, M.J.;Yu, M.;Liu, B.;Zhu, Z.Z.;Xiong, T.A.;Fan, B.;Xu, S.P.;Du, Y.Q.;Peng, Z.Z.;Li, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.5
    • /
    • pp.598-602
    • /
    • 2004
  • The Tongcheng pig breed is a famous Chinese indigenous breed. The Ministry of Agriculture of China has filed it as 1 of 19 national key conservation breeds selected from more than 100 Chinese indigenous pig breeds in 2000. In order to improve the reproductive performance, it has been intensively selected to increase the litter size for about 10 years. The population randomly sampled from conservation nucleus of eight families in the Tongcheng pigs was genotyped for identification of their estrogen receptor locus polymorphisms with the PCR-RFLPs method. Only AB heterozygotes and BB homozygotes were detected, and $X^2$ test demonstrated that the locus was in disequilibrium at a significant level (p<0.05). In the present paper, the litter sizes in different parities were regarded as different traits. Holistic status of other unspecific and unidentified genes was estimated by using the statistical methods. Coefficients of kurtosis and skewness showed that the litter size still presented segregating characteristic in the 2nd, 5th, 7th, 8th and 9th parities. Analysis of homogeneity of variance between families confirmed the results for the 5th, 7th and 8th parities. The heritability of litter size for the 1st to 10th parities was estimated with paternal half-sib model and individual estimated breeding values (EBVs) were evaluated by a single trait animal model as well. We found that the averages of EBVs for litter size in each parity did not differ significantly between genotypes, despite the significant difference for original phenotype records in the 3rd, 4th and 5th parities (p<0.05 or p<0.01). The results may be explained by the deduction that the polymorphisms of ESR locus are no longer the important genetic base of litter size variation when the frequency of allele B accumulated in the experience of selection procedure, and further conferring that there exist special genes associated with litter size in the recent Tongcheng pigs population can be made.

Feeding Trials to Compare Theoretical Accuracy between Apparent and True Metabolizable Energy Systems in Chick Diets (병아리 사료에서 일반대사에너지와 순대사에너지의 이론적 정확성 비교를 위한 실험)

  • 지규만
    • Journal of Nutrition and Health
    • /
    • v.25 no.7
    • /
    • pp.543-554
    • /
    • 1992
  • True metabolizable energy(TME) is believed a better indicator for animal performance than apparent metabolizable energy (AME) for excluding the endogenous energy losses from excreta, However few researches have been conducted to compare superiority of any energy systems through practical animal feeding tests. Present study was to compare the energy systems in young chicks in terms of predictability of energy intake for the birds performances including body energy retention and of methodological accuracy by evaluating reproducibility and additi-vity of energy values of feed ingredients and compound diets. Five ingredients such as yellow corn wheat soybean meal fish meal and wheat bran were measured for their various biological energy values. in the first feeding trial chicks were restric-ted-fed the basal diet at 80, 60 and 40% on weight basis of the amount of feed ingested by chicks fed ad libitum the same diet. chicks in the second trial were also restricted-fed diets at levels of 80, 70, 60 and 50% on energy basis of the amount consumed by the basak duet group fed ad libitum The diets in the latter trial were however composed of differeent formulations from the basal diet. One-week-old Single Comb White Leghorn male chicks were individually alloted in a cage on 10 cages/treatment basis and fed the diets for 14 days. Individual carcass energy was measured after the feeding trials. Coefficients of variation of energy measurements were lesser for nitrogen-corrected AME and TME(AMEn & TMEn respectively) than AME and TME values suggesting taht reprodu-cibility of energy determinations by former systems could be better than the latters. The coeffi-cients for AME and TME were almkost of the same values. Additivity obtained by the rations between the calculated values and catual measurements appeared quite satisfactory for all the energy systems. Those of AME and TME however were relatively better than the other systems. Regression coefficient ${r}^2$ between energy intake by various systems and chick performances appeared higher for TME, AMEn and TMEn than AME implying that the former systems could provide better predictability for body weight gain and energy retention than the AME. The ${r}^2$ values for TME and AMEn particularly for body weight gain were on the average 0.967 and 0.960 respectively. In conclusion TME or AMEn can be recommended as choice for dietary energy system in terms of performance predictability of the birds and of procedural convenience for the measurements.

  • PDF

Monitoring Feeding Adequacy in Dairy Cows Using Milk Urea and Milk Protein Contents under Farm Condition

  • Dhali, A.;Mehla, R.K.;Sirohi, S.K.;Mech, A.;Karunakaran, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.12
    • /
    • pp.1742-1748
    • /
    • 2006
  • The experiment was conducted on 264 crossbred Karan-Fries (Holstein Friesian${\times}$Tharparkar) cows, over one year to explore the possibility of using milk urea (MU) concentration and milk protein content to monitor feeding adequacy under farm condition and to investigate the effects of different animal factors and season on MU concentration. Individual noon (1200 to 1300 h) milk samples were collected once in every month and analysed for urea and protein contents. Representative feed samples were also collected on the same day of milk collection and were analysed for CP content. A significant positive association (p<0.01) between MU concentration and milk yield was observed. MU concentrations (mg/dl) were found to be significantly (p<0.01) higher and lower in first lactation (44.8${\pm}$0.7) and in early lactation stage (40.7${\pm}$0.5), respectively. Average MU values were found to be significantly (p<0.01) higher in winter (50.7${\pm}$0.3) and lower in summer (32.9${\pm}$0.6). During the investigation, of the total MU observations, 50.3% were within the range of 30 to 50 mg/dl, 21.4% were <30 mg/dl and only 7.5% were >60 mg/dl. MU concentration was found to be associated significantly (p<0.05) with CP content of forages rather than concentrate. A close positive association (p<0.01) between MU level and daily milk protein (DMP) yield was observed during the investigation. The regression equation, DMP yield (g) = -24.6+33.5 daily milk yield (kg) +0.9 MU (mg/dl) was developed to establish the reference level of DMP yield. The result indicates that the effect of parity and stage of lactation may be ignored while interpreting MU values. However, reference MU values may be standardised separately for high milk yielders as level of milk yield contributes significantly to the variation of MU. The study revealed that the MU values together with DMP yield and milk protein content could be used as a potential non-invasive pointer to monitor feeding adequacy in dairy cows under farm conditions.

Principal Milk Components in Buffalo, Holstein Cross, Indigenous Cattle and Red Chittagong Cattle from Bangladesh

  • Islam, M.A.;Alam, M.K.;Islam, M.N.;Khan, M.A.S.;Ekeberg, D.;Rukke, E.O.;Vegarud, G.E.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.6
    • /
    • pp.886-897
    • /
    • 2014
  • The aim of the present study was to get a total physical and chemical characterization and comparison of the principal components in Bangladeshi buffalo (B), Holstein cross (HX), Indigenous cattle (IC) and Red Chittagong Cattle (RCC) milk. Protein and casein (CN) composition and type, casein micellar size (CMS), naturally occurring peptides, free amino acids, fat, milk fat globule size (MFGS), fatty acid composition, carbohydrates, total and individual minerals were analyzed. These components are related to technological and nutritional properties of milk. Consequently, they are important for the dairy industry and in the animal feeding and breeding strategies. Considerable variation in most of the principal components of milk were observed among the animals. The milk of RCC and IC contained higher protein, CN, ${\beta}$-CN, whey protein, lactose, total mineral and P. They were more or less similar in most of the all other components. The B milk was found higher in CN number, in the content of ${\alpha}_{s2}-$, ${\kappa}$-CN and ${\beta}$-lactalbumin, free amino acids, unsaturated fatty acids, Ca and Ca:P. The B milk was also lower in ${\beta}$-lactoglobulin content and had the largest CMS and MFGS. Proportion of CN to whey protein was lower in HX milk and this milk was found higher in ${\beta}$-lactoglobulin and naturally occuring peptides. Considering the results obtained including the ratio of ${\alpha}_{s1}-$, ${\alpha}_{s2}-$, ${\beta}$- and ${\kappa}$-CN, B and RCC milk showed best data both from nutritional and technological aspects.

Optimal arrangement of multiple wind turbines on an offshore wind-wave floating platform for reducing wake effects and maximizing annual energy production (다수 풍력터빈의 후류영향 최소화 및 연간발전량 극대화를 위한 부유식 파력-해상풍력 플랫폼 최적배치)

  • Kim, Jong-Hwa;Jung, Ji-Hyun;Kim, Bum-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.209-215
    • /
    • 2017
  • A large floating offshore wind-wave hybrid power generation system with an area of 150 m2 and four 3 MW class wind turbine generators was installed at each column top. In accordance with the wind turbine arrangement, the wake generated from upstream turbines can adversely affect the power performance and load characteristics of downstream turbines. Therefore, an optimal arrangement design, obtained through a detailed flow analysis focusing on wake interference, is necessary. In this study, to determine the power characteristics and annual energy production (AEP) of individual wind turbines, transient computational fluid dynamics, considering wind velocity variation (8 m/s, 11.7 m/s, 19 m/s, and 25 m/s), was conducted under different platform conditions ($0^{\circ}$, $22.5^{\circ}$, and $45^{\circ}$). The AEP was calculated using a Rayleigh distribution, depending on the wind turbine arrangement. In addition, we suggested an optimal arrangement design to minimize wake losses, based on the AEP.

Surface Dose and Transmission Factor for Vacuum Cushion (Vacuum Cushion 사용시 표면선량과 투과율 평가)

  • 김미화;이병용;전미선
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.74-78
    • /
    • 2002
  • The individual (customized) immobilization has been used to reproduce the patients' set-up on daily base. There are many various devices available commercially. To evaluate dosimetric characteristics of vacuum cushion, we analysed the surface dose and transmission factor for d$_{max}$ when patient is immobilized with vacuum cushion. Experiments were performed with 4 MV (Varian 4/100, USA), 6 MV, 15 MV (Varian CL2100C/D, USA) photon beams and five field sizes (5$\times$5, 10$\times$10, 20$\times$20, 30$\times$30, 40$\times$40 $\textrm{cm}^2$) on each occasion. Outputs were measured from surface of polysterene phantom to d$_{max}$ with four different thicknesses of cushion, which is 12, 32, 48 mm and only vinyl without styroforms. As results, the transmission factor for thicknesses of vacuum cushion was ranged from 0.9953 to 1.0043. The more the thickness of vacuum cushion is thick, the more surface dose delivered to patient is increased. The surface dose vary with the thickness of vacuum cushion for energy and field size. The skin reactions may result. But the variation is not serious in the clinic.

  • PDF

Correction of Receiver Gain using Noise′s Standard Deviation for Reconstruction of T$_1$/T$_2$ Maps (T$_1$/T$_2$ maps 의 재구성을 위해 잡음의 표준편차를 이용한 수신 증폭률 보정)

  • 김미나;김성은;신승애;정은기
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.125-131
    • /
    • 1999
  • T$_1$/T$_2$ weighted images are being used to give the characteristic contrast among the various tissues and the norma;/abnormal tissues. Abnormalities in tissues, in general, accompany the biochemical changes and eventually structural ones in which results in the change in T$_1$ and T$_2$ relaxation times of water protons. It has been suggested that the mapping of T$_1$/T$_2$ values may serve as a possible tool for the quantitative evaluation of the degree of abnormality. On reconstructing T$_1$/T$_2$ maps(or any other MR parametric map), only corresponding variables are to be varied, such as TE for T$_2$, TI or TR for T$_1$ and b-factor for diffusion images. But often the receiver gain is taken for the optimal usage of A/D converter, so that the set of the image data has different receiver gain. It must be corrected before any attempt to reconstruct the maps. Here we developed method of correcting receiver gain variation effect, using the standard deviation of noise on individual image. The resultant T$_1$ and T$_2$ values were very comparable to the other reported values.

  • PDF

Cone and Seed Development after Self-pollination in Pinus rigida Mill. (리기다소나무에 있어서 자배(自配) 후(後) 구과(毬果) 및 종자(種子)의 발달(發達))

  • Chung, Min Sup
    • Journal of Korean Society of Forest Science
    • /
    • v.62 no.1
    • /
    • pp.82-86
    • /
    • 1983
  • Cone and seed development after self-pollination in 14-year-old Pinus rigida Mill. was investigated in an $F_1$-hybrid seed orchard that consists of Pinus rigida Mill. and Pinus taeda L. in alternative rows. On an average, 83.8% of the self-pollinated receptive female strobili developed into cones. This value appears to be normal compared to cone development after open-pollination in other pine species such as in Pinus sylvestris L. However, there was a great variation in filled seed development after self-pollination among the investigated individual trees (Table 1-1). The 34.5%, a ratio of filled seeds after self-pollination was significantly lower than 91.7%, that by the open-pollination. Some of the investigated trees developed 70.0%-83.5% of filled seeds after self-pollination. Thus, those are not desirable as trees for seed parent in establishing $F_1$-hybrid seed orchards in future. A further study on the rate of filled seed development by various pollination systems consisting of self-pollination, self-and cross-pollination with intraspecific, mixed (tree's own and foreign pollens) pollens and cross-pollination with interspecific, mixed pollens of the two parental tree species is necessary to determine the quality of seed parent trees in establishing $F_1$-hybrid seed orchards.

  • PDF

Variation of the Number of Empty Seeds per Cone in Pinus koraiensis Sieb. et Zucc (잣나무결실(結實)에 있어서 구과중(毬果中)의 쭉정이량(量)의 변이(變異))

  • Chon, Sang Keun;Chung, Hyun Pae;Hong, Jong Kyun
    • Journal of Korean Society of Forest Science
    • /
    • v.65 no.1
    • /
    • pp.24-30
    • /
    • 1984
  • The average number of empty seeds per cone on the mature tree was $10.03{\pm}0.61$. The ratios of empty seeds to total seeds and to full seeds were $7.38{\pm}0.35%$ and $8.42{\pm}0.49%$, respectively in average. The number of empty seeds per cone and the ratios were varied with the site condition; fruited year, and individual tree. The contribution rates of these sources of variance to the number of empty seeds per cone were respectively 3.50%, 8.06%, and 55.41%. No correlationships were found between the amount of empty seeds in number or ratio and the cone production, and the D.B.H. of mother tree. However, both the number of empty seeds and the ratio of empty seeds to total seeds showed significant positive correlations with the number of 1-year-old cones per tree.

  • PDF