• 제목/요약/키워드: Individual Heating

검색결과 138건 처리시간 0.041초

식품의 조리.가공 공정 중 phytochemical 및 기능성의 변화 (Changes in Phytochemical Stability and Food Functionality during Cooking and Processing)

  • 김현정;전향숙
    • 한국식품조리과학회지
    • /
    • 제22권3호통권93호
    • /
    • pp.402-417
    • /
    • 2006
  • Research interest on functional food and phytochemicals has mainly focused on their health effects, mechanism of action and structure-activity relationship for the development of nutraceuticals. Considering the intake of phytochemicals via the normal diet, further information is required on changes in food functionality or individual phytochemicals that occur during the cooking or processing of foods, in order to increase the intake of these bioactive compounds, because many of the unit-operating procedures involved in cooking or food processing may result in physicochemical changes of food constituents. This study reviews the changes of selected phytochemicals, i.e. flavonoids, organosulfur compounds and carotenoids, or food functionality by major cooking or processing procedures such as heating, fermentation, and pH changes. In general, heating has a negative effect on food functionality, although in some cases, mild heating increases bioactive phytochemical contents. Some phytochemicals, including anthocyanins and catechins, are stabilized in lower pH conditions. The structures of phytochemicals, including isoflavones and catechins, are changed by fermentation. The loss of bioactive compounds may be decreased by recently developed cooking or processing methods such as microwave cooking or use of high hydrostatic pressure. However, the effects of cooking and processing procedures on food functionality and phytochemicals are so diverse and dependent on test conditions that further research efforts are needed to form accurate conclusions on the effects of cooking and processing of foods.

도서관의 공간사용 특성에 따른 냉난방설비 리모델링의 경제성 평가 (Energy Efficiency Evaluation of Heating and Cooling Systems as Space Program in Renovated Library)

  • 박강현;차정훈;김수민;박경원
    • 설비공학논문집
    • /
    • 제24권3호
    • /
    • pp.205-211
    • /
    • 2012
  • Unlike the previous approaches, we analyzed for economic efficiency of renewed heating and cooling systems as the characteristics of space. The purpose of this study is to analysis the energy consumption and economical efficiency of absorption chillers and EHP systems in renovated library. It is important that equipment selection should be considering energy cost as well as space program. In recently, many EHP systems were installed in the building for reducing the energy cost and for seeking the convenience of individual control. In contrast, though absorption chillers have the disadvantage of a central control, absorption chillers are appropriate for the conditions of the library that needs simultaneous operation. The results by payback period method, show that selection of heating and cooling systems should be consider for space program and the characteristics of space.

고밀도 패턴드 미디어의 자성 특성 평가에 관한 연구 (The Study on Magnetic Analysis of High Density Patterned Media)

  • 이남석;한정원;최의선;한윤성;홍종일;강신일
    • 정보저장시스템학회논문집
    • /
    • 제3권3호
    • /
    • pp.144-148
    • /
    • 2007
  • In this paper, we analyzed the effect of the pattern height on the readback signal characteristics of the magnetic nanopillar tops and trench bottoms. In addition, we discuss the applicability of the present method to the production of patterned magnetic media, which can be obtained by depositing magnetic thin films on the molded nanopillars with passive heating. We found that the individual magnetic island deposited on each molded nanopillars with passive heating is a single magnetic domain and confirmed that its magnetization can be successfully reversed by applying an external magnetic field.

  • PDF

주상복합의 실외기 형태에 따른 냉방시스템 성능 평가 (The performance evaluation of outdoor unit cooling system in a residential apartment complex)

  • 경서경;김윤진;임정희;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.263-268
    • /
    • 2008
  • In a residential complex case, the efficiency of land use are maximized, but a variation of external condition such as load in-equality, the increase in wind velocity and solar radiation by a height causes increasing energy in a building. Besides, because of increasing window size for a lighting and a view, it comes heating load in winter and cooling load in summer. A choice of cooling-system is important for this reason. Recently an internal high-rise residential complex installs an air-cooling system and operates individual heating. However, this study applies water-cooling used one public cooling-tower instead of an air-cooling system, also with an efficiency test of an air and a water-cooling system, consider an internal applicability.

  • PDF

Degassing of Aluminum and Aluminum Alloy Powders as Studied by Gas Chromatography

  • Watanabe, Ryuzo;Choi, Duk-Sun;Kawasaki, Akira
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.716-717
    • /
    • 2006
  • Gas release behavior from aluminum and Al 7075 alloy powders during heating in argon was investigated by in-situ gas chromatography. Water vapor, hydrogen, carbon mono-oxide were detected as individual evolution spectra against heating temperature and time. The mechanisms of water and hydrogen evolutions were studied in detail for the determination of effective degassing condition. Magnesium in the alloy powder was found to lower the hydrogen evolution temperature to enhance overall hydrogen release.

  • PDF

A BIPOLAR PLANETARY NEBULA NGC 6537: PHOTOIONIZATION OR SHOCK HEATING?

  • HYUNG SIEK
    • 천문학회지
    • /
    • 제32권1호
    • /
    • pp.55-63
    • /
    • 1999
  • NGC 6537 is an extremely high excitation bipolar planetary nebula. It exhibits a huge range of excitation from lines of [N I] to [Si VI]or [Fe VII], i.e. from neutral atoms to atoms requiring an ionization potential of $\~$167eV. Its kinematical structures are of special interest. We are here primarily concerned with its high resolution spectrum as revealed by the Hamilton Echelle Spectrograph at Lick Observatory (resolution $\~0.2{\AA}$) and supplemented by UV and near-UV data. Photoionization model reproduces the observed global spectrum of NGC 6537, the absolute H$\beta$ flux, and the observed visual or blue magnitude fairly well. The nebulosity of NGC 6537 is likely to be the result of photo-ionization by a very hot star of $T_{eff} \~ 180,000 K$, although the global nebular morphology and kinematics suggest an effect by strong stellar winds and resulting shock heating. NGC 6537 can be classified as a Peimbert Type I planetary nebula. It is extremely young and it may have originated from a star of about 5 $M_{\bigodot}$.

  • PDF

Optical Scattering as a Probe of Local Field Effect in Micron-sized Cds Spheres

  • 김성규;Alan L. Huston;Anthony J. Campillo
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권2호
    • /
    • pp.96-101
    • /
    • 1995
  • The optical properties of individual 3-to 14-micron diameter CdS crystalline spheres embedded in poly(methyl methacrylate) were studied using elastic scattering. The presence of well defined sharp peaks in the 550 to 600 nm elastic scattering spectra confirmed that each microcrystal acts as an optical cavity with cavity quality factors exceeding 104. Such natural resonator microcrystals should lead to greatly enhanced local field effects near the surface of CdS, quantum electrodynamic modification of optical transition rates of nearby species and altered photochemistry. Absorptive heating following high intensity laser irradiation was found to induce a transient washout of the high Q modes.

대학교 강의실 EHP 제어를 이용한 에너지 절약 시스템 (Energy Saving System of EHP Control at the College Lecture Room)

  • 정기범
    • 대한안전경영과학회지
    • /
    • 제16권2호
    • /
    • pp.167-174
    • /
    • 2014
  • Heating and air conditioning system is changing rapidly from the traditional HVAC central supply system to the individual supply system with electrical heat pump system (EHP) in Korean school buildings. The individual supply system has advantages to turn on and off individually and to adjust the thermal comfort separately, but energy is wasted in the unoccupied classroom when the last leaving occupant does not turn off the controller. If the controller is to be off automatically while the classroom is not in use, energy consumption would decrease dramatically. This project aims to cease the unnecessary EHP supply in vacant classroom by inputting the class schedule from the central control room to reduce the energy-spending. Experimental measurements were carried out between the controlled classroom that is turned off when not in use and the uncontrolled room that is turned on continually. Occupant's comfort and energy consumption were measured and compared between the controlled case and the uncontrolled case. The energy consumption of controlled classroom case is 30-60% less than that of the uncontrolled classroom case. This result shows that controlling the cooling supply for the unoccupied classroom using the class schedule can decrease the energy consumption remarkably. This supply control system can be used to conserve energy in school structures like universities.

Accurate determination of minor isotope ratios in individual plutonium-uranium mixed particles by thermal ionization mass spectrometry

  • Lee, Chi-Gyu;Park, Jinkyu;Lim, Sang Ho
    • Nuclear Engineering and Technology
    • /
    • 제50권1호
    • /
    • pp.140-144
    • /
    • 2018
  • Isotopic analyses of plutonium and low-enriched uranium mixtures with particle sizes of $0.6-3.3{\mu}m$ were performed using thermal ionization mass spectrometry with a continuous heating method to verify its effectiveness for the accurate analysis of minor isotopes without sample pretreatment. The mixed particles used in this study were prepared from a mixed solution of plutonium (SRM 947) and uranium (U010, $^{235}U$ 1% enriched) reference materials. The isotope ratios for plutonium in the individual mixed particles, including $^{238}Pu/^{239}Pu$, $^{241}Pu/^{239}Pu$ as well as $^{240}Pu/^{239}Pu$, and $^{242}Pu/^{239}Pu$, were in good agreement with the certified values despite the isobaric interference of $^{238}U$ and $^{241}Am$. The isotope ratios for uranium in the mixed particles also agreed well with the certified values within the range of error. However, the isotope ratios for minor isotopes, such as $^{234}U$ and $^{236}U$, in the particles with diameters of less than approximately $1.8{\mu}m$ could not be measured because numbers of $^{234}U$ and $^{236}U$ atoms in analyzed particles are too low. These results indicate that thermal ionization mass spectrometry with a continuous heating method is applicable for the analysis of trace amounts of plutonium isotopes, including $^{238}Pu$ and $^{241}Pu$, despite the presence of the respective isobars $^{238}U$ and $^{241}Am$ in the microsamples.