• 제목/요약/키워드: Indirect Measurement Values

검색결과 40건 처리시간 0.025초

직접측정치(直接測定値)와 간접측정치(間接測定値)의 결합(調合)에 의한 20대(代) 남성(男性) 상방신(上半身) 대표체형(代表體型) 연구( 硏究) (Representative Male Upper Body types of the 20s by the Combination of Direct and Indirect Measurement Values)

  • 이은지;심부자
    • 패션비즈니스
    • /
    • 제11권4호
    • /
    • pp.135-151
    • /
    • 2007
  • This study is human body measurement of 200 adult males in their 20s by both direct and indirect methods in order to reveal the representative male upper body types. Composition factors of body types were classified while the combination of direct-indirect measurement values was chosen. The following are the findings: 1) The analysis of direct-indirect measurement statistics showed the following results: 173.80cm (height), 69.87kg (weight), 95.58cm (chest girth), $24.67^{\circ}$ (right shoulder angle), and $9.34^{\circ}$ (shoulder width angle). 2) The factor analysis of the body types by direct measurement produced 5 factors: 1 (front length of upper body), 2 (front length of upper body), 3 (back length of upper body), 4 (circumference of upper body), and 5 (shoulders length). These factors accounted for 90.08%. Also, the cluster analysis of factor scores led to 3 types: 1 (33%, short, comparatively wide shoulders and full in the hips), 2 (25.1%, well-developed upper body in tall, inversed triangle), 3 (41%, average height, short upper body). 3) The body-type factor analysis by indirect measurement resulted in 6 factors with the explanation of 83.24%: 1 (rear upper bady thickness), 2 (front upper body width), 3 (front chest thickness), 4 (left-right shoulder angle), 5 (front width of protrusion distance in chest and shoulders), and 6 (neck's front-rear side angle).In addition, the cluster analysis of factor scores brought about 4 types: 1 (15%, well-developed front chest, beardless waist), 2 (23.5%, flat chest, with shoulder, drooping shoulders, strait neck), 3 (39%, with shoulder, curved back), and 4 (22.5%, narrow and thin, curved waist). 4) Among the 118 subjects (75%), 58 subjects commonly appearing in indirect measurement values group and direct measurement values group were chosen the representative body type group according to asterisk indexes. They had the highest frequency in direct type 3 and indirect type 3, whose combination represented the physical characteristics of the representative body types.

다양한 혈압상태에서 직접혈압을 기준으로 HP 자동혈압기와 국산자동혈압기의 정확도 비교 (Accuracy Comparison of Blood Pressure among the Direct Measurement Method and Two Automatic Indirect Measurement Methods in the Patients with Various Blood Pressure)

  • 송효숙;전태국;최은정;김미정
    • 기본간호학회지
    • /
    • 제8권3호
    • /
    • pp.366-378
    • /
    • 2001
  • Objective: The purpose of this study was to identify differences in measurement methods for blood pressure (Direct measurement, HP automatic indirect measurement, and SE 7000 Korean made indirect measurement), and to evaluate the clinical trial of the Korean made automatic indirect blood pressure measurement. Material & Methods: From June, 1999 to February, 2000, fifty five consecutive patients were randomized into hypertension group (n=20), normotension group (n=20), and hypotension group (n= 15). Measuring blood pressure by indirect methods (HP NIBP M 1008B and SE 7000 NIBP Korean made) was done simultaneously in the same arm with arterial line for direct blood pressure measurement (HP M1006A). The procedures were repeated ten times at intervals of 2 minutes. Statistical analysis was Performed using SPSS (version 8.0 for windows) software package. Values were expressed as means and standard deviation and means were compared using t-test. Statistical significance was considered present with a p value less than 0.05. Results: In the hypertension group and noromotension group, the disparity between HP direct measurement and indirect SE 7000 NIBP did not show any differences compared to the disparity between HP direct measurement and indirect HP NIBP. In the hypotension group, the disparity in the diastolic pressure between HP direct measurement and indirect SE 7000 NIBP was significantly different compared to the disparity between HP direct measurement and indirect HP NIBP (p<0.001), however, disparities in systolic pressure did not showed any differences. Conclusion: Direct blood pressure measurement (HP M1006A) can be replaced with indirect blood pressure measurements (HP NIBP M 1008B & SE 7000 NIBP) in normotension and hypertension patients. Korean made indirect measurement was found to be more accurate compared to HP indirect measurement in hypotension Patients, but more study is needed.

  • PDF

Disagreement between direct and indirect blood pressure measurements obtained from minipigs

  • Lee, Won-Jae;Park, Lisa Soyeon
    • 대한수의학회지
    • /
    • 제58권3호
    • /
    • pp.131-136
    • /
    • 2018
  • Blood pressure (BP) measurement plays a pivotal role in veterinary medicine for diagnosing cardiovascular disorders and monitoring anesthesia of animals. Although indirect BP measurement has been widely applied to monitor BP because of its convenience and non-invasiveness, it is still unclear whether indirect BP measurement is compatible with direct BP measurement in minipigs. In addition, the effect of animal posture during BP measurement is not well understood in minipigs despite its importance to cardiovascular performance. Therefore, both systolic and diastolic arterial BPs in minipigs were measured via femoral artery catheterization for direct BP measurement and using a compressive cuff as an indirect BP measurement under the dorsal or right lateral recumbent postures. Numerical values were processed by the Bland-Altman method to calculate the bias ${\pm}$ SD and the limits of agreement (LOA). In accordance with the American College of Veterinary Internal Medicine guidelines, the results between direct and indirect BP measurements were determined as apparent disagreements in both systolic and diastolic arterial BPs under all postures because of large bias ${\pm}$ SD and wide LOA. The results of the present will help prevent misinterpretation of the anesthetized patient's condition during monitoring of BP by indirect measurement.

신장계에 의한 소성변형비 자동측정법의 평가에 관한 연구 (A Study on the Evaluation of the Automatic Measurement Method of Plastic Strain Ratio by Two Extensometers)

  • 김인수
    • 소성∙가공
    • /
    • 제12권5호
    • /
    • pp.504-512
    • /
    • 2003
  • The plastic strain ratios(R-values) of low carbon steel sheets were determined by the automatic strain measurement method using two extensometers, the indirect photo method for the same tensile specimen during tensile test and the indirect method for the specimen after tensile test. The experimental results showed that the measured plastic strain ratios from the automatic strain measurement method using two extensometers coincided with those from the indirect photo method and the indirect method for all tensile specimens. In addition, the strain dependence of plastic strain ratios could be continuously recorded and the anisotropy of the strength coefficient, K, and strain hardening exponent, n, could be automatically calculated in three directions by computer through the use of two extensometers. The experimental results showed that the strain dependence of R-value was related to the anisotropy of strain hardening exponent in low carbon steel sheets.

중국(中國) 20대(代) 남성(男性)의 하반신(下半身) 대표체형(代表體型) 연구(硏究) (The Representative Body Type of Lower Body of Chinese Males in Their 20s)

  • 이소영;심부자
    • 패션비즈니스
    • /
    • 제11권2호
    • /
    • pp.58-75
    • /
    • 2007
  • This study held human measurement for 200 male subjects in their twenties in full age living in Ningbo City, Zhejiang Province in China. Their lower body types were classified and grouped according to shapes and sizes. Consequently, representative body type reflecting shapes, sizes, and characteristics were chosen and presented with their measurement values to be used as the basic data for slacks pattern making and fitness evaluation. The following are the results of the analysis: 1. Homogeneity analysis was given to determine the correspondence relationships among index types, indirect types, and size types. Index Type 1 (H-Round), Indirect Type 2 (Adjacent Straight Legs & Slight Slant of Lateral Lower Body), and Size Type 1 (Medium-Thick) were correlated; Index Type 2 (A-Trapezoid), Indirect Type 1 (Bow Legs & Slight Slant of Lateral Lower Body), and Size Type 3 (Small-Slim) were corresponded; Index Type 3 (A-Balance), Indirect Type 3 (Balance Legs & Large Slant of Lateral Lower Body), and Size Type 2 (Tall-Normal) were mutually related. 2. Mahalanobis distance based on each shape factor (index or indirect) and size factor (absolute) was obtained, while an index-absolute representative body type group (47 people, 24.4%) and an indirect-absolute representative body type group (45 people, 23.7%) were chosen, each reflecting shapes, sizes, and characteristics. 3. The representative body type group of lower body shapes of Chinese males in their 20s had average measurement values, such as 169.15cm (stature), 73.32cm (waist circumference), 75.76cm (omphalion waist circumference), 91.08cm (hip circumference), 106.02cm (outside leg length), 53.96cm (thigh circumference), and 74.42cm (crotch length).

A STUDY ON THE CORRELATION BETWEEN IMPLANT STABILITY VALUES AND INITIAL INSERTION TORQUE

  • Lee Jong-Hyuk;Yang Jae-Ho
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.314-324
    • /
    • 2006
  • Statement of problem. Osseointegration is important mechanism of dental implant but it is not easy to evaluate. Indirect measurement is non-invasive and clinically applicable but they need more study about correlation between indirect values and degree of osseointegration. Purpose. The aims of this study were to evaluate the coefficient of correlation between indirect measurement and direct measurement under different healing time, and assessment of effect of initial insertion torque to the implant stability. Material and Methods. 20 rabbits received 3 implants on each side of tibia. Three kinds of implants (machined surface implant, Sandblasted with Large grit and Acid etched implant, Resorbable Blast Media treated implant) were used. During the surgery implant insertion torque were measured with $Osseocare^{TM}$. After the 1, 4, 8, 12 weeks of healing time, animals were sacrificed and stability values (Implant Stability Quotient with $Osstell^{TM}$, removal torque with torque gauge) were measured. Results. The Bone quality of rabbit tibia was classified into 2 groups according to the insertion torque. Resonance frequency analysis (ISQ) and removal torque showed positive correlation until $4^{th}$ week (r=0.555, p=0.040). After $8^{th}$ week (r=0.011, p=0.970) the correlation became weak and it turned negative at $12^{th}$ week (r=-0.074, p=0.801). Insertion torque and ISQ showed changing correlation upon the healing time ($1^{st}$ week: r=0.301, p=0.033, $4^{th}$ week: r=-0.429, p=0.018, $8^{th}$ week: r=0.032, p=0.865, $12^{th}$ week: r=-0.398, p=0.029). Insertion torque and removal torque has positive correlation but it was not statistically significant ($1^{st}$ week: r=0.410, p=0.129, $4^{th}$ week: r=0.156, p=0.578, $8^{th}$ week: r=0.236, p=0.398, $12^{th}$ week: r=0.260, p=0.350). Conclusion. In this study, bone quality may affect the degree of osseointegration positively during healing time and correlation between ISQ and degree of osseointegration can be different according to the healing time and bone quality.

Rocatec system이 Zir-ceram과 간접복합수지간의 전단결합강도에 미치는 영향 (Effect of Rocatec system on Shear Bond Strength between Zir-Ceram and Sinfony Indirect Composite Resin)

  • 김동일;김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.23-29
    • /
    • 2008
  • The purpose of this study is to evaluate possibility of using indirect composite resin instead of porcelain through the measurement of shear bond strength between zirconia core and indirect composite resin under treatment of $Rocatec^{TM}$ system for improving the adhesion of indirect composite resin. 20 cylindrical zirconia core specimens were divided into 2 groups, according to zirconia surface treatment and attached materials: 1) treated with sandblast and attached with indirect composite resin, 2) treated with sandblast + $Rocatec^{TM}$ system and attached with indirect composite resin. The shear bond strength of each experimental group was measured by MTS and the changes of zirconia core surface according to surface treatments were obtained by SEM observation and measurements of surface roughness. The mean shear bond strength values are $0.55\;{\pm}\;0.11MPa$(Group SC) and $1.16\;{\pm}\;0.46MPa$(Group SRC). The mean Ra values for the surface treatments were follows: $0.39\;{\pm}\;0.13$($100{\beta}_{{\mu}m}$ sandblast) and $0.50\;{\pm}\;0.03$($100{\beta}_{{\mu}m}$ sandblast + $Rocatec^{TM}$ system). In the analysis of EDS, Si element was detected in the Group SC. The shear bond strength between zirconia core and indirect composite resin was improved significantly by using $Rocatec^{TM}$ system.

  • PDF

함수율과 이방성을 고려한 석조문화유산의 초음파 측정방법 설정 (Establishment of Ultrasonic Measurement Method for Stone Cultural Heritage Considering Water Content and Anisotropy)

  • 조영훈;이찬희
    • 보존과학회지
    • /
    • 제30권4호
    • /
    • pp.467-480
    • /
    • 2014
  • 이 연구에서는 암석의 함수율과 이방성에 따른 초음파속도 변화를 분석하여 석조문화유산에 적합한 측정방법을 설정하였다. 암석의 함수율과 포화도는 건조 초기에 급격한 변화를 보이다가 변화율이 서서히 줄어드는 지수함수 형태를 나타냈다. 그러나 초음파속도 및 변화율은 10시간의 자연건조 이후 거의 일정한 수치를 유지하였다. 따라서 수분에 포화된 석조문화유산은 기상환경 및 함수조건을 고려하여 약 10시간의 자연건조 후에 초음파 측정을 수행해야 한다. 이방성지수는 화강암과 석회암에서 가장 높은 수치를 보였으며, 간접전달방법이 직접전달방법에 비해 이방성에 둔감한 측정법으로 나타났다. 그러나 간접전달방법에 의한 이방성은 모든 암석에 미약하게나마 존재하므로 다양한 방향성을 고려한 초음파 측정이 요구된다. 이 연구결과는 석조문화유산의 암석학적 특성에 적합한 맞춤형 비파괴진단과 신뢰도 높은 정밀 평가에 크게 기여할 것으로 사료된다.

ISO 10767-1에 기초한 유압 펌프의 유량 맥동 측정 및 정밀도 평가 (Measurement of Hydraulic Pump Flow Ripple Characteristics Based on the ISO 10767-1 and the Evaluation of the Measuring Accuracy)

  • 김지웅;강만곤;이일영
    • 유공압시스템학회논문집
    • /
    • 제4권3호
    • /
    • pp.22-27
    • /
    • 2007
  • The source flow ripple and the source impedance in hydraulic pump are characteristic values showing fluid-borne vibration characteristics decisively. We cannot measure these two characteristic values directly, but can measure them by some indirect methods. One representative indirect measuring method is ISO 10767-1. The authors constructed a hardware and a software for the measuring method based on ISO 10767-1. Through the error evaluation of the measured results, accuracy of the measuring method using ISO 10767-1 was examined in detail.

  • PDF

Plus-size 여성의 연령별 신체 특성에 관한 연구 (A Study on the Physical Characteristics of Plus-sized Women, by Age)

  • 하희정;김애린
    • 복식문화연구
    • /
    • 제11권1호
    • /
    • pp.153-164
    • /
    • 2003
  • For this study, 148 female adults between the ages of 20 and 60 who satisfied the plus-size judgment criteria took part in this study. Criteria were Rohrer index is higher than 1.5, bust girth larger than 90cm, and RBW(relative body weight) index higher than 110. Using anthropometric measurement values, indirect measurement values, and index values, this study analyzed frequencies, Duncan multiple range, and ANOVA to obtain information on characteristics that determine a representative body shape, by age, 1'3r Plus-sized women. The results are as follows: Physical Characteristics of Pius-Sized Women by Their Age: Women in their 20s md 30s had broader shoulders with smaller waists, with large buttocks and thighs. Among women in their 50s and 60s, body fat level increased significantly in regions such as the chest and abdomen, which made their upper body heavier.

  • PDF