• 제목/요약/키워드: Independent power system

검색결과 555건 처리시간 0.033초

A Grid Current-Controlling Shunt Active Power Filter

  • Tumbelaka, Hanny H.;Borle, Lawrence J.;Nayar, Chemmangot V.;Lee, Seong-Ryong
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.365-376
    • /
    • 2009
  • In this paper, the implementation of a three-phase shunt active power filter is presented. The filter is essentially three independent single-phase current-controlled voltage source inverters (CC-VSI) with a common DC bus. The CC- VSI is operated to directly control the AC grid current to be sinusoidal and in phase with the grid voltage without detecting the load currents. The APF consists of a current control loop, which shapes the grid currents to be sinusoidal and a voltage control loop, which regulates the active power balance of the system. The experimental results indicate that the active filter is able to handle predominantly the harmonics, as well as the unbalance and reactive power, so that the grid currents are sinusoidal, in phase with the grid voltages and symmetrical.

독립형 에너지 하우스 전력시스템에서의 BIPV용 Optimizer에 대한 연구 (A Study on Optimizer for Building Integrated Photovoltaic System of Energy Independent House)

  • 조영찬;신덕식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.229-230
    • /
    • 2018
  • 본 논문은 태양광 기반의 '독립형 에너지 하우스'의 전체 전력 시스템과 태양광 외장재 모듈의 에너지를 효율적으로 최대 수급하기 위한 BIPV(Building Integrated PV)용 Optimizer의 개발에 대해 기술한다.

  • PDF

A Study on New PV Tracking System Including Load Dispersion

  • Lee, Sang-Hun;Song, Hyun-Jig;Park, Chan-Gyu;Song, Sung-Geon
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권4호
    • /
    • pp.472-480
    • /
    • 2014
  • The In solar power system, the height and azimuth of the sun are important parameters which control generated power magnitude. The tracking method that controls the daily generation magnitude according to latitude and longitude using the two axles is often used in the existing sunlight tracking system today. In this two-axle PV track control system, the self-load is concentrated on one FRAME. It is influenced of the regular load, snow load and the wind load, etc. It is difficult to set up the system in the conventional building. This research is a development about the small-scale economy track device of independent load-dispersing solar generation system. The position tracking algorithm is through new coordinates transformation calculating the height and azimuth of the sun.

A Novel Multi-Level Inverter Configuration for High Voltage Conversion System

  • Suh, Bum-Seok;Lee, Yo-Han;Hyun, Dong-Seok
    • Journal of Electrical Engineering and information Science
    • /
    • 제1권2호
    • /
    • pp.109-118
    • /
    • 1996
  • This paper deals with a new multi-level high voltage source inverter with GTO Thyristors. Recently, a multi-level approach seems to be the best suited for implementing high voltage conversion systems because it leads to harmonic reduction and deals with safe high power conversion systems independent of the dynamic switching characteristics of each power semiconductor device. A conventional multi-level inverter has some problems; voltage unbalance between DC-link capacitors and larger blocking voltage across the inner switching devices. To solve these problems, the novel multi-level inverter structure is proposed.

  • PDF

차세대 군용전원용 500W급 마이크로 터빈 발전기 시스템 설계 (Design of a 500W Class Micro Turbine Generator System as a Next Generation Military Power Source)

  • 최상규;최범석;한용식;우병철;송인혁;민성기;임진식
    • 한국군사과학기술학회지
    • /
    • 제14권6호
    • /
    • pp.1192-1197
    • /
    • 2011
  • Recent developments of small-size unmanned or manned mobile systems such as autonomous robots, exoskeleton or armored suits, micro air vehicles, and unmanned armored vehicles require long-lasting independent power sources of high energy and power density to support the systems' operation for up to 72 hours in the fields. Chemical batteries such as Ni-MH, Li-Ion, the current primary power sources for mobile devices, however, are not capable of providing enough power and energy density for the next generation high power mobile machines. For this reason, KIMM along with KERI and KIMS has been carrying out a 500W MTG development project under the DAPA's "Next generation military power source R&D program" since 2009. In this paper, a design process for a 500W MTG system currently being developed at KIMM is briefly described and the technical issues related to its development are addressed.

대학 캠퍼스 내 에너지저장장치 연계에 따른 잉여 수소에너지 생산에 관한 연구 (A Study on the Production of Hydrogen Energy According to Installed Capacity of Energy Storage System on Campus)

  • 최봉기;전종현;김성열
    • 전기학회논문지P
    • /
    • 제67권2호
    • /
    • pp.94-99
    • /
    • 2018
  • Depending on how the energy storage system(ESS) is used in a system that can construct a microgrid by using an independent power source such as campus, surplus power can be generated that can not be charged to the ESS. For example, assuming that heat is supplied by a fuel cell in the case of a system in which thermal self-sustaining is prioritized, the fuel cell capacity required differs depending on the heat load. The amount of surplus power that can not be stored in the ESS will appear differently depending on the load operation of the fuel cell for each cycle. This power is hydrogenated through a water electrolytic device to present the amount of hydrogen energy that can be operated for each cycle. Therefore, this paper propose the possibility of utilizing University campus as a hydrogen station.

전원 및 신호시스템에서의 뇌서지 전파양상 (Propagation Tendency of Lightning Surge in the Power and Communication System)

  • 이태형;조성철;엄주홍
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.245-249
    • /
    • 2007
  • The tendency of lightning surge to propagate displays the difference for applicable power and equipment. However, looking into the subject equipment with the lightning surge, the lightning surge can be divided in between the two lines of power, between the power line and the ground, the power line and the PE conductor, between the neutral line and the ground and the like. In addition, in the event of the communication equipment, there exists the case of lightning surge entered from the power line in addition to the entry between the communication lines, the communication line and the ground. In this study, the tendency of propagation of lightning surge penetrated on to the subject equipment is analyzed through the empirical experiment in accordance with the ground method by using the independent ground, common ground, bypass arrester and others among the techniques for safety improvement in power lines.

  • PDF

태양광모듈과 리튬이온전지를 이용한 가동보용 친환경 전원공급장치의 설계 및 구현 (Design and Implementation of Eco-friendly Power Supply System for Moveable-weir Using PV Module and Li-ion Battery)

  • 강민관;최성식;남양현;이후동;박지현;노대석
    • 전기학회논문지
    • /
    • 제67권2호
    • /
    • pp.186-193
    • /
    • 2018
  • Generally, it is difficult to operate moveable-weir due to the expensive cost of the facility management and manpower consumption. Also, when it is installed in a remote area, there is a problem that the cost of connection for power system increases as well as the operating cost. Therefore, this paper proposes an optimal design algorithm to replace an existing power system with an Eco-friendly power supply system for movable-weir using PCS, PV module and lithium-ion battery. Also, this paper proposes a modeling method of environment-friendly power supply system for a movable-weir based on the PSCAD/EMTDC S/W and implements 5[kW] prototype environment-friendly power supply system. As a result of the performance test using the S/W modeling and the prototype system, it is confirmed that the proposed system has stable characteristics in the independent operation mode and the interconnection mode.

혈중 목표 농도 자동 조절기(TCI) 개발 PART2: 시스템 구현 및 평가 (Development of Target-Controlled Infusion system in Plasma Concentration. PART2: Design and Evaluation)

  • 안재목
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권1호
    • /
    • pp.45-53
    • /
    • 2003
  • Based on the 4-compartmental pharmacokinetic model developed in PART1, target-controlled infusion(TCI) pump system was designed and evaluated. The TCI system consists of digital board including microcontroller and digital signal process(DSP), analog board, motor-driven actuator, user friendly interface, power management and controller. It provides two modes according to the drugs: plasma target concentration and effect target concentration. Anaesthetist controls the depth of anaesthesia for patients by adjusting the required concentration to maintain both plasma and effect site in drug concentration. The data estimated in DSP include infusion rate, initial load dose, and rotation number of motor encoder. During TCI operation, plasma concentration. effect site concentration, awaken concentration, context-sensitive decrement time and system error information are displayed in real time. Li-ion battery guarantees above 2 hours without power line failure. For high reliability of the system, two microprocessors were used to perform independent functions for both pharmacokinetic algorithm and motor control strategy.