• Title/Summary/Keyword: Incomplete Connection

Search Result 32, Processing Time 0.036 seconds

Evaluation of Ground-Water Sampling Techniques for Analysis of Chlorofluorocarbons (지하수의 CFCs(Chlorofluorocarbons) 조사를 위한 시료 채취 방법의 평가)

  • 고동찬;이대하
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.2
    • /
    • pp.1-8
    • /
    • 2003
  • Two types of ground-water sampling techniques for CFCs (chlorofluorocarbons) analysis, the cold-welded copper tube method and flame-sealed borosilicate glass ampule method, were compared and evaluated. CFCs concentrations by the copper tube method showed a poor reproducibility among triplicates whereas those by the glass ampule method showed a good agreement and relative standard deviations of triplicates were less than 5%. The poor reproducibility of the copper tube method appears to be attributed to the incomplete sealing in connection between faucets of wellhead and the sampling apparatus. The copper tube method also showed higher CFCs concentrations than the glass ampule method, which is more pronounced for CFC-11 than for CFC-12. The plastic tubings and rubber gasket of faucets in case of the copper tube method possibly contaminated the samples with CFC-11 and CFC-12. The potential of CFCs contamination for the glass ampule method was eliminated by using stainless steel and Nylon only and by connecting the sampling equipment directly to the main discharge pipe of wellhead. The validity of the glass ampule method were also verified by detecting very low level of CFCs for the ground-water sample which is old enough to have negligible CFCs.

A Study on Deformation Capacity of High Strength Steel Beam-to-Column Connections According to Welding Detail at Beam End (보 단부 용접상세에 따른 고강도강 기둥-보 접합부의 변형능력에 관한 연구)

  • Oh, Sang Hoon;Park, Hae Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.4
    • /
    • pp.335-348
    • /
    • 2014
  • For high-strength steel, it is difficult to be applied to flexible structural member because it have high yield ratio and low basic material's toughness. One of the great problems when using high-strength steel connections is the brittle fracture at the end of the beam member in common with general mild steel connections. In the cases of mild steel connections, it has be developed that special moment frame connection details by reinforcing structural member or improvement of welding access hole. But, it is incomplete at yet about applicability estimation of high-strength steel connections. This study is the initial step research for the applicability estimation of beam-to-column connections being applied to developed high-strength steel, HSA800. And, it studied about structural performance of the high-strength steel connections according to the details of welding access hole through full-scale test and analytical method.

A Case of Pulmonary Sequestration Supplied with Left Gastric Artery (좌위동맥으로부터 공급받는 폐결리증 1예)

  • Kang, Ji-Hyang;Lee, Goung-Sup;Lee, Chang-Seon;Choi, Hyun-Ju;Hong, Jong-Seo;Koh, Young-Min;Lee, Jai-Yung;Lee, Eon-Chun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.550-555
    • /
    • 2000
  • The bronchopulmonary sequestration is a region of the lung parenchyma that has an incomplete or no connection with the airways and is supplied by an aberrant artery arising from the aorta or one of its branches. The anatomy of the supplying artery is very important during operation. A case of pulmonary sequestration supplied with the left gastric artery is presented. The patient was 61 years old male and had hemoptysis. The chest CT showed cystic bronchiectasis in the left lower lung with few air-fluid level. Also, in aortogram, arterial supply was The aortogram also showed arterial supply coming from the left gastric artery of abdominal aorta branches. Left lower lobectomy and abnormal arterial ligation were performed.

  • PDF

The Influence of Uirimchualyo & Its Sequel on Donguibogam - Focused on throat sickness - ("의림촬요(醫林撮要)"와 "의림촬요속집(醫林撮要續集)"이 "동의보감(東醫寶鑑)"의 형성에 끼친 영향 - 인후질환(咽喉疾患)을 중심으로 -)

  • Kim, Hong-Gyun
    • Korean Journal of Oriental Medicine
    • /
    • v.15 no.2
    • /
    • pp.1-19
    • /
    • 2009
  • Some researchers who once studied Uirimchualyo have paid good attention to the connection between Donguibogam & Uirimchualyo because of their similarity. So, after reviewing the Sequel of Uirimchualyo, in terms of its editing purpose and the list of contents, especially focused on throat sickness, here I report on the conclusions I come to. Firstly, the Sequel of Uirimchualyo was a monumental edition in concert with the enthronement of Kwanghaegun, and printed at demand of new medical knowledge, which was required to add to the existing Uirimchualyo, written by best-noted doctor, Yang Yesoo, and in need of simpler medical textbook to help people's recovery from the damage of Japanese invasion in the year of Imjin & Jeongyoo. Secondly, all the contents read in the Sequel of Uirimchualyo, were quoted from Kogumuigam, compiled by Kong Shin, Manbyonghoichun, edited by Kong Jeonghyun, Dangaeshim bupbuyo, published by Bang Kwang, and Uihakipmun, edited by Lee Cheon. Thirdly, The reason of similarity between Uirimchualyo and Donguibogam is that the Sequel of Uirimchualyo was made by adding new medical knowledge to the existing Uirimchualyo, and that many of contents of the Sequel of Uirimchualyo were quoted in Donguibogam. Fourthly, regarding throat sickness, medical knowledge on acute fever was supplemented in the Sequel of Uirimchualyo, and the emergency medical treatment methodology like "blow-in-throat" was newly introduced. This treatment is worth being employed to treat acute suffocation with swollen throat in modern acute-infection sicknesses. Fifthly, the Sequel of Uirimchualyo made up for brief description of the existing Uirimchualyo, offered more convenience of users compared with too overscaled Hyangyakjipseongbang & Uibangryuchui, and was more complete than Kookupbang which was loose, incomplete, and sometimes risky. And it took firm hold before Donguibogam, and eventually made a great contribution toward Donguibogam.

  • PDF

A Study on the Safety Regulation Revision for Urban Transit Vehicles (도시철도차량의 안전기준 강화에 관한 연구)

  • Lee Woo-Dong;Shin Jeong-Ryol;Kim Gil-Dong;Han Suk-Youn;Park Kee-Jun;Hong Jai-Sung;Ahn Tai-Ki;Lee Ho-Yong;Kim Jong-Wook
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.322-326
    • /
    • 2003
  • Dae-gu subway accident raise whole points in connection with safety facilities and operating of national urban transit system like rolling stocks, facilities, management of human. Rolling stock is made every effort for improvement of performance, guarantee of comfortableness, insurance of economical efficiency. But Security like safety of fire is not thoroughgoing enough. Especially, interior material has used although it is not prove its degree of safety. it is a main cause of Dae-gu subway accident. Safety regulation of urban transit vehicle that legislate for security in March 2000 does not applied manufacturing vehicles before in 2000. It has be prescribed in the regulations that incombustibles must be used. But detailed test standard related with incombustibles is not prescribe. Thus that regulation be required reinforcement of detailed test standard. Main cause of Dae-Gu subway accident is a fire in vehicle. However, many defects are found in infrastructure and operating vehicle of urban transit, such as inexperienced disposal of driver and CCC in early stage of the fire accident, unskilled opening and closing doors, insufficient escape facilities and safety facilities of a station house and tunnel, and incomplete communication system between vehicle and CTC, extraordinary step. Thus the aims of this study are prevention of urban transit accident, improvement plan of safety driving, and proposal of quick action plan through analysis of total faculty of vehicle.

  • PDF

Design and Simulation of a Flow Mobility Scheme Based on Proxy Mobile IPv6

  • Choi, Hyon-Young;Min, Sung-Gi;Han, Youn-Hee;Koodli, Rajeev
    • Journal of Information Processing Systems
    • /
    • v.8 no.4
    • /
    • pp.603-620
    • /
    • 2012
  • Proxy Mobile IPv6 (PMIPv6) is a network-based mobility support protocol and it does not require Mobile Nodes (MNs) to be involved in the mobility support signaling. In the case when multiple interfaces are active in an MN simultaneously, each data flow can be dynamically allocated to and redirected between different access networks to adapt to the dynamically changing network status and to balance the workload. Such a flow redistribution control is called "flow mobility". In the existing PMIPv6-based flow mobility support, although the MN's logical interface can solve the well-known problems of flow mobility in a heterogeneous network, some missing procedures, such as an MN-derived flow handover, make PMIPv6-based flow mobility incomplete. In this paper, an enhanced flow mobility support is proposed for actualizing the flow mobility support in PMIPv6. The proposed scheme is also based on the MN's logical interface, which hides the physical interfaces from the network layer and above. As new functional modules, the flow interface manager is placed at the MN's logical interface and the flow binding manager in the Local Mobility Anchor (LMA) is paired with the MN's flow interface manager. They manage the flow bindings, and select the proper access technology to send packets. In this paper, we provide the complete flow mobility procedures which begin with the following three different triggering cases: the MN's new connection/disconnection, the LMA's decision, and the MN's request. Simulation using the ns-3 network simulator is performed to verify the proposed procedures and we show the network throughput variation caused by the network offload using the proposed procedures.

Development of an Organic Scintillator Sensor for Radiation Dosimetry using Transparent Epoxy Resin and Optical Fiber (투명 에폭시와 광섬유를 이용한 방사선량 측정용 유기섬광체 센서 개발)

  • Park, Chan-Hee;Seo, Bum-Kyoung;Lee, Dong-Gyu;Lee, Kune-Woo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.2
    • /
    • pp.87-92
    • /
    • 2009
  • Remote detecting system for a radiation contamination using a plastic scintillator and an optical fiber was developed. Using a commercially available silica optical fiber and a plastic scintillator, we tested then for a real possibility as a remote monitoring detector. Also, a plastic scintillator was developed by itself, and evaluated as a radiation sensor. The plastic scintillator was made of epoxy resin, a hardener and an organic scintillation material. The mixture rate of the epoxy resin, hardener and organic scintillator was fixed by using their emission spectrum, transmittance, intensity etc. In this study, in order to decrease the light loss of an incomplete connection between an optical fiber and a scintillator, the optical fiber was inserted into the scintillator during the fabrication process. The senor used a plastic optical fiber and was estimated for its detection efficiency by an optic fiber's geometric factor.

  • PDF

Study on Fire Risk of Air Conditioner through Fire Cases (화재사례를 통한 에어컨의 화재위험성 연구)

  • Choi, Seung-Bok;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.70-77
    • /
    • 2017
  • As the quality of live gets better, the frequency of using air conditioner is along drastically increasing. On that matter, setting up measures of preventing increasing fire cases has been required. 43,413 fire cases occurred in last 2016, the cases occurred by electricity account for about 20%(8,655 cases). Among the electricity cases, the amount of cases occurred with air conditioner issues covers 1.5%; causes of the fire incidents vary, including incomplete contacts, short circuits, tracking, and such. In this study, we intend to investigate the case of ignition at the connection point where the power cord connected to the outdoor unit is arbitrarily connected during the air conditioner installation process, and to propose preventive measures against the cause in order to reduce the damage of life as well as the property from electric fire incidents.

An investigational study on telephone calls to the pediatric nursing unit (외래 및 퇴원환아 부모의 전화상담요구와 간호중재에 대한 조사연구)

  • Kang Hwa Ja;Han Kyung Ja;Choe Myoung Ae;Park Seung Hyun;Kim Young Mi;Kwon Won Kyoung;Kim Sun Gu;Ahn Hye Young;Heo Mi Young
    • Child Health Nursing Research
    • /
    • v.2 no.1
    • /
    • pp.112-126
    • /
    • 1996
  • The purpose of this study was to investigate the current status of the need of telephone call and to identify the status of nursing intervention through telephone. Head nurses of the pediatric nursing unit and a nurse of pediatric outpatient clinic wrote down the telephone record of calls by parents of children discharged from hospital from 7 am to 3 pm during the period of March to June, 1995. Content of 120 telephone calls but for 26 calls with incomplete record among 146 calls were analyzed into frequency of general characteristics, needs and nursing intervention. The needs of telephone call were identified and classified into 11 areas and analyzed into frequency of detailed content by 11 areas. Nursing intervention was identified and classified into 10 categories, and analyzed into frequency of detailed content by 10 categories. The findings of this study were as follows ; The need of telephone call was identified with nutritional state, medication, vital signs, language retardation, personal hygiene, vaccination, administration procedure, physical symptoms, follow up care management and others. The most frequent needs were physical symptoms and vaccination. A kind of food among nutrition dose of drugs among medication, fever among vital signs, cough among physical symptoms, and content of vaccination among vaccination was the most frequent needs. Nursing intervention through telephone was identified with instruction, knowledge offer, information offer, judgement, solicitation, referral and instruction, referral, connection, reassurance, reservation, and regulation. Instruction, knowledge offer and information offer was the most frequent nursing intervention by telephone call. Instruction was about a visit to hospital, a visit to nearby clinic, instruction about symptoms,, instruction about nursing care procedure, retelephoning and vaccination. Knowledge offer was about vaccination, knowledge related to medication, and dental care. Information offer and judgement was about vaccination and medication. Referral and instruction delivery was about instruction delivery following consultation to doctor, visit to emergency room and a visit to hospital following consultation to doctor. These results suggest that telephone call intervention program should be established as a field of extended pediatric nursing role in health care delivery system for the children.

  • PDF

Analysis about Flexural Strength of Steel Plate-Concrete Composite Beam using Folded Steel Plate (Cap) as Shear Connector (절곡 강판(Cap)을 전단연결재로 사용한 강판-콘크리트 합성보의 휨강도 분석)

  • Cho, Tae-Gu;Choi, Byong-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.481-492
    • /
    • 2018
  • The steel-plate concrete composite beam is composed of a steel plate, concrete and shear connector to combine two inhomogeneous materials. In general, the steel plate is assembled by welding an existing composite beam. In this study, the SPC beam was composed of folding steel plates and concrete, without a headed stud. The folding steel plate was assembled by a high strength bolt instead of welding. To improve the workability in a field construction, a hat-shaped cap was attached to the junction with a slab. Monotonic load testing under two points was conducted under displacement control mode to analyze the flexural strength of the SPC beam using a cap as the shear connector. Five specimens with shear connector types, protrusion length, and different thickness of steel plates were constructed and tested. The experimental results were analyzed through the relationship between the shear strength ratio and flexural strength in KBC 2009. The test results showed a shear strength ratio of more than 40 %. In the case of using a cap-like specimen as the shear connector, the flexural strength was 70% of the value calculated as a fully composite beam. In addition, the cap showed a smaller shear strength than the stud, but the cap served as a shear connection. When the thickness of the steel plate was taken as a variable, the steel plate exhibited a bending strength of approximately 70% compared to a fully formed steel plate, and exhibited similar deformation performance. Local buckling occurred due to incomplete composite behavior, but local buckling occurred at a 5% higher strength for a relatively thick steel plate. The buckling width also decreased by 15%.