• Title/Summary/Keyword: Incisor point

Search Result 88, Processing Time 0.022 seconds

A LONGITUDINAL ROENTGENO-CEPHALOMETRIC STUDY ON THE CEPHALO-FACIO-DENTAL RELATIONSHIPS OF NORMAL KOREAN CHILDREN AGED FROM 6 TO 11 YEARS BY SASSOUNI'S ANALYSIS (Sassouni분석법에 의한 한국 아동의 두개, 안모, 치아의 상호관계 변화에 관한 누년적 연구)

  • Ryu, Young Kyu
    • The korean journal of orthodontics
    • /
    • v.17 no.2
    • /
    • pp.165-183
    • /
    • 1987
  • The purpose of this study is to investigate the cephalo-facio-dental relationships in the craniofacial complex and their changes with age, and to use them for diagnostic and treatment purposes in the orthodontics The author studied on the changes of the cephalo-facio-dental relationships, using serial lateral cephalometric roentgenograms of 46 boys and 47 girls aged from 6 to 11 years of normal Korean children Following results were obtained 1 Means and Standard deviation of Korean children were obtained. 2 In the evaluation of the craniofacial vertical proportions, lower anterior face was larger than the upper, and upper posterior face was larger than the lower at all ages 3 The growth change was more prominent in the anterior craniofacial vertical proportion than in the posterior, and growth increment in the upper anterior facial height dimension was larger than m the lower anterior. 4 In the evaluation of the craniofacial horizontal proportion, ANS, Pog, Go and 6 were all situated posterior to their reference ares, and point B was always situated anterior to the arc passing by point A. 5. Anteroposterior growth change was the most prominent in the mandible, and there was no significant difference between the horizontal growth increment in the cranial base and that in the maxilla 6 Growth increment in the horizontal direction was larger in the mandibular apical base than in the maxillary apical base 7 The upper central incisor and the upper first molar were gradually anterior positioned against their reference ares with age increase 8 The length of mandibular corpus was larger than that of cranial base from the seven years old, and the difference was increased as the age increased 9 With age, there was slight difference in the angular relationships formed by craniofacial reference planes and axial inclinations of upper and lower permanent teeth.

  • PDF

THE CORRECTION OF CLASS III MANDIBULAR ASYMMETRY USING BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMY AND LATERAL ANGLE REDUCTION (외측 하악각 골절제술을 동반한 시상분할골절단술을 통한 골격성 3급 하악골 비대칭 환자의 치료)

  • Kang, Hee-Jea;Song, In-Woo;Kang, Yung-Ki;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.2
    • /
    • pp.132-140
    • /
    • 2010
  • Purpose: The aim of this study is to identify the usefulness of unilateral mandibular angle ostectomy, so-called "Lateral Angle Reduction", in asymmetric prognathism patients by the assessment of postoperative stability and esthetic results Patients and methods: For the retrospective study, 10 skeletal class III mandibular asymmetry patients who were performed SSRO and unilateral mandibular angle ostectomy, Lateral Angle Reduction, was selected. Lateral and posterioanterior cephalogram was taken before surgery (T0), 1day after surgery (T1) and 6month after surgery (T2). To know the esthetic results the facial width and lateral facial contour were examined on posterioanterior cephalogram and to know the postoperative stability B point and Incisor inferius was examined on lateral cephalogram. Statistical analysis was performed. Results: From T0 to T1, Intergonial width was significantly decreased, dominantly at shortened side but no significant changes at lengthened side. Those were well-maintained during 6 months. Lateral facial angle and Ramus angle was significantly decreased on only shortened side from T0 to T1. As a result, after surgery, there were no significant differences in all measurements between shortened side and lengthened side. Ramus deviation angle in shortened side and ramus angle in lengthened side which reflect the angulation of ramus on frontal plane didn't show significant changes after surgery and during postsurgical periods. Lower dental midline showed no statistical changes during postsurgical period. The relapse rate on B-point was 11.92%. Conclusion: Unilateral "Lateral angle reduction" in the asymmetric mandible is valuable to obtain the narrow lower face and symmetric facial contour with a good stability.

Innovative customized CAD/CAM nickel-titanium lingual retainer versus standard stainless-steel lingual retainer: A randomized controlled trial

  • Gelin, Emilie;Seidel, Laurence;Bruwier, Annick;Albert, Adelin;Charavet, Carole
    • The korean journal of orthodontics
    • /
    • v.50 no.6
    • /
    • pp.373-382
    • /
    • 2020
  • Objective: To compare computer-aided design and computer-aided manufacturing (CAD/CAM) customized nitinol retainers with standard stainless-steel fixed retainers over a 12-month study period. Methods: This randomized controlled trial (RCT) was conducted on 62 patients randomly allocated to a control group that received stainless-steel retainers or a test group that received customized CAD/CAM nickel-titanium retainers. Four time points were defined: retainer placement (T0) and 1-month (T1), 6-month (T2), and 12-month (T3) follow-up appointments. At each time point, Little's irregularity index (LII) (primary endpoint) and dental stability measurements such as intercanine width were recorded in addition to assessment of periodontal parameters. Radiological measurements such as the incisor mandibular plane angle (IMPA) were recorded at T0 and T3. Failure events (wire integrity or debonding) were assessed at each time point. Results: From T0 to T3, LII and other dental measurements showed no significant differences between the two groups. The data for periodontal parameters remained stable over the study period, except for the gingival index, which was slightly, but significantly, higher in the test group at T3 (p = 0.039). The IMPA angle showed no intergroup difference. The two groups showed no significant difference in debonding events. Conclusions: This RCT conducted over a 12-month period demonstrated no significant difference between customized CAD/CAM nickel-titanium lingual retainers and standard stainless-steel lingual retainers in terms of dental anterior stability and retainer survival. Both retainers eventually appeared to be equally effective in maintaining periodontal health.

ROENTGENOCEPHALOMETRIC STUDY FOR THE CHILDREN IN THE PRIMARY DENTITION OF KOREAN (한국인 유치열기 아동의 두부방사선 계측학적 연구)

  • Kim, Dong-Joon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.5 no.1
    • /
    • pp.64-75
    • /
    • 1978
  • In order to know cephalometric norms for the preschool children, this roentgeno cephalometric study was undertaken in each 50 Korean male and female children of primary dentition age from 4 to 5 year. The following results were obtained. 1. In the skeletal analysis, there was no significant difference between male and female in angular measurement and the linear measument of the male was generally greater than that of the female. 2. Saddle angle was $122.3^{\circ}$, articular angle was $147.6^{\circ}$, gonial angle was $119.4^{\circ}$ and the sum of each angle was $396.1^{\circ}$ in male and $396.6^{\circ}$ in female. 3. The ratio of mandibular body to anterior cranial base was about 1 : 0.91. 4. In the primary dentition, suggested that the nasion and point A move forward relative to sella turcica in a fashion, pogonion and point B are equal in angular position relative to plan S-N, bony chin and chin button was yet underdeveloped, and the forward growth of mandible was seen rapid than maxilla after 4 years. 5. Suggested that the percentage of anterior facial height to the posterior facial height were 64.4% in male and 64.1% in female. 6. Maxillary primary incisors was more upright than the permanent incisors, mandibular primary incisors was inclined lingually relative to the permanent incisor, and primary incisors was more upright than the permanent incisors. 7. Maxillary primary incisors in female was inclined labially than male. 8. In the the relationship of the upper lip and lower lip to the esthetic line, the upper lip was 2.11mm and the lower lip was 2.33mm front of the esthetic line.

  • PDF

STABILITY AFTER SURGICAL CORRECTION OF MANDIBULAR PROGNATHISM USING BILATERAL SAGGITAL SPLIT RAMUS OSTEOTOMY AND FIXATION WITH POLY-L/DL-LACTIDE COPOLYMER SCREWS ($BIOSORB^{TM}FX$) (하악지 시상 골절단술 이후 흡수성 나사를 사용하여 고정한 환자에서 술 후 안정성에 대한 연구)

  • Kwon, Taek-Kyun;Kim, Yong-Deok;Shin, Sang-Hun;Kim, Uk-Kyu;Kim, Jong-Ryoul;Chung, In-Kyo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.2
    • /
    • pp.160-163
    • /
    • 2005
  • This study was designed to assess skeletal stabilily after surgical correction of mandibular prognathism by bilateral saggital split ramus osteotomy(BSSRO) and fixation with absorbable screws. From July 2001 to September 2003, 30 patients with Class III malocclusion were treated with BSSRO and mandibular setback. They underwent fixation with Biosorb$^{TM}$ FX screws. Cephalograms were obtained preoperatibely, 2 or 3 days postoperatively, and about 12 months after the operation. Changes in the position of lower incisor tip, B point, and pogonion were examined on lateral cephalograms. The mean mandibular setback just after surgery was 10.6mm. 12 months after surgery, mean relapse at pogonion represented 17.9% and 15.1% at B point. Our results suggest that fixation of the bony segments with absorbable screws after BSSO may be used effectively in properly selected cases.

Study of soft tissue changes in the upper lip and nose after backward movement of the maxilla in orthognathic surgery

  • Seon, Suyun;Lee, Hyun-Woo;Jeong, Bong-Jin;Lee, Baek-Soo;Kwon, Yong-Dae;Ohe, Joo-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.6
    • /
    • pp.385-392
    • /
    • 2020
  • Objectives: This study evaluates soft tissue changes of the upper lip and nose after maxillary setback with orthognathic surgery such as Le Fort I or anterior segmental osteotomy. Materials and Methods: All 50 patients with bimaxillary protrusion and skeletal Class II malocclusion underwent Le Fort I or anterior segmental osteotomy with backward movement. Soft and hard tissue changes were analyzed using cephalograms collected preoperatively and 6 months postoperatively. Results: Cluster analysis on the ratios shows that 2 lines intersected at 4 mm point. Based on this point, we divided the subjects into 2 groups: Group A (less than 4 mm, 27 subjects) and Group B (more than 4 mm, 23 subjects). Also, each group was divided according to changes of upper incisor angle (≥4°=A1, B1 or <4°=A2, B2). The correlation between A and B groups for A'/ANS and Ls/Is (P<0.001) was significant; A'/A (P=0.002), PRN/A (P=0.043), PRN/ANS (P=0.032), and St/Is (P=0.010). Variation of nasolabial angle between the two groups was not significant. There was no significant correlation of vertical movement and angle variation. Conclusion: The ratio of soft tissue to hard tissue movement depends on the amount of posterior movement in the maxilla, showing approximately two times higher rates in most of the midface when posterior movement was greater than 4 mm. The soft tissue changes caused by posterior movement of the maxilla were little affected by angular changes of upper incisors. Interestingly, nasolabial angle showed a different tendency between A and B groups and was more affected by incisal angular changes when horizontal posterior movement was less than 4 mm.

Effectiveness of the Invisalign Mandibular Advancement Appliance in Children with Class II Division 1 Malocclusion

  • So-Youn An;Hyeon-Jin Kim;Ho-Uk Lee;Sang-Ho Bak;Hyo-Jin Kang;Youn-Soo Shim
    • Journal of dental hygiene science
    • /
    • v.23 no.4
    • /
    • pp.245-254
    • /
    • 2023
  • Background: This study aimed to determine the skeletal and dental effects in pediatric and adolescent Korean patients with Class II Division 1 malocclusion treated using the Invisalign Mandibular Advancement (MA®) appliance. Methods: The study included patients aged 6 to 18 years who received orthodontic treatment with the MA® appliance for Class II Division 1 malocclusion at the Department of Pediatric Dentistry, Wonkwnag University Daejeon Dental Hospital, between July 1, 2018, and December 31, 2021. The treatment group consisted of 20 patients, 10 boys and 10 girls. The control participants were also 10 boys and 10 girls. Lateral cephalometric radiographs were taken before and after treatment, and 41 measurements of skeletal and dental changes were measured and analyzed using the V-CephTM 8.0 (Osstem Implant). All analyses were performed using SPSS software (IBM SPSS for Windows, ver 26.0; IBM Corp.), and statistical significance was tested using paired and independent samples t-tests for within-group and between-group comparisons, respectively. Results: The patients in the treatment group showed significant decreases in ANB (A point, Nasion, B point), maxillary protrusion, maxillary anterior incisor labial inclination, and maxillary protrusion after treatment. However, when compared with the growth changes observed in the control group, only ANB and maxillary protrusion decreased, with no significant differences in SNA, SNB, and mandibular length. Conclusion: Collectively, the results of this study confirm that the use of MA® appliance in pediatric and adolescent Korean patients with Class II Division 1 malocclusion results in a reduction of anteroposterior skeletal and dental disharmony.

THE FRACTURE RESISTANCE AND STRESS DISTRIBUTION OF ALL CERAMIC CROWNS WITH TWO TYPES OF FINISH LINE ON MAXILLARY CENTRAL INCISOR (상악중절치에서 전부도재관의 finish line형태에 따른 파절강도와 응력 분포에 관한 연구)

  • Ki Tae-Seok;Kim Kyea-Soon;Lee Jin-Han;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.405-420
    • /
    • 2003
  • Purpose : The purpose of this study was to compare the fracture resistance of the IPS Empress ceramic crown with 1.0mm width rounded shoulder, which is usually recommended in all ceramic crown. and 0.5mm width chamfer finish lines on the maxillary central incisor. Material and method : After 15 metal dies were made for each group, the IPS Empress all ceramic crowns were fabricated and cemented with resin cement(Bistite resin cement, Tokuyama Soda Co. LTD., Japan) on the metal die. The cemented crowns were mounted on the positioning jig and the universal testing machine(Zwick Z020, Zwick Co. Germany)was used to measure the fracture strength with loading on the incisal edge. And also, three-dimensional finite element stress analysis was used to measure the stress distribution with the various types of the finish lines(1.0mm width rounded shoulder, 0.5mm width chamfer), the loading site(incisal edge, incisal $\frac{1}{3}$) and the type of loading(concentration loading, distribution loading). Results and conclusion : 1. In the fracture resistance experiment according to the finish line, the mean fracture strength of rounded shoulder(876N) and the mean fracture strength of chamfer(882N) did not skew any significant difference between each other(p>0.05). 2. The stress distribution of all ceramic crown in three dimensional finite element analysis showed concentration aspect at loading point and cervical area or labial surface. 3. In metal die, there were no differences in stress distribution between finish lines, but in natural teeth model, chamfer finish line showed higher stress than rounded shoulder finish line. 4. When force was loaded on the incisal edge the stress was concentrated on the incisal edge and the cervical area of labial surface. When force was loaded on the incisal $\frac{1}{3}$, the stress concentrated on the cervical area of labial surface and the cingulum area. 5. Generally, natural teeth model showed higher and various stress than the metal die.

Finite-element investigation of the center of resistance of the maxillary dentition (상악 치아군의 저항중심의 위치에 관한 3차원 유한요소 해석)

  • Jeong, Gwang-Mo;Sung, Sang-Jin;Lee, Kee-Joon;Chun, Youn-Sic;Mo, Sung-Seo
    • The korean journal of orthodontics
    • /
    • v.39 no.2
    • /
    • pp.83-94
    • /
    • 2009
  • Objective: The aim of this study was to investigate the 3-dimensional position of the center of resistance of the 4 maxillary anterior teeth, 6 maxillary anterior teeth, and the full maxillary dentition using 3-dimensional finite element analysis. Methods: Finite element models included the whole upper dentition, periodontal ligament, and alveolar bone. The crowns of the teeth in each group were fixed with buccal and lingual arch wires and lingual splint wires to minimize individual tooth movement and to evenly disperse the forces to the teeth. A force of 100 g or 200 g was applied to the wire beam extended from the incisal edge of the upper central incisor, and displacement of teeth was evaluated. The center of resistance was defined as the point where the applied force induced parallel movement. Results: The results of study showed that the center of resistance of the 4 maxillary anterior teeth group, the 6 maxillary anterior teeth group, and the full maxillary dentition group were at 13.5 mm apical and 12.0 mm posterior, 13.5 mm apical and 14.0 mm posterior, and 11.0 mm apical and 26.5 mm posterior to the incisal edge of the upper central incisor, respectively. Conclusions: It is thought that the results from this finite element models will improve the efficiency of orthodontic treatment.

Artificial teeth displacement of monolithic complete denture manufactured by 3D printer and milling machine (3차원 적층 출력과 밀링에 의해 제작된 일체형 의치의 인공치 변위 평가)

  • Kwak, Young-Hun;Lee, Sea-Han;Lee, Gyeong-Je;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.394-402
    • /
    • 2017
  • Purpose: The purpose of this study is to evaluate the displacement of artificial tooth of monolithic complete denture manufactured by milling and 3D printing method in which the denture base and the artificial teeth are simultaneously made. Materials and methods: Twelve upper and lower complete dentures for each were made by milling and 3D printing method. Group Up and Group Lp are a group of upper and lower dentures made by printing, and Group Um and Group Lm are denture groups made by milling. Group Uc and Group Lc are is a group of finally designed upper and lower dentures respectively. Measurements were performed between both central incisors (AB, ab), both canines (CD, cd), both first molars (EF, ef), between an incisor and a first molar (AE, ae), and between incisor and lingual point (AG, ag) for each upper and lower denture. Results: AG and ag value between printed dentures and original ones as well as between milled dentures and original ones showed a statistically significant difference (One-way ANOVA, P<.05) in both lower and upper monolithic dentures. In the lower monolithic ones, ab, cd and ef value revealed a significant difference between Group Lp and Group Lm (One-way ANOVA, P<.05). Conclusion: Dentures made using milling or 3D printers revealed statistically significant difference compared with those of original data. However, it showed clinically very accurate reproducibility.