• Title/Summary/Keyword: Incinerators

Search Result 129, Processing Time 0.026 seconds

PCDD/Fs Levels and Congener Pattern Characteristics in Stack Gas and Fly Ash from Waste Incinerators, Environmental Media, Food, and Human Tissues: An Overview (국내 폐기물소각시설 배출가스와 소각재, 환경 매질, 식품 및 인체에서 검출된 다이옥신 농도수준 및 이성질체 유형 특성)

  • Kim Su-Jin;Park Soyoung;Choi Seung-Pil;Lee Dong Soo
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.1
    • /
    • pp.1-24
    • /
    • 2004
  • Since dioxins became a serious concern in Korea, a significant number of investigations have been conducted to address diverse issues related to dioxins. However, the results have not been organized for ready access and use. The principal purposes of the work were to ⅰ) provide an archive of dioxin researches in Korea and ⅱ) give an overview of dioxin contamination. The focus of this work was placed on the contamination levels and characteristics concerning the waste incinerators emissions, environmental media, and biological samples(fishes/shellfishes, foods, and human body). Principal component analysis was conducted to identify common and/or unique features and the important variables associated with the congener patterns. From a comprehensive search of academic journals, research and monitoring project reports, dissertations, and periodicals of other forms, a total of 115 counts were found that met the purposes of this study. The contamination levels of various samples were summarized and compared to those reported in foreign literatures. The congener patterns varied largely with environmental media and distinguished particularly by OCDD, 1,2,3,4,6,7,8-HpCDF, and OCDF for the samples within the same media. The proximity to emission sources differentiated the congener patterns in air and soil samples by the fraction of OCDD.

Chemical Analysis of Fly Ashes from Municipal Solid Waste Incinerators (생활폐기물 처리시설 배출 비산재의 조성분석)

  • Jang, Seong-Ki;Choi, Duk-Il;Lim, Chang-Ho;Lee, Jin-Sook
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.215-221
    • /
    • 2000
  • Analysis of fly ashes from the MSW incinerators was carried out using XRF, ICP-MS and ICP-AES. It was found that the major elements of fly ash were Ca, K, Na, Si, Al, S, Cl and O by the XRF analysis. The XRD spectra showed that the fly ashes were mainly consisted with the chlorides, hydroxides, carbonates and also oxides of former elements. For the determination of minor elements such as Zn, Pb, Cu, Cr, and Cd, we used ICP-AES and ICP-MS after microwave digestion and the results were compared with the result of XRF.

  • PDF

PAHs Source Fingerprints for Municipal Incinerator, Motor Vehicle Fuels and Industrial Boilers Emission (발생원별에 따른 PAHs 배출특성)

  • 박찬구;윤중섭;김민영;손종열;모세영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.3
    • /
    • pp.331-343
    • /
    • 2004
  • The results of individual PAH source profiles that can be applied to receptor model are as follows. The sum of 16 PAH concentrations was 391.41 ng/S㎥ in a tunnel. Phenanthrene was the most abundant compound among 16 PAH, and then pyrene, fluoranthene, anthracene, and naphthalene can be seen in elevated contents. 11,056.61 ng/S㎥ of 16 PAH concentrations in BC oil boiler was two times higher than 6,582.57 ng/S㎥) of those in LNG boiler. Naphthalene was the most abundant compound in both facilities. Phenanthrene, anthracene, and acenaphthylene were the second dominant compound group in order from both facilities. BC oil boiler had relatively high concentration of pyrene compared to LNG boiler that had high concentration of fluorene and did not detect pyrene. The sum of 16 PAH concentrations emitted from MSW incinerators after APCD (air pollution control device) was three times higher than those from MSW incinerators before APCD. However, the concentrations of more than 4-ring PAH compounds (e.g., benzo (a)anthracene) before APCD were higher than those after APCD. This fact implies that PAHs generated by combustion process are eliminated in APCD and they are continuously produced in stack or atmosphere by PAHs precursors.

A Case Study on Health Impact Assessment from Incinerator Operation in New Towns - Human Risk Assessment due to Heavy Metals Inhalation - (신도시 내 소각로 운영에 대한 건강영향평가 사례 연구 - 중금속 흡입에 따른 인체 위해도 평가 -)

  • Myung, Nho-Il;Lee, Young-Soo;Shin, Dae-Yewn
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.3
    • /
    • pp.271-279
    • /
    • 2010
  • We conducted a quantitative human health risk assessment with respect to inhalation of heavy metals for residents of housing developments in "new towns" where an incinerator will be operated within the area scheduled for construction thereof. To assess potential human health risk we calculated the amount of heavy metals emitted from the incinerator, and then forecasted the potential health impact on adjoining areas where new housing is to be developed (i.e. "new towns") at different altitudes by a using SCREEN-3 model. We assessed Cancer Risk (CR) caused by known carcinogens using the Inhalation Unit Risk criteria developed by the US Environmental Protection Agency. Notably, we assessed risk by determining concentrations of heavy metals on a floor by floor basis, as apartment buildings are to be constructed near the incinerator according to a pre-devised plan. Results indicated that cancer risk for most carcinogens exceeded US EPA standards for the highest locations at each collection point. This result indicates that construction of high buildings in areas adjoining incinerators is undesirable, and that measures to lower carcinogens are needed. The results of this study, which assessed health risk from exposure to heavy metals emitted from a nearby incinerator, can be useful in land use planning with respect to the location of housing developments in new towns, as well as the heights of any buildings constructed. Furthermore, the methodology deployed herein with respect to risk assessment can be helpful for policy makers and the general public in the event of conflicts regarding incinerator projects in the future. The results herein may also be of merit in determining priorities when establishing harm reduction measures for carcinogens at incinerators. However, the study does contain several limitations. The SCREEN-3 model, a kind of screening model that provides conservative results, can provide higher forecasted concentrations of air pollutants than other models. Moreover, although the incinerator in question is set to be a thermoselect type, domestic data for emissions from these incinerators is not available, and assumptions were based on a stoker type incinerator. Insufficient domestic data likewise compelled the use of data of USA, resulting in possible errors in results. Continued research will thus be required to develop systematic methodologies that address the foregoing factors and produce more reliable outcomes.

Optimization of Incinerator Controllers using Artificial Neural Networks

  • Mackin, Kenneth J.;Fukushima, Ryutaro;Fujiyoshi, Makoto
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.334-337
    • /
    • 2003
  • The emission of dioxins from waste incinerators is one of the most important environmental problems today, It is known that optimization of waste incinerator controllers is a very difficult problem due to the complex nature of the dynamic environment within the incinerator. In this paper, we propose applying artificial neural networks to waste incinerator controllers. We show that artificial neural networks can project the emission of dioxins with a fair degree of accuracy.

  • PDF

The Nimby Syndrome and Basic Plan for Waste Treatment Facilities in 1994 (님비와 폐기물처리시설 설치 방향)

  • 신현국
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1994.03a
    • /
    • pp.59-64
    • /
    • 1994
  • In order to democractically resolve the "not-in-my-backyard" (Nimby syndrome) which is widespread in Korea, the policy of the Ministry of Environmnt(MOE) is that the MOE is willing to negotiate with local inhabitants who refuse to allow the establishment of waste treatment facilities, and that such facilities will be safety and effectively constructed and managed. According to this policy, the MOE has developed a basic plan to construct 255 incinerators by the year 2001, and establish 42 sanitary landfill sites and 5 specific waste treatment facilities in 1994.s in 1994.

  • PDF

기술사마당 - 도시 쓰레기 소각에서 발생하는 다이옥신으로부터 국민건강을 지키자

  • Choi, Hae-Wuk
    • Journal of the Korean Professional Engineers Association
    • /
    • v.46 no.2
    • /
    • pp.44-50
    • /
    • 2013
  • The treatment of city life wastes is headache problem. Now, only small portion of burnable wastes is burnt at modern process incinerators, the other large portion is buried in the soil by landfill method. The burnable wastes will be increased year by year. The dioxin, the cancer-causing agent, produced by incineration of wastes influences harmful effect to national human health. The new idea of burnable wastes treatment is using the city life wastes as auxiliary fuel of fluidizing bed combustion boiler of large scale coal-fired power plant. The dioxin-free treatment of burnable wastes is sucessfully achieved by burning the wastes, in flyash storm at fluidizing bed combustion boiler.

  • PDF